Tender Value
₹5.3 Cr
EMD Value
₹10.6 L
Closing Date
15 Jun 2026, 12:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER SIG
16 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. (As per Rly. Bd. letter No. 2022/CE-I/CT/GCC-2022/Policy dated 14.07.2022).
As per Tender Document Attached of GCC-2022
15 conditions · 10 needing a document upload
As per Tender Document Attached of GCC-2022
As per Tender Document Attached of GCC-2022
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Replacement of defective S&T cables, Decayed/worn-out Location Boxes, overaged track relays and other equipments in section of DSTE/KQR & ASTE/GMO.
SG-664-06-Sig-2026-27
SG-664-06-Sig-2026-27
Open
Works - General
12 Months
Dhanbad, Jharkhand
₹0
₹10.6 L
15 Jun 2026
22 May 2026
1 Jun 2026
307 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | 5.00 | — | — | ||
| Fixing, wiring of terminal strips, Bakelite strip, transformers, relays fuses with base and supply and fixing of shelves for Half apparatus case with termination earthing of cable and wiring with lettering as required including supply of wires and miscellaneous materials, sand filling and plastering over sand filling per location.(All materials except transformers, relay, terminal strips, Bakelite strip and fuses with base to be supplied by the contractor.) | — | — | — | 12,488.85 | |
| — | 100.00 | — | — | ||
| Reinstatement of platform and repairing to original state after cable laying work. | — | — | — | 39,962 | |
| — | 150.00 | — | — | ||
| Repair of Pucca Roads to original state in level x-ing area after cable laying works. | — | — | — | 65,109 | |
| — | 10.00 | — | — | ||
| Casting, concreting and curing of foundation for Main signal and as per DRG.No.SGW/MGS/S1/91 including COST of all materials required for casting and concreting and provision of holding down bolts & nuts. | — | — | — | 94,238.3 | |
| — | 6.00 | — | — | ||
| Casting, concreting and curing of foundation for Shunt signal and as per DRG.No.SGW/MGS/S1/91 including COST of all materials required for casting and concreting and provision of holding down bolts & nuts. | — | — | — | 23,785.2 | |
| — | 250.00 | — | — | ||
| "Fixing of galvanized iron trucking with cover of same materials as per DRG. No. SGW/MGS/C7/91 and fixing on girder bridges including supply of channel, angle iron, bracket units, nuts and bolts of proper size & fitting of support at an interval of 1mtr including laying of cables inside the trough & filling with bitumen compound as per spec. no. IRS:TC-25/76 after cable is laid. Bitumen compound and other materials as required for the work shall be supplied by the contractor b)Execution.Portion." | — | — | — | 2,02,705 | |
| — | 204.00 | — | — | ||
| "Supply of G.I. Pipe with threaded collars of 100 mm nominal bore specn. No. IS 1239 medium grade. Perforated of required length on bridge / below metaled road/ L-xing /Culvert as per technical specification of tender. A) Supply portion for the G. I. Pipe & collars. Inspection Consignee" | — | — | — | 2,53,312.92 | |
| — | 204.00 | — | — | ||
| "Fixing of G.I. Pipe with threaded collars of 100 mm nominal bore specn. No. IS 1239 medium grade. Perforated of required length on bridge / below metaled road/ L-xing /Culvert as per technical specification of tender. B) Execution with remaining miscellaneous materials." | — | — | — | 19,118.88 | |
| "Excavation of Trench in all kinds of soil and refilling of trenches (1.2 Mtr, Depth, 300 mm Width) - without bricks. Note:- (I) Payment will be made as per actual work done on pro rata basis, if required depth is not available at site. (II) If the depth of trench is not uniform in a span of 100 mtr.or shorter length, if site condition demands along the cable run minimum depth will be taken for that particular stretch for payment." | — | — | — | 27,81,030 | |
| — | 61.00 | — | — | ||
| "Laying cables of different sizes as per cable route plan approved by Railway and meggering of all main & tail cables as per technical specification of tender. ii) 2 core to 12 core signalling cable" | — | — | — | 7,17,172.12 | |
| — | 4.00 | — | — | ||
| Supply of Relay, Non-AC Immune plug-in type, Style 'QNN1", Twin DC Neutral ling, 24V, 6F/2B , 25 contacts each for LH and RH, front and back contacts metal to carbon,. Complete with plug board, 24 retaining clip &corinectors conforming to BRS: 960, IRS S 348 IRS:S 23 (as applicable). The interlocking code for this unit shall be ACDEK. Inspection RDSO | — | — | — | 24,442.24 | |
| — | 4.00 | — | — | ||
| Supply of fail safe electronic time delay device mounted on Q series relay base & covered with fixed timing of 120 sec. As per RDSO Spec.no.IRS-5-61/2000, IRS-S-34 & IR5-5-23 (as applicable). Interlocking code for this relay shall be AFGKY. Inspection RDSO | — | — | — | 46,563.92 | |
| — | 23.00 | — | — | ||
| "Supply of True RMS Digital multimeter 3 -3/4 digit Autoranging digital multimeter with AC/DC voltage +AC/DC current & Resistance + Analog +barograph + Diode +Continuity + Frequency +Capacitance + Min/Max Storage + Data hold+ Temp+ Duty Rubber hoiser. Make Fluke or similar. Inspection Consignee" | — | — | — | 2,56,296.13 | |
| — | 1.00 | — | — | ||
| Supply of Cable route tracer as per latest technical specification No. G/TIE/-01/02 Oct 99 with latest amendment No. 1 date 29-0- 200 & 03/06/2004, Telemetrics Model-CR. Inspection Consignee | — | — | — | 5,19,627.13 | |
| — | 851.00 | — | — | ||
| Supply of Non deteriorating type low voltage cartridge fuse as per Spec. No. IRS/S/78/92. Round head type. (b) 6 Amp. Capacity. Inspection RDSO | — | — | — | 1,03,217.79 | |
| — | 425.00 | — | — | ||
| Supply of Non deteriorating type low voltage cartridge fuse as per Spec. No. IRS/S/78/92. Round head type. (c) 16 Amp. Capacity. Inspection RDSO | — | — | — | 48,080.25 | |
| — | 44.00 | — | — | ||
| Loading & unloading of heavy S&T materials in 15 MT Truck. | — | — | — | 4,63,596.32 | |
| — | 8522.00 | — | — | ||
| Transportation of materials 15 MT capacity truck | — | — | — | 10,09,090.02 | |
| — | 1.00 | — | — | ||
| Supply, transportation, installation & commissioning electrically operated lifting barrier set as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest each consisting of 2 nos. of lifting barrier pedestals, each with min. 6 contact circuit controller with top roller type limit switches, hand crank, 2 electric motors, 110VAC of capacity suitable to operate barriers upto 32' long booms, 2 nos. of steel octagonal booms of 32' length with 2 nos. stop boards. Boom light boxes, ms counter weights and 2 nos. of boom support with suitable boom locking but without fringes along with control panel with buttons and indicating lamps, motor connectors and mcb to operate 2 barriers of 1 set. this includes supply and installation of gate hooter - 1 no. and horn ( 8 watt) - 1 no. with all fixing arrangements. All of the above items including supply of cement, civil work materials etc. shall be done by the contractor for commissioning. 230vac supply only shall be arranged by the railway in near by relay room.(Complete set ) (i) Supply. Inspection RDSO | — | — | — | 4,43,339.49 | |
| — | 1.00 | — | — | ||
| "Supply, transportation, installation & commissioning electrically operated lifting barrier set as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest each consisting of 2 nos. of lifting barrier pedestals, each with min. 6 contact circuit controller with top roller type limit switches, hand crank, 2 electric motors, 110VAC of capacity suitable to operate barriers upto 32' long booms, 2 nos. of steel octagonal booms of 32' length with 2 nos. stop boards. boom light boxes, MS counter weights and 2 nos. of boom support with suitable boom locking but without fringes along with control panel with buttons and indicating lamps, motor connectors and MCB to operate 2 barriers of 1 set. this includes supply and installation of gate hooter - 1 no. and horn( 8 watt) - 1 no. with all fixing arrangements . All of the above items including supply of cement, civil work materials etc. shall be done by the contractor for commissioning. 230vac supply only shall be arranged by the railway in near by relay room.(complete set ) (ii) Execution" | — | — | — | 56,797.41 | |
| — | 10.00 | — | — | ||
| "Installation, erection and wiring of CLS unit (Non-Metallic (FRP) colour light signal housing multi-unit type), LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, Two aspect complete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA-23003/A/M/ADV,ALT-8 and as per Spec No RDSO/SPN/194/2006 (version 1.0) with latest amdt and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. NOTE: - Installation, erection & wiring of signalling unit includes LED signal litghtening unit including current regulator. This also includes protection of unit from Rain water. Signal unit should be compatible to 'LED type. (i) Supply. Inspection Consignee" | — | — | — | 3,37,777.6 | |
| — | 3.00 | — | — | ||
| "Installation, erection and wiring of CLS unit (Non-Metallic (FRP) colour light signal housing multi-unit type), LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, Two aspect complete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA-23003/A/M/ADV,ALT-8 and as per Spec No RDSO/SPN/194/2006 (version 1.0) with latest amdt and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note: - Installation, Erection & wiring of signalling unit includes LED signal litghtening unit. This also includes protection of unit from rain water. Signal unit should be compatible to LED type (ii) Execution" | — | — | — | 6,338.04 | |
| — | 10.00 | — | — | ||
| "Supply Installation, erection and wiring of CLS unit (Non-Metallic (FRP) colour light signal housing multi-unit type), LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, THREE aspect complete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA- 23002/A/M/ADV,ALT-8 and as per Spec No RDSO/SPN/194/2006 (version 1.0) with latest amdt and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. NOTE:- Signal unit should be compatible to 'LED type. NOTE:- Installation, erection & wiring of signalling unit includes LED signal lightining unit including current regulator. This also includes protection of unit from Rain water. (i) Supply. Inspection Consignee" | — | — | — | 3,66,182 | |
| — | 3.00 | — | — | ||
| "Installation, erection and wiring of CLS unit (Non-Metallic (FRP) colour light signal housing multi-unit type),LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, THREE aspect complete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA- 23002/A/M/ADV,ALT-8 and as per Spec No RDSO/SPN/194/2006 (version 1.0) with latest amdt and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. NOTE:- Signal unit should be compatible to 'LED type. NOTE:- Installation, erection & wiring of signalling unit includes LED signal lightining unit including current regulator. This also includes protection of unit from Rain water. (ii) Execution of item no. 08010300" | — | — | — | 7,725.84 | |
| — | 10.00 | — | — | ||
| "Supply, Installation, erection and wiring of CLS unit (Non-Metallic (FRP) colour light signal housing multi-unit type), LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, FOUR aspect complete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA-23002/A/M/ADV,ALT-8 and as per Spec No RDSO/SPN/194/2006 (version 1.0) with latest amdt. and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. NOTE:- Installation, erection & wiring of signalling unit includes LED signal lightning unit including current regulator. This also includes protection of unit from Rain water. Signal unit should be compatible to 'LED type. (i) Supply. Inspection Consignee" | — | — | — | 4,43,560.8 | |
| — | 3.00 | — | — | ||
| "Installation, erection and wiring of CLS unit (Non-Metallic (FRP) colour light signal housing multi-unit type) LED unit including paying out of tail cable from Location Box and earthing of CLS (LED type).This includes supply of Non Metalic (FRP) Color light signal housing multi unit type for Railway signalling suitable for RE area, FOUR aspect complete (without lenses, lamps and signal transformer) as per RDSO Drg. No. SA- 23002/A/M/ADV,ALT-8 and as per Spec No RDSO/SPN/194/2006 (version 1.0) with latest amdt and FRP material as per RDSO Spec No. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. NOTE:- Signal unit should be compatible to 'LED type. NOTE:- Installation, erection & wiring of signalling unit includes LED signal lightining unit including current regulator. This also includes protection of unit from Rain water. (ii) Execution" | — | — | — | 10,174.41 | |
| — | 10.00 | — | — | ||
| Supply, Installation, erection paying out of S&T tail cable from LB and wiring of Calling-on signal/Guard repeater, LED unit on same post below main signal. This Includes supply of Non Metalic (FRP) Calling-on signal unit for Railway signalling suitable for RE area without lens, lamp & holder compatiable to LED signal unit as per RDSO Drg. No. SA-24351 (ADV) or latest and as per RDSO Spec No ADSO/SPN/194/2008 version 1.0 with latest amdt FRP material Spec No, as per RDSO/SPN/151/1997 or latest. This includes cost of protection cover (wire mesh guard of expended metal of size 2x 1 and mounting bracket with U clamps, nuts, bolts & washers. All drawings should be as per latest. NOTE:- Installation, erection & wiring of signalling unit includes LED signal lightining unit. (i) Supply. Inspection Consignee | — | — | — | 1,24,478.6 | |
| — | 10.00 | — | — | ||
| "Supply of Junction route indicator unit TWO WAY (Without Lenses & Holder) as per Drg. No. RDSO SA 23402 suitable for LED Signal Lighting Unit & as IRS:S-66/84 amndt-1 or latest (LED type). This includes supply of non-metallic (FRP) Junction Type Route Indiator for Rly signalling suitable for RE area without lamp, lenses, and signal transformer as per RDSO spec. no. RDSO/SPN/194/2006 (VER- 1.0) With latestamdt .All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note:- Installation, Erection & Wiring of signalling unit includes LED signal litghtening unit. This also includes protection of unit from rain water. Signal unit should be compatible to 'LED' type,. (i) Supply of TWO WAY as per RDSO drg. no. SA- 23402(ADV)/ALT-2-. Inspection Consignee" | — | — | — | 5,68,501.1 | |
| — | 3.00 | — | — | ||
| "Installation, Erection and wiring of TWO Way Junction Type Route Indiator (LED type). This includes supply of non-metallic (FRP) Junction Type Route Indicator for Rly signalling suitable for RE area without lamp, lenses, signal transformer as per RDSO spec. no. RDSO/SPN/194/2006 (VER- 1.0) With latest amdt. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note:- Signal unit should be compatible to 'LED' type, Note:- Installation, Erection & Wiring of signalling unit includes LED signal litghtening unit. This also includes protection of unit from rain water. TWO Way as per RDSO drg. no. SA- 23402 (ADV)/ALT-2- (ii) Execution" | — | — | — | 4,800.18 | |
| — | 4.00 | — | — | ||
| "Supply, Installation, erection paying out of tail cable from LB and wiring of Shunt signal LED unit as per technical specification. This includes supply of Non Metalic (FRP) Shunt signal housing multi unit type (without lenses, lamps &signal transformer) with base & post for Railway signalling suitable for RE area compatible to LED signal unit as per RDSO Drg. No. SA-24351 (ADV) or latest and as per RDSO Spec No. RDSO/SPN/194/2006. version 1.0 with latest amdt. FRP material Spec No, as per RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Inspection: RITES, NOTE:- Installation, erection & wiring of signalling unit includes LED signal lightining unit. (i)Supply. Inspection Consignee" | — | — | — | 70,258.52 | |
| — | 4.00 | — | — | ||
| "Installation, erection paying out of tail cable from LB and wiring of Shunt signal LED unit on the post as per technical specification. This includes supply of Non Metalic (FRP) Shunt signal unit (without lenses, lamps, base, and post and signal transformer) as per RDSO Drg.No. SA- 23840/ADV/Alt- 12 or latest. Material to be procured from RDSO's approved firm only. NOTE:- Signal unit should be compatible to 'LED type. NOTE:- Installation, erection & wiring of signalling unit includes LED signal lightining unit including Current regulator & health monitoring unit. This also includes provision of offset bracket and protection of unit from rain water. a) Execution" | — | — | — | 2,335.4 | |
| — | 7.00 | — | — | ||
| Supply of SLB/BSLB/SB for SLB/BSLB REF. RDSO DRG. No.SA- 2373(with latest amendment). Inspection Consignee | — | — | — | 16,467.15 | |
| — | 7.00 | — | — | ||
| Casting, Concreting and curing of foundation & erection for SLB/BSLB/ SB as per DRG.No. S&T/C-34 (NKG). Including supply & fixing of holding down bolts & nuts. | — | — | — | 68,315.59 | |
| Transportation of less heavy materials & manpower by supply & running of one MUV to the sites of work as per requirement and direction of Engineer-in-charge along with driver. The rate includes all taxes, license fee, road permit, driver wages, fuel, repair and maintenance cost etc, complete in all respects. | — | — | — | 22,40,005 | |
| — | 8.00 | — | — | ||
| "Supply of Earth Leakage Detector (ELD), LEVEL-3, as per RDSO Spec. RDSO/SPN/256/2025 or latest., with Earth Fault Localization system. The engineer-in-charge to specify the distribution of number of channels of DC or AC voltage on the bus bar/ conductor for which earth leakage detector is required. 12 Channel Earth Leakage Detector. Inspection RDSO" | — | — | — | 16,27,748.08 | |
| — | 50.00 | — | — | ||
| Supply of Bravo Visitor Chair, Make Godrej or Similar. Inspection Consignee | — | — | — | 4,47,950 | |
| — | 75.00 | — | — | ||
| Supply of Godrej Office table model T-8 or better. Inspection Consignee | — | — | — | 15,49,461 | |
| — | 19.00 | — | — | ||
| Supply of Steel almirah big size-78"x36"x19" having four shelves with 5 compartments of C.R. sheet 22 gauge with spray painting. ( Model BSW-AL-2B ) - to keep records of Data logger, Axle counter, IPS, MSDAC etc. Inspection Consignee | — | — | — | 2,90,460.98 | |
| — | 1.00 | — | — | ||
| "Supply, installation, Testing & commissioning of Data Logger System for Rly. S&T. Installation as per RDSO Specification no.IRS: S:99/2006 with (Amdt:3) with 1024 Digital input and 32/64 Analog inputs with supply of required EI modems, protocol converter, Dual card RS 232 to E1 converter etc. Data Logger to be provided with suitable PC with extra 1 TB storage device, laser printer hp-1020 & furniture. Note: All materials & equipmets required for installation, testing, commissioning & Networking with Control to be supplied and done by the firm. Inspection RDSO" | — | — | — | 5,37,027.27 | |
| — | 1.00 | — | — | ||
| "Supply of Micro Processor based Remote Terminal Unit (RTU) with 64 digital inputs & 16 analog inputs with A4 Laser printer 22 ppm (Only baranded HP/Brother/Canon) as per RDSO Spec. No. IRS (8) 99/2006 with Amdt. 3.0 or latest. It includes supply of all the items required for complete indoor relay room wiring from RTU to relay rack tag blocks, drawing/extension of power supply up to RTU. It includes supply of relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD (if installed), IPS, interlinking and networking of RTU. It also includes supply of leased line MODEM, suitable online UPS (minimum 6 hours' backup) and other interfacing cards, if required for networking of Data Logger. Note: (1) Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines of Railway Board/RDSO/Zonal Railway. (2) Exceptional reports are to be generated by a computer connected to datalogger at the station and at a central location in Control Room. Datalogger software should be able to generate exceptional reports for maintenance, safety and operations as per latest guidelines of Railway Board/RDSO/Zonal Railway. Datalogger to be installed at Site by OEM. Manufacturing date of RTU and printer should be of current year at the time of supply. Inspection RDSO" | — | — | — | 1,75,935.41 | |
| — | 1809.00 | — | — | ||
| "Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring of 110mm dia or above to suit site requirement and placing HDPE pipe of size 63 to 50 mm in single / double /triple etc required for crossing/laying of RailwayS&T cables in a combination of quad & signalling cables etc. as per required comprising upto 72 cores in any HDD section on land/bridges / culverts / track /pucca road crossing and blowing pulling of Quad /S&T cables within HDPE pipe. Boring of trench shall be minimum 3 (three) meter or more below the river bed, 01 (one) Mtr below or more the track and 1.5 (one point five) meter below or more other lands including road /pucca road crossing area. This includes supply of permanently lubricated HDPE pipe of size 63 to 40 mm dia& its accessories suitable for HDT as per Specification No.RDSO/SPN/TC/45/2013 Rev.2.0 with Amdt. 3 or latest amendment & cost of the fuel and all other items which will be required for laying of cable through it. Inspection : RITES for HDPE pipe NOTE: The number of HDPE pipes (of any dia as mentioned above) to be pulled in any HDD section will depend upon the numbers of S&T cables to be pulled through that HDD section as per site requirement. At a particular site, the second / additional HDD is to be done only after completing the pullingof 72 cores of cable through 1st HDD other wise the second / additional HDD will not be counted as a new/additional HDD for the purpose of billing. Only S&T cables to be supplied by Railway. Printed Cable sketch plan showing dirversion& depth, which shall be generated by machine to be submitted by firm just after every boring & to be submitted while billing." | — | — | — | 31,33,151.82 | |
| — | 425.00 | — | — | ||
| — | 185.00 | — | — | ||
| — | 4750.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Document
ATTACHMENT
TenderDocument-SG-664-06-Sig-2026-27.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .