REPAIR AND REPLACEMENT OF LT CABLES, FITTINGS/FIXTURES AND OTHER CONNECTED E/M WORKS AT TRANSIT CAMP PALCHAN, UNDER AGE (I) R and D, MANALI
2025_MES_708182_1
AGE(I)/MNL-16/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Transit Camp Palchan
As per NIT and tender documents
5 documents required · 5 mandatory
₹500
AGE(I) R and D MANALI
₹12,000
Yes
1 Jul 2025
15 May 2025
18 Jun 2025
15 May 2025
10 Jun 2025
29 May 2025
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/densesoil, Complete all as specified and directed by Engr-in-Charge.
Returning ,fillling in trenches,spreading ,levelling,watering and well ramming in layers not exceeding 25cm thick., Complete all as specified and directed by Engr-in-Charge.
Removing excavated material/ surplus soil and depositing where directed at a distence not exceeding 50mtr.at a level not exceeding 1.5 mtr from strting point.
Supply lay/spread in trenches, river sand ,clean ,including spreading ,levelling ,punning for laying /cushioning of cables, Complete all as specified and directed by Engr-in-Charge.
Supply lay in trenches fly ash bricks, old size sub class “B” for cable protection.
Supply, lay in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape , of following nominal cross sections, confirming to IS specifications :-
3.5 Core Core 95 Sq.mm
3.5 Core Core 35 Sq.mm
4.0 core 25 sq mm
Supply and fix on pole / wall or lay in trenches under road / drain crossings etc., for drawing cables, GI pipe light grade of 50 mm bore dia , ISI marked ,of following sizes including necessery pipe ,fittings ,clamps, bolts , nuts etc., all as specified and as directed.
Supply & fix in repair MCB 40 TO 100 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting
Supply & fix in repair MCB 40- 63 Amps 2 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting
Supplying and fixing 1100 volt grade heavy duty cable PVC insulated alluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart incl 4mm suspension wire twin core cable flat 16mm square, Complete all as specified and directed by Engr-in-Charge.
M&L Electrical Earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6.3 mm thick burried directly in ground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level , connected to Aluminum strip of size 25 X 3 mm earth lead by means of bolts, nuts and washers of galvanised iron , earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board / panel board , all as specified and shown in MES schedule Electrical Plate No:-5 of SSR Part I, including excavation and earth work in any type of siol , PCC 1 : 2 : 4 type C1 in chamber , RCC 1:2:4 type C1 40 mmthick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways,with 6 mm dia MS hook, Charcoal dust, salt , funnel for watering complete and testing the Earth resistence and writing on the chamber by paint all as specified and as directed.
Cement concrete type c2 40 mm graded stone 1:3:6 in foundations,filling and mass concrete complete all as specified and directed.
M & L for cutting exisitng bitumenous road surfaces not more than 150 mm thick, removing for laying of pipes/cables, making good with PCC 1:3:6 type C1 20 mm graded aggregate to match with the adjustant surface. Note Excavation and earth work below 150 mm thick will be measured and paid under relevent items.
supply and fix HDPE couregated Pipe 40/50 mm complete all as specified and directed.
supply and fix HDPE couregated Pipe 90/110 mm complete all as specified and directed.
Supply and fixing in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete crompton or equivalent in Havell's,/Bajaj.
Supply and fixing in replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete crompton or equivalent in Havell's,/Bajaj.
M/S SUKHMANI ENGINEERS (BID ID -3318828)
M/S. TARA ENTERPRISES (BID ID -3311992)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .