Loading…
Loading…
Tender Value
₹10.3 L
EMD Value
₹11,000
Closing Date
22 Jun 2026, 6:00 pm2d left
Similar tender results from the same govt authority in the past 3 years.
Executive Engineer, R&B Division, Junagadh
Repairs to Mamlatdar Office at Bhesan, Ta. Bhesan, Dist. Junagadh (Provision of Fire Fighting System) (Group E : Business Building - Less than 10 M in height)
312089
35 of 2025-26
Open
Civil Works - Others
Junagadh
8 documents required · 6 mandatory · 2 optional
₹900
Executive Engineer, R & B Division, Junagadh.
₹11,000
6 Jun 2026
6 Jun 2026
6 Jun 2026
22 Jun 2026
6 Jun 2026
Name of Work :- Repairs to Mamlatdar Office at Bhesan, Ta. : Bhesan, Dist : Junagadh. ( Provision of
Fire Fighting System ) ( Group E : Business Building - Less than 10 M in height )
BILL OF QUANTITIES
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be In FiguresIn words according to
more or less. estimated
1 1.00 Supply Installing Testing & Commissioning of 7.50 46308.50 No
HP Monobloc pump 3 phase 400/440 volt, 454 LPM
Discharge, 24 meter head, 50 Hz AC Supply &
RPM as per IS 9079 at departmental stores with
following MOC: Casing: CI-FG260, Impeller: Bronze
& Shaft: SS:410 including all requirede fittings,
rubber ring, flange, nuts, bolts and labour etc complete
as directed and certified by Engineer in charge.
2 33.00 Supply Installing Testing & Commissioning of 100 3136.05 MTR
NB G.I. Pipe Class C, ISI Marked, Make : Asian,
Tata, Jindal, Supply Fabrication ( Including civil work
like making hole, soil remove etc.) Installation,
painting, Fitting ( i.e Elbows, Tee, Reducer Coupling
Flanges, Nipple etc.) with proper supports including
structural and civil costructed, Nut, Bolt and washer,
Gasket, Fabricated piping with fitting must be Tested
for any leakage and Hydraulically tested at 15kg/sqcm
and it must be satisfied and certified by Engineer in
3 1.00 Supply Installing Testing & Commissioning of 5226.75 No.
100mm Dia Double Flanged ISI-Mark C.I Sluice /
Butterfly Valve with gun metal / SS working
part,stainless steel spindal, Gasket, Nut Bolts, etc.
necessary complete.
4 1.00 Supply Installing Testing & Commissioning of 11673.08 No.
100mm Dia Double Flanged ISI-Mark C.I Non-
Return Valve with Gasket, Nut- Bolts, etc necessary
5 1.00 Supply Installing Testing Commissioning of 100mm 15157.58 No.
dia "Y" Type Stainer ISI-Mark with Gasket,Nut Bolts,
etc .necessary complete.
6 2.00 Supply Installing Testing & Commissioning of 1858.40 No.
25mm Dia ISI-Mark C.I Ball Valve with gun metal /
SS working part,stainless steel spindal, Gasket, Nut
Bolts, etc. necessary complete.
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be In FiguresIn words according to
more or less. estimated
7 1.00 25mm Dia Air Valve for Riseing Main Line. For 2555.30 No.
Air Release Including supply, Installing, Testing And
Commissioning etc. complete.
8 1.00 Supply Installing Testing & Commissioning of 1916.48 No.
Pressure Guage 100mm Dia. 1 % Accuracy Direct
Bottom 3/8” BSP connection In Brass Socket &
Range 0 to 16 Kg/Cm2 etc necessary
9 1.00 Supply Installing Testing & Commissioning of 6969.00 No.
63mm Dia C. I. TWO WAY FIRE BRIDGE Inlet
Valve with Gun-Metal Non-Return, Flange, Gasket,
Nut-Bolts, etc. Complete.
10 2.00 Providing and fixing FIRST AID HOSE REEL wall 9408.15 No.
mounting fix type having side of the hose reel made of
MS , providing with 30mtr long 25mm dia PVC nylon
braided flexible hose with S.S shut off nozzle of
approved quality etc complete as directed.
11 12.00 Supplying and Fixing 4.5 Kg Fire Extinguisher, CO2 8362.80 No.
Gas as per IS 15222 / ISI 15683 for fire classes BC
& Electrical Fire, Discharge Control mechanism fitted
with high pressure steel braided Discharge Hose and
Flat Horn with diffuser Nozzles for dispersed
discharge of CO2, internal coating not applicable &
external coating of enamel spray painting, Cylinders
construction: hot spinning seamless & bearing ISI
mark, confirm to IS 7285 and approved by EIC. Fire
Class 21B rating as per IS 15683 and ISI Mark.
12 12.00 Supplying and Fixing Fire Extinguisher as per IS : 7549.75 No.
15683 with ISI Marked, Type : ABC, Capacity :
kg, Fire Rating : 4A, Stored Pressure Type, Filled
with 50% Mono Ammonium Phosphate based multi
purpose Dry Powder suitable for Class A, B & C Fire,
Pressurized by Dry Nitrogen, Complete with all
respect with stand/wall mounting bracket
13 2.00 Supplying and Fixing Modular Wall Mounted ( with 12544.20 No.
brackets ) portable Clean Agent HFC-236fa 5 Kg gas
based Fire Extinguisher which leaves no residure
making it safe for use on sensitive equipment
Extinguisher performance tested by NABL accredited
Lab, MSDS of the Extinguishing agent is a must
current and valid BIS certification 15683 2006, EN
approved ISI and GE approved / Marked. LPCB
approved, EN:ISO:9001 & ISO 10002:2004 certified
with 3 years warranty ) ( in / near Electrical Panel
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be In FiguresIn words according to
more or less. estimated
14 4.00 Providing of FIRE BUCKET WITH STAND which 10453.50 No.
icludes a set of 4 nos buckets with Capacity 09Ltr and
a stand , G.I.24 Gauge, Painted Red & Marked
“FIRE” as directed.
15 1.00 Supplying, Installing, Testing and commissioning of 389822.63 No.
micro processor based intelligent addressable main
Loop FIRE ALARM CONTROL PANEL central
processing unit at all the Two floor with high intensity
Hooter and manual call point with hammer with the
following loop modules and capable of supporting
minimum 120 detectors per loop and length up to
km. Alarm panel contains Zone wise Fire Fault LED
indication, Zone isolation facility, mains on system
On, Charge on Visual indications. Auto Dialer
attached facility, External switch for reset, silence,
Lamptest, External Switch to test each zone fire, open -
short status manually, inbuilt Buzzer, inbuilt battery
charger & battery spaces. Operates on 230v AC,
HZ AC supply Fire alarm panel with resettable 02 nos
of manual call point for use in case of emergency for
activate the fire alarm system connected with 2 nos
sounders and 70 nos of smoke detectors with base to
address emergency.
16 1.00 On/Off switch with pipe & 3c x 1 sq mm cable wiring 3850.23 No.
17 8.00 Providing & Fixing of Retroreflective High intensity 1445.83 No.
grade on Acrylic plate of size 450mm 150mm made
of 3 mm thick Acrylic name plate with lettering using
High intensity grade retro reflctive letters, incl. fixing
on each chamber as directed & Instructed by Engineer-
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be In FiguresIn words according to
more or less. estimated
18 1200.00 Supplying and Fixing of MARKING STRIPS are 6.97 Sq. Cm
broadly used on the roads, parking lots and many
more places by manufacturer / dealer to help/provide
the right directions to the people in making fast and
immediate movement from the hazardous places.
Marking strips for stairs & walls : 120 x 5.7 cm size.
These strips are designed with the help of premium
quality basic material. It should have water proof,
Tear resistance, precisely designed, made of : Photo
luminescent rig-id plastic, 2 mm thickness, printed on
high quality gloss paint with UV resistance, Material
used : Non-Radioactive, non-phosphorous, non-toxic
and lead free, Time after removing the light source:
minutes, Luminescent intensity : 30 med/sqm,
Luminescent intensity greater than 0.32 mcd/sqm,
period of light decay : 3100 minutes with 5 years
19 90.00 Supply, laying, testing & commissioning 1.1 kV 145.44 MTR
grade, XLPE insulated, stranded Aluminium
conductor, galvanised steel flat strip / round wire
armoured, extruded PVC type ST2 sheathed, heavy
duty cable (to be laid on wall surface with necessary
clamps / in existing cable trench / cable trays / conduit
/ pipe sleeves at road crossing or floor as per site
requirement) conforming to IS:7098 (Part-1) &
IEC:60502 (Part-1) of following sizes: (g) 3 Core x
20 1.00 Supplying & Installation PRESSURE GUAGE of 150 2903.75 No.
mm dia. 0-21 Kg/cm2 fitted with 12/15 mm dia pad
cock valve and G.I. elbow etc. complete as required.
21 90.00 Providing and erecting IPVC insulated flat 124.23 MTR
submersible cable as per detailed technical
specifications of R/C of GWSSB conforming to IS
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be In FiguresIn words according to
more or less. estimated
22 1.00 Supplying & erecting approved make motor 13557.23 Job
CONTROL CUBICAL PANEL DOL / Star Delta
starter suitable for local & remote pump control
application consisting of MPCB, overload relay and
contactors as per Type II coordination including
digital voltmeter, analogue ammeter with selector
switch, run hour meter, required protective relays &
control accessories. [C] D.O.L. up to 7.50 HP
including Providing dust and vermin proof MS cabin
having two compartments, one for panel board and
other for energy meter and fuse unit with required
locking arrangement , minimum degree of protection
IP 52 as per IS 2147 fabricated from CRCA sheer
steel minimum thickness for base frame / channel /
gland plates for 3 mm for load bearing members,1.6
mm for ineternal members of size 0600m x 0.70 m x
23 10000.00 Providing erecting and fixing tripple coated PVC 10.12 Litre
WATER TANK of required capacity each including
necessary transportation to the site, making plateform
with matching flooring to the terrace, fixing fitting
and connecting to inlet and outlet with all necessary
fittings & connection complete on terrace.
24 12.00 Providing laying and jointing in true line and level 91.84 MTR
25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including as approved by Engineer In Charge. Pipe
shall be fixed on the wall with the help of clamp at
every two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing of
pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
25 2.00 Providing and Fixing 25mm dia PVC Heavy Duty 714.32 No.
valve of approved quality with required fitting and
adhesive incl. fixing the same with new or existing
line as directed by EIC.
" I / We Am / Are willing to carry out the work @ __________ % @
(should be written in Figures and Words) of the estimated rates mentioned above, Amount of
My / Our tender works out as under :-
Estimated Amount Put to tender. Estimated Amount Put to tender.
Add. _______ % Above Rs. ____________ Deduct _______ % Below Rs. __________
It. Qty Estimated Item of work Estimated rate Unit Total Amount
It. Qty Estimated Item of work Estimated rate Unit Total Amount
No but may be In FiguresIn words according to
more or less. estimated
In Words In Words
1 All work shall be carried out as per P.W.D. Hand Book and other specification of the Division or as directed.
2 Rates quoted include clearance of site (prior commencement of work and at its close) in all respects and hold good for work under all conditions, site
moisture, weather etc.
3 The contractor shall exhibit the details of work, tender amount, specifications as per Govt. circular No. BDG / 3277 / 1657 Dated. 26-4-1978 and G.R. No.
TNC/ 1090-24 C, Dated. 18-11-91 as directed by the Engineer-in-charge on the work site for which contractor
4 Testing of materials as per statement attached with the specifications. The materials shall be tested in G.E.R.I. Bill for testing shall be paid by the department
and 1 % (One percentage) of amount put to tender after deduction the cost of cement & steel mentioned in clause 59(a)
5 In R.C.C. item where there is change of grade mix or change as per actual mix design the difference of of cement consumption shall be added / deducted from
rate of original item at the rate mentioned in tender.
6 For earthquake resistance provision the works shall be carried cut as per the instruction of Engineer in charge.
7 The other conditions of Schedule "B" will remain unchanged.
8 Labor Cess 1 % (One Percent) of Bill Amount shall be recovered from contractor of building or other construction works. (Resolution of Employment and
condition Act 1996)
Signature of Contractor Executive Engineer
Special Condition for Fire System
Repairs to Mamlatdar Office at Bhesan, Ta. : Bhesan, Dist : Junagadh. ( Provision of Fire
Fighting System ) ( Group E : Business Building - Less than 10 M in height )
1 Contractor is expected to have visited the site and gets to know about the existing structures in and
around the Site.
2 Laboratory for material test shall be approved from Engineer in charge prior to execute the work. And
in Civil Items 10 % of Total Material Testing Should be done in GERI.
3 The client reserves the right to select the manufacturer or approved make from the list, no change to be
permitted in this make during the execution of the contract.
4 The water for construction, drinking and other use, shall be arranged by the contractor at his own cost.
Similarly, arrangement for electricity for construction / domestic use shall be arranged by the
contractor and no claim of this account shall be entertained.
5 No deviation from the approved list of makes shall be permitted. In case, certain items of Equivalent is
mentioned, the same shall be got approved from Engineer in charge before ordering.
6 The contractor has to barricade the premises with steel pipes and steel sheets within week from the
commencement of work.
7 The Contractor has to design and work accordingly NBC/CGDCR and also prepared the
Submission drawing for Fire NOC. It will be Completely responsibility of contractor for Final
Fire NOC and Renewal of Fire NOC Up to Five Years. All Expenses for Fire NOC and Renewal
of Fire NOC should be bearer by the contractor. And also checking and maintain the pumps,
sprinklers, Smoke Detection System at quarterly Interval Up to Five Years.
8 The Agency has to carry out the maintenance of above said Work for the period of Five Years.
9 The Tenderer shall study the project information in brief. The project information in brief is meant only to give
the general guidelines to the Tenderer about the project and is not for execution. The tender drawings may
undergo a complete change. The Contractor shall make his own arrangements to unload, transport and stack the
material in his godown at his own cost. He shall take the material into his safe custody only after inspection and
verification of the quality and the quantity of the material received by the EIC/Consultant. The Contractor shall
make his own independent arrangement to procure all other materials required to complete the work.
10 The installation shall be in conformity with the bye-laws, regulations and standards of the local authorities
concerned; in so far these become applicable to the installation. But if these specifications and drawings call for a
higher standard of materials and / or workmanship than those required by any of the above regulations and
standards, then these specifications and drawings shall take precedence over the said regulations and standards.
However, if the drawings and specifications require something which violates the bye-laws and regulations, then
the bye-laws and regulations shall govern the requirement of this installation.
11 The contractor shall obtain all permits / licenses and pay for any and all fees required for the inspection, approval
and commissioning of their installation if required
Scope of work for Civil, Electric & Fire Fighting work
1 Design, Supply, Installation, Testing, Commissioning and comprehensive maintenance of Fire Fighting
System. The agency has to repair / replace all the equipment within 72 hours after receipt of the
complaint, Failing which penalty will be imposed as per tender terms and condition, This is
comprehensive maintenance period for Five years, hence the agency has to perform all civil, electrical
and mechanical activities including labor and martial during the performance period without any extra
2 It is comprehensive maintenance so all the equipment’s guaranty must be without any terms and
condition and in any fault any defect raise in the all-electrical live parts, The agency must be repaired /
replace with supply, installation, transport, taxes, loading and unloading work
3 The contractor shall have to give Five years free maintenance guarantee period from the certified date
of completion. During this period Agency shall have to repair/ replaced the damaged/ installed portion
of Electrical/Fire Equipment Work of the specially Items under guaranty period at his risk and cost as
per direction of the Engineer-in-charge.
4 Five percent of total project cost shall be withheld and will be released after the free maintenance
guarantee period (i.e. Five years) is over.
Fire Fighting work Maintenance during defects liability period
The contractor shall receive calls for any and all problems experienced in the operation of the system
under this contract, attend to these within 12 hours of receiving the complaints and shall take steps to
immediately correct any deficiency that may exist.
All equipment that requires repairing shall be immediately serviced and repaired.
Since the period of maintenance runs for five years concurrently withheld defects liability period, all
replacement parts and labour and consumables shall be supplied promptly free of charge to the owner.
3 Uptime Guarantee
The contractor shall guarantee for the installed system an uptime of 99 %. In case of shortfall in any
month during the defects liability period, the defects liability period shall be get extended by a month
for every month having shortfall. In case of shortfall beyond the defects liability period, the contract
for operation and maintenance shall get extended by a month for every month having shortfall and no
reimbursement shall be made for the extended period.
Each tenderer shall submit along with the tender a detailed operation assistance proposal for the
owners site representatives / consultants review. This shall include the type of service planned to be
offered during defects liability period and beyond
4 Penalty for Late Maintenance: -
The contractor shall receive calls for any and all problems of the system under this contract, attend to
these calls within 12 hours of receiving the complaints and shall take steps to immediately correct any
deficiency that may exist. If The Contractor does not respond in above timeline than Penalty Charge
For Late maintenance should be cut from his security deposit as 2500 Rs/day till the responding. If The
Contractor does not able to do repairing work in given time line than in that case the client has to
authority to do maintenance with other agency and give his fee from the contractor’s security deposit
and additional 2 times the fee as penalty charge.
Deputy Executive Engineer Executive Engineer
City R&B Sub-Division R & B Division
Junagadh Junagadh
Name of Repairs to Mamlatdar Office at Bhesan, Ta. : Bhesan, Dist :
Work: Junagadh. ( Provision of Fire Fighting System ) ( Group E :
Business Building - Less than 10 M in height )
Component of Work for Price Variation
Cement Component
Steel Component
Asphalt Component
Other Material Component
Labour Component
Plant and Machinary Component
Deputy Executive Engineer Executive Engineer
City R&B Sub-Division R & B Division
Junagadh Junagadh
Repairs to Mamlatdar Office at Bhesan, Ta. : Bhesan, Dist : Junagadh. ( Provision of Fire Basic Rate ( SOR 2023-24 ) ( Cement 5.234 & TMT Bar FE 500D = 59.42 )
Fighting System ) ( Group E : Business Building - Less than 10 M in height )
Component of Work for Price Variation
Sr. Qty. Item of Work Estimated Unit Total Cement Component Steel Component Asphalt Other Material Labour Component Plant and POL
No. Rate Amount Component Component Machinary
Consumption Amount Consumptio Amount Consum Amount % Amount % Amount % Amount % Amount
Commissioning of 7.50 HP
Monobloc pump 3 phase 400/440
volt, 454 LPM Discharge, 24 meter
head, 50 Hz AC Supply & 2800 RPM
as per IS 9079 at departmental
stores with following MOC: Casing:
CI-FG260, Impeller: Bronze & Shaft:
SS:410 including all requirede
fittings, rubber ring, flange, nuts,
bolts and labour etc complete as
directed and certified by Engineer in
Commissioning of 100 NB G.I. Pipe
Class C, ISI Marked, Make : Asian,
Tata, Jindal, Supply Fabrication (
Including civil work like making
hole, soil remove etc.) Installation,
painting, Fitting ( i.e Elbows, Tee,
Reducer Coupling Flanges, Nipple
etc.) with proper supports including
structural and civil costructed, Nut,
Bolt and washer, Gasket, Fabricated
piping with fitting must be Tested
for any leakage and Hydraulically
tested at 15kg/sqcm and it must be
satisfied and certified by Engineer in
Commissioning of 100mm Dia
Double Flanged ISI-Mark C.I Sluice
/ Butterfly Valve with gun metal /
SS working part,stainless steel
spindal, Gasket, Nut Bolts, etc.
necessary complete.
Commissioning of 100mm Dia
Double Flanged ISI-Mark C.I Non-
Return Valve with Gasket, Nut-
Bolts, etc necessary
Sr. Qty. Item of Work Estimated Unit Total Cement Component Steel Component Asphalt Other Material Labour Component Plant and POL
No. Rate Amount Component Component Machinary
Consumption Amount Consumptio Amount Consum Amount % Amount % Amount % Amount % Amount
Commissioning of 100mm dia "Y"
Type Stainer ISI-Mark with
Gasket,Nut Bolts, etc .necessary
Commissioning of 25mm Dia ISI-
Mark C.I Ball Valve with gun metal /
SS working part,stainless steel
spindal, Gasket, Nut Bolts, etc.
necessary complete.
Main Line. For Air Release
Including supply, Installing, Testing
And Commissioning etc. complete.
Commissioning of Pressure Guage
100mm Dia. 1 % Accuracy Direct
Bottom 3/8” BSP connection In
Brass Socket & Range 0 to
Kg/Cm2 etc necessary
Commissioning of 63mm Dia C. I.
TWO WAY FIRE BRIDGE Inlet Valve
with Gun-Metal Non-Return,
Flange, Gasket, Nut-Bolts, etc.
REEL wall mounting fix type having
side of the hose reel made of MS
providing with 30mtr long 25mm
dia PVC nylon braided flexible hose
with S.S shut off nozzle of approved
quality etc complete as directed.
Sr. Qty. Item of Work Estimated Unit Total Cement Component Steel Component Asphalt Other Material Labour Component Plant and POL
No. Rate Amount Component Component Machinary
Consumption Amount Consumptio Amount Consum Amount % Amount % Amount % Amount % Amount
Extinguisher, CO2 Gas as per IS
15222 / ISI 15683 for fire classes BC
& Electrical Fire, Discharge Control
mechanism fitted with high
pressure steel braided Discharge
Hose and Flat Horn with diffuser
Nozzles for dispersed discharge of
CO2, internal coating not applicable
& external coating of enamel spray
painting, Cylinders construction:
hot spinning seamless & bearing ISI
mark, confirm to IS 7285 and
approved by EIC. Fire Class 21B
rating as per IS 15683 and ISI Mark.
Extinguisher as per IS : 15683 with
ISI Marked, Type : ABC, Capacity :
06 kg, Fire Rating : 4A, Stored
Pressure Type, Filled with 50%
Mono Ammonium Phosphate based
multi purpose Dry Powder suitable
for Class A, B & C Fire, Pressurized
by Dry Nitrogen, Complete with all
respect with stand/wall mounting
Mounted ( with brackets ) portable
Clean Agent HFC-236fa 5 Kg gas
based Fire Extinguisher which
leaves no residure making it safe for
use on sensitive equipment
Extinguisher performance tested by
NABL accredited Lab, MSDS of the
Extinguishing agent is a must
current and valid BIS certification
15683 2006, EN approved ISI and
GE approved / Marked. LPCB
approved, EN:ISO:9001 & ISO
10002:2004 certified with 3 years
warranty ) ( in / near Electrical Panel
STAND which icludes a set of 4 nos
buckets with Capacity 09Ltr and a
stand , G.I.24 Gauge, Painted Red &
Marked “FIRE” as directed.
Sr. Qty. Item of Work Estimated Unit Total Cement Component Steel Component Asphalt Other Material Labour Component Plant and POL
No. Rate Amount Component Component Machinary
Consumption Amount Consumptio Amount Consum Amount % Amount % Amount % Amount % Amount
commissioning of micro processor
based intelligent addressable main
01 Loop FIRE ALARM CONTROL
PANEL central processing unit at all
the Two floor with high intensity
Hooter and manual call point with
hammer with the following loop
modules and capable of supporting
minimum 120 detectors per loop
and length up to 1.10 km. Alarm
panel contains Zone wise Fire Fault
LED indication, Zone isolation
facility, mains on system On, Charge
on Visual indications. Auto Dialer
attached facility, External switch for
reset, silence, Lamptest, External
Switch to test each zone fire, open -
short status manually, inbuilt
Buzzer, inbuilt battery charger &
battery spaces. Operates on 230v
AC, 50 HZ AC supply Fire alarm
panel with resettable 02 nos of
manual call point for use in case of
emergency for activate the fire
alarm system connected with 2 nos
sounders and 70 nos of smoke
detectors with base to address
mm cable wiring ISI mark.
High intensity grade on Acrylic
plate of size 450mm 150mm made
of 3 mm thick Acrylic name plate
with lettering using High intensity
grade retro reflctive letters, incl.
fixing on each chamber as directed
& Instructed by Engineer- in- Charge.
Sr. Qty. Item of Work Estimated Unit Total Cement Component Steel Component Asphalt Other Material Labour Component Plant and POL
No. Rate Amount Component Component Machinary
Consumption Amount Consumptio Amount Consum Amount % Amount % Amount % Amount % Amount
STRIPS are broadly used on the Cm
roads, parking lots and many more
places by manufacturer / dealer to
help/provide the right directions to
the people in making fast and
immediate movement from the
hazardous places. Marking strips for
stairs & walls : 120 x 5.7 cm size.
These strips are designed with the
help of premium quality basic
material. It should have water
proof, Tear resistance, precisely
designed, made of : Photo
luminescent rig-id plastic, 2 mm
thickness, printed on high quality
gloss paint with UV resistance,
Material used : Non-Radioactive,
non-phosphorous, non-toxic and
lead free, Time after removing the
light source: 60 minutes,
Luminescent intensity :
med/sqm, Luminescent intensity
greater than 0.32 mcd/sqm, period
of light decay : 3100 minutes with
years warranty.
commissioning 1.1 kV grade, XLPE
insulated, stranded Aluminium
conductor, galvanised steel flat strip
/ round wire armoured, extruded
PVC type ST2 sheathed, heavy duty
cable (to be laid on wall surface
with necessary clamps / in existing
cable trench / cable trays / conduit /
pipe sleeves at road crossing or
floor as per site requirement)
conforming to IS:7098 (Part-1) &
IEC:60502 (Part-1) of following
sizes: (g) 3 Core x 35 Sqmm
GUAGE of 150 mm dia. 0-21 Kg/cm2
fitted with 12/15 mm dia pad cock
valve and G.I. elbow etc. complete
insulated flat submersible cable as
per detailed technical specifications
of R/C of GWSSB conforming to IS
Sr. Qty. Item of Work Estimated Unit Total Cement Component Steel Component Asphalt Other Material Labour Component Plant and POL
No. Rate Amount Component Component Machinary
Consumption Amount Consumptio Amount Consum Amount % Amount % Amount % Amount % Amount
make motor CONTROL CUBICAL
PANEL DOL / Star Delta starter
suitable for local & remote pump
control application consisting of
MPCB, overload relay and
contactors as per Type II
coordination including digital
voltmeter, analogue ammeter with
selector switch, run hour meter,
required protective relays & control
accessories. [C] D.O.L. up to 7.50 HP
including Providing dust and vermin
proof MS cabin having two
compartments, one for panel board
and other for energy meter and
fuse unit with required locking
arrangement , minimum degree of
protection IP 52 as per IS
fabricated from CRCA sheer steel
minimum thickness for base frame /
channel / gland plates for 3 mm for
load bearing members,1.6 mm for
ineternal members of size 0600m x
coated PVC WATER TANK of
required capacity each including
necessary transportation to the site,
making plateform with matching
flooring to the terrace, fixing fitting
and connecting to inlet and outlet
with all necessary fittings &
connection complete on terrace.
line and level 25mm dia. U.P.V.C.
Pipe ( SCH- 40) for cold water
including as approved by Engineer
In Charge. Pipe shall be fixed on the
wall with the help of clamp at every
two metre C/C or shall be concelled
as directed including necessary
fittings etc. including testing of pipe
and joints and fixing the same with
adhesive solvent, including cost of
Sr. Qty. Item of Work Estimated Unit Total Cement Component Steel Component Asphalt Other Material Labour Component Plant and POL
No. Rate Amount Component Component Machinary
Consumption Amount Consumptio Amount Consum Amount % Amount % Amount % Amount % Amount
Heavy Duty valve of approved
quality with required fitting and
adhesive incl. fixing the same with
new or existing line as directed by
Percentage Component… 0.00 0.00 0.00 89.71 9.26 0.13
Assistant Engineer Deputy Executive Engineer Executive Engineer
City R&B Sub-Division City R&B Sub-Division R & B Division
Junagadh Junagadh Junagadh
Repairs to Mamlatdar Office at Bhesan, Ta. : Bhesan, Dist : Junagadh. ( Provision of
Fire Fighting System ) ( Group E : Business Building - Less than 10 M in height )
-- : NOTE OF SCHEDULE "B" : --
[1] All the work shall be carried out as per Public Work Department hand book and MOST &
Other specification this documents or as directed.
[2] All the columns in the Schedule "B" should be filled in ink and the total in entire in the last
columns should be struck by the contractor.
[3] Rate quoted including clearance of site (Prior to commencement of work and its close) in all
respect and hold good for work as under the all condition of site moisture weather etc.
[4] The contractor shall exhibit a Board as per Govt. No. 806/3277/1657 Dt. 26/04/78 {Guj.}
RGR-No. TNC-1090/24/C dated 29/11/90 and GR Dt. 18/11/91 involved at site without any
payment as directed by Engineer in charge.
[5] The contractor shall state even "Nil" percentage if no reduction offered.
[6] One percent of Bill Amount shall be recovered from the contract payments as "Labour
cess" in terms of Gujarat Govt. Gazette extra ordinary dated 12/12/2004 implementions of
building and other construction workers regulat.
[7] In RCC Items where there is change of grade mix or change as per actual mix design the
difference of cement consumption shall be deducted from rate of original item as per rate
mentioned in the tender.
Signature of Contractor Executive Engineer
Name of Work :- Repairs to Mamlatdar Office at Bhesan, Ta. : Bhesan, Dist : Junagadh. (
Provision of Fire Fighting System ) ( Group E : Business Building - Less
than 10 M in height )
CEMENT CONSUMPTION
SCH-B It. Qty Item of work Cement Per Total cement qty
no Required in in Kgs
Deputy Executive Engineer Executive Engineer
City R&B Sub-Division R & B Division
Junagadh Junagadh
Repairs to Mamlatdar Office at Bhesan, Ta. : Bhesan, Dist : Junagadh. ( Provision of Fire
Fighting System ) ( Group E : Business Building - Less than 10 M in height )
Steel Consuption Statement
Item.No. Item of Work Total Qty. Unit Total Qty.
Deputy Executive Engineer Executive Engineer
City R&B Sub-Division R & B Division
Junagadh Junagadh
Repairs to Mamlatdar Office at Bhesan, Ta. : Bhesan, Dist : Junagadh. ( Provision of Fire Fighting
System ) ( Group E : Business Building - Less than 10 M in height )
Item No. of Sch-B Item of Work Sr. No. of applicable specification
1 Supply Installing Testing & Commissioning of 7.50 HP Monobloc pump 3 phase 400/440 volt, 454 LPM As per separate sheet attached
Discharge, 24 meter head, 50 Hz AC Supply & 2800 RPM as per IS 9079 at departmental stores with
following MOC: Casing: CI-FG260, Impeller: Bronze & Shaft: SS:410 including all requirede fittings,
rubber ring, flange, nuts, bolts and labour etc complete as directed and certified by Engineer in charge.
2 Supply Installing Testing & Commissioning of 100 NB G.I. Pipe Class C, ISI Marked, Make : Asian, As per separate sheet attached
Tata, Jindal, Supply Fabrication ( Including civil work like making hole, soil remove etc.) Installation,
painting, Fitting ( i.e Elbows, Tee, Reducer Coupling Flanges, Nipple etc.) with proper supports including
structural and civil costructed, Nut, Bolt and washer, Gasket, Fabricated piping with fitting must be
Tested for any leakage and Hydraulically tested at 15kg/sqcm and it must be satisfied and certified by
Engineer in charge.
3 Supply Installing Testing & Commissioning of 100mm Dia Double Flanged ISI-Mark C.I Sluice / As per separate sheet attached
Butterfly Valve with gun metal / SS working part,stainless steel spindal, Gasket, Nut Bolts, etc. necessary
4 Supply Installing Testing & Commissioning of 100mm Dia Double Flanged ISI-Mark C.I Non-Return As per separate sheet attached
Valve with Gasket, Nut- Bolts, etc necessary
5 Supply Installing Testing Commissioning of 100mm dia "Y" Type Stainer ISI-Mark with Gasket,Nut As per separate sheet attached
Bolts, etc .necessary complete.
6 Supply Installing Testing & Commissioning of 25mm Dia ISI-Mark C.I Ball Valve with gun metal / SS As per separate sheet attached
working part,stainless steel spindal, Gasket, Nut Bolts, etc. necessary complete.
7 As per separate sheet attached
25mm Dia Air Valve for Riseing Main Line. For Air Release Including supply, Installing, Testing
And Commissioning etc. complete.
8 Supply Installing Testing & Commissioning of Pressure Guage 100mm Dia. 1 % Accuracy Direct As per separate sheet attached
Bottom 3/8” BSP connection In Brass Socket & Range 0 to 16 Kg/Cm2 etc necessary
9 Supply Installing Testing & Commissioning of 63mm Dia C. I. TWO WAY FIRE BRIDGE Inlet As per separate sheet attached
Valve with Gun-Metal Non-Return, Flange, Gasket, Nut-Bolts, etc. Complete.
10 Providing and fixing FIRST AID HOSE REEL wall mounting fix type having side of the hose reel made As per separate sheet attached
of MS , providing with 30mtr long 25mm dia PVC nylon braided flexible hose with S.S shut off nozzle
of approved quality etc complete as directed.
11 Supplying and Fixing 4.5 Kg Fire Extinguisher, CO2 Gas as per IS 15222 / ISI 15683 for fire classes As per separate sheet attached
BC & Electrical Fire, Discharge Control mechanism fitted with high pressure steel braided Discharge
Hose and Flat Horn with diffuser Nozzles for dispersed discharge of CO2, internal coating not applicable
& external coating of enamel spray painting, Cylinders construction: hot spinning seamless & bearing ISI
mark, confirm to IS 7285 and approved by EIC. Fire Class 21B rating as per IS 15683 and ISI Mark.
12 Supplying and Fixing Fire Extinguisher as per IS : 15683 with ISI Marked, Type : ABC, Capacity : 06 kg, As per separate sheet attached
Fire Rating : 4A, Stored Pressure Type, Filled with 50% Mono Ammonium Phosphate based multi
purpose Dry Powder suitable for Class A, B & C Fire, Pressurized by Dry Nitrogen, Complete with all
respect with stand/wall mounting bracket
13 Supplying and Fixing Modular Wall Mounted ( with brackets ) portable Clean Agent HFC-236fa 5 Kg gas As per separate sheet attached
based Fire Extinguisher which leaves no residure making it safe for use on sensitive equipment
Extinguisher performance tested by NABL accredited Lab, MSDS of the Extinguishing agent is a must
current and valid BIS certification 15683 2006, EN approved ISI and GE approved / Marked. LPCB
approved, EN:ISO:9001 & ISO 10002:2004 certified with 3 years warranty ) ( in / near Electrical Panel
14 Providing of FIRE BUCKET WITH STAND which icludes a set of 4 nos buckets with Capacity 09Ltr As per separate sheet attached
and a stand , G.I.24 Gauge, Painted Red & Marked “FIRE” as directed.
15 Supplying, Installing, Testing and commissioning of micro processor based intelligent addressable main As per separate sheet attached
01 Loop FIRE ALARM CONTROL PANEL central processing unit at all the Two floor with high
intensity Hooter and manual call point with hammer with the following loop modules and capable of
supporting minimum 120 detectors per loop and length up to 1.10 km. Alarm panel contains Zone wise
Fire Fault LED indication, Zone isolation facility, mains on system On, Charge on Visual indications.
Auto Dialer attached facility, External switch for reset, silence, Lamptest, External Switch to test each
zone fire, open - short status manually, inbuilt Buzzer, inbuilt battery charger & battery spaces. Operates
on 230v AC, 50 HZ AC supply Fire alarm panel with resettable 02 nos of manual call point for use in case
of emergency for activate the fire alarm system connected with 2 nos sounders and 70 nos of smoke
detectors with base to address emergency.
16 On/Off switch with pipe & 3c x 1 sq mm cable wiring ISI mark. As per separate sheet attached
17 Providing & Fixing of Retroreflective High intensity grade on Acrylic plate of size 450mm 150mm made As per separate sheet attached
of 3 mm thick Acrylic name plate with lettering using High intensity grade retro reflctive letters, incl.
fixing on each chamber as directed & Instructed by Engineer- in- Charge.
18 Supplying and Fixing of MARKING STRIPS are broadly used on the roads, parking lots and many more As per separate sheet attached
places by manufacturer / dealer to help/provide the right directions to the people in making fast and
immediate movement from the hazardous places. Marking strips for stairs & walls : 120 x 5.7 cm size.
These strips are designed with the help of premium quality basic material. It should have water proof,
Tear resistance, precisely designed, made of : Photo luminescent rig-id plastic, 2 mm thickness, printed on
high quality gloss paint with UV resistance, Material used : Non-Radioactive, non-phosphorous, non-toxic
and lead free, Time after removing the light source: 60 minutes, Luminescent intensity : 30 med/sqm,
Luminescent intensity greater than 0.32 mcd/sqm, period of light decay : 3100 minutes with 5 years
19 Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Aluminium conductor, As per separate sheet attached
galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to
be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe
sleeves at road crossing or floor as per site requirement) conforming to IS:7098 (Part-1) & IEC:60502
(Part-1) of following sizes: (g) 3 Core x 35 Sqmm
20 Supplying & Installation PRESSURE GUAGE of 150 mm dia. 0-21 Kg/cm2 fitted with 12/15 mm dia As per separate sheet attached
pad cock valve and G.I. elbow etc. complete as required.
21 Providing and erecting IPVC insulated flat submersible cable as per detailed technical specifications of As per separate sheet attached
R/C of GWSSB conforming to IS 694, IEC 60227 / 60228. (C) 3 Core x 4 Sq. mm.
22 Supplying & erecting approved make motor CONTROL CUBICAL PANEL DOL / Star Delta starter As per separate sheet attached
suitable for local & remote pump control application consisting of MPCB, overload relay and contactors
as per Type II coordination including digital voltmeter, analogue ammeter with selector switch, run hour
meter, required protective relays & control accessories. [C] D.O.L. up to 7.50 HP including Providing
dust and vermin proof MS cabin having two compartments, one for panel board and other for energy
meter and fuse unit with required locking arrangement , minimum degree of protection IP 52 as per IS
2147 fabricated from CRCA sheer steel minimum thickness for base frame / channel / gland plates for
mm for load bearing members,1.6 mm for ineternal members of size 0600m x 0.70 m x 040 m
23 Providing erecting and fixing tripple coated PVC WATER TANK of required capacity each including As per separate sheet attached
necessary transportation to the site, making plateform with matching flooring to the terrace, fixing fitting
and connecting to inlet and outlet with all necessary fittings & connection complete on terrace.
24 Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water As per separate sheet attached
including as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at
every two metre C/C or shall be concelled as directed including necessary fittings etc. including testing of
pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
25 Providing and Fixing 25mm dia PVC Heavy Duty valve of approved quality with required fitting and As per separate sheet attached
adhesive incl. fixing the same with new or existing line as directed by EIC.
Signature of Contractor Executive Engineer
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1 GR.pdf
2 GR.pdf
3 GR.pdf
4 GR.pdf
5 G R.pdf
6 G R.pdf
7 G R.pdf
Building Specification Part-I.pdf
Building Specification Part-III.pdf
Building Specification Part-II.pdf
E Tender Notice.pdf
SBD.pdf
Additional Specification.pdf
BOQ and Important Conditions.pdf
TOR.pdf
BOQ.pdf