Loading…
Loading…
Tender Value
₹7.5 L
EMD Value
₹18,811
Closing Date
3 Oct 2026, 3:00 pmDue tomorrow
Assistant Executive Engineer
LSGD DIVISION, JILLA PANCHAYATH, PATHANAMTHITTA
Annual Plan- JP PTA PR.No . 428/26 (463/25, 253/24) --PR.No. 428/26 (463/25, 253/24) - Adoor Govt Girls Higher Secondary School Maintenance- General Civil Work
2026_LSGD_871600_14
02/2026-27/AEE/LID and EW/PTA
Open Tender
Civil Works - Buildings
Item Rate
180 days
PATHANAMTHITTA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,660
₹18,811
Yes
24 Sept 2026
24 Sept 2026
7 Oct 2026
24 Sept 2026
3 Oct 2026
24 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Temporary Fitness Related Work | |||||
| 1.001 | 50.12.4.1:Providing and fixing false ceiling with 7.5 mm thick PVC plain panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete (aluminium frame work shall be paid separately) | 240.24 | sqm | - | - |
| 1.002 | 21.5:Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ). | 165.29 | kg | - | - |
| 1.003 | 50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete | 10.06 | cum | - | - |
| 1.004 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 143.09 | sqm | - | - |
| 1.005 | OD136031/2026-2027:Steel work for single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | 222.63 | kg | - | - |
| 1.006 | OD132869/2026-2027:Providing and fixing pre coated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.30 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5- 7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns.
Sheet should •have protective guard film of 25 microns minirnum to avoid scratches
during transportation and should be supplied in single length up to 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size ,(5.5x55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required | 38.25 | sqm | - | - |
| 1.007 | 9.147A.3:Providing and fixing factory made uPVC white colour casement/casement cum
fixed glazed windows comprising of uPVC multi-chambered frame, sash and
mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2
mm thick galvanized mild steel section made from roll forming process of required
length (shape & size according to uPVC profile), uPVC extruded glazing beads of
appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction
hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8
mm size for fixing frame to finished wall, plastic packers, plastic caps and
necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut
and fusion welded at all corners, mullion (if required) shall be also fusion welded
including drilling of holes for fixing hardware's and drainage of water etc. After
fixing frame the gap between frame and adjacent finished wall shall be filled with
weather proof silicon sealant over backer rod of required size and of approved
quality, all complete as per approved drawing & direction of Engineer-in-Charge.
(Single / double glass panes and silicon sealant shall be paid separately)
Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance
in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). | 4.38 | sqm | - | - |
| 1.008 | 9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding | 63.55 | kg | - | - |
| 1.009 | OD132870/2026-2027:Black/ White/ Grey board of class room for writing with marker or choke . the board of size 2.00 m x1.2 m suitable arrangement for fixing it to wall or stand etc approved by the engineer | 6 | no | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.23 MB
BOQ_1477543.xls
BOQ • 0.31 MB
Epay.pdf
Tender Documents • 0.23 MB
PRE14.pdf
Tender Documents • 0.19 MB
ipact.pdf
Tender Documents • 0.23 MB
FOT14.pdf
Tender Documents • 0.25 MB
AFFI14.pdf
Tender Documents • 0.23 MB
viewsbd_merged.pdf
Tender Documents • 1.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .