Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.1 L+₹87,995 (3.36%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹29.7 L+₹3.5 L (13.5%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹30.0 L+₹3.8 L (14.4%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹47.3 L+₹21.1 L (80.5%)Rejected-Finance D NO 37 8 1 MANCHUKONDA GARDENS INDUSTRIAL ESTATE VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
27 May 2022, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR AND MAINTENANCE OF CAPACITOR BANKS, DC BATTERY CHARGERS, BATTERY BANKS, CENTRAL AC PLANTS, CHILLER UNITS, AHUS AT TS-1, TS-2, RUKMINI HUB AND OTHER CONNECTED MISCELLANEOUS WORKS AT VARIOUS POCKETS OF DOLPHIN HILL AREA UNDER GE(U-I),VSKP
2022_MES_521064_1
8430/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
CLASS D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-I
₹84,000
Yes
9 Jun 2022
29 Apr 2022
28 May 2022
29 Apr 2022
27 May 2022
12 May 2022
Amount
M & L for inspection, testing, fault detection and repair of FCBC thyristor based battery charger 110V/30Amps system by certified technician from OEM onsite by replacing minor spare items all as directed by Engr-in-charge. Note: Cost of visit of technician is deemed to be included in the quoted price. Spare items if any replaced during this job will be measured and paid separately.
Supply only 110V D.C controller PCB board
Supply only 24V D input supply controller card
Supply only PCB of Thyristor card
Supply only 240V 11 Pin plugin Relay module
Supply only 20KΩ / 3 watts potentiometer
Supply only 63A MCB 2 pole DC Supply
Supply only MCB 32 Amps 2 Pole DC
Supply only MCB 10A 2 Pole DC
Supply and replace DC battery chargers 12-24Volts 10 Amps with protection against Short Circuit, Over Charge, Over Load Reverse Battery Connection or Damaged Battery., LED Indication – Power On, Battery Charging Status, Reverse Battery Connection Or Damage Battery, Micro Controller IC Base Auto Cut off Battery Charger, Automatic over charge and over discharge protections along with required controll wiring all as directed by Engr-in-charge.
Supply and replace maintenance free leak proof, Sealed lead acid dry cell battery 2 Volt , 200 Ah, DC all complete as specified and described. [Make: Exide/ Amco/SF/ Tata Green]
M & L for inspection, testing, fault detection and repair of 11KV 1240 KVAR APFC capacitor bank with by certified technician from OEM on site by replacing minor spare items all as directed by Engr-in-charge. Note: Cost of visit of technician is deemed to be included in the quoted price.
Supply and replace 80.06 KVAR, Externally Fused Capacitor Unit
Supply and replace 11 KV, Air core Dry type, Class F Aluminium wound, 1Ph, 0.2%, Series Reactor
Supply and replace 11KV, 400A, 10KA for 1 Sec, 3 Phase Vacuum Contactor
Supply and replace 11 KV/110V-190V, 50-50VA, 3Ph. Resin Cast RVT
Supply and replace 11 KV HT HRC fuses of suitable current rating
Supply and replace APFC Relay (RS485/232 Communication port)
M&L for control wiring from APFC relay to capacitor bank unit all as per OEM specification all complete as directed.
Earthing complete with copper plate 60cm×60cm × 3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip of size 25 x 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all complete as specified and directed.
M&L for taking out air cooled chiller condenser fan motor of capacity 7.5 HP, 720 RPM, 3 phase, 415V, 50 Hz, re-winding with copper wire of suitable gauge, replacing necessary wornout spares, nuts, bolts etc and fixing it back on the cooling tower all as specified and directed
M & L for cleaning of condensor units, tubes, fins , condensor fan units, expansion valves, checking and lubricating other moving mechanical parts, replacing any minor wires, lugs, connectors in the electrical control panels, tightening of all electrical connections etc 2 x 45 TR Air cooled chiller type Central AC Plant at Rukmini Hub, TS Dolphiin Hill all complete as specified and directed by Engr-in-Charge.
M & L for descaling the condenser unit tubes of 3 x 25 TR capacity central AC plant by circulating the descaling chemical HCL acid suitably diluted by scale gun by pressure feeding method after disconnecting condenser water lines, and opening the end covers of both side, brushing with suitable size of wire brush in condenser water tubing, removing the scales normalising the copper surface circulation normalising agent and refixing all dismantled parts including replacement of 3mm thick rubber gasket set all as specified and as directed.
M & L for cleaning the Air Handling Unit coil fins of 32000 CFM capacity 01 No. of 2 x 45 TR central AC plant at Rukmini HUB TS by pressure air method by using air blower and pouring dilute caustic soda direct into the fins coils and pressure water cleaning method by using pump completely and cleaning the air pre-filters thoroughly by air and water washing and refixing its original position, greesing the bearing of blower complete all as specified and directed by Engineer-in-charge.
M & L for cleaning the Air Handling Unit coil fins of 20200 CFM capacity of 3 x 25 TR Central AC plant at TS -2 Dolphin Hill by pressure air method by using air blower and pouring dilute caustic soda direct into the fins coils and pressure water cleaning method by using pump completely and cleaning the air pre-filter thoroughly by air and water washing and refixing its original position, greasing the bearing of blower complete all as specified and directed by Engineer-in-charge.
M&L for pumping down the gas of the Central AC plant of any capacities pressure testing the complete plant by dry nitrogen gas by separating high side and low side, rectifying the leakage by gas welding brazing pressure testing vaccuming the system and re-charging the system with gas testing and commissioning all as specified and as directed. Note : Cost for all machines and container for collecting the gas has to be born by the contractor at no extra cost.
Supply & Replace of pressure gauge of HP size 4" dia of rating 0 - 300 PSI all as specified and directed of make : Feibig / H-Guru
Supply & Replace of pressure gauge of LP / OP (low pressure / oil pressure) size 4"dia of rating -30 to 150 PSI all as specified and directed of make Fiebig / Heibig / Scientific
Suppy & Replace water pressure gauge of 4 " dia of range 0 - 7 Kg / sqcm or 0 - 100 PSI of make Heibig / Fiebig
Supply and replace of water/gas differential pressure, HP/LP cut out switch of suitable rating Make : Danfoss / Indfoss
Supply and replace fluid temperature sensor all as specified and directed by Engineer - in - Charge. Make : Rotex / Eqmt make
M&L for dismantling Monoblock pump-motor set 7.5 HP/5.5 KW removing scales cleaning, heating varnishing of motor winding, servicing the pump sets by replacing the worn out bushes, bearings, gland rope, gland bolts & nuts, painting etc reassembling the complete pump set including testing and commissioning complete all as directed by Engineer - in - Charge
M&L for dismantling motor set 5.5 KW removing scales cleaning, heating varnishing of motor winding, servicing the pump sets by repalcing the worn out bushes, bearings, gland rope, gland bolts & nuts, painting etc reassembling the complete pump set including testing and commissioning complete all as directed by Engineer - in - Charge.
Supply and filling refrigerant gas R 407 or as per exisiting Refrigerant of the AC plant at various installation all as specified and directed by Engineer - in - charge. Make : FLORN / REFRON / MAFRON. Note : Gas shall be supplied in sealed cylinder and empty cylinder can be taken back by contractor after consumption of Gas.
Supply and filling of compressor oil suitable for ACCEL make compressor at various installation all as specified and directed by Engineer - in - charge make : CAPILLA-D or equivalent. Note : Empty cane will be returned to contractor after consumption of Oil. The oil to be supplied in sealed cane.
Material and labour for cleaning the cooling tower Natural draught type out side, inside surface and applying one layer bitumenous black paint for making bottom of cooling tower leak proof all as specified and directed by Engineer - in - Charge
Supply & Replace for dismantling the gate valve size of 25 mm from condensor water inlet / out let with butterfly valve in same position including necessary repairs to pipe lines, provn of flanges, welding the flanges with arc welding to the pipes and painting the pipe line to match to existing surface as directed by Engineer - in - charge. Make : Flow well / INDCO / Inter valve
Supply and replace thermostatic expansion valve Make : Sporlan/ Danfoss
Supply & Replace Three Phase Air Break Contactor 10-0 Amps , Rated voltage 110V,220V,415V with 1NO Auxiliary contactor Make : Siemens cat part no. 3TS30 or equivalent in L&T / ABB/ schneider
Supply & Replace Three pole 40 Amps Air Break Contactor , Rated voltage 110V,220V,415V as per site specifications Make : CHINT part no. NC1-40 or equivalent in Siemens/ L&T / ABB / Schneider
Supply and replace 160A HRC fuse units 415 V as per site Make : Siemens 3NWTSFP160
Supply & Replace electronic Timer switch 240V , 10 Amps Make : ABB/L&T/Schneider / Siemens
M & L for brazing of copper tubes to seal any leakage joints or damaged tubes including copper tube of suitable size and flare nuts all complete as specified and directed.
Supply and replace 250A 4 pole on load changeover open or closed construction type as directed by Engr-in-charge including necessary cable leads, lugs etc complete. Make : L & T /Siemens/ABB / Schneider
M & L for Painting of metal surfaces after prepapring the old surface by scrubiing fully and removing any scales formed on the surface, applying one coat of zinc oxide primer, and then applying one coat of synthetic enamel paint of approved colour ( black / blue ) as per existing sample on surfaces as directed by Engr-in-charge
Supply & replace 40 A 3 pole MCB, 16 KA including necessary cable lugs & wire etc complete all complete as specified and directed. Make: Seimens / Schnieder / ABB / Legrand
Supply & replace 63 A TP MCB, 16 KA including necessary cable lugs & wire etc complete. MAKE: Legrand/Seimens/ABB / Schnieder
Supply & replace digital type Ammeter 96X96 mm square Flush mounted case of class 1.0 MAKE : AE / IMP / MECO / MEI / HPL
Supply & replace digital type Voltmeter 0-500V, 96X96 mm square Flush mounted case of class 1.0 MAKE : AE / IMP / MECO / MEI / HPL
Supply & replace 32 A SPN MCB, 18 KA, 240 V, AC supply, 50 Hz MAKE: Legrand/Seimens/ABB / Schnieder
Supply & replace 16 A SP MCB, 18 KA, 240 V, AC supply, 50 Hz, MAKE: Legrand/Seimens/ABB / Schnieder
M & L for chilled water MS pipeline insulation by applying synthetic rubber adhesive IS - SSR 998 make: Fevicol, adding pre-fabricated glasswool for pipe section 50mm wall thickness to cover 32 to 100 mm MS pipe, covered with waterproof PUF insulation material and aluminium cladding 24 guage thickness over the top joined by aluminium rivetting all completing as specified and directed
S&F butterfly valve 150mm dia with necessary rubber gasket, bolts, nuts and washer including taking out existing valve all as directed Make: Zoloto / L&T/ Audco
Supply and fix in repair " V "belts for AHU B82 Make : Fenner
M&L for taking out unserviceable cooling tower fan motor of capacity 7.5 HP, 720 RPM, 3 phase, 415V, 50 Hz, Vertically flange mounted from existing FRP cooling towers to repair shop, re-winding with copper wire of suitable guage, replacing necessary wornout spares, nuts, bolts etc and fixing it back on the cooling tower all as specified and directed
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing point of outdoor panel boards all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel, complete all as specified and testing on completion.
Supply and replace P.V.C insulated single core flexible 2.5sqmm copper cable for instrument wiring all as specified and directed by Engineer in charge Make : Plaza/Finolex/Polycab/Havells
Supply & fix PVC electrical insulation tape of size 8 cm x 7 Mtr x 0.125 mm industrial grade ISI marked multicolor all complete as specified and directed.
M & L for R-22 gas charging including nitrogen gas leak testing of single phase tower AC of capacity of 1.23 KW on -site all complete as specified and directed
M & L for R-22 gas charging including nitrogen gas leak testing of three phase tower AC of capacity of 1.58 KW on site as specified and directed.
Supply and replace MCB DB box, PVC , IP66 protection, for outdoor application with provision for two way cable entry including 63 Amps TPN MCB all complete as specified and directed.
Supply and replace Air Conditioner Capacitor AC 450V 50 HZ 50+6 MFD
Supply and replace Moisture and Liquid Indicators for Chiller type HVAC system as per model at site .Make: Sporlon model no. SA-15S or any other equivalent
Supply and replace filter drier DCL/UDK 305"-5/8" for central Ac plant all as directed
Supply and replace hermatically sealed compressor, R-407, Rated current : LR 175A, Max operated Current : 35Amps, Vol 31 ltr on LP side , suitable for 21 TR central AC plant of make Danfoss Model No.SZ185S4RC all complete as specified and described
M & L for cement concrete in foundations, filling and mass concreting type D2 (1:4:8) with 40mm graded aggregates for pole foundations and mass concrete etc all complete a specified and directed.
M & L for cement concrete in foundations, filling and mass concreting type C1 (1:3:6) with 20mm graded aggregates for pole foundations and copings etc all complete a sspecified and directed.
Supply and replace heat shrink type Straight through Cable jointing kit for Earthed XLPE armoured aluminium conductor complete with jointing material and accessories suitable for following cable sizes and grade all complete as specified and directed. Make : Raychem / Denson/ 3M.
240 SQmm 3 core 11KV grade
185 SQmm 3 core 11KV grade
M&L for 50mm dia GI pipe light grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specified. MAKE: TATA/JINDAL/UTKARSH / SURYA ROSHINI
Supply and replace Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm all complete as specified and directed. Make : Raychem / Denson/ 3M
M & L detecting underground cable faults by 3rd party cable fault locator machine for 11KV cables including cost of transportation, stay, fooding of technicians all complete as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5 Mtr in wide and not exc. 1.5m in depth for taking out / laying of under ground cable in trenches or cable ducts all complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil after repairing / jointing and laying and testing of cables complete all as specified
Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified
M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I all as specified. Note : Punned thickness shall be measured for payment purpose.
Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mmHV class with 'ELECTRIC' embossed on the top side in trenches along the electric cable as protection all complete as specified and directed.
Supply and lay fly ash brick of size 230x110x75mm locallly available as protection of cable in trenches complete all as specifed and as directed by Engineer in charge
M&L for cutting existing road / PCC drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified
Taking down or out existing cable of following sizes XLPE conductor from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by Engineer in charge
240/185 Sqmm 3 core 11KV grade
25/15/10/6 Sqmm 4 core 1.1 KV grade
Relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of following sizes in trenches / ducts / along walls / poles / under road etc all complete as pecified and directed.
185 Sqmm 3 core 11KV grade
25/15/10/6 Sqmm 4 core 1.1 KV grade
Supplying, laying, testing and commissioning XLPE insulated , armoured heavy duty electric cable of following sizes, with stranded aluminium conductor laid in trenches / passing through pipe / duct/ road crossing /fixed on poles / walls Complete all as specified and directed. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex [Note: The rate quoted shall inclusive of termination at ends with suitable aluminium lugs where required]
185 Sqmm 3 core 11KV grade
25 Sqmm 4 core 1.1 KV grade
16 Sqmm 4 core 1.1 KV grade
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note::a) The M/L for Items like ballast, lamp, igniters, capacitors, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items herein under this Schedule. b) Necessary tools like ladders & other T&P reuired etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
Supply only the following spares suitable for LED street light fittings of Make:GE /Havells /CG /Goldwyn /Bajaj /Philips /Surya.
Electronic driver suitable for 100 to 150 W LED light fitting
Electronic driver suitable for 70 to 80 W LED light fitting
Electronic driver suitable for 40 to 50 W LED light fitting
Surge protection device of capacity 10 KV suitable for LED light fitting
Electronic driver suitable 200 W LED light fitting
Electronic driver suitable 400 W LED light fitting
M&L for preparation of old painted steel surfaces of 9 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with 125 mm dia adhesive sticker with white letters/ blackground etc complete all as directed
M/S CHANDRA ENGINEERS AND CONTRACTORS
GS ENGINEERS
SRIESWARI ENTERPRISES
KRISHNA ENGINEARING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .