Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.7 L+₹86,653.33 (3.96%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹23.2 L+₹1.3 L (5.99%)Rejected-Finance KINARADAPPAN VETTILAPPARA PO MALAPPUARM 673639 AREACODE MALAPPURAM DISTRICT | MALAPPURAM | KERALA | 673639 | L3 | Rejected-Finance L3 Rejected | |
| 4 | Rejected-Technical | - | Rejected-Technical L6 | |
| 5 | Rejected-Technical URANGATHIRI | AURANGABAD | MAHARASHTRA | 423701 | - | Rejected-Technical L5 |
Tender Value
₹25.9 L
EMD Value
₹38,840
Closing Date
4 Mar 2021, 11:00 amClosed
Exeutive Engineer
O/o Executive Engineer, Buildings Division, Malappuram
Annual Plan 2020-21 - Construction of School building of Government L.P School, Thencheeri , Urgattiri in Malappuram District.
2021_PWD_418596_1
BL/DN/MPM/51/2020-21
Open Tender
Civil Works - Buildings
Item Rate
365 days
Thencheri, Urngattiry
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹38,840
16 Jul 2021
25 Feb 2021
6 Mar 2021
25 Feb 2021
4 Mar 2021
25 Feb 2021
Amount
detailed estimate
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
od53521/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Less cement used as per design mix is recoverable. All work upto plinth level
od53522/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Less cement used as per design mix is recoverable. All work above plinth level upto floor V level
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
5.9.16.1 : Edges of slabs and breaks in floors and wallsUnder 20 cm wide
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
10.31 : Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer In charge.Providing and fixing angle iron frames for doors, windows and ventilators of mildsteel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall withdash fastener, including fixing of necessary butt hinges and screws and applying apriming coat of approved steel primer, all complete as per the direction ofEngineer In charge.
10.5.2 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece
9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
13.37.1 : White washing with lime to give an even shade:New work (three or more coats)
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick
13.30 : 18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1:5 ( 1 cement : 5 coarse sand) top layer 6mm thick with cement mortar 1:4 ( 1 cement : 4 fine sand).18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1:5 ( 1 cement : 5 coarse sand) top layer 6mm thick with cement mortar 1:4 ( 1 cement : 4 fine sand).
11.39 : Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
Ashij vp
BEST BASE CONSTRUCTIONS LLP
SHAMSUDHEEN K
NOUSHAD K
M. ABDUL LATHEEF
RANS CONSTRUCTION
Bidder Name
Ashij vp
M. ABDUL LATHEEF
NOUSHAD K
RANS CONSTRUCTION
SHAMSUDHEEN K
NEHA ERECTORS
BEST BASE CONSTRUCTIONS LLP
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_594448.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .