Loading…
Loading…
Tender Value
₹38.1 L
EMD Value
₹50,000
Closing Date
13 Jul 2026, 2:00 pm5d left
EXECUTIVE ENGINEER
Executive engineer Office of Executive engineer KWA, Vazhicherry, Alappuzha
State Plan 2025 26AWSS to Alappuzha Innovative Design supply Installation and Commissioning of Grid connected Solar PV Module Power Plant at Project Division office Complex at AlisseryDesign supply Installation and Commissioning of Grid connected Sol
2026_KWA_857744_1
WRD/KWA-CE(CR)/EST/31817/2025
Open Tender
Civil Works - Water Works
60 days
ALISSERY
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,760
Yes
₹50,000
Yes
25 Jun 2026
25 Jun 2026
14 Jul 2026
25 Jun 2026
13 Jul 2026
25 Jun 2026
25 Jun 2026 - 13 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 18 KW(3PHASE)Solar Power Plant(On-Grid) | |||||
| 1.001 | OD306307/2025-2026:Supply and providing wall mounted on grid solar Power Conditioning Unit (PCU) of 200-1000 V DC Input voltage range or nearest range and 400V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency
not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency and adustiable for connecting time to grid as per KSEB norms, including Data Monitoring System complete with accessories wifi/LAN connecting and connected application software etc. fixing on wall using wall brackets and giving all connection as required | - | kW | - | - |
| 1.002 | OD306361/2025-2026:Supply and providing topkon Solar Photovoltaic Module Mono Perc Half Cut of capacity 590 Wp or nearest size, manufactured in India, conforming to IS 14286/IEC 61215,IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the endof 25 years. fixing on existing steel frame work using nut bolts/screws etc in suitable direction at site condition and giving connection and inter connection wire tied using suitable steel wire
tie as per the system string design and direction of department staff | - | each | - | - |
| 1.003 | OD306437/2025-2026:Supply and providing wall mounted AC DB for on grid solar system for connecting Inverter AC side consists of a). Poly carbonate Enclosure IP65 protection with trasperant front cover with hinged door and termination arrangement, b). SPD Up1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection usingsuitable wire, c). 6-32A 4Pole AC MCB for outgoing side, giving all connection and DB fixing on wall using suitabel screws and plugs ets as required. | - | each | - | - |
| 1.004 | OD306527/2025-2026:Supply and providing wall mounted DC DB for on grid solar system for connecting 2Nos solar panel string and DB consists of a). Thermoplastic Enclosure IP65 protection with transparent front cover with hinged/screws door and termination arrangement, b). 2set 20A DC Fuse and Holder for +ve and connector for -ve incomer side, c). 2set SPD 1000V DC Up1.9kV,Ucpv 585VDC, In 15kA, Imax 40kAand giving internal connection using suitable wire, d). 2set of 10 - 20A 2Pole DC MCB for outgoing side, giving all connection and DB fixing on wall using suitable screws and plugs ets as required. | - | each | - | - |
| 1.005 | OD306537/2025-2026:Supplying and drawing 1run x 4 sq. mm PVC insulated tinned copper conductor, single core
Solar DC cable in the existing surface / recessed steel/ PVC conduit as required. | - | metre | - | - |
| 1.006 | OD306785/2025-2026:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB- 6545) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making good the damages colour washing etc. as required. | - | each | - | - |
| 1.007 | OD308789/2025-2026:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Triple pole and neutral | - | each | - | - |
| 1.008 | OD308830/2025-2026:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 amps | - | each | - | - |
| 1.009 | OD306818/2025-2026:Supplying and fixing Three phase 4wire KWh meter, 415V, 10 - 100 A range ,electronic type in the existing meter board complete with connections, testing and commissioning etc. as required (including testing if required, test certificate for submitting KSEB). | - | each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 1.47 MB
NOTICE.pdf
Tender Documents • 0.72 MB
BOQ_1449921.xls
BOQ • 0.40 MB
corri1.pdf
PDF • 0.01 MB
SPLCON.pdf
PDF • 0.02 MB
Download all tender documents and submit your bid