Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC H NO 23 14 VILL RAHIMPUR ROORKEE | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.4 L+₹1,905 (0.07%)Rejected-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance Rejected being not L1 | |
| 3 | L3₹29.2 L+₹83,304 (2.94%)Rejected-AOC 561 MOHALLA KHAIRAT ALI MAWANA KALAN MEERUT UTTAR PRADESH 250401 | MEERUT | UTTAR PRADESH | 250401 | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹29.3 L+₹93,310 (3.29%)Rejected-Finance H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L4 | Rejected-Finance Rejected being not L1 | |
| 5 | L5₹29.7 L+₹1.3 L (4.74%)Rejected-Finance SIDDHARTH ENCLAVE NEAR JINDAL FACTORY RAMNAGAR ROORKEE 247667 | HARIDWAR | UTTARAKHAND | 247667 | L5 | Rejected-Finance Rejected being not L1 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
2 Nov 2023, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Roorkee
REPAIR/REPLACEMENT OF INTERNAL ELECTRIC FITTING/FIXING INCLUDING BUILDING SECURITY LIGHTS, MCB DBs ETC AT POCKET 1 TO 4 OF ROORKEE UNDER GE ROORKEE
2023_MES_621206_1
8392/328/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ROORKEE
As per tender documents
8 documents required · 8 mandatory
₹500
GE (MES) ROORKEE
₹84,000
Yes
13 Jan 2024
30 Sept 2023
6 Nov 2023
30 Sept 2023
2 Nov 2023
14 Oct 2023
Amount
M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm (OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc including taking down existing point wiring cutting chases for concealed wiring and making good in cement mortar (1:4) to match the existing surfaces and applying surface finises such as distempering etc to match the existing shade of building etc complete all as specified and directed for the following :- (a) One light / ceiling fan / exhaust fan / call bell point controlled by one switch
One 3/5 pin 6 Amps socket outlet point on independent board controlled by one, one-way switch.
One 3/5 pin, 6 Amps socket outlet point on the same board with other switches controlled by one, one-way switch.
All as per serial item No.1.00 here-in-before but concealed point wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed FRLS cable for the 16 amps 3/5 pin socket power point controlled by one 16A switch and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed FRLS cable, green colour as earth continuity wire complete all as specified and directed.
All as per Serial item No 1.00 here-in-before but wiring in existing conduit for the following :-
One light / ceiling fan / exhaust fan / call bell point controlled by one switch
One 3/5 pin 6 Amps socket outlet point on independent board controlled by one, one-way switch.
One 3/5 pin, 6 Amps socket outlet point on the same board with other switches controlled by one, one-way switch.
-Ditto- all as per item No. 3.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with cables 2.5 sqmm size complete all as specified and directed.
Taking down old sub main wiring and S&F new sub main wiring with two runs of single core FRLS PVC insulated and unsheathed multistranded, copper conductor cable of size 4.0 Sqmm LT, 1100V grade, drawn through and including adequate sizes PVC non metallic conduit of 20mm / approprite dia with accessories and fittings and one run of 4.0 Sqmm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length. Cable required for connection to DBs shall be deemed to be included and shall not be measured separately. Earth wire shall run inside the conduit pipe complete all as specified and directed. Note :- Extra length of cable required for connection to MCBs shall be deemed to be included in quoted rate)
All as per serial item No. 5.00 above but sub main with two runs of 6.00 Sqmm copper conductor and one run of 6.0 Sqmm as earth continuity conductor complete all as specified and directed.
All as per serial item No. 5.00 here-in-before but sub main with two runs of 10.00 Sqmm copper conductor and one run of 10.0 Sqmm as earth continuity conductor complete all as specified and directed.
All as per serial item No. 5.00 here-in-before but sub main with four runs of 10.00 Sqmm copper conductor and two run of 10.0 Sqmm as earth continuity conductor complete all as specified and directed.
Notes for item No. 1.00 to 8.00: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion. (iv) The quoted rate is deemed to be included the cost of G I sunken box suitable for modular type switches, sockets etc of any module size & shape. (v) The quoted rate is also deemed to be included the cost of cover plate, blank plate of any type and any module. (vi) The Quoted rate is deemed to include for point wiring of any type i.e., normal / concealed / modular type as per direction of Engineer-in-charge.
M & L for Circuit/submain wiring with single core FRLS PVC insulated copper stranded conductor cable drawing into existing PVC rigid conduit surface /concealed/ casing caping as required of 1.0 Sqmm for Inverter wiring, including taking down unserviceable existing wiring etc complete all as specified and directed.
Supply and fix in replacement of switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of socket 6 Amps, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of switch piano flush type 16 Amps, one way, 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of electronic socket type fan regulator rotary type in 5 steps, 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of bell push switch flush type 6 Amps, 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of electric call bell ding dong type, AC, 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of Modular switch 1 way 6A, 1 module 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of Modular switch 1 way 16A, 1 module 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of Modular Socket, 6A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of Modular Socket 6A/16A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of Modular fan regulator step type in 5 steps, 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of Modular Bell push 6A 1 module, 240V, 50Hz complete all as specified and directed.
Supply and fix in replacement of Modular blank plate 1 module complete all as specified and directed.
S&F ceiling rose in polycarbonate 3 terminal brass flush type 6 Amps, 250 Volts AC (ISI marked), fixing on 3 mm thick 75mm dia round sunmica hylum plastic laminated sheet complete all as specified and directed.
S&F Angle / Lamp holder PVC / polycarbonate type B-22 with back plate, complete all as specified and directed.
S & F LED Bulb 9 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder complete all as specified and directed. Make - Halonix (Photon Plus) or equivalent make in particular specifications.
Supply and fix in replacement of LED batten type body pre-wired with bipin holders, connector block complete with all accessories including 20 Watt (4 feet) retrofit LED tube with Polycorbonate body, full white and connecting up with pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed. Make - Halonix or equivalent make in particular specifications.
Supply and fix in replacement of old unserviceable LED T-5 tube light fitting 20 watts with polycarbonate housing and polycarbonate diffuser with integrated electronic driver with all accessories including connecting up with pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed. Make - Polycab Model No LD00103058 or equivalent make in particular specifications. Note: Single/double side connection will be as per direction of Eng-in-Charge
Supply and fix in replacement of old unserviceable LED mirror light light fitting Integral slim LED batten Integral 9 / 10 watts of 2 feet long internally prewired complete with all accessories and including connecting up with PVC insulated and PVC sheathed twisted two core wire of suitable size complete all as specified and directed. Make - Polycab Model No LTU0101009 or equivalent make in particular specifications.
S & F in replacement Decorative wall light fitting, made out of polycarbonate suitable for and including B-22 base LED lamp of capacity 9 watts fixed on wall and making electrical connection complete all as specified and directed. Make - Polycab Model No PGR0301009 or equivalent make in particular specifications.
Supply and fix in replacement of surface / recess mounted LED panel light 4' x 1' size 36 watts, full white/ warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for POP / Armstrong / grid false ceiling complete with all fixing accessories including making electrical connection with PVC sheathed twisted two core cable of suitable size complete all as specified and directed. Make - Polycab Model No PMD0501015 or equivalent make in particular specifications.
Supply and fix in replacement of recessed mounted LED panel light 2'x2' size, 36 watts, full white / warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for POP/ Amstrong / grid false ceiling complete with all fixing accessories including making electrical connection with PVC insulated and PVC sheathed twisted two core wire of suitable sizecomplete all as specified and directed. Make - Polycab Model No PMD0401029 or equivalent make in particular specifications.
Supply and fix in replacement of slim round recessed cum surface mounting LED down light 12 W with aluminium die-cast body, finish with drop down PC diffuser warm / full white with optimized heat sink for efficient dissipation including taking down existing unserviceable light fitting of any description complete all as specified and directed. Make - Polycab Model No PMD0402021 or equivalent make in particular specifications.
Supply and fix in replacement of ventilating / PVC exhaust fans fancy square type 225/250mm sweep with plastic fiber body heavy duty 230 Volt AC, single phase complete with plastic louvers and including making suitable size of holes in wall for fixing the fan & making good including making electrical connection with ceiling rose including taking down existing unserviceable ventilating fan of any description complete all as specified and directed.
Supply and fix in replacement of LED street/security light fitting 25 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps (02 Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed. Make - Halonix (IP66) or equivalent make in particular specifications.
S&F in replacement of old unserviceable LED Flood light fitting 50 Watt capacity with SMD LED pressure die-cast aluminium housing with toughened glass with reflector and high power LEDs IP 66 protection, 5700-6500K including making electrical connection from ceiling rose to light fitting complete all as specified and directed. Make - Halonix (IP66) or equivalent make in particular specifications. Note:- The Quoted rate is deemed to be included for installation of light fitting at any height including necessary T & P and safety equipments.
Supply and fix in replacement of old unserviceable LED Post Top Lantern light fitting 30/40 watt with LED as source light & tranparent diffuser and fixing arrangement on new GI Pipe medium grade of dia 40 mm duly grouted on wall/brick pillar with the help of cement mortar including making electrical connection with pvc insulated and pvc sheathed twisted three core wire of size 1.0 sqmm complete all as specified and directed. Make - Polycab Model No PGR0201008 or equivalent make in particular specifications.
Supply and fix in replacement of old unserviceable Post Top lantern globe type light fitting of capacity 1x7/8 watts with B-22 base LED bulb, transparent polycarbonate diffuser and fixing arrangement on new GI pipe of 25/40 mm dia medium grade of length 1.5m duly grouted on ground/wall/brick pillar with the help of cement mortar including making electrical connection with pvc insulated and pvc sheathed twisted three core wire of size 0.5 sqmm from junction box to light fitting complete all as specified and directed. Make - Bajaj or equivalent make in particular specifications.
S & F in replacement LED bed side lamp of 6/10 watt LED, Magnetic Mounting Base, 360 Degree Movable lamp as source light fixed on existing wall including making electrical connection complete all as specified and directed.
S & F in replacement LED suspension light 40 watt 4 feet long including making electrical connection, suspension system fixing on roof/ceiling with suitable size nut, bolts and fastener complete all as specified and directed. Make-Polycab Model No PLT0101406 or equivalent make in particular specifications.
S&F in replacement LED bollard light 9/10 Watt LED as source light CDL/WW made out of pressure die cast powder coated housing with PC diffuser with LED as a source light including making electrical connection and PCC 1:2:4 work for founation etc complete all as specified and directed. Make - Polycab Model No PGR0201022 or equivalent make in particular specifications.
Supply and fix in replacement of old unserviceable twin core of flexible wire of size 23/0.0076 with PVC medium grade pipe 20mm dia for connection of post top lantern fitting from one junction box to other junction box complete all as specified and directed.
Supply and fix in replacement PVC / DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof suitable for outdoor installation for Gate light and Post top lantern, fixed on wall with screw & rawal plug and on GI Pipe wth suitable size MS clamp and Nut-bolts,washer of size 150x100x60 mm complete including one connector block Four terminals and PVC cable gland 02 Nos for incoming and outgoing cables with provn of 01 nos single pole MCBs 10-32 amps inside the box including taking out/down existing unserviceable junction box of any description complete all as specified and directed.
Supply and fix in replacement of modular MCB protected plug top and socket board (power unit) in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed.
Supply and fix in replacement of MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed.
Supply and fix in replacement of MCB distribution board, TPN, 4 way, 415 V, 3 phase, AC in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed.
S&F in replacement of old unserviceable Distribution Board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar, earth bar, flush to wall complete all as specified and directed .
S&F in replacement of old unserviceable Distribution Board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar, earth bar, flush to wall complete all as specified and directed .
Supply and fix MCCB 100A, 16 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release fixed in Vertical TPN complete all as specified and directed.
Supply and fix in replacement of MCB 100 Amp, 10 KA, TPN, 'C' curve, 415 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed.
Supply and fix in replacement of MCB 63A, 6 KA, SPN, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed.
Supply and fix in replacement of MCB 10A/20A/32A, 6 KA, single Pole, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed.
Supply, Install, testing on completion & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron,UL listed,CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of stainless steel, maxwel back fill compound (earth enhancing compound) shall be of 30kg/pit (resistivity should be less than 0.12 Ohm meter) tested as per IEC 62561-7.The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 240 x 200mm) and FRLS insulated copper conductor of size 6 sqmm, single core cable drawn through and including in rigid non metallic PVC conduit on wall and 15 dia medium grade GI pipe on ground/floor upto 10 mtr incl cutting and chases on wall and floor complete all as specified and directed. Note: (a) The rate quoted above shall be deemed to be included for excavation and earth work, refilling, removal of surplus earth and making good the surface around chemical earthing. (b) Copper Lugs ring/pin type to connect Copper wire on Earth terminal and DB is included in quoted rates. (c) If the test results are not satisfactory the earthing shall be re done at no extra cost.
S&F in replacement of single phase Kwh meter with LCD display, class I, base mounting of rating 10-60 Amps, AC 240 Volt, 50 HZ, with acrylic box including mounting on wooden box of suitable size and making incoming and outgoing electric connection complete all as specified and directed.
S&F in replacement of Three phase Kwh meter with LCD display, class I, base mounting of rating 10-60 Amps, AC 415 Volt, 50 HZ, with acrylic box including mounting on wooden box of suitable size and making incoming and outgoing electric connection complete all as specified and directed. Note for item Nos 55 & 56. The UNSV Kwh meters shall be deposited in E/M store.
S&F in replacement wall mounted Bus-bar chamber factory made out door type made out of 3mm thick CRCA sheet with 250 Amps rated insulated bus bar TPN system & with provision for 04 Nos outgoing complete complete all as specified and directed.
Labour only for attending day to day electric complaints of internal electrification and repairing in situ by skilled electrician along with a helper and rectifying the faulty points/ replacing defective items (Switch, Socket, MCB, Tubelight, holder, capacitor, regulator, bell, fan replacement, light etc) complete all as specified and directed. Note: (a) The trademan should carry all Tools and safety equipments to carry out complaint. Any accident/mis-happening occur will be the responsibility of contractor. (b) The store used in rectifying the complaint will be measured under 'supply only' items on the same BOQ. (c) Trademen shall report the concern complaint Cell at 0900 hrs. (d) Each replacement of defective electric point will be considered as one Complaint. (e) Penality for non attending complaint up to 12 hours shall be charged at the rate of Rs. 100/- per complaint.
Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 9" X 11" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed.
Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 8" X 5" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed. Note: S&F of switches, sockets & regulators shall be measured and paid separately.
Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 5" X 5" including necessary cutting and drilling holes for fixing of switches,sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed Note: S&F of switches, sockets & regulators shall be measured and paid separately.
Taking down existing unserviceable service cable of any description and Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated multi-stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 16 sq. mm nominal cross section, 4 core in service connections as per IS 7098 (Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
Taking down existing unserviceable service cable of any description and Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated multi-stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 25 sq. mm nominal cross section, 4 core in service connections as per IS 7098 (Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 63mm, inner dia 50mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of pipes / cable and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed.
Removing surplus spoil to a distance not exceeding 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as specified and directed.
Supply and fix in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor twin core, 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections including connecting on LT OH line / energy meter / DB etc complete all as specified and directed.
All as per serial item No. 68.00 above but size twin core 6 sqmm complete all as specified and directed.
All as per serial item No. 68.00 above but size twin core 4 sqmm complete all as specified and directed.
S&F Exhaust fan Steel body AC single phase 230/240 Volt of size 300 mm sweep complete with louvers including making whole on wall to fix exhaust fan and grouting of nut bolts etc and making good the disturbed sufaces of wall complete all as specified and directed.
Supply and fixing meter protection board made up of 18mm thick prelaminated Particle board box type with four sides & front double door hanged with continuous piano hinges suitable alongwith hasp and staples for locking arrangment including suitable angle frame fixed to wall suitable for single phase energy meter complete all as specified and directed.
Supply and fixing meter protection board made up of 18mm thick prelaminated Particle board box type with four sides & front double door hanged with continuous piano hinges suitable alongwith hasp and staples for locking arrangment including suitable angle frame fixed to wall suitable for three phase energy meter complete all as specified and directed.
Supply only Retrofit T8 LED tube rod Polycarbonate 4 feet long 20 Watt, single end, 240 volt Single/double side connection as per direction of Eng-in-Charge complete all as specified and directed.
Supply only switch piano flush type polycarbonate single pole one way 5 Amps. complete all as specified and directed.
Supply only switch piano flush type polycarbonate single pole one way 15 Amps complete all as specified and directed.
Supply only socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed.
Supply only socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as specified and directed.
Supply only bell push flush type 5 Amps complete all as specified and directed.
Supply only Bell electric Ding-ding working on single phase 230 Volts AC Supply complete all as specified and directed.
Supply only Batten / Lamp Holder, B-22 base, PVC body complete all as specified and directed.
Supply only Electronic Fan regulator, socket type, 5 steps working on single phase 230 Volts AC Supply complete all as specified and directed.
Supply only MCB SP 20 Amp, 6KA 'C' Curve
Supply only MCB SP 32 Amp, 6KA 'C' Curve
Supply only MCB SPN 63 Amp, 10KA 'C' Curve
Supply only LED T-5 tube light fitting 20 watts with polycarbonate housing and polycarbonate diffuser with integrated electronic driver complete all as specified and directed.
bharat contrectors
R.D.Builders
PARADISE INFRA POWER COMPANY
anant enterprises
M/S Garhwal Enterprises
NITHYA INFRATECH
M/S ROORKEE ENGINEERING
KRISHANA ELECTRIC WORKS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .