| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.4 LAccepted-AOC H NO 74 6 JUTOGH CANTT SHIMLA HP 171 008 | SHIMLA | HIMACHAL PRADESH | 171008 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹10.7 L+₹91,805.68 (9.41%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹10.8 L+₹1.0 L (10.7%)Rejected-Finance VILLAGE PO KOTHI TEH KALPA DISTT KINNAUR HP 172107 | KINNAUR | HIMACHAL PRADESH | 172107 | 3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
19 Aug 2022, 6:00 pmClosed
GE 863 EWS
GE 863 EWS c/o 56 APO
REPAIR AND CLEANING OF SEWAGE LINE MANHOLE SEPTIC TANK SOAKAGE WELL ETC AND ALLIED WORKS IN THE UNITS OF JHAKRI MATIANA AND AVERIPATTI IN THE AREA OF AGE BRII PRITHI MIL STN UNDER GE 863 EWS
2022_MES_540029_1
GE863/EWS-T-24 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
AVERIPATTI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 863 EWS
₹20,000
Yes
22 Oct 2022
22 Jul 2022
23 Aug 2022
22 Jul 2022
19 Aug 2022
5 Aug 2022
Amount
Demolition of precast concrete block walling masonary built in cement mortar or cement lime mortar incl all quoins, arches, pillars, etc complete, all as specified and directed.
Taking down cement plaster of any description on brick or concrete surfaces etc including racking out joints, hacking for key, scrubbing ,washing down with water etc. complete all as specified and directed.
S & F in repair 110mm dia PVC (SWR) type B pipe single socketed, in any length laid in retaining wall/trenches complete all as specified and directed.
Demolition of Cement Concrete(unreinforced) of any description and in any position not otherwise specifically provided for ,complete , all as specified and directed.
M &L for pre-cast cement concrete type C-1, (1:3:6) , using 20mm graded stone aggregate as in block masonry with solid blocks, exc 10cm in width and setting in cement mortar (1:6), complete, all as specified and directed.
M&L for two coats of cement base paint on walls including preparation of new plastered surfaces, complete, all as specified and directed.
M&L for 50 mm thick cement concrete (1:3:6) type C1 (using 20 mm well graded stone aggregate), as in plinth protection, finishing cement concrete surface fair and even without using extra cement, laid in alternate panels, including forming joints at 2 mtr intervals and filled with bitumen mastics, complete, all as specified and directed.
Demolition of reinforced Cement Concrete in any position and any description including cutting of reinforcement bars to facilitate demolition, complete, all as specified and directed.
M & L for providing pre-cast Reinforced cement concrete as in landing, cover slabs (for man holes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate and setting in cement mortar (1:6), complete, all as specified and directed.
M & L for mild steel TMT bars 6 mm to 10mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete, all as specified and directed.
Demolition and breaking up drain pipes , 150 mm dia (Salt glazed stone ware, AC or Reinforced concrete) set in cement mortar ,complete , all as specified and directed.
M&L 150mm internal dia reinforced concerete pipes, class NP2, laid and jointed, complete with collars and jointed, complete, all as specified and as directed.
S&F in repair 75 mm dia PVC (SWR), type B pipe, single socketed in any length with rubber rings joints laid in trenches or in floor , completeall as specified and directed.
Removing & cleaning of blockage from WC/EWC trap of any description and in any position by removing sand/sludge/silt and other forein material deposited in it (either manually or mechanically) upto first manhole and making the seweage system functional to the entire satisfaction of Engg in Charge, complete, all as specified and as directed.
Removing & cleaning of blockage from traps of bath rooms/ kitchen sink/ wash basin/ Urinal point and gully traps of any description and in any position by removing sand/sludge/silt and other forein material deposited in it (either manually or mechanically) upto first manhole and making the seweage system functional to the entire satisfaction of Engg in Charge complete all as specified and as directed.
M&L for Cleaning of sewage lines of existing sewer line of dia 100mm to 300mm bore, laid at a any depth not exc. 3.0 m deep below ground level by mechanically means ,using appropriate technological appliances as required at site, including manholes, inspection chamber, testing after cleaning and getting out sludge and accumulated solids / semi solids from connected manholes / Lines, removing the sludge / spoil min 250 mtrs away from MOD land and refixing the manhole cover, complete, all as specified and as directed.
M&L for Pumping out/dewatering of sullage/waste water in liquid/semi liquid state from soakage wells or septic tanks of any capacity & size with mechanical means including remowing the same by means of tankers or other suitable means to a distance of 250 mtrs away from defence land and buried/dumping the same in pits of suitable size including excavation, earth work and spreading of bleaching powder, complete, all as specified and directed.
M&L for Cleaning / desludging of existing septic tank of any capacity and any depth including taking out and removing sludge and accumulated solids / semi solid contents in closed container at a place 250 mtrs away from defence land and burried in ground including necessary excavation, earth work and spreading of bleaching powder, complete ,all as specified and as directed. Note :- (i) The cubic contents of sludge will be measured after drying the sludge as mentioned at Para 11.1 in particular specification and no extra cost for necessary excavation and refilling with excavated soil over the sludge and bleaching powder shall be paid and quoted rate shall be deemed to be included for this provision. (ii) The cleaning of septic tank shall be carried out mechanically byusing apropriate technological appliances.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete, all as specified and directed.
M&L for RCC, type A-1,(1:1.5:3) using 20 mm well graded stone aggregates for cover slabs, slabs supported on walls, beams and columns in floors, roof and like complete all as specified and directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) , complete, all as specified and directed.
M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:4 using WPC 3% by weight of cement (WPC to be measured and paid separately) and finished even and smooth (without using extra cement) , complete, all as specified and directed..
Supply only water proofing compound (WPC) , complete, all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation ,etc. and getting out in Soft/loose soil, complete, all as specified and as directed.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone agg as in bed to drain pipe, incl packing under and haunching against the sides of pipe 150mm bore, after they are laid and tested ,complete, all as specified and as directed.
M&L for 150mm internal dia salt glazed storeware drain pipes, grade 'A', laid in trenches and jointed and tested , complete, all as specified and as directed.
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick each layer ,as in soil,complete, all as specified and directed.
M&L for removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point , complete, all as specified and directed.
M&L for Hardcore of broken stone of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick each layer ,watered and rammed to a true surface , complete, all as specified and directed.
Supply and fix, Vitreous China wash down water closet EWC (pedestal pattern), standard size , white (including fixing bolts, flushing cistern and flush pipe), ncuding plastic seat and cover, white, closed pattern with flat bottom, mild steel chromium plated or anodised hinging devices, connected to drains outlet including chromium plated steel jet pressure unit, fixed as in repairs, and removal of old from site, complete all as specified and directed. MAKE : HINDWARE/PRAYAG/JAQUAR/PARRYWARE/CERA
Supply and fixing in repair of existing water closet (squatt pattern) and foot rest with vitreous china (white) first quality water closet, Orissa pattern size 580x440mm with integral foot rests, including 100mm cast iron 'P' or 'S' trap and 100mm cast iron sanitary connection socket to fit WC outlet , complete including fixing of flush pipe with seat and making good the disturbed floor surfaces to match with existing and making connections serviceable complete all as specified and directed MAKE : HINDWARE/PRAYAG/JAQUAR/PARRYWARE/CERA
Net Contract Sum will be after deducting Sch Of Credit of Rs. 29498.00
R B TRADERS
M/S Gopal Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .