| Sl No | Description | Qty | Unit | TTS CONSULTANT L3 | ELECTRO FIRE PROTECT ENGINEERING & CONSULTANCY L2 | TRIPTI ENTERPRISE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Deputation of Skilled Manpower twice a month for intensive checking of all the pumps installed for fire-fighting system including sequential operation of those pumps to check the performance of each pumps. The job includes checking of all valves and other instruments installed inside pump house and making necessary rectifications/repair/ replacement to ensure proper functionality of the fire pumps. Storage of Diesel to be checked and refilling to be done whenever necessary to ensure smooth operation of Diesel Engine driven pump during emergency. Mock Test for fire pumps both in AUTO & MANUAL operations to be conducted during the visit in every 15 days and report of the test to be submitted to PWD for record.
i) For Pump House in Lady Dufferin Victoria Hospital-----1No.
ii) For Pump house in Central Blood Bank (IBTM&IH), Maniktala ------1 No.
iii) For Pump House in Calcutta Homoeopathic Medical College & Hospital, Maniktala--------1 No. | 3 | Each | 83,000 ₹2,49,000 | 45,555 ₹1,36,665 Lowest | 60,000 ₹1,80,000 |
| 2.00 | Inspection of hydrant network once in 3 months and submit report to PWD for any leakage or damage of hydrant/landing valves or any other type of valves and instruments for our further course of action to ensure proper functionality of the installed fire protection system. The scope also includes minor repair/rectification of all type of valves such as replacement of worn out or damaged gasket with new one, replacement of damaged bolts and nuts with new one etc. Major rectification such as replacement of damaged hand wheel, flanges, perforated pipes, pipe supports, valve seat rings etc. to be done on chargeable basis with prior intimation to PWD. During inspection of water network, the vendor shall drain out water from risers and recharge it with set pressure after proper flushing. Inlet valves of hydrant risers to be kept close after completion of flushing and recharging of water to avoid any accidental discharge of water.
i) In the premises of Lady Dufferin Victoria Hospital -------1No.
ii) In the premises of Central Blood Bank (IBTM&IH), Maniktala, ------- ------1 No.
iii) In the premises of Calcutta Homeopathic Medical College & Hospital, Maniktala---1 No. | 3 | Each | 33,000 ₹99,000 | 45,555 ₹1,36,665 | 10,000 ₹30,000 Lowest |
| 3.00 | Submission of Fire Safety Audit Report in monthly basis in connection with adequacy and functionality of fire protection system for the premises of
i) Lady Dufferin Victoria Hospital -------1No.
ii) Central Blood Bank (IBTM&IH), Maniktala,---1 No.
iii) Calcutta Homeopathic Medical College & Hospital, Maniktala---1 No. | 3 | Each | 24,000 ₹72,000 | 45,556 ₹1,36,668 | 10,000 ₹30,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
23 May 2026, 2:00 pmClosed
ASSTT ENGINEER, NORTH KOLKATA HEALTH SUB DIVN III
OFFICE OF THE ASSISTANT ENGINEER, P.W.Dte. NORTH KOLKATA HEALTH SUB-DIVN. - III 3rd Floor, 33A, Eden Hospital Road, Kolkata-700 073
Periodical maintenance of fire water pumps accessories inside Pump Houses through comprehensive maintenance contract including inspection of hydrant network within the premises of i Lady Dufferin Victoria Hospital, ii Calcutta Homoeopathic Med
2026_WBPWD_5013874_1
AE/NKHSD-III/NIeQ-01/26-27
Open Tender
Miscellaneous Services
Item Rate
365 days
CHMC Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
Yes
4 Jun 2026
9 May 2026
25 May 2026
9 May 2026
23 May 2026
15 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Deputation of Skilled Manpower twice a month for intensive checking of all the pumps installed for fire-fighting system including sequential operation of those pumps to check the performance of each pumps. The job includes checking of all valves and other instruments installed inside pump house and making necessary rectifications/repair/ replacement to ensure proper functionality of the fire pumps. Storage of Diesel to be checked and refilling to be done whenever necessary to ensure smooth operation of Diesel Engine driven pump during emergency. Mock Test for fire pumps both in AUTO & MANUAL operations to be conducted during the visit in every 15 days and report of the test to be submitted to PWD for record.
i) For Pump House in Lady Dufferin Victoria Hospital-----1No.
ii) For Pump house in Central Blood Bank (IBTM&IH), Maniktala ------1 No.
iii) For Pump House in Calcutta Homoeopathic Medical College & Hospital, Maniktala--------1 No. | 3 | Each | - | - |
| 2 | Inspection of hydrant network once in 3 months and submit report to PWD for any leakage or damage of hydrant/landing valves or any other type of valves and instruments for our further course of action to ensure proper functionality of the installed fire protection system. The scope also includes minor repair/rectification of all type of valves such as replacement of worn out or damaged gasket with new one, replacement of damaged bolts and nuts with new one etc. Major rectification such as replacement of damaged hand wheel, flanges, perforated pipes, pipe supports, valve seat rings etc. to be done on chargeable basis with prior intimation to PWD. During inspection of water network, the vendor shall drain out water from risers and recharge it with set pressure after proper flushing. Inlet valves of hydrant risers to be kept close after completion of flushing and recharging of water to avoid any accidental discharge of water.
i) In the premises of Lady Dufferin Victoria Hospital -------1No.
ii) In the premises of Central Blood Bank (IBTM&IH), Maniktala, ------- ------1 No.
iii) In the premises of Calcutta Homeopathic Medical College & Hospital, Maniktala---1 No. | 3 | Each | - | - |
| 3 | Submission of Fire Safety Audit Report in monthly basis in connection with adequacy and functionality of fire protection system for the premises of
i) Lady Dufferin Victoria Hospital -------1No.
ii) Central Blood Bank (IBTM&IH), Maniktala,---1 No.
iii) Calcutta Homeopathic Medical College & Hospital, Maniktala---1 No. | 3 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.49 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
2911_NKHSD3.pdf
Tender Documents • 1.50 MB
BOQ_5081742.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .