Loading…
Loading…
Tender ID
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
2 Mar 2026, 6:00 pmClosed
The Executive Engineer (O&M), DGVCL Piplod Division Office, Surat.
Tender for dismantling of pole & transformer center, Painting on pole, Transformer earthing and other miscellaneous work under various schemes at Magdalla sub division & any other sub division under Piplod Division
278924
DGVCLDPPL/0507/02/2026 Approved Date: 17-02-2026
Open
Electrical
Works
Surat
1 document required · 1 mandatory
₹1,180
Yes
SURAT@DGVCL
₹10,000
Yes
20 Feb 2026
20 Feb 2026
20 Feb 2026
2 Mar 2026
20 Feb 2026
Name of Work :-Tender for dismantling of pole & transformer center,Painting on pole ,Transformer earthing and other miscellaneous work
under various schemes at Magdalla sub division & any other sub division under Piplod Division.
Sr. No. Item Code Item Unit FY 2024-25
STRINGING OF(30mm2)ACSR/34MM@,55MM2 AAA CONDUCTOR for ALL TYPE OF
1 9926000016 CONDUCTOR (EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING FIXING OF
INSULATORS, BINDING JUMPERING ETC.
2 9926000017 STRINGING OF GI WIRE 8 SWG INCLUDING BINDING JUMPERING ETC. DO
Stringing/LAYING OF OVER HEAD LT CABLE FOR ROAD CROSSING,HT LINE CROSSING AND
TELEPHONE LINE CROSSING ETC.(PER SPAN)
STRINGING OF 100MM2 ACSR/100MM2 AAAC CONDUCTOR FOR 11/22KV & LT LINES ONE COND
INCLUDING FIXING OFINSULATORS, BINDING JUMPERING ETC. PER KM
STRINGING OF DOG CONDUCTOR FOR 11/22KV & HT LINES INCLUDING FIXING OF ONE COND
INSULATORS, BINDING JUMPERING ETC. PER KM
DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITH TRANSFORMER)
8 9926000035 WITH CREDITING OF FABRICATION & TRANSFORMER AT STORE & STACKING OF POLE No.
SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITHOUT TRANSFORMER)
9 9926000036 WITH CREDITING OF FABRICATION AT STORE & STACKING OF POLE SAFELY ON ROAD No.
SIDE OR CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM,
LT SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND TO PROVIDE
SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM INCLUDING FITTING
OF ALL ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
11 9926000038 CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND TO KM
PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM,
BINDING TO PIN INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM,
BINDING TO PIN INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS REQUIRED
AND DIRECTED BY ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM INCLUDING FITTING OF
ALL ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND TO PROVIDE
SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
DISMENTALING OF RSJ (9/11 METER) POLE AND CREDITING THE OLD MATERIAL TO
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC POLE(WITHOUT
16 9926000043 TRANSFORMER) WITH CREDITING OF FABRICATION AT STORE AND STACKING OF POLE No.
SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC POLE(WITH
17 9926000044 TRANSFORMER) WITH CREDITING OF FABRICATION AT STORE AND STACKING OF POLE No.
SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES AND FABRICATION TO DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES AND FABRICATION TO DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM AND CREDITING
FITTING OF ALL ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM AND CREDITING
FITTING OF ALL ACESSARIES TO DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG CONDUCTOR) FOR 11/22KV & ONE COND
LT LINES INCLUDING FIXING OF INSULATORS, BINDING JUMPERING ETC. PER KM
RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES INCLUDING , BINDING ONE COND
JUMPERING ETC. PER KM
Binding of messanger Conductorat with a distance not more than 0.75 mtr with 6 turns
minimum on XLPE Cable with single strand binding wire (including cost of binding wire)
Supply and Installation of 11/22 kV Distribution Transformers HT Terminal protector (UV
26 9926000086 Resistance) with using 95/120/150 sq.mm long barrel aluminum lug. (1Set = 3 Nos i.e. on PER SET
Supply & Installation of HT EPR Tap on 11/22 kV Distribution Transformer with
replacement of bare conductor by HT ABC conductor (DO bottom side to transformer)
after removal of semi conductor by HT ABC (6 inch both side). HT ABC to be supplied by
DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and Commissioning of Maintenance Free, Ready Capsule,
Pipe-In-Cage (Pic) Type, Earth Electrodes for HT Feeder Pole Having 2000 mm Electrode
Length as per the Tender Specifications and Drawing. (All Materials Will Be Supplied By
Supply, Installation, Testing and Commissioning of Maintenance Free, Ready Capsule,
Pipe-In-Cage (Pic) Type, Earth Electrodes for HT Feeder Pole Having 3000 mm Electrode
Length as per the Tender Specifications And Drawing. (All Materials Will Be Supplied By
Supply and Installation of 25 X 3 mm GI Strip having hot dip- galvanized-zinc coating of 80-
100 microns without any joints or welding. Both the end of the GI strip should be
connected with GI nut bolts and required fabrication work for giving separate earthing
30 9926000090 (1) Neutral of the transformer Meter
(2) MS structures of the transformer center (Approximately 25 meter GI strip per
transformer centre
- as per requirement and instruction of Engineer in- charge) (All Materials will be
supplied by Agency)
Supply and Installation of uPVC standard make Pipe of 1.25" diameter for covering GI
strip with UV protected Cable Ties of 550 X 7.6 mm size to bind with pole
face(Approximately 25 meter uPVC pipe for GI strip covering per transformer centre -as
per requirement and instruction of Engineer in-charge.
Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Drop out Fuse and Drop out
32 9926000093 fuse to Transformer H.T. including Busbar (12 mm sleeve) as per technical specification. Per TC
(All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Drop out Fuse and Drop out
33 9926000100 fuse to Transformer H.T. without Busbar (12 mm sleeve) as per technical specification. (All Per TC
Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleev for Bus bar to Drop out Fuse and Drop out
34 9926000094 fuse to Transformer H.T.including Busba r(15mmsleev) as per technical specification. (All Per TC
Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Drop out Fuse and Drop out
35 9926000101 fuse to Transformer H.T. without Busbar(15 mm sleeve) as per technical specification. (All Per TC
Materials will be supplied by Agency)
Supply & fixing of Disc type Red Color FRP(Non-flammable) material with Weather
36 9926000095 resistant, Non-conductive bird guard OD=300 MM, ID=33 MM, Width =1.25 MM, one NO
side cut from ID to OD. (All Materials will be supplied by Agency)
Providing and fixing of LT Terminal protectors i.e. Re-useable boot (LT Side 1.1 Kv)
37 9926000096 including LT (1.1 kV) insulating taps. All live part at LT side shall be covered with fixing NO
of LT insulating taps.
38 Nylon Net around Transformer Center
38.1 9926000097 Nylon Net (12 * 15 ft) Per Net
38.2 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated material for fitting nylon net shall be
provided by DGVCL)
39 9924000001 Cutting of Tree branches surounding HT/LT line Per Tree
Replacement of old jumpers & providing new double jumpers with 8" binding [D Type] &
capsuling with PVC pipe etc
41 9924000005 Support pole for Stay PSC/STP/RSJ No.
42 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
43 9924000007 Pin binding of conductor 11/22kv Pin insulator per pole in costle area with cleaning . No.
44 9924000008 Pin binding of conductor LT shakel insulator No.
45 9924000009 Replacement of one/both disc.insulator at strain pole No.
46 9924000010 Replacement of LT shackle insulator at cut point No.
47 9924000011 Refixing of V cross Arm No.
48 9924000012 Replacement of V cross Arm (With Transportation & Painting) No.
49 9924000013 Refixing of Top fitting in proper position No.
50 9924000014 Replacement of Top fitting No.
51 9924000015 Replacement of LT cross Arm No.
52 9924000016 Providing DO fuse on DP with carting & jumpuring(ONE DO FUSE) No.
Numburing of pole with paint by preparing back ground of one colour and have
lettering(height 3" * width 0.5") using stensil
54 9924000018 Fixing of MMB(1PH.) at consumer end No.
55 9924000019 Fixing of MMB(3PH.) at consumer end No.
56 9924000020 Replacement of (1ph.) meter for Urban area No.
57 9924000021 Replacement of (1ph.) meter for Rural area No.
58 9924000022 painting consumer no. on MMB (Urban) (with letter size height 40mm* width 8mm) No.
59 9924000023 painting consumer no. on MMB (Rural) (with letter size height 40mm* width 8mm) No.
60 9924000024 Replacement of deteriorated Single phase Service line No.
61 9924000025 Fixing of new dist. Box with complete wiring including clamps,nut bolts etc. No.
62 9924000026 Reparing of guarding involving reshaping of bearer wire cross lacing binding etc. R Mtr.
63 9924000027 Painting of steel fabricated material of RSJ DO DP structure with paint No.
Painting of steel fabricated material of RSJ pole mounted transformer double pole
structure with paint
65 9924000029 Painting of steel fabricated material of RSJ single pole with paint No.
66 9924000030 painting of steel fabricated material of PSC Single pole (HT line) with paint No.
67 9924000031 painting of steel fabricated material of PSC DO DP double pole with paint No.
painting of steel fabricated material of PSC double pole at pole mounted transformer
69 9924000033 Providing line seperater single phase No.
70 9924000034 Providing line seperater three phase No.
71 9924000035 Replacement / Providing of stay insulator along with adjustment of tension in stay wire No.
Replacement of deteriorated /providing LT dist. Box with new up to 100KVA capacity &
crediting it to store.
Replacement of deteriorated /providing LT dist. Box with new above 100KVA capacity &
crediting it to store.
74 9924000038 Adjustment of tension in stay wire No.
75 9924000039 Refitting of LA No.
76 9924000040 Converting pin point to Shackle point including dismentaling & restringing etc. location
77 9924000041 replacement of 11KV Pin insulator with providing new double pin binding No.
replacement of 22KV Pin insulator by new 11kv pin insulator with spares & providing new
double pin binding
79 9924000043 Providing 11kv double disc insulators with binding & restringing No.
80 9924000045 Replacement of existing 11kv conductor (all size) with new double pin binding Cond/KM
81 9924000046 Plumbing of PSC Pole with straightening at pin point No.
82 9924000047 Plumbing of PSC Pole with straightening at tension point No.
83 9924000048 Plumbing of tilted DP structure (PSC/RSJ/STP) with refilling of stone Murrum etc. No.
Providing new 11kv AB /GO switch with fabrication and insulated colour code jumper,
binding, lugs etc
Replacement of old 11kv AB /GO switch with providing new insulated jumper, binding,
86 9924000052 Providing cage type loop guard in verticle LT line with using PVC reel insulators etc per pole
Labour charges for replacement /providing of MMB & service with all accessories for
three phase connection
Labour charges for replacement /providing of MMB & service with all accessories for
single phase connection
Dismentalling of existing Dist.X'mer center(RSJ /STP POLE) 25/63/100/200 KVA with all
fabrication & creditig the old material to store
Disconnection from LT pole 1 phase
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
Disconnection from LT pole 3 phase
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
94 9924000060 Dismentaling & removing of service line from pole & crediting to S/dn (1 ph.) No.
95 9924000061 Dismentaling & removing of service line from pole & crediting to S/dn (3 ph.) No.
96 9924000062 Reconnection of service line complete with PVC cable (1 Ph) No.
97 9924000063 Reconnection of service line complete with PVC cable (3 Ph) No.
Providing spiral type earthing by G.I. NO 8(weight 2kg -5mtr in length) with salt and coal
98 9924000064 10kg each, including pvc rigid pipe 20mm dia( 1.5mtr length) to pass exposed part of G.I. No.
wire at consumer end with all materials, earth resistance should be less than 2 ohms
Providing and fixing of signle core 1.5 sq mm single strand copper insulated cable with
cable nail clip for spiral type earthing at consumer end. The end of G.I. no 8 is to be
connected by connector with copper cable of which other end shall be connected to the
99 9924000070 per meter
earth terminal of meter box. This item shall be used in location where there is more
distance between earth terminal and earthing terminal of meter. (All materials supplied
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp, fixing of cross arm, LT shackle insulator etc.
for fixing of messenger wire and inclusive of dismantling charge of existing bare
100 9924000065 conductor and crediting in to store & dismentaling of service line from LT bare conductor KM
and to provide service connection on Aerial Bunch Cable by insulated pierceing
connectors through service connection box complete as required & directed by Engineer
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM including fitting of all
acessaries i.e. special design suspension / tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and inclusive of dismantling charge of existing
101 9924000066 bare conductor and crediting in to store & dismentaling of service line from LT bare KM
conductor and to provide service connection on Aerial Bunch Cable by insulated
pierceing connectors through service connection box complete as required & directed by
Engineer in Charge.
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp, fixing of cross arm, binding to pin
102 9924000067 insulator,preparing shackle point,jumpers etc. and inclusive of dismantling charge of KM
existing bare conductor and crediting in to store complete as required & directed by
Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp, fixing of cross arm, binding to pin
103 9924000068 insulator,preparing shackle point,jumpers etc. and inclusive of dismantling charge of KM
existing bare conductor and crediting in to store complete as required & directed by
Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM including fitting of all
acessaries i.e. special design suspension / tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and inclusive of dismantling charge of existing
104 9924000069 bare conductor and crediting in to store & dismentaling of service line from LT bare KM
conductor and to provide service connection on Aerial Bunch Cable by insulated
pierceing connectors through service connection box complete as required & directed by
Engineer in Charge.
Labour charge for excavation of 2100mm long x 1200mm wide x 1200 mm deep
joint pits for installation of 11kV / 22kV Straight through joints as per instruction
105 9925000023 of engineer-in-charge & covering the cable with 150 mm dia (Outer), thickness No.
25 mm, 1.0 meter long RCC half round muffs & refilling same as per instruction
Providing and fixing of insulating bus bar, made from 11KV/22KV XLPE cable
after removal of semi conducting layer and applying of PVC heat shrinkable anti-
tracking core insulating tubing (1.1KV), on both end terminal using Aluminium
long barrel heavy duty up to 300 sq mm lugs, Aluminium bus connector. Taping
with PG- clamp for bus conductor as per drawing and as per instruction of EIC.
The Alluminium lugs and PG clamp shall be covered with 11KV/22KV HT
insulating tapes.(11KV/22KV XLPE cable will be in scope of DGVCL while all other
materials will be in bidder's scope)
Testing of cable at various points and commissioning the feeder as per
107 9925000025 instruction of engineer-in-charge.Test result shall be submitted by contractor No.
Preparation and submission of 6 (six) copies, of complete layout drawings with
108 9925000026 GIS mapping as per actual cable routing showing road crossing, HDPE pipe Set
sleeving, jointing locations, markers etc.
Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm (W) from 3 mm
aluminium sheet along with 1.0 mm dia aluminium binding wire for fixing of
aluminium tag near end termination joint at DP structure for identifyng the
cable. The details of feeder i.e. 11 / 22 KV with feeder name shound be punched
on the tag by letter punch of size 16 mm as per instruction of In-charge
Modifications e.g.Providing and fixing of Terminal protectors i.e. Re-use able boot (HT
Side 11/22KV, LT Side 1.1KV) including 11/22 KV insulating taps and L.T.(1.1 KV) insulating
taps ,Busbar, Tapping from Bus Bar (11/22 KV XLPE cable) through P.G. Clamp for H.T.
Jumper to D.O. Fuse to bushings of Transformer Center, providing & Fixing of jumper
and providing & fixing of Heat Shrinkable Anti Tracking Core Insulating Tubing (Insulation
110 9925000046 Level 11/22 KV) in H.T. jumper , Clamping arrangement of cable support frame on both No.
side of existing Over Head type Distribution Transformer to utilize in Under Ground cable
network as per drawing & as per instruction of Engineer incharge. All live parts i.e. PG-
Clamp, connections of D.O.fuses, HT bushings etc . shall be covered with fixinng of 11/22
KV HT insulating tapes. ( 11/22 KV XLPE cable will be in scope of DGVCL while all other
materials will be in bidder's scope ) .
111 9925000047 Laying of any size of 11/ 22 KV XLPE /PILC Cable in redaymade trench or in open space
112 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
113 9925000064 Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC half round pipe No.
114 Dismental OF 100MM2 AAAC CONDUCTOR KM
115 Supply and fixing of Suspenssion clamp to Hold the cable (J-Hook) NO
Model:ETP/HDR/17/2
115.1 Terminal Size: 25mmX 6mm Length: 2 Mtr NO
With clamp & 2 no’sof M10 size SS nut & terminal to T/C neutral separately
using Bolts with connection of earthling 25X 3mm Hot Dip GI strip(per
Transformer/ Earthling 04 Mtr GI patti)Installation of Earthling PIT ,work
includes supply and
labour for connectionall respect.
Ground Conductivity
Improve Material,
115.2 Hydrolyte Net NO
Providing and fixing Green HDPE pipe ,size 160 mm Dia X 5 mm thickness X 7 feet height .
116 & GI clamp size 25 X 3 mm (1 Round clamp & 2 Nos C -type Clamp with GI bolts – nuts (10 NO
nos.) Danger sign sticker with toll free number of DGVCL embossed
1.DGVCL will provide key material like M.S. materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated
materials etc. to the contractor.
2.All fabricated items shall be fabricated as per DGVCL approved drawing and by welding
rods confirming to the relevent ISI specification and as directed by Engineer in charge.
3.Necessary electricity connection for fabrication items shall be provided by DGVCL on
payment of required charge for connection & electricity bill of the same shall be paid by
4.All the rates are inclusive of PF & Exclusive of GST applicable time to time.
5.All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before applying the paints on to the RSJ poles &
steel fabricated materials of RSJ/PSC poles is must required.
(b) Two coats of approved ISI mark red oxide (primer) is to be properly painted for the RSJ
poles & steel fabricated materials of RSJ/PSC poles.
(c) Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent quality
silver paint) is to be properly painted on to the RSJ poles & steel fabricated materials of
6.BidderwillhavetoprovideastickeronHDPEPIPEatcablerisinglocationdescribingrouteofcabl
easperinstructionofEngineerIn-charge. 10,00,000/-
IN WORDS ( Ten lakhs rupees)
Piplod Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
OH DISMENTAL.pdf
tender description OH.pdf
SCHEDULE B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .