Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹33.3 L+₹2.3 L (7.35%)Rejected-Finance VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹33.8 L+₹2.8 L (9.05%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹34.7 L+₹3.8 L (12.1%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹40.5 L
EMD Value
₹81,000
Closing Date
2 Feb 2021, 6:00 pmClosed
GE AFS TEZPUR
GE AFS TEZPUR, PO- SALONIBARI, DISTT- SONITPUR ASSAM 784104
OUTSOURCING FOR MANNING AND OPERATION OF AC PLANT, DG SETS AND FIRE FIGHTING SYSTEM AT NEW TECH FLIGHT ,AVIONIC LAB , MPR,BUMB DUMP, LOGISTIC AND BPI-III AT AF STATION TEZPUR
2021_MES_409520_1
8536/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
TEZPUR
Class D Cat d(V)
6 documents required · 6 mandatory
₹500
Yes
GE AFS TEZPUR
₹81,000
Yes
24 Feb 2021
5 Jan 2021
4 Feb 2021
5 Jan 2021
2 Feb 2021
20 Jan 2021
5 Jan 2021 - 12 Jan 2021
Amount
Outsourcing for operation of DG Sets, AC Plant, pump house and fire fighting installations at New Tech Flight power house, with min one operator per shift (semi skilled, in three shifts per day for 08 hours each shift for seven days in a week comprising of the following plant/machineries /equipments at AF Stn Tezpur complete all as directed. Six DG sets alongwith panel boards of different capacity are located in same location (a) 500 KVA DG Sets ,415 Volt 50 Hz -04 Nos (b) 400 KVA DG Sets ,415 volts AC ,50Hz -02 Nos (c) Operation of LT Panel Board as and when required. (d) Booster pumping set 7.5 HP cap for feeding the water to service tank of -02 Nos (e) Dry wet automatic fire fighting systsm consisting of the following (i) Main centrifugal pumping set electric driven 100 HP cap-01 No(ii) 97.91 KVA DG Set ,415 Volt 50 Hz -01 No(iii) Jokey pump electric driven 15 HP cap -01 No (f) AC Plant total 225 TR (75 TRx03 Units) ( 75 TR x 2 units under working & 75 TR x 01 unit stand by) (g) Operation of security lights switches as per time schedule given by the Engr-in-charge-01 Job (h) Electric control panel -01 No. and all other measuring and controling instrument complete. Notes applicable for item Nos. 1 to 4 (i)The operator should record temperature, humidity for AC plant & daily DI details for DG set in the register as provided by contractor (ii) The AC plant operator must be qualified for operating the entire plant system (iii) Rate quoted rate is inclusive of all taxes, cess, levies as applicable and GST (iv) The quoted rate is inclusive of employee contribution of EPF and ESI as per EPF act 1952 and ESI act 1948, as ammended from time to time (v) Quoted rate shall not be less than the min wage (higher of min wage published by center / state as on the last date of bid submission end date)
Outsourcing for operation of DG Sets,AC plant installations at Tech Flight power house & Avionic lab, with min one operator per shift (semi skilled), in two shifts per day for 08 hours each shift for seven days in a week comprising of the following plant/machineries /equipment at AF Stn Tezpur complete all as directed. Note:- Two DG sets alongwith panel boards of different capacity are located in same location. (a) 500 KVA DG Set ,415 Volt 50 Hz -01 No (b) 125 KVA DG Sets ,415 volts AC ,50Hz -01 No (c) Operation of LT Panel Board as and when required. (d) Operation of security lights switches as per time schedule given by the Engr-in charge-01 No Job (e) AC Plant install with (i) Water cooled scrill chiller unit based central AC plant with the capacity of Compressor 26 TR & 02 Nos (02 Nos running) and automatic purage system capacity control devices and SPDP: squirrel case induction motor. (ii) Electric motor for compressor 05 HP x 04 Nos. (iii) Water cooled shell & tube type condenser with safety valves drain vlves temperature and pressure gauges for inlet / outlet water 26 TR x 02 Nos. (iv) Cooling coils & liquid lines and control valves. (v) Blower unit complete. (vi) Cooling tower with water pipe lines (vii) Water pumping set capacity 3411 LPM also on head - 02 Nos (viii) Ducts . (ix) Heat exchanger liquid indicator filters cum dryer unit and expansion valve .(x) Thermostat and gauges. (xi) Heating system using strips heaters for dehumidification / winter heating comprising of 2 KW heaters 12 Nos . (xii) Water tank PVC double layered of 2000 Ltrs - 01 No (xiii) Electric control panel - 01 No & all other measuring and controlling instruments complete
Outsourcing for operation of Air Conditioning installations at 267 SU (MPR) , with min one operator per shift (semi skilled), in three shift of 08 hrs each shift for seven days in a week complete all as specified and as directed by Engr-in-charge. The Plant consisting of following equipment/Machinaries . Package Type air cooled AC Plant of capacity=16.5TR X 06 Nos (i) Cooling coils & liquid lines and control valves. (ii) Blower unit complete. (iii) Ducts (iv) Heat exchanger liquid indicator filters cum dryer unit and expansion valve (v) Thermostat and gauges. (vi) Heating system using strips heaters for dehumidification / winter heating comprising of heaters (vii) Electric control panel - 01 No & all other measuring and controlling instruments complet. (viii) 380 KVA DG Set - 01 Nos (ix) Fire Fitting Pumping Set (Diesel Engine Pump Set - 01 No, Electric driven Pump - 01 Nos, Jockey Pump - 01 No) (x) Under ground Sump (xi) Pump Motor 05 HP and 7.5 HP -02 Nos
Outsourcing for operation of Air Conditioning alongwith DG set Installation at Bomb Dump and WWR, with min two operator per shift (semi skilled) ( one operator deploy at DB-06 AC plant and other one operator deploy at WWR AC plant), in three shifts per day for 8 hours each shift for seven days in a week comprising of the following Plant / Machineries / Equipments at AF Stn Tezpur all as directed by Engr-in-Charge. (a) AC Plant install at Bomb Dump . (i) Compressor capacity 7.5 TR x 03 Nos (02 Nos running and 01 No stand by (ii) Electric motor for compressor 10 HP x 03 Nos. (iii) Shell & tube type condenser 7.5 TR x 03 Nos. (iv) Cooling coils & liquid lines and control valves. (v) Blower unit complete (vi) Cooling tower with water pipe lines. (vii) Water pumping set capacity 3411 LPM also on head - 02 Nos. (viii) Ducts. (ix) Electric control panel - 01 No & all other measuring and controlling instruments complete. (b) DG Set install with. (i) DG Set of capacity 160 KVA-01 No (ii) AMF panel along with LT control panel-01 No (iii) Operation of Security Lights Switches as per Time schedule (c) AC plant install at WWR . (i) Compressor capacity 15 TR x 03 Nos (02 Nos working and 01 Nos as standby) . (ii) Electric motor for compressor 20 HP x 03 Nos. (iii) Shell & tube condenser 15 TR x 03 Nos. (iv) Cooling coil & liquid / refrigerant pipe with control valves. (v) Blower unit complete. (vi) Cooling tower with water pipe lines. (vii) Water pumping set of capacity 450 LPM also on head - 02Nos (viii) Ducts. (ix) Electric control panel - 01 No & all other measuring and controlling instruments complete. (x) Operation of security lights switches as per time schedule given by the Engr-in Charge.
Outsourcing for operation of DG sets of Logistic power house, with min one operator per shift (semi skilled) in one shift per day for 8 hours each shift for seven days in a week comprising of the following plant/machineries /equipment at AF Stn Tezpur under GE (AF) Tezpur all as directed. (a) 15 KVA DG Set ,415 Volt 50 Hz -01 No (b) 30 KVA DG Set ,415 Volt 50 Hz -01 No (c) Operation of LT Panel Board as and when required. (d) Operation of sequrity lights switches as per time schedule Note:- (i)The operator should record daily DI details for DG set in the register as provided by contractor (ii) Rate quoted rate is inclusive of all taxes, cess, levies as applicable and GST (iii) The quoted rate is inclusive of employee contribution of EPF and ESI as per EPF act 1952 and ESI act 1948, as ammended from time to time (iv) Quoted rate shall not be less than the min wage (higher of min wage published by center / state as on the last date of bid submission end date)
Outsourcing for operation of DG sets of BPI-III power house, with min one operator per shift (semi skilled), in three shifts per day for 08 hours each shift for seven days in a week comprising of the following plant/machineries /equipment at AF Stn Tezpur complete all as directed. (a) 110 KVA DG Set ,415 Volt 50 Hz -01 No (b) 30 KVA DG Sets ,415 volts AC ,50Hz -01 No (c) Operation of LT Panel Board as and when required. (d) Operation of security lights switches as per time schedule given by the Engr-in Charge. (e) 50 KVA DG set,415 Volt 50 Hz -01 No Note:- (i)The operator should record daily DI details for DG set in the register as provided by contractor (ii) Rate quoted rate is inclusive of all taxes, cess, levies as applicable and GST (iii) The quoted rate is inclusive of employee contribution of EPF and ESI as per EPF act 1952 and ESI act 1948, as ammended from time to time (iv) Quoted rate shall not be less than the min wage (higher of min wage published by center / state as on the last date of bid submission end date)
Singhs Construction
DEBROYENTERPRISE
Raj Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .