Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹17.4 LAccepted-AOC PLOT NO 17 18 EWS COLONY DISTT SINGRAULI M P PIN 486889 | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486889 | L 1 | Accepted-AOC Bidder is L1 bidder. | |
| 2 | L 2₹19.4 L+₹2.0 L (11.7%)Rejected-Finance | L 2 | Rejected-Finance Bidder is not L1 bidder. |
Tender Value
₹22.1 L
EMD Value
₹27,600
Closing Date
15 Nov 2024, 11:00 amClosed
STAFF OFFICER EnM
CENTRAL WORKSHOP JAYNAT PO. JAYNAT DT. SINGRAULI , 486890
Annual repair and maintenance of LT Power Supply System within the Industrial and Administrative building of CWS Jayant.
2024_NCL_319922_1
NCL/CWS/EM/Tender/24/154 DATED 24.10.2024
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
CWS COMPLEX JAYANT
Please refer Tender documents.
5 documents required · 5 mandatory
₹27,600
5 Mar 2025
28 Oct 2024
16 Nov 2024
28 Oct 2024
15 Nov 2024
28 Oct 2024
28 Oct 2024 - 4 Nov 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH insulated copper conductor single core cable in surface / recessed high class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLSH insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/ high class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for light/ power plug with 2X4 sq. mm FRLSH insulated copper conductor single core cable in surface/high class PVC conduit alongwith 1 No. 4 sq. mm FRLSH insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSH insulated copper conductor, single core cable in surface/ recessed high class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supplying and fixing metal box of following size (nominal size) on surface or in recess or steel structure with suitable size of phenolic laminated sheet cover in front including painting etc. as required (100 mm X 100 mm X 60 mm deep)
Supplying and fixing metal box of following size (nominal size) on surface or in recess or steel structure with suitable size of phenolic laminated sheet cover in front including painting etc. as required (150 mm X 75 mm X 60 mm deep)
Supplying and fixing metal box of following size (nominal size) on surface or in recess or steel structure with suitable size of phenolic laminated sheet cover in front including painting etc. as required (200 mm X 250 mm X 75 mm deep)
Supplying and fixing Bell Push on the existing switch box/cover including connections etc. as required.
Supplying and fixing 5/6 A switch on the existing switch box/cover including connections etc. as required.
Supplying and fixing 15/16 A switch on the existing switch box/cover including connections etc. as required.
Supplying and fixing 3 pin 5/6 A socket outlet on the existing switch box/cover including connections etc. as required.
Supplying and fixing 6 pin 15/16 A socket outlet on the existing switch box/cover including connections etc. as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. L&T/Havells/Siemens 32 A TPN
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. L&T/Havells/Siemens 63 A TPN
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. L&T/Havells/Siemens 100 A TPN
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. L&T/Havells/Siemens 400 A TPN
Providing and fixing following rating and breaking capacity and MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. L&T/Havells/Siemens 100 A
Providing and fixing following rating and breaking capacity and MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. L&T/Havells/Siemens 400 A 35 KA
Providing and fixing following rating and breaking capacity and MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. L&T/Havells/Siemens 630 A 50 KA
Supplying and fixing following 6 way Double door, single pole and neutral sheet steel MCB distribution board 240 volts on surfcae/ recess complete with tinned copper bus bar neutral bus bar earth bar din bar interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) With all other required material for fixing
Supplying and fixing following 8 way Double door, single pole and neutral sheet steel MCB distribution board 240 volts on surfcae/ recess complete with tinned copper bus bar neutral bus bar earth bar din bar interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) With all other required material for fixing
Supplying and fixing following 12 way Double door, single pole and neutral sheet steel MCB distribution board 240 volts on surfcae/ recess complete with tinned copper bus bar neutral bus bar earth bar din bar interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) With all other required material for fixing
Supplying and fixing following 16 way Double door, single pole and neutral sheet steel MCB distribution board 240 volts on surfcae/ recess complete with tinned copper bus bar neutral bus bar earth bar din bar interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) With all other required material for fixing
Supplying and fixing 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. L&T/Havells/Siemens Single pole
Supplying and fixing 63 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. L&T/Havells/Siemens Two pole
Supplying and fixing 63 A rating, 240/415 V, 10 kA, "C" curve, isolator suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. L&T/Havells/Siemens Four pole isolator
Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top alongwith 20 A "C" curve SP, MCB in sheet steel enclosure on surface or in recess with chained metal cover for the socket out let and complete with connections testing and commissioning etc.as required L&T/Havells/Siemens
Supplying and fixing 20 A, 415 volts, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 20 A "C" curve TPMCB in sheet steel enclosure on surface or in recess with chained metal cover for the socket out let and complete with connections testing and commissioning etc.as required L&T/Havells/Siemens
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm made of mild steel at least 2 mm thick and enameled white on both sides and with inscription in single re colour on frount side as required.(Plate laminated with haveay duty retro reflecting sheet)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Nut Bolt washer different size as required
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable 1.1 KV grade of armoured cable size 4 Core 95 to 185 Sq mm direct in ground including excavtion, sand cushioning, protective covering and refilling the trench etc as required including proper connection of cable on the pole & main switch. (Cable supply by department)
Laying of one number PVC insulated and PVC sheathed/XLPE power cable 11 KV grade of following size (above 120 Sq mm to 400 sq mm) direct in ground including excavtion, sand cushioning, protective covering and refilling the trench etc as required including proper connection of cable on the pole & main switch or panels. (HT cable supply by department)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and sheathed / XLPE aluminium/ copper conductor cable of 1.1 KV grade as required. (Cable size 4 core x 95 sq. mm)
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all Accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 300 sq. mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all Accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. 300 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and sheathed / XLPE aluminium/ copper conductor cable of 11 KV grade as required. 300 Sq mm
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) for grouting of pole, road and drain repairing etc.
Supplying and fixing double pole (phase and netural) 240 volts residual current breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections testing and commissioning etc. as required., 63 A, 30 mA DP 240 volts L&T/Havells/Siemens
Supplying and fixing four pole (three phase and netural) 415 volts residual current breaker (RCCB) having a sensitivity current 100 mA in the existing MCB DB complete with connections testing and commissioning etc. as required., 63 A 100 mA four pole 415 volts L&T/Havells/Siemens
Providing and fixing of 195 x 140 x 65 size PVC junction box.
Providing and fixing of 225 x 205 x 65 size PVC junction box.
Providing and fixing of 320 x 220 x 65 size PVC junction box.
Providing and installation of Slim, compact, aluminum die cast back lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver(Havells Catllog Reference (12 W LED 6500 K LHEBAXP7IZ1W012) 12 Watt LED panel round light fittngs with round surface accessories)
Providing and installation of Slim, compact, aluminum die cast back lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver. (Havells Catllog Reference (15 W LED 6500 K LHEBAXP7IZ1W015) 15 Watt LED panel round light fittngs with round surface accessories)
Providing and installation of Slim, Compact, Aluminium die cast edge lit panel, Recess mounted square fixture with opal diffuser LED Panel Square (Havells Catllog Reference (LHEBAEP7IZ1W024) 24 Watt LED 6500 K panel light fittngs with all accessories) Ceiling cutout (284x284) mm, height 23 mm ±1 mm for 24 W
Providing and installation of LED 2X2 PANEL Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with armstrong/Grid ceiling (Havells Catllog Reference (LHEBAEP7IW1W036) 36 Watt LED 6500 K panel light fittngs with all accessories)
Total impact of GST for the purpose of CTC
BHASKAR ENTERPRISES (BID ID -1100360)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .