| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 CrAccepted-Finance | ₹28.0 Cr | L1 | Accepted-Finance Less in Estimate Rate |
| 2 | L2₹29.4 CrRejected-Finance | ₹29.4 Cr | L2 | Rejected-Finance Above in Estimate Rate |
| 3 | Rejected-Technical NO 1 80 1ST FLOOR CHELLAMMAL PANDIYAN ILLAM 3RD STREET SATHYAVATHY NAGAR PADI NEAR BSNL CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | - | - | Rejected-Technical Technically Not Qualified. Not full filled the Bid Document Conditions |
| Sl No | Description | Qty | Unit | Shiva Engineering Work L1 | VOLGA POWER INDIA PRIVATE LIMITED L2 |
|---|---|---|---|---|---|
| 1.00 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum | 2,811 | Cum | 215 ₹6.0 L | 225 ₹6.3 L |
| 2.00 | Earthwork Excavation for Pipe Laying Works Having Bed Width 0.75m and 1.05m Depth for 150mm DI Pipes TWAD SOR WD-W0664 | 10,000 | Mtr | 254 ₹25.4 L | 267 ₹26.7 L |
| 3.00 | Refilling for Pipe Laying Works Having Bed Width 0.75m and 1.05m Depth for 150mm DI Pipes TWAD SOR WD-W0664 | 10,000 | Mtr | 34 ₹3.4 L | 36 ₹3.6 L |
| 4.00 | Earthwork Excavationfor Pipe Laying Works Having Bed Width 0.8m and 1.05m Depth for 200mm DI Pipes TWAD SOR WD-W0665 | 13,200 | Mtr | 283 ₹37.4 L | 297 ₹39.2 L |
| 5.00 | Refilling for Pipe Laying Works Having Bed Width 0.8m and 1.05m Depth for 200mm DI Pipes TWAD SOR WD-W0665 | 13,200 | Mtr | 38 ₹5.0 L | 39 ₹5.1 L |
| 6.00 | Earthwork Excavation for Pipe Laying Works Having Bed Width 0.8m and 1.05m Depth for 250mm DI Pipes TWAD SOR WD-W0666 | 21,840 | Mtr | 309 ₹67.5 L | 324 ₹70.8 L |
| 7.00 | Refilling for Pipe Laying Works Having Bed Width 0.8m and 1.05m Depth for 250mm DI Pipes TWAD SOR WD-W0666 | 21,840 | Mtr | 40 ₹8.7 L | 42 ₹9.2 L |
| 8.00 | Earthwork Excavation & Refilling for Pipe Laying Works Having Bed Width 0.8m and 1.1m Depth for 200mm HDPE Pipes TWAD SOR WD-W0710 | 3,000 | Mtrs | 283 ₹8.5 L | 297 ₹8.9 L |
| 9.00 | Refilling for Pipe Laying Works Having Bed Width 0.8m and 1.1m Depth for 200mm HDPE Pipes TWAD SOR WD-W0710 | 3,000 | Mtrs | 38 ₹1.1 L | 40 ₹1.2 L |
| 10.00 | Excavation for Pipe Laying Works Having Bed Width 0.6m and 1.05m Depth for 160mm HDPE Pipes TWAD SOR WD-W0708 | 1,500 | Mtrs | 203 ₹3.0 L | 213 ₹3.2 L |
Tender Value
₹30.3 Cr
EMD Value
₹30.3 L
Closing Date
19 Nov 2025, 3:00 pmClosed
Commissioner
Municipal Office, Trichy Main Road, Ulundurpet, Kallakurichi District
Improvements of Water Supply System in Ulundurpet Municipality, Kallakurichi District
2025_MAWS_617278_1
803/2022/E1
Open Tender
Water Supply/Equipments/Meter/Drilling/Boring
365 days
Ulundurpet Municipal Limit
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹30.3 L
Ulundurpet Municipal Office
30 Jan 2026
25 Oct 2025
19 Nov 2025
25 Oct 2025
19 Nov 2025
28 Oct 2025
27 Oct 2025
Amount
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum
Earthwork Excavation for Pipe Laying Works Having Bed Width 0.75m and 1.05m Depth for 150mm DI Pipes TWAD SOR WD-W0664
Refilling for Pipe Laying Works Having Bed Width 0.75m and 1.05m Depth for 150mm DI Pipes TWAD SOR WD-W0664
Earthwork Excavationfor Pipe Laying Works Having Bed Width 0.8m and 1.05m Depth for 200mm DI Pipes TWAD SOR WD-W0665
Refilling for Pipe Laying Works Having Bed Width 0.8m and 1.05m Depth for 200mm DI Pipes TWAD SOR WD-W0665
Earthwork Excavation for Pipe Laying Works Having Bed Width 0.8m and 1.05m Depth for 250mm DI Pipes TWAD SOR WD-W0666
Refilling for Pipe Laying Works Having Bed Width 0.8m and 1.05m Depth for 250mm DI Pipes TWAD SOR WD-W0666
Earthwork Excavation & Refilling for Pipe Laying Works Having Bed Width 0.8m and 1.1m Depth for 200mm HDPE Pipes TWAD SOR WD-W0710
Refilling for Pipe Laying Works Having Bed Width 0.8m and 1.1m Depth for 200mm HDPE Pipes TWAD SOR WD-W0710
Excavation for Pipe Laying Works Having Bed Width 0.6m and 1.05m Depth for 160mm HDPE Pipes TWAD SOR WD-W0708
Refilling for Pipe Laying Works Having Bed Width 0.6m and 1.05m Depth for 160mm HDPE Pipes TWAD SOR WD-W0708
Earthwork Excavation for Pipe Laying Works Having Bed Width 0.6m and 1.05m Depth for 110mm HDPE Pipes TWAD SOR WD-W0705
Refilling for Pipe Laying Works Having Bed Width 0.6m and 1.05m Depth for 110mm HDPE Pipes TWAD SOR WD-W0705
Earthwork Excavation for Pipe Laying Works Having Bed Width 0.6m and 1.05m Depth for 90mm HDPE Pipes TWAD SOR WD-W0704
Refilling for Pipe Laying Works Having Bed Width 0.6m and 1.05m Depth for 90mm HDPE Pipes TWAD SOR WD-W0704
Supplying and filling in foundation and basement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Sinking well below water level including all incidental charges using special tools and plants such as air compressor, helmet etc., complete and including baling out water. H. for 4.5m internal dia - First depth of 2 metres TWAD SOR 2024-25 - Vol II WD-W0168
Second depth of 2 metres TWAD SOR 2024-25 - Vol II WD-W0169
Third depth of 2 metres TWAD SOR 2024-25 - Vol II WD-W0170
Fourth depth of 2 metres TWAD SOR 2024-25 - Vol II WD-W0171
Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
Plain Cement Concrete 1:1.5:3 (One part of Cement, one and half part of Crushed Sand (M- Sand), three coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
Porous Concrete CC 1:4 ( One Cement , four hard broken granite jelly of size 20mm) for steining of infiltration well excluding cost of centering but including cost of curing etc complete as directed by engineer
Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. - For foundation & basement
Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. - upto 3.66m above GL
Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. - 3.66m to 7.32m above GL
Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. - 7.32m to 10.98m above GL
Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. - 10.98m to 14.64m above GL
Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. - 14.64 m to 18.30 m above GL
Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. - 18.30 m to 21.96 m above GL
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - for plane surface 0-3.3m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 3.30-4.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 7.30-8.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 11.30-12.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - Curved Surface 0-3.3m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 15.30-16.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 16.30-17.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 17.30-18.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 18.30-19.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - Square Column 0-3.3m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 3.30-4.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 4.30-5.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 5.30-6.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 6.30-7.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 7.30-8.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 8.30-9.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 9.30-10.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 10.30-11.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 11.30-12.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 12.30-13.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 13.30-14.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 14.30-15.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 15.30-16.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 16.30-17.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - Circular Column 0-3.3
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 3.30-4.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 4.30-5.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 5.30-6.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 6.30-7.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 7.30-8.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 8.30-9.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 9.30-10.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 10.30-11.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 11.30-12.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 12.30-13.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 13.30-14.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 - 14.30-15.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38- 15.30-16.30m
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification
Supply & Fixing of CI Steps TWAD SOR VOL II 2024-25 MW-M0237
Supply and delivery of following sizes of FRC Manhole Covers / Frames to stores as per IS 12592:2002 to its latest revision with reinforcement details for covers and frames
Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9" X 43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work
FRP Door Sutter with FRP Door Frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers
Plastering with cement mortar 1:4 (One Part of Cement and Four part of Plastering Sand (P- Sand)) 20mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309)
Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification.
Refilling the sides of foundation with excavated earth (other than sand) in layers of 15cm thick,watered well rammed and consolidated etc. complete complying with standard specification removing and spreading the surplus earth at the placed shown and as directed by the TWAD Board Officers.
Providing and fixing RCC inside access ladder of approved pattern and design in RCC M20 design mix of ISS gauge 0.40m width, 0.10m thickness, 0.12m breadth for side post, 0.05m thickness 0.12m breadth for steps with suitable inclination including cost of cement, reinforcement centering, finishing, curing etc., complete and as directed by TWAD Board Officers.
Supply and fixing of M20 design mix RCC hand rails of 0.9m height over the top of the roof slab of approved pattern and design including the cost of cement, reinforcement, centering, precasting, finishing, curing cement painting the surfaces etc., complete and as directed by the TWAD Board Officers
Supplying and fixing in position of cut stone of size 0.45m x 0.45m x 0.15m set in CM 1:3(One part cement and three part sand) at bottom of inlet pipe inside the Sump the suitable size and as directed by the TWAD Board Officers.
Supply and fixing in position ventilator of reinforcement cement concrete RCC M20 design mix 50 CM wide/diametre of approved pattern and design including cost of cement, reinforcement centering, shuttering, strutting, curing and fixing in position on the roof slab with mosquito proof net arrangement etc., complete. and as directed by the TWAD Board Officers.
Labour charges for painting TWAD Board Emblem in accordance with the size and specifications as approved by the Board on the Service Reservoirs including cost of all consumables etc., complete and as directed by TWAD Board Officers. - Spiral Staircase
SUPPLY OF DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K7 - DI - K7 Pipe 250mm PWD SOR VOL II WD-M0623
SUPPLY OF DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K7 - DI - K7 Pipe 200mm PWD SOR VOL II WD-M0622
SUPPLY OF DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K7 - DI - K7 Pipe 150mm PWD SOR VOL II WD-M0621
Lowering of C.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers. - 250mm Dia PWD SOR- VOL II WD-W0249
Lowering of C.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers. - 200mm Dia PWD SOR- VOL II WD-W0248
Lowering of C.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers. - 150mm Dia PWD SOR- VOL II WD-W0247
Supply and delivery of DI D/F Gate (sluice) valves (soft seated) resilient seated soft sealing Gate Valves (Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or GGG 50, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be ompatible for buried application with pressure rating PN 10/16 and with 5 years warranty- 250mm PWD SOR 2024-25 VOL II WD-M1202
Testing of pipes for water supply with hydraulic testing uipment by filling with water (including cost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, luding the cost of pipes but including other incidential and operational charges etc., complete for the following Diametres of pipes. - 250mm Dia PWD SOR- VOL II WD-W0464
Testing of pipes for water supply with hydraulic testing uipment by filling with water (including cost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, luding the cost of pipes but including other incidential and operational charges etc., complete for the following Diametres of pipes. - 2000mm Dia PWD SOR- VOL II WD-W00463
Testing of pipes for water supply with hydraulic testing uipment by filling with water (including cost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, luding the cost of pipes but including other incidential and operational charges etc., complete for the following Diametres of pipes. - 150mm Dia PWD SOR- VOL II WD-W00462
Jointing the C.I/ D.I - S/S pipes and specials with molten lead and Yarn including caulking the joints. (Including cost of jointing materials) - 250mm Dia
Jointing the C.I/ D.I - S/S pipes and specials with molten lead and Yarn including caulking the joints. (Including cost of jointing materials) - 200mm Dia
Jointing the C.I/ D.I - S/S pipes and specials with molten lead and Yarn including caulking the joints. (Including cost of jointing materials) - 150mm Dia
Cutting C.I./D.I Pipes true to axis and filing smoothly and finishing the ends complete. - 250mm Dia
Cutting C.I./D.I Pipes true to axis and filing smoothly and finishing the ends complete. - 200mm Dia
Cutting C.I./D.I Pipes true to axis and filing smoothly and finishing the ends complete. - 150mm Dia
Supply of HDPE Pipes - PE 100 as per IS 4984/2016 - 200 Dia Pipe
Supply of HDPE Pipes - PE 100 as per IS 4984/2016 - 160 Dia Pipe
Supply of HDPE Pipes - PE 100 as per IS 4984/2016 - 110 Dia pipe
Supply of HDPE Pipes - PE 100 as per IS 4984/2016 - 90 Dia pipe
Lowering HDPE pipes and specials to trench and laying to proper grade and alignment and as directed by the TWAD Officers - 200 Dia Pipe
Lowering HDPE pipes and specials to trench and laying to proper grade and alignment and as directed by the TWAD Officers - 160 Dia Pipe
Lowering HDPE pipes and specials to trench and laying to proper grade and alignment and as directed by the TWAD Officers - 110 Dia pipe
Lowering HDPE pipes and specials to trench and laying to proper grade and alignment and as directed by the TWAD Officers - 90 Dia pipe
Testing of pipes for water supply with hydraulic testing uipment by filling with water (including cost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, luding the cost of pipes but including other incidential and operational charges etc., complete for the following Diametres of pipes. - 160 Dia Pipe
Testing of pipes for water supply with hydraulic testing uipment by filling with water (including cost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, luding the cost of pipes but including other incidential and operational charges etc., complete for the following Diametres of pipes. - 110 Dia pipe
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307- 2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers. - 90mm
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307- 2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers. - 110mm
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307- 2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers. - 160mm
Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307- 2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers. - 200mm
Cutting P.V.C./ HDPE rigid pipes and specials true to axis and finishing the ends complete - 90mm
Cutting P.V.C./ HDPE rigid pipes and specials true to axis and finishing the ends complete - 110mm
Cutting P.V.C./ HDPE rigid pipes and specials true to axis and finishing the ends complete - 160mm
Cutting P.V.C./ HDPE rigid pipes and specials true to axis and finishing the ends complete - 200mm
DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K7 250mm Dia PWD SOR 2024-25 Vol II WD-M0623
Supply and delivery of DI D/F Gate (sluice) valves (soft seated) resilient seated soft sealing Gate Valves (Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or GGG 50, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16 and with 5 years warranty PWD SOR 2024-25 Vol II WD-M1202 200mm PWD SOR 2024-25 VOL II WD M1201
Supply and delivery of DI D/F Gate (sluice) valves (soft seated) resilient seated soft sealing Gate Valves (Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or GGG 50, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16 and with 5 years warranty PWD SOR 2024-25 Vol II WD-M1202 - 150mm PWD SOR 2024-25 VOL II WD M1200
Supply and delivery of DI D/F Gate (sluice) valves (soft seated) resilient seated soft sealing Gate Valves (Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or GGG 50, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16 and with 5 years warranty PWD SOR 2024-25 Vol II WD-M1202 - 100mm PWD SOR 2024-25 VOL II WD M1199
Supply and delivery of DI D/F Gate (sluice) valves (soft seated) resilient seated soft sealing Gate Valves (Sluice Valves) with body Bonnet of Ductile cast iron of Grade GGG 40 or GGG 50, Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 O- Ring protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 14846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application with pressure rating PN 10/16 and with 5 years warranty PWD SOR 2024-25 Vol II WD-M1202 - 250 mm PWD SOR 2024-25 VOL II WD M1202
Manufacture, Supply and Delivery of Tamper proof DI single chamber double orifice triple function (ventilating, admiting & ventilating during operation) air release valve with pressure rating PN 10/16 with body and cover made of Ductile Iron of Grade GGG 40 or GGG 50, nforming to IS 1865 with Food Grade Epoxy Powder coating (EP-P) inside and for outside of colour blue RAL 5005. All internal parts such as float, shell etc., cover bolts, made of Austenitic alloy steel of SS AISI 304/316. The float shall be made of Polytetrafluroethylene/ ustenitic alloy steel of AISI 304/316. Gaskets and seals of EPDM / Neoprene rubber for TWAD Board works anywhere in Tamil Nadu and with 5 years warranty PWD SOR 2024-25 VOL II WD-M1196
FIXING SLUICE VALVE IN MASONARY PIT (As per Type Design)
Cables & Cable Galands - Supply and clarnping of 4 x 6 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps SD 197
Supply and clarnping of 3-1/2 X 35 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps SD 201
Supply and clarnping of 3-1/2 X 300 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps SD 208
Supply and clarnping of 4 X 10 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps SD 198
Supply and clarnping of 4 X 16 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps SD 199
Supply and clarnping of 4 X 25 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps SD 200
Supply and fixing of brass cable gland for 4 x 25 sq.mm. LTUG armoured cable with earth connection SD 163
Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection SD 165
Supply and frxing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection SD 160
Supply and fixing of brass cable gland for 3-1/2 x 300 sq.mm. PVC armoured LTUG cable with earth connection SD173
Earthing as per PWD standard with an earth electrode of 2metre Class'B' Gipipe of dia not less than 32 mm complete with necessary masonry work SD 212
Supply and run of 25mmx6mm tinned copper flat with necessary clamps /supports on wall/ floor /ground for earth connection SD 77
Supply and fixng of TNEB meter board suitable for 3 phase 200A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 200A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete SD 134
Supply and fixing of 4 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board ( with MCCB Incomer ) with double door (metal door ) with 1 no. 160 A 4 P MCCB switch as incoming and 2 nos. 63A 3P MCB , 6 nos. 6A to 32A SP MCB as outgoing with suitable cable end box on wall with earth connection only. Higher End SD 600
Supply and fixing of 8 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board ( with MCCB Incomer ) with double door (metal door) with 1 no. 160 A 4 P MCCB switch as incoming and 6 nos. 63A 3P MCB , 6 nos. 6A to 32A SP MCB as outgoing with suitable cable end box on wall with earth connection only. Higher End SD 612
Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The nonreturn valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. 600 LPM X 25m Head PWD SOR VOL II WD-1778
Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The nonreturn valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. 1500 LPM X 80m Head PWD SOR VOL II WD-1804
Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The nonreturn valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation. 1000 LPM X 40m Head PWD SOR VOL II WD-1794
4’ 18W Crystal Glass LED Tube Light Fitting PWD SOR VOL I 2024-25 M-1211
80W LED Focus Light Fitting with LED PWD SOR VOL I 2024-25 M-1292
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 WD-W0873
Drilling of borewells of size 6” to 8” dia. in sedimentary formation using hand boresets including insertion of casing pipes and removal of casing pipes etc., including collection of samples as directed by the TWAD Board Officers..
Supply of the following UPVC Pipe 6 KSc Pipe as per IS specifications 4985/2000.160 MM PIPE
Supply and delivery of bolts and nuts 20mm dia and above x 90mm etc.,
Drilling of 140/150 mm pilot bore - Upto 60 m Depth ending below ground level
Drilling of 140/150 mm pilot bore - From 60 m upto 90 m Depth ending from ground level
Drilling of 140/150 mm pilot bore - From 90 m upto 120 m Depth ending from ground level
Drilling of 140/150 mm pilot bore - From 120 m upto 150 m Depth ending from ground level
Drilling of 140/150 mm pilot bore - From 150 m upto 180 m Depth ending from ground level
Drilling of 140/150 mm pilot bore - From 180 m upto 210 m Depth ending from ground level
Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. - Upto 60 m Depth ending below ground level
Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. - From 60 m upto 90 m Depth ending from ground level
Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. - From 90 m upto 120 m Depth ending from ground level
Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. - From 120 m upto 150 m Depth ending from ground level
Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. - From 150 m upto 180 m Depth ending from ground level
Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. - From 180 m upto 210 m Depth ending from ground level
PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the executive engineers of TWAD Board 200mm Dia ( Casing Pipe ) TWAD SOR 2024-25 - Vol II - WD-M0030
PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the executive engineers of TWAD Board 200mm Dia ( Casing Pipe ) Ribbed PIpes TWAD SOR 2024-25 - Vol II - WD-M0031
Labour Charges for inserting PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the executive engineers of TWAD Board 200mm Dia ( Casing Pipe ) PWD SOR 2024-25 - Vol II - WD-WD-M0026
Supplying and fixing of suitable PVC endcap (6kg/cm2) for 200 dia borewell of best quality with ISI mark PWD SOR 2024-25 - Vol II - WD-W0831
Supplying and fixing of suitable Nylon Rope for Bore-well of best quality with ISI mark PWD SOR 2024-25 - Vol I - M-1072
Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % 200LPMX125 Head PWD SOR 2024-25 - Vol II - WD-M1675
Supplying and erection of Submersible wire 3x6 sqmm cable PVC insulated and sheathed 3core flat type copper cable with ISI make including erection inside the bore well and open run of clamping etc., completer complying with standard specification., as directed by the departmental offcers., PWD SOR 2024-25 - Vol 1 - WD M-1976
Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor as directed by TWAD Officers and conducting yield test by ‘V’ notch method
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.
Goods and Service Tax @ 18%
VOLGA POWER INDIA PRIVATE LIMITED (BID ID -1509469)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
BidWS.pdf
Tender Documents • 0.77 MB
BOQ_737678.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid