Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹36.7 L+₹1.7 L (4.81%)Rejected-Finance 7A BENTINCK STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹37.0 L+₹2.0 L (5.77%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted | |
| 4 | L4₹44.1 L+₹9.1 L (26.0%)Rejected-Finance 14 BEPIN BEHARI GANGUALY STREET KOLKATA 700 012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L4 | Rejected-Finance Higher rate quoted |
| Sl No | Description | Qty | Unit | ASSOCIATED ELECTRICAL CONST CO. 1963 PVT.LTD L4 | MAM ENTERPRISE L3 | PERFECT IMAGE SOLUTIONS L2 | GLYPTIC L1 |
|---|---|---|---|---|---|---|---|
| 1.01SITC of Microprocessor based Intelligent, addressable 10 Loops ( Expandable upto 12 loops )fire alarm control panel ( VDS / UL / FM / ULC approved ) fully networkable with each loop capable of taking the maximum requisite number of devices as per prevailing IS , 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type.The panel shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. IS / NBC. Shiuld have the provision for incorporating with BMS | |||||||
| 1.02The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emargency condition, with integral battery charger complete as required. | |||||||
| 1.03 | The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system and BMS( RS 485 ). The panel should have modbus output & ready to communicate with remote computer. The system must be preloaded with licenced software. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor ) | 1 | Set | 6,20,000 ₹6,20,000 | 5,45,000 ₹5,45,000 | 3,85,000 ₹3,85,000 Lowest | 8,95,000 ₹8,95,000 |
| 2.01 | SITC of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved ) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended IS / NBC ) without any additional cost). (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor ) | 750 | Nos | 2,520 ₹18,90,000 | 2,350 ₹17,62,500 | 2,100 ₹15,75,000 | 1,600 ₹12,00,000 Lowest |
| 3.01 | SITC of Addressable Heat Detector (Fixed temperature cum rate of rise) ( VDS / UL / FM / ULC approved ) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor ) | 80 | No | 1,650 ₹1,32,000 | 600 ₹48,000 | 1,500 ₹1,20,000 | 150 ₹12,000 Lowest |
| 4.01 | SITC of Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor ) | 65 | Nos | 4,100 ₹2,66,500 | 1,680 ₹1,09,200 | 2,050 ₹1,33,250 | 1,000 ₹65,000 Lowest |
| 5.01 | SITC of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor ) | 16 | Nos | 8,758 ₹1,40,128 | 9,660 ₹1,54,560 | 4,800 ₹76,800 Lowest | 14,000 ₹2,24,000 |
| 6.01 | SITC of Addressable transponder/ Monitor Modules ( VDS / UL / FM / ULC approved ) for monitoring flow switches/Fire exit doors / AHU / Lift etc complete as required. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor ) | 10 | Nos | 1,000 ₹10,000 | 850 ₹8,500 | 3,800 ₹38,000 | 1 ₹10 Lowest |
| 7.01 | SITC of Addressable Relay Modules (VDS / UL & FM approved) for switching / integration of Lift / AHU etc complete as required.
(Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor ) | 20 | Nos | 500 ₹10,000 | 850 ₹17,000 | 1 ₹20 Lowest | 1 ₹20 Lowest |
| 8.01 | SITC of LED type Response Indicator ( VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make: Esser/Cerberus Pro/ Bosch/ Johnson Controls/ Notifer / Edward /Secutron/ Securiton/ Apollo / Morley / System Sensor ) | 80 | Nos | 50 ₹4,000 | 1 ₹80 Lowest | 1 ₹80 Lowest | 200 ₹16,000 |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
14 Dec 2022, 2:00 pmClosed
EXECUTIVE ENGINEER, DARJEELING ELECTRICAL DIVISION
Opposite of PWD Inspection Bungalow Kachari Road, Siliguri 734001, District Darjeeling
Construction of Himalayan center of Presidency University at Dowhill, Kurseong, District Darjeeling - S.I.T.C of Fire Detection and Alarm System
2022_WBPWD_424468_1
WBPWD/EE/DED/e-NIT- 30 of 2022-23(2nd Call)
Open Tender
FIRE FIGHTING ORG
Item Rate
90 days
DARJEELING
Please refer Tender documents.
4 documents required · 4 mandatory
₹94,000
27 Feb 2023
22 Nov 2022
16 Dec 2022
22 Nov 2022
14 Dec 2022
22 Nov 2022
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.89 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_839046.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .