| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC RP IV 23 PUNNAKADAVU JN RAMANTHALI P O KANNUR 670308 | KANNUR | KANNUR | KERALA | 670308 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹19.3 L+₹31,817.50 (1.68%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹20.6 L+₹1.6 L (8.69%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹22.0 L+₹3.1 L (16.1%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹22.8 L+₹3.8 L (20.1%)Rejected-Finance THEKKEKOTTARAM RAMANTHALI PO KANNUR DIST KERALA 670 308 | RAMANTHALI | KANNUR | KERALA | 670308 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
12 May 2021, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2021_MES_436739_1
GE MAINT EZHIMALA 8373
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹50,000
Yes
14 Jun 2021
16 Apr 2021
14 May 2021
16 Apr 2021
12 May 2021
30 Apr 2021
17 Apr 2021 - 24 Apr 2021
Amount
Demolition of brickwork or precast cement concrete block masonry, built in cement mortar complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specially provided for complete all as specified and as directed.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including plinth protection complete all as specified and as directed.
Dismantling of existing precast RCC cover slabs and cleaning /removal of soil, vegetation etc.from the existing area drain upto 800mm width & 500 mm depth and depositing the same at a distance n exc. 500 RM from the work site and re positioning of RCC cover slabs and making good with CM 1:4 complete all as specified and as directed.
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and as directed.
M&L for PCC 1:4:8 type D2( using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for Pre-cast cement concrete block masonry type C1 1:3:6 (using 20 mm aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6) complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth using extra cement complete all as specified and as directed.
M&L for PCC Type B-0 (1:2:4) using 12.5 mm graded stone aggregate as in copings complete all as specified and as directed
M&L PCC 1:3:6 type C-1 (20mm graded stone aggregate) as in surface channels of drain including necessary form work and finishing the surface even and smooth using extra cement complete all as specified and as directed.
Demolition of cast iron or reinforced concrete drian pipes 100mm bore (SGSW/AC/RCC/PVC) set in cement mortar complete all as specified and as directed.
S&F in repair PVC (SWR) pipes 110 mm bore, single socketed,in any length as in waste pipe fixed with rubber ring joints laid in trenches complete all as specified and as directed.
All as per ser item No. 12 above but fixed to walls (Work in foul condition) complete all as specified and as directed.
S&F PVC (SWR) bends 110 mm bore with access door complete all as specified and as directed.
S&F PVC (SWR) branch piece,110mm bore single (single Y) equal or unequal with access door complete all as specified and as directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) concrete bed to drain pipes of dia 200 mm including packing under, and haunching against the sides of pipes after they are laid and tested in complete all as specified and as directed.
Supplying, laying, jointing and testing in trenches DWCPE (SN 8) nominal size 200 mm dia, 197.40 (ID)/230.50 (OD) dia as per IS-16098 (Part 2) : 2013 with and including all items and activities required to make sewer line functional complete all as specified and as directed.
Returning filling in including spreading levelling, watering and wall ramming in layers not exc 25cm,in hard/dense soil complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L precast RCC 1:2:4 type B1( using 20mm graded stone aggregate) as in cover slabs including casting of necessary form work set in cement mortar 1:4 complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F mild steel frame work such as grills, gratings etc. with ends of bar shouldered and/or riveted or forged into spikes, framed guard bars, ladders, framed brackets, etc and similar work conforming to Fe-290 of Gde E-165 complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 100mm to 150 mm dia of pipe complete all as specified and as directed.
M&L for cleaning of sewage lines 100 mm dia by roding or by sludge sucking machine and taking out sludge and water complete through manholes and burried the same at a distance n. exc. 500 mtrs from the manholes but away from wells/water storage tanks and spreading bleaching powder including necessary earth work etc. complete all as specified and as directed.
All as per ser item No. 26 above but for 150mm to 200mm dia pipes complete all as specified and as directed.
All as per ser item No. 26 above but for 250mm to 300mm dia pipes complete all as specified and as directed.
M&L for cleaning of manholes of depth n.exc 1.5mtrs including bailing /pumping out sludge, waste water etc complete and burried the same at a distance n. exc. 500 mtrs from the manholes but away from wells/water storage tanks and spreading bleaching powder including necessary earth work etc. complete all as specified and as directed.
All as per Sl item No. 29 above but for depth exc 1.5 mtr but n. exc 03 mtr complete all as specified and as directed.
All as per Sl item No. 29 above but for depth exc 03 mtr but n. exc 4.50 mtr complete all as specified and as directed.
M&L for cleaning of septic tank 25 users capacity by pumping out/bailing out sludge complete all as directed at site and making it free from any residual waste (solid/liquid whatsoever) and burried the same at a distance n. exc. 500 mtrs from the manholes but away from wells/water storage tanks and spreading bleaching powder including necessary earth work etc. complete all as specified and as directed.
All as per ser item No. 32 above but 50 users capacity complete all as specified and as directed.
M&L for cleaning of floor/nahani traps,removing any type of blockage and removing all rubbish obtained during cleaning away from the premises complete all as specified and as directed.
M&L for cleaning gully traps,removing any type of blockage and removing all rubbish obtained during cleaning away from the premises complete all as specified and as directed.
M&L for cleaning IWC/EWC traps,removing any type of blockage and removing all rubbish obtained during cleaning away from the premises complete all as specified and as directed.
M&L for cleaning of spout upto 110mm dia at terrace level (up to 10mtr height) including removal of vegetation, algae, dirt and grit complete all as specified and as directed.
M&L for cleaning of hume pipe up to 200 mm dia by roding or by auger or by any means and taking out mud, deposited soil etc. complete from hume pipes and deposited the same at a distance n. exc. 500 mtrs from the site complete all as specified and as directed.
All as per ser item No. 38 above but 200 to 450mm dia complete all as specified and as directed.
General Engineering and Constructions
Sreekrupa Enterprises
Jack Electrolinks Private Limited
Palace constructions
KDR CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .