Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC 00 CHAH KATHAUTI CHAH KATHAUTI MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.8 L+₹1.3 L (6.40%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹25 L+₹4.5 L (22.2%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹27.5 L+₹7.0 L (34.2%)Rejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹28.3 L+₹7.8 L (38.2%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
7 Jun 2022, 6:00 pmClosed
GE I NAVY JAMNAGAR
INS NAVY VALSURA JAMNAGAR 361150
REPAIR AND MAINTENANCE OF SUMMER APPLIANCES CENTRAL PACKAGE AC PLANTS AT VARIOUS LOCATIONS AT INS VALSURA JAMNAGAR
2022_MES_517544_3
8584
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE I NAVY JAMNAGAR
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹54,000
Yes
13 Feb 2023
25 May 2022
9 Jun 2022
25 May 2022
7 Jun 2022
26 May 2022
25 May 2022 - 25 May 2022
Amount
M&L for removing from existing position, window/Split type A/C unit 1/1.5 / 2.0 Ton capacity of any make for servicing the same by complete cleaning the dust including supply and replacement of damaged wires with copper wire PVC insulated of same size, tightening of loose wire, nuts, bolts, servicing of condenser motor by oiling/greasing, changing of damaged knobs, painting the old painted surfaces with one coat of synthetic enamel paint, setting of grills alignment complete including refixing in original position, testing & commissioning all as directed by engineer-in-charge.
All as per item No. 01 above but for 5/5.5 Ton ductable split type air conditioner three phase
All as per item No. 01 above but for 11 Ton Package type air conditioner three phase
M&L for taking out rotary type compressor unit (uncut) from the split type Air Conditioner of any make, 1 ton capacity and replacing the sealed unit as per existing model with reconditioned sealed unit including the following all as specified and as directed. (a) Connection to suction/discharge pipe with necessary repair and brazing. (b) Replacing the capillary tubes of existing size and copper liquid filter. (c) Flushing of entire system before gas charging. (d) Gas charging and testing after complete replacement incl installing the machine at site and testing on full load for its smooth functioning complete all as specified and directed.
All as per item No. 04 above but for 1.5 ton capacity
All as per item No. 04 above but for 2 ton capacity
All as per item No. 04 above but for 5/5.5 ton ductable split type Air conditioner three phase
All as per item No. 04 above but for 1.5 ton split type Air conditioner three phase suitable for Refrigeration gas of R32
All as per item No. 04 above but for 2.0 ton split type Air conditioner three phase suitable for Refrigeration gas of R32
M&L for taking out rotary type compressor unit (uncut) from the Window type Air Conditioner of any make, 1.5 ton capacity and replacing the sealed unit as per existing model with reconditioned sealed unit including the following all as specified and as directed. (a) Connection to suction/discharge pipe with necessary repair and brazing. (b) Replacing the capillary tubes of existing size and copper liquid filter. (c) Flushing of entire system before gas charging. (d) Gas charging and testing after complete replacement incl installing the machine at site and testing on full load for its smooth functioning complete all as specified and directed.
All as per item No. 10 above but for 2 ton capacity
M&L for taking out Condenser unit from the split type Air Conditioner of any make and type, 1/ 1.5 ton capacity and replacing the same with copper Condenser unit including necessary connection and testing after complete replacement as specified and as directed.
All as per item No. 12 above but for 2 ton capacity
M&L for taking out Condenser unit from the Window type Air Conditioner of any make and type, 1.5 ton capacity and replacing the same with copper Condenser unit including necessary connection and testing after complete replacement as specified and as directed.
All as per item No. 14 above but for 2 ton capacity
S&F in repair of thermostat switch with knob for any make Window type Air Conditioner of capacity 1.5/2 Ton including necessary electrical connection, lugs, insulation tape etc all as specified and as directed.
M&L for insulation of split type AC of capacity 1/1.5/2 Ton complete all as specified and as directed.
S&F in repair of PVC drain pipe of 15 mm dia 1.5 mtr length suitable for Split AC 1/ 1.5/ 2 ton capacity including necessary connection and fittings etc complete all as specified and as directed.
S&F in repair of PVC pipe 63 mm dia for protection of insulation of split AC including necessary fittings all as specified and as directed. Make : Prince/Astrol
S&F in repair of thermostat switch with knob for any make Ductable split Air Conditioner of capacity 5/ 5.5 Ton including necessary electrical connection, lugs, insulation tape etc all as specified and as directed.
S&F in repair of overload protector relay suitable for Window/ split type AC of 1/ 1.5/ 2.0 ton capacity including necessary electric connections, lugs, insulation tape etc all as specified and as directed. Make: AEI/ Shriram
M&L for taking out defective burnt fan motor from the Split Air Conditioner of capacity 1/ 1.5/ 2 Ton, dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding, over hauling the motor by replacing the clamps, nuts, bolts and rubber rag etc for smooth working of motor, re-assembling the motor and testing the motor at medium and full load complete all as directed.
All as per item No. 23 above but rewinding for fan motor of 5/5.5 Ton ductable split air conditioner any make and model.
S&F in repair blower motor for 1/1.5/2 ton capacity split AC all as specified and as directed. Make: Suitable for carrier /Voltas /LG /Blue star/ Amtrex spilt AC as per manufactures make.
All as per item No. 25 above but rewinding for blower motor of 5/5.5 Ton ductable split air conditioner any make and model.
M&L for taking out defective burnt blower motor from the Window type Air Conditioner of capacity 1.5/2 Ton , dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding, over hauling the motor by replacing the clamps, nuts, bolts and rubber rag etc for smooth working of motor, re-assembling the motor and testing the motor at medium and full load complete all as directed.
S&F in repair remote suitable for Window/split type AC 1.5/2 Ton capacity as per existing make/ model complete all as specified and directed.
S&F in repair remote circuit suitable for split type AC 1/1.5/2 Ton capacity as per existing make/ model complete all as specified and directed.
S&F in repair remote circuit suitable for Ductable type AC 1.5/2 Ton capacity as per existing make/ model complete all as specified and directed.
S&F in repair contactor for split type A, 1/ 1.5/ 2 Ton capacity as per existing make and capacity/ model etc complete all as directed.
S&F in repair of air filter set suitable for split type AC of 1/1.5 / 2 tone capacity of any make and type all as specified and as directed.
S&F in repair of air filter set suitable for Split type AC of 5/ 5.5 tone capacity of any make and type all as specified and as directed.
S&F in repair of air filter set suitable for Window type AC of 1.5 / 2 tone capacity of any make and type all as specified and as directed.
S&F in repair 3 core, 1.5 Sq mm copper flexible cable for water coolers / Window type ACs / Split ACs / Refrigerator/ Deep freezer etc complete all as directed.
All as per item No. 35 above but flexible copper cable 3 core, 4 Sq.mm.
All as per item No. 35 above but flexible copper cable 3 core, 2.5 Sq.mm.
S&F in repair Fan Blade for split/ window tye AC complete all as directed.
S&F in repair 240 V, 20 Amp single pole and earth enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp SP. Make: Legrand Cat No: 6078 41 or equivalent in Schneider / L&T / ABB / Siemens.
S&F in repair 4-8 mfd running capacitor for window & Split AC of 1/1.5/2 Ton capacity including necessary electrical connections, lugs, insulation tape etc all as specified & as directed. Make: SIMCAP, Unicop, Usha, Epcos
All as per item No. 40 above but 36 mfd Capacity for AC 1.5 ton.
All as per item No. 40 above but 45 mfd Capacity for AC 2 ton.
All as per item No. 40 above but 50 mfd Capacity for AC 2 ton.
S&F in repair 80-100 mfd starting capacitor for window and Split AC of any make and cap and all as specified and as directed including necessary electrical connections, lugs, insulation tape etc all as specified and as directed. Make: Tesla, Krishnomic, Keltron, BHEL.
All as per item No. 44 above but 100-120 mfd Capacity
S&F in repair of swing motor for split type AC 1/1.5/2 ton capacity of different types and makes Each make of motor shall be same as original all as specified and as directed.
S&F in repair of copper tubing including brazing, flaring & testing of size 1/2" and 5/8" in required length including PVC insulation complete all as directed.
M&L for removing water cooler of 40/80/150 Ltr capacity from existing position after disconnecting from inlet water connection and plugged the water line and servicing the water cooler by cleaning the water tank cleaning the internal parts by blower and removing the burned wires and replacing the same with proper size copper conductor cable , repair / replacement of damaged hinges, drain pipe up to 1.5 m long , replacement of rusted nuts and bolts tightening the all connections refixing in original position connecting the water inlet and testing and complete to the entire satisfaction all as directed and specified by the Engineer-in-charge. (refrigerant filling will be measured and paid separately)
M&L for taking out old rotary compressor unit from water cooler storage type, 40 Ltr/hr cooling capacity and replacing the sealed unit with new sealed unit of same cap & model including the following:- Make: Tecumseh Kirloskar 4440/436 /443 (a) Connection to suction/discharge pipe with necessary replacement and brazing (b) Replacing capillary tube of existing size and copper liquid filters (c) Flushing of entire system before gas charging (d) Gas charging and testing after complete replacement including installing the machine at site and testing on full load for its smooth functioning complete all as specified and directed.
All as per item No. 49 above but for water cooler storage type 60/150 liter per hour cooling capacity.
S&F in repair over load protector relay of water cooler of capacity 40/60/150 Ltr make Usha/Blue star including necessary electrical connection, lugs, insulation tape etc all as specified and as directed.
S&F in repair PTMT float valve assembly 15 mm bore with plastic ball including GI nipple 3 inch long for fixing float valve for water cooler all as specified and as directed. Make: Prayag / Prince / Kisan.
S&F PVC connection pipe both end brass joint with rubber washer 45 cm long.
S&F in repair 15 mm dia concussive push button taps of cast copper alloy, screwed for iron pipe for water cooler all as specified and as directed.
S&F in repair of thermostat switch with knob for water cooler of capacity 40/80/150 liters per hour (Usha/Blue Star) including necessary electrical connection, lugs, insulation tape etc all as specified and as directed. Make : Indfoss/Ranutrol
M&L for taking out defective burnt motor from the water cooler of any size/ capacity, dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding, over hauling the motor by replacing the clamps, nuts, bolts and rubber rag etc for smooth working of motor, re-assembling the motor and testing the motor at medium and full load complete all as directed.
S&F in repair fan blade of water cooler of 40/80/150 liters per hour capacity suitable for make Usha/ Blue Star all as specified and as directed.
S&F in repair fan motor suitable for water cooler of 40/ 80/100 liters capacity complete all as directed. Make: AEU/MEI.
S&F in repair 10 mfd running capacitor for water cooler any capacity including necessary electrical connections, lugs, insulation tape etc all as specified & as directed. Make: SIMCAP, Unicop, Usha, Epcos
S&F repair 40-60 mfd starting capacitor for water cooler of any make and cap and all as specified and as directed including necessary electrical connections, lugs, insulation tape etc all as specified and as directed. Make: Tesla, Krishnomic, Keltron, BHEL.
Taking down Existing Split AC with pumping down refrigeration gas of any type using vaccum pump and transporting to another location and refixing with proper anchoring bracket including recharging gas duly tested and as directed by Enr in charge
M&L for taking out rotary type compressor unit (uncut) of refrigerator for 286/300/310 Ltr capacity (Make : Godrej / Kelvinator) and replacing the sealed unit with reconditioned sealed unit of same brand including the following all as specified and as directed. Make:- Tecumesh - 1343/ 1350/ 358/ Kirloskar/ Godrej (a) Connection to suction/discharge pipe with necessary replacement and brazing. (b) Replacing capillary tube of existing size and copper liquid filters. (c) Flushing of entire system before gas charging. (d) Gas charging and testing the unit to the entire satisfaction.
S&F in repair of suitable box type relay with over load protector refrigerator of capacity 286/ 300/ 310 liters capacity of different make and size including necessary connections, lugs, insulation tape etc all as specified and as directed. Make: Whirlpool/ Godrej
S&F in repair of cooling coil for refrigerator capacity 286/300/310 Ltrs all as specified and as directed.
Supplying and charging refrigeration gas F-22 or R-22 including checking complete system for any leakage for satisfactory operation at design temperature of the plant in all respects complete all as directed.
Supplying and charging refrigeration gas R-32 including checking complete system for any leakage for satisfactory operation at design temperature of the plant in all respects complete all as directed.
Supplying and charging refrigeration gas F-134A including checking complete system for any leakage for satisfactory operation at design temperature of the plant in all respects complete all as directed.
Supplying and charging refrigeration gas F-410a including checking complete system for any leakage for satisfactory operation at design temperature of the plant in all respects complete all as directed.
M&L for taking out Condenser unit from the Refrigerator of any make, 286/300/310 ltr capacity and replacing the same with copper Condenser unit including necessary connection and testing after complete replacement complete all as specified and as directed.
S&F in repair of thermostat switch with knob for any make refrigerator of capacity 286/ 300/ 310 liters capacity including necessary electrical connection, lugs, insulation tape etc complete all as specified and as directed. Make: Indfoss/ Ranutrol
fakhrie apostrical
M/s. Vimal Enterprise
M/s Balaji Enterprise
M/s Jagdish Machinery Stores
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .