| 1 | L1₹26.6 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹28.2 L+₹94,591 (3.47%)Rejected-Finance | L2 | Rejected-Finance Rejected being higher than L1 | |
| 3 | L3₹28.7 L+₹1.4 L (5.24%)Rejected-Finance | L3 | Rejected-Finance Rejected being higher than L1 | |
| 4 | L4₹28.9 L+₹1.7 L (6.12%)Rejected-Finance 5 KHANAURI MANDI TEHSIL MOONAK MOONAK SANGRUR PUNJAB 148027 | SANGRUR | PUNJAB | 148027 | L4 | Rejected-Finance Rejected being higher than L1 | |
| 5 | L5₹29.3 L+₹2.1 L (7.70%)Rejected-Finance 72 5 53 PIPE ROAD PO BARRACKPORE DIST 24 PARGANAS NORTH PIN 700120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L5 | Rejected-Finance Rejected being higher than L1 |
| Sl No | Description | Qty | Unit | KUMAR ENTERPRISE L6 | SARKAR AND COM L1 | PIONEER L5 | JAGATRAM CONSTRUCTION L3 | BISWAS CONSTRUCTION L2 | P.J. AND CO. L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down ceiling fan of 1200mm sweep/exhaust fan 300/380mm sweep / wall mounted fan of 300/400mm sweep by unscrewing nut/bolts from its position for painting/overhauling/rewinding etc and fixing the same to its original position after necessary cleaning, oiling, greasing complete all as specified and directed. | 1,270 | Each | 200 ₹2,54,000 | 195 ₹2,47,650 Lowest | 202 ₹2,56,540 | 199.55 ₹2,53,428.5 | 201 ₹2,55,270 | 201 ₹2,55,270 |
| 2.00 | All as per Item No.1.00 here-in-before but ceiling fan of 1400 mm sweep/exhaust fan of 400/450mm / pedestal fan 450/600mm sweep / Air circulator fan upto 600mm sweep and -ditto-. | 317 | Each | 215 ₹68,155 | 210 ₹66,570 Lowest | 217 ₹68,789 | 217 ₹68,789 | 217 ₹68,789 | 215 ₹68,155 |
| 3.00 | Material and labour for painting to ceiling fan of 1200mm sweep by scraping/removing old paint with brush/emery paper and spray painting with two coat of synthetic enamel paint including marking of MES number complete all as specified and directed. Note :- Taking down and refixing of ceiling fan shall be measured and paid against item no 1.00 above. | 550 | Each | 240 ₹1,32,000 | 195 ₹1,07,250 Lowest | 241 ₹1,32,550 | 242 ₹1,33,100 | 239 ₹1,31,450 | 242 ₹1,33,100 |
| 4.00 | Material and labour for painting to ceiling fan of 1400 mm sweep by scraping/removing old paint with brush/emery paper and spray painting with two coats of synthetic enamel paint including marking of MES number complete all as specified and directed.
Note :- Taking down and refixing of ceiling fan shall be measured and paid against item no 2.00 above. | 100 | Each | 252 ₹25,200 | 230 ₹23,000 Lowest | 251 ₹25,100 | 254 ₹25,400 | 257 ₹25,700 | 251 ₹25,100 |
| 5.00 | Material and labour for painting of exhaust fan/ pedestal fan/wall mounted fan of any sweep by scraping/removing old paint with brush/emery paper and spray painting with two coat of synthetic enamel paint including marking of MES number complete all as specified and directed.
Note :- Taking down and refixing of exhaust fan/pedestal fan/wall mounted fan shall be measured and paid against item no 1.00 & 2.00 above. | 120 | Each | 258 ₹30,960 | 180 ₹21,600 Lowest | 255 ₹30,600 | 265 ₹31,800 | 260 ₹31,200 | 256 ₹30,720 |
| 6.00 | Dismantling of complete ceiling fan of size 1200mm sweep down rod with its canopies, shackle, capacitor housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :-
Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete including fixing only old/new spare parts rubber bush of shackle and capacitor housing, capacitor, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed.
Note :- Ball bearing capacitor and Gun metal bush shall be measured as supply only and paid separately under respective items and fixing charges for spare parts shall deemed to be included in the quoted rate. | 480 | Each Job | 1,100 ₹5,28,000 | 1,010 ₹4,84,800 | 1,000 ₹4,80,000 | 825 ₹3,96,000 Lowest | 826 ₹3,96,480 | 949 ₹4,55,520 |
| 7.00 | All as per Item No.6.00 here-in-before but ceiling fan of 1400 mm sweep celling fan and -ditto-. | 100 | Each Job | 1,150 ₹1,15,000 | 1,020 ₹1,02,000 | 900 ₹90,000 | 896 ₹89,600 Lowest | 902 ₹90,200 | 898 ₹89,800 |
| 8.00 | All as per Item No. 6.00 here-in-before but exhaust fan of 300/380 mm sweep exhaust fan and -ditto-. | 120 | Each Job | 1,000 ₹1,20,000 | 910 ₹1,09,200 Lowest | 1,050 ₹1,26,000 | 1,010 ₹1,21,200 | 1,020 ₹1,22,400 | 1,001 ₹1,20,120 |
| 9.00 | All as per Item No. 6.00 here-in-before but exhaust fan of 400/450 mm sweep exhaust fan and -ditto-. | 45 | Each Job | 1,050 ₹47,250 | 925 ₹41,625 Lowest | 1,025 ₹46,125 | 1,105 ₹49,725 | 1,090 ₹49,050 | 1,052 ₹47,340 |
| 10.00 | All as per Item No. 6.00 here-in-before but pedestal fan/air circulator any sweep and -ditto-. | 22 | Each Job | 1,075 ₹23,650 | 890 ₹19,580 Lowest | 1,076 ₹23,672 | 1,128 ₹24,816 | 1,158 ₹25,476 | 1,076 ₹23,672 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
28 Jul 2025, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIR / MAINT OF CEILING FAN, EXHAUST FAN, WALL FANS, PEDESTAL FANS, AIR CIRCULATOR FAN, REPLACEMENT OF FLAME PROOF EXHAUST FAN, FLAME PROOF LIGHT FITTING WITH CONNECTED FLAME PROOF SWITCHES UNDER 6 WING UNDER GE (AF) BARRACKPORE.
2025_MES_716628_1
8631/BKP/AF OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE AF Barrackpore
Class-E,
Category-b(i)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹50,000
Yes
7 Aug 2025
25 Jun 2025
30 Jul 2025
25 Jun 2025
28 Jul 2025
9 Jul 2025
Amount
Taking down ceiling fan of 1200mm sweep/exhaust fan 300/380mm sweep / wall mounted fan of 300/400mm sweep by unscrewing nut/bolts from its position for painting/overhauling/rewinding etc and fixing the same to its original position after necessary cleaning, oiling, greasing complete all as specified and directed.
All as per Item No.1.00 here-in-before but ceiling fan of 1400 mm sweep/exhaust fan of 400/450mm / pedestal fan 450/600mm sweep / Air circulator fan upto 600mm sweep and -ditto-.
Material and labour for painting to ceiling fan of 1200mm sweep by scraping/removing old paint with brush/emery paper and spray painting with two coat of synthetic enamel paint including marking of MES number complete all as specified and directed. Note :- Taking down and refixing of ceiling fan shall be measured and paid against item no 1.00 above.
Material and labour for painting to ceiling fan of 1400 mm sweep by scraping/removing old paint with brush/emery paper and spray painting with two coats of synthetic enamel paint including marking of MES number complete all as specified and directed. Note :- Taking down and refixing of ceiling fan shall be measured and paid against item no 2.00 above.
Material and labour for painting of exhaust fan/ pedestal fan/wall mounted fan of any sweep by scraping/removing old paint with brush/emery paper and spray painting with two coat of synthetic enamel paint including marking of MES number complete all as specified and directed. Note :- Taking down and refixing of exhaust fan/pedestal fan/wall mounted fan shall be measured and paid against item no 1.00 & 2.00 above.
Dismantling of complete ceiling fan of size 1200mm sweep down rod with its canopies, shackle, capacitor housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :- Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete including fixing only old/new spare parts rubber bush of shackle and capacitor housing, capacitor, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed. Note :- Ball bearing capacitor and Gun metal bush shall be measured as supply only and paid separately under respective items and fixing charges for spare parts shall deemed to be included in the quoted rate.
All as per Item No.6.00 here-in-before but ceiling fan of 1400 mm sweep celling fan and -ditto-.
All as per Item No. 6.00 here-in-before but exhaust fan of 300/380 mm sweep exhaust fan and -ditto-.
All as per Item No. 6.00 here-in-before but exhaust fan of 400/450 mm sweep exhaust fan and -ditto-.
All as per Item No. 6.00 here-in-before but pedestal fan/air circulator any sweep and -ditto-.
Repairs to ceiling fan (old model) of size 1200/1400mm sweep down rod with its canopies, shackle, capacitor housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :- Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete ceiling fan including fixing only old/new spare parts (i.e.) rubber bush of shackle and capacitor housing, capacitor, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed. Note :- (i) Necessary lath machine work for Gun metal bush housing replace with ball bearing housing. (ii) Ball bearing capacitor and Gun metal bush shall be measured as supply only and paid separately and fixing charges for spare parts shall deemed to be included in the quoted rate .
Supply only 2.5 MFD capacitor .
Supply only 3.5/4 MFD capacitor .
Supply only rubber bush for shakle with bolt ,nut and lock pin suitable for ceiling fan 1200 / 1400 mm sweep.
Supply only PVC holder for capacitor housing.
Supply only ball bearing No- 6202 as required. Make:- SKF/NBC/TATA
Supply only ball bearing No- 6203 as required. Make:- SKF/NBC/TATA
Supply only ball bearing No- 6201 as required. Make:- SKF/NBC/TATA
Supply only ball bearing No- 6204 as required. Make:- SKF/NBC/TATA
Supply only ceiling fan spindle of existing size.
Supply only gun metal bush as required
Supply and fix in repair PCB assembly with insulation paper for Energos 35 1200 mm, maximum power upto 48 Watt, voltage 12-24 VDC of BLDC ceiling fan (Make- Bajaj) complete all as specified and directed.
Supply and fix in repair stator ENERGOS 35 1200mm CF, maximum power upto 48 Watt, voltage 12-24VDC of BLDC ceiling fan (Make- Bajaj) complete all as specified and directed.
Supply and fix in repair Remote ENERGOS 35 1200mm CF of BLDC ceiling fan (Make- Bajaj) complete all as specified and directed.
Supply fix in repair Sensor ENERGOS 35 1200mm CF of BLDC ceiling fan (Make- Bajaj) complete all as specified and directed.
Supply fix in repair rotor (Magnet Yoke) 14 mm ENERGOS 35 1200mm CF of BLDC ceiling fan (Make- Bajaj) complete all as specified and directed.
Supply and fix in repair fan Blade assembly ENERGOS 35 1200mm white of BLDC ceiling fan (Make- Bajaj) complete all as specified and directed.
Supply and fix in repair delux steped type electronic fan regulator flush type complete all as specified and directed.
Supply and fix in repair modular fan regulator ,step type ,120 Watt, 2-module complete all as specified and directed.
Supply and fix in repair PVC blades of 300 mm sweep for wall / air circulator / stand fan complete all as specified and directed.
Supply and fix in repair PVC blades of 350/380 mm sweep for wall/air circulator/stand fan complete all as specified and directed.
Supply and fix in repair wall mounted air circulator fan metal body, 230V, 50Hz, oscillatiing 450mm sweep, heavy-duty motor with double ball bearing, 1440 RPM, air delivery 7500 cum per hour complete all as specified and directed. Make : Crompton Greaves /HAVELLS/ ORIENT/ USHA.
Supply and fix in repair louvers with shutters made of GI sheet suitable for 300/380/450 mm sweep exhaust fan complete all as specified and directed.
Supply and fix in repair fan blade (metal body) suitable for 300/380/450 mm sweep exhaust fan complete all as specified and directed.
Supply and fix in repair fan blade (metal body)suitable for 1200 mm sweep ceiling fan complete all as specified and directed.
Supply and fix in repair fan blade (metal body)suitable for 1400 mm sweep ceiling fan complete all as specified and directed.
Material and labour for light/fan point wiring controlled by one switch (surface type) with single core PVC insulated unsheathed multistranded FR-LSH copper conductor cable of 1100 volts grade size 1.5 sqmm (nominal area) in and including PVC casing capping of suitable size with 1.2mm thick pressed steel terminal boxes in recess to existing wall surface with 3mm thick bakelite sheet top cover (ISI marked) fixed with chromium plated brass screws and cap washers suitable for housing switches, sockets and regulators with all fittings and fixing materials with one single core PVC insulated unsheathed 1.5 sqmm (nominal area) stranded FR-LSH copper conductor as earth continuity wire and connected to earth dolly and including taking down old unserviciable existing point wiring with all fixtures such as switches, sockets etc.complete all as specified and directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
Supply and fix of switch piano one way 5/6 amps 240 volts, single pole complete all as specified and as directed.
Supply and fix ceiling rose, 3 terminals, fabricated of PVC/Polycarbonate, isolated body complete all as specified and directed.
Supply and fix in repair 50x6mm thickness MS strip clamp with nut, bolt and washers suitable for fixing of ceiling fan complete all as specified and directed.
Supply and fix in repair 300mm sweep steel body exhaust fan AC single phase 230/240 volt. 1400 RPM, heavy duty, ISI marked, along with metal blade powder coated metalic finish with louvers, low noise including necessary electric connection complete all as specified and as directed. Make : Crompton Greaves /HAVELLS/ ORIENT/ USHA
Taking down the rusted down rod of ceiling fan of 300mm long and supply and fix new down rod including painting two coats of synthetic enamel paint complete all as specified and directed.
Taking down the rusted down rod of ceiling fan of 600mm long and supply and fix new down rod including painting two coats of synthetic enamel paint complete all as specified and directed.
Supply and fix canopy suitable for 1200/1400 mm sweep ceiling fan of existing type & size complete all as specified and directed.
Supply and fix in repair PVC insulated single core 1.5 sqmm 3 core, multi strand FR-LSH copper conductor for the connection of ceiling fan from ceiling rose complete all as specefied and directed.
Material and labour for making hole suitable for exhaust fan of 380/450/600 mm sweep and making good distributed surfaces complete all as specefied and directed.
Material and labour for making hole to the existing brick wall for inserting 40mm G.I pipe including making good to the distributed wall complete all as specified and directed.
Material and labour for galvanised steel tubing of dia 40mm medium grade for hanging of fan with clamp / hook including taking down old unserviceable existing GI tube complete all as specified and directed.
Material and labour for flame proof light / fan point wiring (concealed type) with single core PVC insulated unsheathed multistranded FRLSH copper conductor cable of 1100 volts grade size 1.5 sqmm (nominal area) in and including 20mm dia heavy duty rigid steel conduit with accessories including 1.2mm thick pressed steel terminal boxes in recess to existing wall surface with 3mm thick bakelite sheet top cover (ISI marked) fixed with chromium plated brass screws and cap washers suitable for housing switches, sockets and regulators with all fittings and fixing materials with one single core PVC insulated unsheathed multistranded FRLSH 1.5 sqmm (nominal area) copper conductor as earth continuity wire and connected to earth dolly including taking down old unserviceable complete all as specified and directed. Note: (a) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for Each individual circuit from the distribution board. (b) Quoted rate shall be included for cuttings /chasing the wall and making good disturbed surfaces to fix steel conduit and MS terminal box.
All as per item No. 49.00 here-in-before but for 15 amps socket outlet on independent board with 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade including 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade as earth continuity conductor and connecting to common earth dolly and -ditto-.
Supply and fix in repair flameproof switch LM6 body, rotary switch, SP, 16 Amps , IP66 protection die cast aluminium alloy for ON/OFF light / fan point to operate on single phase 230 Volts, AC with termination box certified by CIMFR and PESO certified IS-2145 complete all as specified and directed. Make : Sudhir /Bajaj/ Crompton Greaves.
Supply and fix in repair flame proof flexible metalic hose conduit 20mm dia 300mm long for exhaust fan/ flame proof light fitting connection from ceiling rose complete all as specified and directed. Make : Sudhir /Bajaj/ Crompton Greaves.
Supply and fix in repair flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth 230 Volts, AC with termination box certified by CIMFR and PESO certified IS-2145 complete all as specified and directed. Make : Sudhir /Bajaj/ Crompton Greaves.
Supply and fix in repair flame proof / weather proof LED 2 x 20W 4 feet 230 V tube light fitting with lumen output not less than 4000 Lumens, body made out of cast aluminium alloy LM6 construction certified by CIMFR, BIS & PESO including suitable electronic including necessary fixing arrangements and connecting up complete all as specified and directed. Make: Sudhir /Bajaj/ Crompton Greaves.
Supply and fix in repair flame proof / weather proof LED 1 x 20W 4 feet 230 V tube light fitting with lumen output not less than 4000 Lumens, body made out of cast aluminium alloy LM6 construction certified by CIMFR, BIS & PESO including suitable electronic including necessary fixing arrangements and connecting up complete all as specified and directed. Make: Sudhir /Bajaj/ Crompton Greaves.
Supply and fix in repair flame proof exhaust fan having sweep size of 300 mm having air discharge capacity of 1120 CFM complete with 0.25HP single phase 240V, 1440RPM capacity of motor duly approved and fixed with nut, bolt, washer and making good distrubed surfaces complete all as specified and as directed. Make : Sudhir /Bajaj/ Crompton Greaves.
BISWAS CONSTRUCTION (BID ID -3360246)
JAGATRAM CONSTRUCTION (BID ID -3360424)
P.J. AND CO. (BID ID -3360093)
PIONEER (BID ID -3360272)
KUMAR ENTERPRISE (BID ID -3372729)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .