| 1 | L1₹19.8 LAccepted-AOC MISSAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹20.5 L+₹47,247.40 (2.35%)Rejected-Finance LAKHPURA BUTCHERY MISSAMARI DIST SONITPUR ASSAM PIN 784506 | MISSAMARI | SONITPUR | ASSAM | 784506 | L2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹25.3 L
EMD Value
₹51,000
Closing Date
29 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MISAMARI
PO-Missamari Dist-Sonitpur Assam
SPL REPAIR TO SEWAGE LINE IN SATA REGT AND OTHER SANCTIONED WORKS UNDER GE MISAMARI
2020_MES_393968_2
8148
Open Tender
Civil Works
Item Rate
180 days
GE MISAMARI
PLEASE REFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
Yes
GE MISAMARI
₹51,000
Yes
19 Jan 2021
7 Dec 2020
31 Dec 2020
7 Dec 2020
29 Dec 2020
17 Dec 2020
7 Dec 2020 - 12 Dec 2020
60 days
Amount
Demolition Cement Concrete (un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed. (Note:Demolished material to be used for filling under floors to bring upto required level, if neccesary)
Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for,complete all as specified and as directed.
Demolition Brick Work or Stone/ Bolder masonary built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any description, complete all as specified and as directed. Note:Demolished material to be used for filling under floors to bring upto required level.
Demolition and breaking up 200mm drain pipes ( Salt glazed ware, AC or reinforced concrete) set in cement mortar complete and disposed off from the premises all as directed.
Demolition and breaking up 300mm drain pipes ( Salt glazed ware, AC or reinforced concrete) set in cement mortar complete and disposed off from the premises all as directed.
Dismantling Wrought Iron or Mild Steel Work, viz. MS Flat Iron (Wind Tie) and Similar Work including MS Bolts, Nuts, etc., and keep in Safe Custody for re-use, complete all as specified and as directed.
Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water remove Dust, debries/ rubbish etc., complete all as specified and as directed.
Taking up or down Steel Tubing 15mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
Taking up or down Steel Tubing 20mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
Taking down Chowkat or Frame (without taking off Shutter from the Frame) not exc. 1.50 Square Metre Each,,complete all as specified and as directed.
Taking down Chowkat or Frame (without taking off Shutter from the Frame) exc. 1.50 Square Metre but not exc. 4.00 Square Metre Each, complete all as specified and as directed.
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), removing from the Sites and rubbish off the Premises, complete all as specified and as directed.
Dismantling water tanks of size exc 250 & not exc 500ltrs capacity on roof/staging, complete all as specified and directed.
M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290.Gde-E-165 complete all as specified and directed.
M&L Reinforced Cement Concrete (nominal mix) 1:1.5:3,type A1 (20mm graded stone aggregate) in Chajjas complete all as specified and as directed. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Items.
M&L Pre-cast Reinforced Cement Concrete (nominal mix) 1:2:4 type B1(20mm graded stone aggregate) in Slab Supported on wall, Cover Slabs for Manholes, Shelves and Similar Articles, etc., Set in Cement Mortar 1:4 including use and waste of Formwork as required/ordered at Site(s) and including demolition of existing old RCC slabs of any description , complete all as specified and as directed. NOTE : Reinforcement will be measured and paid separately under relevant Item.
M&L Formwork to Sides and Soffits of Chajjas, Overhangs, etc., rough finished surfaces of Concrete, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:4, complete all as specified and as directed.
M&L brick work with sub-class ‘B’ Bricks Straight or Curved on Plan exc.any radius in half brick thick built in Cement Mortar 1:4, complete all as specified and as directed.
S&F Factory made Solid Panel PVC Door Shutter 30mm thick (Style) consisting of Frame made out of Mild Steel Square Tube for Top and Bottom Rails, mild steel Frame shall be covered with heat moulded plain colour PVC 'C' Channel having PVC Sheet Strip 20 mm wide stuck inside with Solvent Cement for Styles and plain colour PVC Sheet for Top Rail, Lock Rail & Bottom Rail on either side and as gap insert for Top Rail, Bottom Rail Panelling of plain colour PVC Sheet to be fitted in mild steel Frame welded/sealed to the Styles and Rails with suitable Sheet Beading and jointed together with Solvent Cement and fixing in the Frame at Site as per Specification and Drawing of MES Schedule Part-II, complete all as specified and as directed.
S&F Factory made Solid PVC Door Frame of size 50x47 mm made out of 5.0 mm thick plain colour PVC Sheet reinforced with Mild Steel Square Tube and fixing in opening as per Specification and Drawing of MES Schedule Part-II, complete all as specified and as directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., conforming to Fe 290-W (Gde E-165) quality A, drilled for fixing of steel sheeting or other covering Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening,complete all as specified and as directed.
M&L Second Class Hardwood 35mm thick Glazed and Skelton Shutters, open rebated and prepared to receive Glass, Gauze, etc. (without Sash Bars) edges of Framing plain, chamfered or rounded, mitred beads for screwing Glass, Gauge, etc. sizes of members of Shutter as speci fied in MES Schedule Part-I Section 8, Clause No. 8.24(a) and fitted to Wooden Chowkat, complete all as specified and as directed.
M&L Flush Door Shutter 30mm thick, Solid Core Construction with Block Board Core and Plywood face Panels commercial type on both side with Particle Board and fitted to Wooden Chowkat, complete all as specified and as directed.
S&F Aluminium anodised Barrel Tower Bolt 150 mm long, Extruded Section and fixed, complete all as specified and as directed.
S&F Mild Steel Butt Hinge of size 100mm, medium weight, cold rolled and fixed, complete all as specified and as directed
All as per Item no.27 here in before but for 75 mm, complete all as specified and directed.
S&F Aluminium Handle 125mm long Cast type, complete all as specified and as directed.
S&F Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples and fixed, complete all as specified and as directed.
S&F Double Action Floor Spring Hydraulically Regulated made up of minimum 1.25mm thick aluminium alloy Sheet Foundation Box, main body with Stainless Steel Cover, Governing Pivot made of Brass, other Parts made of Mild Steel heavy duty and fixed, complete all as specified and as directed.
M&L TMT Bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia, complete all as specified and as directed.
All as per Item no.32 here in before but for 6mm to 8mm, complete all as specified and directed.
M&L Powder coating (minimum thickness of powder coating 50 micron) Aluminium Frame for Doors, Windows, Ventilators with one or more rebates including Jointing Cleat for fixing, etc., complete all as specified and as directed
S & F Powder coated aluminium window shutters and ventilator shutter, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, handles, screws etc. complete all as specified and as directed. NOTE:- (i) Fixing of shutter with fitting shall be as per manufacturers instruction (ii) Rate quoted is deemed to be inclusive of aluminum hardwires as indicated, glazing clips, rubber packing, anodized aluminum snap on beading for fixing glass panes in frame, handles, Locking Arrangement but Glass panes in frame shall be measured and paid separately under respective Sch A items separately at Supply only rates)
S&F Powder coated aluminium door shutters (Single/double shutter), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing anodised aluminum snap beading handles in each door, hinges, handles 2 nos. in each door, anodised snap beading screws, hold fast complete all as specified and as directed and as shown on drawings. NOTE:- (i) Fixing of shutter with fitting shall be as per manufacturers instruction (ii) Rate quoted is deemed to be inclusive of aluminum hardwares as indicated, glazing clips, rubber packing, anodized aluminum snap on beading for fixing glass panes in frame , handles,Locking Arrangement but Glass panes in frame shall be measured and paid separately under respective Sch A items separately at Supply only rates)
M&L Sheet Glass, Ordinary, 5.5mm thick, Glazing in Wooden/Metal Frames and glazed with Beads or Oil Putty, area exc. 0.50 SQM in Each Pane, complete all as specified and as directed.
M&L Cement Concrete 1:3:6, C2 (40mm graded aggregate), 75mm thick as in Plinth Protection, etc., finishing Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L Rendering 15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L Rendering 15mm thick in Cement Mortar 1:4 on Brick Walls or on Concrete Surfaces, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L Rendering 5mm thick in Cement Mortar 1:3 on Brick Walls or on Concrete Surfaces mixed with water proofing compound, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L Rendering 5mm thick in Cement Mortar 1:3 on Brick work or on Concrete Surfaces in ceiling, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L glazed ceramic coloured tiles, glossy finished of size 350x450x7mm/ 350x250x7mm thick as in vertical surfaces such as skirting/dados and riser of stems., over and including including 10 mm thick rendering/backing coat in CM 1:4 and set and jointed in neat cement slurry and pointed in white or colored cement to match the surface of tiles,complete all as specified and as directed.
M & L Screed Bed or Bedding Layer 15mm thick in Cement Mortar 1:6 for laying Floor Finishes/Tiles, complete all as specified and as directed.
M&L Non-Skid Ceramic Coloured Joint free Tiles 7mm to 8mm thick, area of each Tile exc. 0.18 Sqm but not exc. 0.18 Sqm, in Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Tile, complete all as specified and as directed. NOTE : Screed Bed will be measured and paid separately under appropriate Item.
Materials and labour for 12 to 15mm thick granite (width and length as per site requirement)in vertical surface over including 12mm thick screed bed in CM 1:3 in pillars jointed with cement slurry and pointed with white cement with the admixture of pigment to match, complete all as specified and as directed.
S&F 20mm thick thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite,complete all as specified and as directed.
M&L Vtirified Ceramic Tiles 10mm thick (Square/ Rectangular) Dark shade polished, area of each Tile not exc. 0.36 Sqm, in Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the surface of tiles complete all as specified and as directed
M&L Cement Concrete 1:3:6, Type C2, (40mm graded aggregate) in Foundations, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
M&L 75mm thick Cement Concrete 1:4:8, type D2 (40mm graded aggregate), as in Sub-base finishing Concrete Surfaces Even and rough, complete all as specified and as directed.
M&L 100mm thick Cement Concrete 1:2:4, type B-1 (20mm graded aggregate), as in floor finishing Concrete Surfaces Even and rough, complete all as specified and as directed.
M&L PCC 1:2:4 Type B-1 {using 20mm graded crushed stone aggregate} as in coping, kerbs, mud stop, benching etc including weathering, slightly rounded or chamfered angles and throating etc including necessary form work, complete all as specified and as directed.
M&L preparing newly plastered surfaces of wall and applying Three Coats of White Wash, complete all as specified and as directed
Supply only Integral Water Proofing Compound, conforming to IS-2465-1975 and/or as approved, complete all as specified and as directed.
Supply only liquiedWater Proofing Compound, complete all as specified and as directed.
M&L for Two coat of Oil bound distemper on ceiling of verandah including a coat of chalk whitening including preparation of surface, complete all as specified and as directed..
M&L preparing newly Plastered Surfaces of Walls and applying Two Coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M&L preparing newly plastered surfaces of Walls and applying Two Coats of Cement Base Paint over a coat of primer, complete all as specified and as directed.
M&L preparing old treated/decorated Wood and Wood Based Surfaces of any description, not otherwise described, over 10 Cm width or girth and applying two Coat of Synthetic Enamel Paint (First grade quality), complete all as specified and as directed.
M&L preparing new or previously untreated Steel and Iron Surfaces of any description, over. 10 Cm Width or Girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M&L preparing old treated/decorated Steel and Iron surfaces of any description, not otherwise described, over 10 Cm Width or Girth and applying One Coat of Synthetic Enamel Paint (1st Grade Quality), complete all as specified and as directed.
Supply & laying Steel Water Tubing 15mm bore (dia), galvanised, ‘medium grade’ with all Fittings, fixed on walls, ceiling or laid in floors or any other situation, complete as all specified and as directed.
All as per Item no. 62 here in before but for 20 mm, complete all as specified and directed.
Refixing only old steel tubing 15mm bore in new or old position as in wall and ceiling or laid in floors complete as all specified and as directed.
Refixing only old steel tubing 20mm bore in new or old position as in wall and ceiling or laid in floors complete as all specified and as directed.
S&F Rotational Moulded Polyethene Water Storage Tank 1000 Litre Capacity (Cylindrical, Vertical with Closed Top), 3 layered, hoisted and fixed in Position all as specified in MES Scheduleincluding wash out GI Pipe 32mm of 450mm length with stopper, complete all as specified and as directed. , complete all as specified and as directed.
S&F Ball Valve 20mm dia (minimum Weight 210 Gram), high pressure of PTMT with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe and fixed, complete all as specified and as directed.
S&F in repair vitreous china squatting Orissa pattern Water closet pan, size 580 x 440 mm white, with 'P' or 'S' Trap, integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor, complete all as specified and as directed.
S&F vitreous china wash down water closet pan (pedestal pattern) white incl seat cover of plastic, CP jet and pipe etc complete incl necssary PVC pipe fittings, complete all as specified and as directed.
S&F in repair vitreous china bowl urinal flat back, size of 465x355x265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe , and waste pipe), complete including providing and fixing plugs, bedding urinal against wall in CM 1:2 and incl 60cm long brass screws pointing around urinal back in cement etc complete all as specified and directed.
S&F in repair PVC Flushing Cistern 10 Litre capacity White, Low Level, valve less, syphonic action type with Inlet, Ball Valve, Float and handle, a pair of Cast Iron Brackets Erecting Stand duly painted including cutting and pinning in ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and fixed, complete all as specified and as directed.
S&F Vitreous China Wash Hand Basin 550x 400mm in size, White (Flat Back or Angle Back Type) with 32mm bore waste coupling of PTMT (half or full threaded of minium weight 32-445gms), a Pair of Cast Iron Brackets duly Painted/ Erecting Stand including Cutting and Pinning in Ends, Making Good disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed.
M&L HDPE waste pipe of 32mm dia pressure rating 6 Kgs/Sq cm fixed complete to walls floors etc, complete all as specified and as directed.
S&F in repair bib Tap 15mm bore (dia), Cast Copper Alloy, Chromium Plated with Crutch or Butter-fly Handle, screwed down, screwed for Iron Pipe or for Brass Ferrule and fixed, complete all as specified and as directed.
S&F in repair pillar Tap 15mm bore (dia), Cast Copper Alloy, Chromium Plated with Capstan Heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed Shanks and Fly-nuts, screwed for Iron Pipe and fixed, complete all as specified and as directed.
S&F PVC Connection Pipe 15mm in size with PTMT Nuts of length 450mm and fixed, complete all as specified and as directed.
S&F Stop Cock 15mm bore , Chromium Plated, screwed down high pressure with Crutch or Butter-fly Handle, screwed both Ends for Iron Pipe or for Unions and fixed, complete all as specified and as directed.
S&F in repair Angular stop cock 15mm bore fancy type Chromium Plated , concealed type screwed down high pressure with crutch or butterfly handle, screwdd both ends for iron pipe or for unions and fixed complete all as specified and as directed.Make Somany Cat No 210308
S&F in repair brass Chromium plated Shower Rose 125mm size, with or without Swivel Joints, and fixing to Steel Pipe or Union and fixed, complete all as specified and as directed.
S&F Sheet Glass Shelf/corner Assembly, consisting of 5.5mm thick Sheet Glass Shelf 12 Cm Wide with Chromium plated Bracket Guard and Railing 60 Cm long, complete all as specified and as directed.
S&F Brass Chromium plated Tubular Towel Rail, 20mm dia, D-type, 60 Cm long between Flanges with Bracket (one Pair) and fixed, complete all as specified and as directed.
S&F in repair, PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, Single Socketed, in any length with Rubber Ring Joints, laid in Trenches or in Floors complete all as specified and as directed.
All as per Item no.83 here in before but for 75 mm, complete all as specified and directed.
S&F in repair PVC (SWR) 110 mm bore (dia) Bend any type, and jointing with Solvent Cement, complete all as specified and as directed.
All as per Item no.85 here in before but for 75 mm, complete all as specified and directed.
S&F PVC (SWR) 110 mm bore (dia), Junction Single (Single T) Equal or Unequal with Access Door, etc. jointing with Solvent Cement, complete all as specified and directed..
All as per Item no.87 here in before but for 75 mm, complete all as specified and directed.
S&F PVC (SWR) floor trap, plain with grating, Diameter of outlet 75mm, including jointing with solvent cement complete all as specified and as directed.
Taking out existing worn out Bitumenous Felt by cutting, chiseling, scrapping, etc. including PCC Roof Padding not exc. 50mm thick if any, cleaning the surfaces by booming, brushing, washing, etc, removing dust, debries/ rubbish, etc. from the Site to a distance exc. 50.00 Metre and not exc. 100.00 Metre, complete all as specified and as directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top:- (i) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying as in roof Slab. (ii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be applied over screed bed as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction and sealing the joints with application of cold bitumen. (iii) Applying Two coat of aluminum paint over the APP membrance .
Supplying, laying and testing of 200 mm internal dia of double wall corrugated (DWC) high density polyethylene pipe (HDPE) and stiffness classes 8 (SN-8) with ISI marked (With CML No ) with and including all fittings & jointing materials for sewage line and laid in trenches as specified in IS-16098-2013 part-2 complete all as specified and as directed. Make - Rex Polyextrusion Pvt Ltd/Jain irrigation System Ltd/Alom Poly extrusions Limited. Note :- Bedding of pipe shall not be provide in normal condition, but PCC bed blocks 200mm thick around the pipe shall be provided to hold the joints and mid part of the pipe and construction methods shall be strictly complied as per clause No A-4 of Annex 'A' of IS 16098 Part II. Rates of PCC bed block shall be deemed to be inclusive in the rate quoted by the contractor for DWC pipes, complete all as specified and as directed.
Supplying, laying and testing of 300 mm internal dia of double wall corrugated (DWC) high density polyethylene pipe (HDPE) and stiffness classes 8 (SN-8) with ISI marked (With CML No ) with and including all fittings & jointing materials for sewage line and laid in trenches as specified in IS-16098-2013 part-2 complete all as specified and as directed. Make - Rex Polyextrusion Pvt Ltd/Jain irrigation System Ltd/Alom Poly extrusions Limited. Note :- Bedding of pipe shall not be provide in normal condition, but PCC bed blocks 200mm thick around the pipe shall be provided to hold the joints and mid part of the pipe and construction methods shall be strictly complied as per clause No A-4 of Annex 'A' of IS 16098 Part II. Rates of PCC bed block shall be deemed to be inclusive in the rate quoted by the contractor for DWC pipes, complete all as specified and as directed.
Excavation in trenches not exc. 1.5 Metre Wide and not exc. 1.50 Metre in Depth for foundation etc. or for Shafts, Wells, Cess Pits, Manholes, Pier Holes for laying of UG Cable/Pole/Stays etc, and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Excavation in trenches not exc. 1.5 Metre Wide and exc. 1.50 Metre and not exc. 3.0 meter in Depth for foundation etc. or for Shafts, Wells, Cess Pits, Manholes, Pier Holes for laying of UG Cable/Pole/Stays etc, and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
M&L for construction of soakage wells of size 3.60 mtr dia x 4.50 mtr deep (Effective depth 4.50mtr) excavation in soft/loose soil, foundation in PCC 1:3:6 type C-2, walls of honey combed and solid RCC 1:1.5:3 type A1 (using 20 mm aggregate) concrete including interepting chamber, screen chamber, brick work in CM 1:4, RCC cover slab in RCC 1:1.5:3 type A1 (using 20 mm aggregate) concrete, RR Masonry and filling with brick bats, complete all as spd and directed and shown on TD-309 sheet 1/4 to 4/4 incl demolition of old soakage well and buried into the ground, making surface even and good, complete all as specified and as directed.
Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) of any description on batten/conduit and making good disturbed surfaces of Ceiling, Walls, etc. in Cement Mortar 1:3 and providing Surface Treatment so as to match the existing Finishes, complete all as specified and as directed.
Taking down the existing unservicable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down old unserviceable/burnt Submain Wiring with copper /aluminum conductor PVC insulated cable of any size drawn through PVC Casing Caping/Conduit including GI Wire Accessories etc. and making good disturbed surfaces of Walls, Ceiling, etc. so as to match the existing Finishes, complete all as specified and as directed.
Taking down the existing unservicable UG cable of any type/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down ceiling fan of any sweep, keeping with safe custody and refixing the same with replacement of unserviceable 3 core PVC insulated, PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal, Overhauling the fan, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm Copper Conductor single core PVC insulated Flame Retardant Low Smoke (FRLSH) Unsheathed 1100 Volt grade multi-stranded Cable drawn through and including Rigid PVC Conduit, medium grade, ISI marked of suitable size and its Accessories as required at Site, fixing on surface of Wall, Roof, mounted on Sunk Mild Steel Pressed Terminal Box 1.22mm thick of suitable size duly painted with red oxide metal primer with 3.0mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, etc. including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 1.5 Sqmm (FRLS) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Light Point controlled by One 1-Way Switch 5 Amp, complete all as specified and as directed.
All as per item No. 104 here in before for One Ceiling Fan/Exhaust Fan Point controlled by One 1-Way Switch 5 Amp and Regulator, complete all as specified and as directed.
All as per Item no. 104 here in before but for 3pin 5Amps switch socket outlet point controlled by One Switch on the Same Board, complete all as specified and as directed.
All as per Item no. 104 here in before but or One 3 Pin 5 Amps Switch Socket Outlet Point controlled by One Switch on Independent Board, complete all as specified and as directed
Description all as per item No 104 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 2.5 sq mm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S&F Switch Piano, Flush type, Single Pole, 1-Way, 5 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Socket Outlet, 2-in-1, Flush type, multi-purpose, 2/3 Pin, 5 Amp, 230 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 2-in-1, Flush type, multi-purpose, 2/3 Pin, 5 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 2-in-1, Flush type, multi-purpose, 3 Pin, 15 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Ceiling Rose, Surface Bakelite of size 65x50mm, 3 Terminals, AC, 50 Hz, 240 Volts, conforming to IS and connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator, Step type, Flush type, heavy duty, suitable to work on 230 Volt, AC supply and connecting up, complete all as specified and as directed.
S&F Lamp Holder Surface Bakelite with Back Plate insulated body suitable for Batten/Angle Fittings and fixed with PVC Block, conforming to IS and connecting up, complete all as specified and as directed.
S & F LED ADORE 10 W B22 CDL 5 STAR LAMP with B 22 base capacity 1200 lumen complete all as specified.Make Havells, Cat No: LHLDEUEBML8Z010 or equivalent in CG or Polycab.
S & F sheet metal enclosure MCB VTPN 6 way Double door Ready to use DBs - Provided with insulated vertical phase bus-bars |neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels With provision for 4 Pole MCCB 100 A as incomer and SP/SPN MCBs as outgoing complete all as specified and directed.
S&F Sheet Metal Enclosure MCB DB, SPN, 8-way with 200 Amp rated Bus-bar, 240 Volt, Double Doors with Magnitic Locking System and connecting up, complete all as specified and as directed.
S&F MCB Double Pole, 20 Amps, 240/415 Volt for fixing on MCB DB’s, 10 kA,c curve 50 Hz, conforming to IS/IEC 60898 and connecting up, complete all as specified and as directed.(Make- L&T, Cat No: BB20320B, Schinder & Legrand.)
S&F MCB SP,6 Amps, 240 Volt for fixing on MCB DB’s, 10 kA,c curve 50 Hz, conforming to IS/IEC 60898 and connecting up, complete all as specified and as directed.(Make- L&T, Cat No: BB10060B ,Schinder & Legrand.)
S & F wall mounted LED 18 watts , box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 18 watts complete all as specified and as directed. Make-Model -REGALBATTENT5UPTO1X18WDSBSWH For Batten Fitting and Model-PHOTONULTRAE2.01213T8SSTL18WLED865SPC For T8 Tubelight ,Make Havells, or equivalent in CG, Polycab.
S&F CIMFR Certified LED Flameproof batten suitable for single and twin T8 tube of 16W/20W Recommended for Gas/Vapour group of IIA & IIB and zone 1 & 2.IP 65 protected. Model-EXTN1LT8-8, Make-CG
S&F CIMFR Certified LED Flameproof wellglass in die cast AL housing with heat resistant toughened glass. Recommended for Gas/Vapour group of IIA & IIB and zone 1&2. IP 65 protected. Model-GLAZE PRO, FWL1315-30-CDL, Make-CG.
S&F LED Polycarbonate T8 18 W tube with in built driver with metal heat sink, Double sided connection for LED Flameproof batten complete all as specified and directed. Model:- 565-2 (ULTRON), Make:- CG
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 15 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete all as specified and as directed.Make-Havells,Model No - ENDURAPEARLSL25WLED757SASYTOPCMP Or Equivalent in CG and Polycab
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after lay-ing the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE: For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for.
S&F Sub-Class ‘B’ Brick, well burnt, laid breadthwise along the length of Cable laid in trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
Supply & laying LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 35 Sqmm 3.5 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connec-tion to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and Testing, complete all as specified and as directed. NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
Supply & laying Steel Water Tubing 50mm bore (dia), Galvanised, ‘light grade’ with all Fittings,in protection of cable at road crossing/hard standing/pole protection fixed with clam as per site or any other situation, complete as all specified and as directed.
All as per Item no.129 here in before but for 25 mm, complete all as specified and directed.
M & L for sub main wiring with two single runs of single core 6.0sqmm PVC insulated unsheathed multisreanded 1100 volts grade with copper conductor drawn through and including PVC casing caping ISI marked and its accessories including one run of single core 6.0 Sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth contuinity conductor along with the wiring and connected from DB to DB/ main board complete all as specified.
Boring holes horizontally under road without damaging the surface of road of any type (minmum 1.0 metre below the raod surface with the help of GI Tubing not ex. 50mm bore (dia) for passing of UG cable, complete all as specified and as directed. NOTE : GI Pipe laid will be measured and paid separately under appropriate item.
M&L Earthing complete with Galvanised Steel Earth Plate Electrode 600x600x6mm, buried directly in ground vertically to a depth not less than 2.25 Metre below ground level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal ground level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) ‘light grade’ upto 1.0 Metre above the Floor Level of Building where Main Switch/ DB situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded aggre gate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded aggregate), reinforced with 8.0mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’ including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including removal old existing unserviceable Earthing, complete all as specified and as directed.
Taking down the existing unserviceable water supply pipeline of any size as existing at site including making good the disturbed surfaces to match with the existing finishes, complete all as specified and as directed.
S&F Gunmetal globe (Class 2) or gate valves (brass insert), with iron wheel head screwed both ends for iron pipe size 40 mm dia, complete all as specified and as directed.
All as per Item no.135 here in before but for 25 mm, complete all as specified and directed.
Cutting of existing CI pipe laid 80 mm dia for inserting Tees for new connection of 80mm x 50mm dia, complete all as specified and directed.
M&L for GI connection pieces for inserting 25 mm GI pipe into 50 mm distribution mains all as specified and directed.
M&L for fixing GI plug into 50mm distribution mains all as specified and directed.
S&F energy efficient ceiling fans AC 230 volts single phase 1200mm sweep complete with all accessories including MS hook, nuts, bolts and washer for hanging arrangement complete including provn of 3 core PVC insulated, PVC sheathed 3 core multistranded copper conductor cable from ceiling rose to fan terminal complete all as specified and as directed. Make:- Usha, Model- Technix plus/ Bjaj/crompton
Satya Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .