| 1 | L1₹1.3 CrAccepted-AOC HPSEBL THALOUT | ₹1.3 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.5 CrRejected-Finance VILLAGE BASTI KOHALA P O ADHE DI HATTI TEHSIL JAWALAMUKHI DISTRICT KANGRA H P | KANGRA | HIMACHAL PRADESH | 176001 | ₹1.5 Cr | L2 | Rejected-Finance Rejected |
| 3 | L3₹1.5 CrRejected-Finance ANDHRA POWER HOUSE DIVISION HPSEBL CHIRGAON 171208 | SHIMLA | HIMACHAL PRADESH | 171208 | ₹1.5 Cr | L3 | Rejected-Finance Rejected |
| 4 | L4₹1.5 CrRejected-Finance NOT AVAILABLE | NA | NA | 121004 | ₹1.5 Cr | L4 | Rejected-Finance Rejected |
Tender Value
₹1.8 Cr
EMD Value
₹3.5 L
Closing Date
20 Mar 2026, 5:00 pmClosed
EE HIMUDA DIVISION GHUMARWIN
EE HIMUDA DIVISION GHUMARWIN
Civil Hospital Complex Ghumarwin District Bilaspur HP SH Construction of Car Parking and Commercial Complex including internal EI work
2026_HIMUD_131202_1
E-17-2026
Open Tender
Civil Works
270 days
Ghumarwin
Please refer tender documents
9 documents required · 9 mandatory
₹5,900
₹3.5 L
30 Apr 2026
11 Mar 2026
23 Mar 2026
12 Mar 2026
20 Mar 2026
12 Mar 2026
Cutting in earth work through mechanical/ manual means in all heights/depth and all kinds of soil such as kankar, moorum, shingle and decomposed of soft rock, or hard rock i.e. their intermediate classification and chiseling /wedging out of rock where blasting prohibited including saturated soil and filling in embankments etc. where necessary and disposal of excavated unserviceable material through mechanical transpotation in all leads and lifts, nothing extra on this account including carriage and disposal of surplus earth will not be paid up to any extent/reason what so ever. Any damage to private/public property during excavation will be restored by the contractor whatever the nature of the same may be. The serviceable material will be stacked in specified dimensions in all leads and lifts as per the direction of the Engineer-in- charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in all kind of soil in foundation trenches or drains up to all width/depth and stacking the excavated soil not more then 3 metres clear from the edge of excavation and then returning the stacked soil in 15 cm layers when required in to plinth sides of foundation etc., consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth in all leads and lifts as per the direction of the Engineer-in- charge.
Centering and shuttering including strutting, propping etc. and removal of form for all height including carriage of material in all leads and lifts.
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform
Stairs, (excluding landings) except spiral-staircases
Edges of slabs and breaks in floors and walls Under 20 cm wide
Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
Stone soling properly handpacked filling interstices with spalls and consolidating with hand ramming to therequired level including spreading watering and ramming etc. complete as per HP.PWD specification. 100 mm spread thickness (finished work including materials and labour) including carriage of material in all leads and lifts.
Providing and laying in position cement concrete of 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering - All work up to plinth level including carriage of material in all leads and lifts.
Providing and laying in position cement concrete of 1:3:6 (1 Cement : 3 coarse sand): 6 graded stone aggregate 40 mm nominal size)e excluding the cost of centering and shuttering including carriage of material in all leads and lifts.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. including carriage of material in all leads and lifts.
All works upto plinth level
All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level including carriage of material in all leads and lifts. (a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level including carriage of material in all leads and lifts. (a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). including carriage of material in all leads and lifts.
Providing and fixing three track factory made uPVC white colour casement/ casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion, sliding sash super sash profile 160, glazing 5 mm thick toughened glass stain less steel mesh grade-304, white handles including fasteners, weather proof silicon sealant stainless steel screws etc. complete in all respect as directed by Engineer-in-Charge including carriage of material in all leads and lifts.
Supplying and fixing rolling shutters 80x1.25 mm M.S. laths with 1.25 mm thick top cover of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. including carriage of material in all leads and lifts.
Providing and fixing ball bearing for rolling shutters including carriage of material in all leads and lifts.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). including carriage of material in all leads and lifts.
Providing and laying vitrified floor tiles as per sample approved by the Engineer-in- Charge in different sizes (thickness not less then 10 mm) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete including carriage of material in all leads and lifts.
Providing and laying Vitrified tiles as per sample approved by the Engineer-in- Charge in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. including carriage of material in all leads and lifts.
Providing and laying Polished Granite stone flooring as per sample approved by the Engineer-in- Charge in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. including carriage of material in all leads and lifts.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.62 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. including carriage of material in all leads and lifts.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. including carriage of material in all leads and lifts.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. including carriage of material in all leads and lifts. (a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand) including carriage of material in all leads and lifts.
15 mm cement plaster on rough side of single or half brick wall of mix 1:6 (1 cement: 6 coarse sand) including carriage of material in all leads and lifts.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. including carriage of material in all leads and lifts.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade new work (two or more coats) over and including water thinnable priming coat with cement primer including carriage of material in all leads and lifts.
Wall painting two or more coats with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. including carriage of material in all leads and lifts.
Providing and laying 80 mm thick factory made chamfered edge Cement Concrete paver blocks of M-30 grade with approved color design and pattern in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. including carriage of material in all leads and lifts.
Providing and laying heavy duty anti skid veterified tile (Barberino lux or equivalent approved make) as per sample approved by the Engineer-in- Charge in different sizes (thickness not less then 12 mm) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 25mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including cutting, jointing with matching cement slurry, cleaning and curing complete in all respects as per direction of Engineer-in-Charge. including carriage of material in all leads and lifts.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth including carriage of material in all leads and lifts.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed Steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. (A) Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed medium class PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required and approved by the Engineer-in -Charge.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed pvc conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. and approved by the Engineer-in -Charge.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed pvc conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required and approved by the Engineer-in -Charge.
2x1.5 Sq. mm.
2x 6 Sq. mm..
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required and approved by the Engineer-in -Charge. (a) 3*1.5 sqmm
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required and approved by the Engineer-in -Charge.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required and approved by the Engineer-in -Charge.
Supplying and fixing 3 pin Ceiling rose on the existing junction box /wooden block including connections etc as required and approved by engineer in charge.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required and approved by engineer in charge.
Double door-8 way
Double door-12 way
Supplying and fixing of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required and approved by engineer in charge. (a) Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required and approved by engineer in charge. (a) 40 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required and approved by engineer in charge. (a) 40 Amps. Cat-A
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation, made from 1.6 mm thick M.S. sheet duly fabricated in a segregated manner for housing of switch fuse units, by welding each compartment on five sides & front side hinged, complete with locking arrangement, with sufficient No. vertical and horizontal intermediate switchgear housing compartments. The cubical pedestal shall have cable entry box at one or two sides, with epoxy powder coated approved paint and bonding to the existing earth etc. The same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form 300 mm deep (nominal) as direction by engineer in charge.
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required and approved by engineer in charge. (a) 100 A 16KA FP
Supplying and fixing copper strip bus-bars, suitable for100 Amp. 415 volts capacity 4 No. each of cross-sectional area (25.4mmx3.17mm), in the existing enclosure or cubical panel with all accessories including connections etc. as required and approved by Engineer in charge.
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but with charcoal or coke and salt ) complete as required and approved by engineer in charge.
Supplying and laying 6SWG GI wire 4 mm on surface or in recess for loop earthing as required and approved by engineer in charge.
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required and approved by engineer in charge. (a) Armoured cable 25sq. mm (3.5 core)
Providing, Installation, testing and commissioning of ceiling fan with regulator and fan box, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required and approved by engineer in charge. (a) Ceiling Fan 1200 mm
Providing and installation of following type of LED batten LUMILINEPLUS Smart Batten with Microwave Motion Technology LUMILINESMART 20W LED865PCSSG2 with aluminium housing, anti glare polycarbonate diffuser and energy efficient constant current, integral electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including mounting clamps, connections, testing etc. as required and approved by engineer in charge. (a) LED Smart Batten Light 20W
Providing and installation of surface/recess mounted commercial luminaire with Aluminium housing product codeINTEGRA NXT SQ DL RSURD 9W LED Surface 24W suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing etc. as required: of Havells and Equivalent Make INTEGRA NXT DL SQUARE - SURFACE 24 Watt..
Supplying and fixing of LED street light 30 watt made up of pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass having bottom opening seprate driver with IP 66 protection and impect resistance of IK07 code ENDURA SUNDOW NSL30 W LED757PASYBOPC complete with all accessories( G.I bracket of suitable size a/w Clamps & nut bolts ), including mounting clamps, connections, testing etc of Havells or equivalent make as requird and approved by the Engineer-in-charge.
Providing and installation of PDC Housing LED Bulkhead Luminaire with opal diffuser with ip65 protection rating product code BIBWP 10W LED complete with all accessories, connections, testing etc. as required: of Bajaj and Equivalent Make and approved by the Engineer-in-charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
Condition.pdf
Additional Documents • 6.94 MB
TenderForm.pdf
Tender Documents • 1.29 MB
BOQ_193989.xls
BOQ • 0.41 MB
UNDERTAKING.pdf
Additional Documents • 0.25 MB
Download all tender documents and submit your bid