Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.0 L+₹1.0 L (13.1%)Rejected-Finance | L2 | Rejected-Finance SINCE NOT L1 |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
24 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I FY Eddumailaram
AGE I FY Ordnance Factory Eddumailaram 502205
REPAIR MAINT RE ROUTING OF UG CABLES AND OVER HEAD LINES AT CQA ICV AND MES UNDER AGE I FY EDDUMAILARAM
2020_MES_370568_2
8249
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Eddumailaram
Class E
Category b i
5 documents required · 5 mandatory
₹500
Yes
AGE I FY
₹19,000
Yes
18 Feb 2021
3 Oct 2020
26 Oct 2020
3 Oct 2020
24 Oct 2020
10 Oct 2020
60 days
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles &stay etc complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge
M&L for Sand filling in trenches using dry river sand as cushioning to under ground cable including spreading, levelling and consolidation complete all as specified and directed. [Note: Punned thickness of sand shall only be measured.]
Supply and laying reinforced precast concrete cable cover ,class LV type I,flat,size250x150x40 mm.
Supplying and laying unreinforced precast concrete cable cover, class HV, Type-1, flat, size 300mmx180mmx40mm laid alonh alignment of cable as protection to cable in trenches complete all as specified and as directed.
Re laying sub class 'B' bricks of old size 230mm x 110mm x 75mm for cable protection laid across alignment of cable in trenches retrived vide Item No. 1 above complete all as specified and directed.
Taking out old unserviceable LT/HT under ground cable any type from trenches,pipes & poles complete
Relaying of old serviceable LT cables as obtained from item No. 8 above
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 3.5 core 240 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / road crossing / fixed on poles / walls including taking out old cable complete all as specified and directed by the Engineer-in-Charge. [Make: CCI / UNIVERSAL / NICCO / POLYCAB / ASIAN / FORT GLOSTER / FINOLEX]
All as per Item No. 10 above but 70 sqmm 3.5 core
All as per Item No. 10 above but 95 sqmm 3.5 core
All as per Item No. 10 above but 120 sqmm 3.5 core
Supply and Laying HT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 3 core 95 Sqmm, 11000 volts grade, earthed system with multistranded aluminium conductor laid in trenches / passing through pipe / duct / road crossing / fixed on poles / walls including taking out old unserviceable cable complete all as specified and directed by the Engineer-in-Charge. [Make: CCI / UNIVERSAL / NICCO / POLYCAB / ASIAN / FORT GLOSTER / FINOLEX]
Supply & jointing heat shrinkable straight through joint suitable for LT 1100 Volt grade XLPE cable of size 185-300 Sq mm 3.5 core complete with treating of cable to make ready for jointing all as specified and as directed. Make : ISI marked
All as per item No. 15 here in before but suitable for cable size 50-120 sq mm.
Supply and laying cable joint kit for 11KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories material for 3core XLPE armoured aluminium conductor cable of size 95 sqmm in trenches /passing through pipes etc complete all as spacified and directed. Make: Birla 3M/Denson/ Raychem
Supply and laying cable joint kit for 11KV (earthed) grade cable for out door end termination heat shrink type joint complete with jointing material and accessories material for 3core XLPE armoured aluminium conductor cable of size 95 sqmm in trenches /passing through pipes etc complete all as spacified and directed. Make: Birla 3M/Denson/ Raychem
Supply and laying GI tubing 100mm bore, light grade laid in trenches / road crossings for cable protection complete all as specified. [Make: TATA / JINDAL / SURYA ROSHINI / PRAKASH]
Supply and laying GI tubing 80mm bore, light grade laid in trenches / road crossings for cable protection complete all as specified. [Make: TATA / JINDAL / SURYA ROSHINI / PRAKASH]
Supply and laying GI tubing 50mm bore, light grade laid in trenches / road crossings for cable protection complete all as specified. [Make: TATA / JINDAL / SURYA ROSHINI / PRAKASH]
Taking down and dismantling cross arms bracing supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, any shape or size as indicated or directed by Engr-in-Charge
Dismantling insulators any type ,any size complete all as specified and as directed by Engineer in charge
Dismanting earth wire /guard wire conductor or ,service feeder or distbutor span complete all as specified and as directed by Engineer-in-charge.
Dismantling ACSR conductor complete all as specified and as directed by Engineer-in -charge.
Supply, fabricate and fixing of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including two coats of aluminium painting over a coat of primer complete all as specified and directed by Engineer-in-Charge.
Straightening and Stringing only of aluminum conductor steel reinforced (ACSR) conductor upto 3 to 6 wire on existing pole and binding with the new aluminium wire binding wire 2 mm dia (the new ACSR conductor to be measured and paid separately) conductor as per site requirement all as specified and as directed by Engr-in-Charge.
Material and Labour for ACSR conductor of any size and type including binding wire jointing sleeves for over head lines securing on poles complete all as directed by the Engineer-in-charge.
M&L galvanised steel wire 4 mm dia for earth or guard wire complete all as specified and as directed by Engineer-in -charge.
M&L in replacement of pin type, porcelain, vitreous, brown insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed by Engr-in-charge
M&L shackle type, porcelain, vitreous, brown, 75 mm in height and 90 mm maximum dia for 1100 volts grade working pressure insulator including galvanized mild steel straps, washers, insulators bolts, washers and nuts complete all as specified and directed by Engr-in-charge
M&L loop type insulator ,vitreous porcelain white ,brown or green of size 65x90mm complete all as specified and as directed by Engineer -in-charge
M &L in replacement of lugs/thimbles at termination of LT cable by cutting the end portion and removing insulation and fixing new aluminium lugs /thimble properly with crimping tool of size 70-120 sq mm complete.
All as per srl item No. 33 here in before but for cable size 25-50 sq mm .
Trimming / cutting of tree branches upto 1.0m on either side of OH lines in the area of LT OH lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of tree) and removal of the trimmed branches of trees and depositing the same in ODF FY waste bins inside the campus complete all as specified and directed by Engr-in-charge.
M&L for Preparing existing old surface of steel tubular poles of any type 09 Mtr long for painting one coat of aluminium paint on the surface of steel tubular/PCC pole and channels/coss arms complete all as specified and as directed by Engineer-in-Charge.
M & L for painting to PCC/steel poles of any type and any size including channels/cross arms with two coat of synthetic enamel paint and marking the pole No in 4” dia and substn no. yellow paint circle complete all as specified and directed by Engr-in-Charge.
M&L for augering of holes in true horizontal position under road /pavement by means of mechanical rig after doing ultrasound technique to prevent any damage to existing cables/pipe lines coming in route 1.5 Mtr deep and not exceeding 50 Mtrs long including laying HDPE pipe of 150mm dia complete.
Supply and fix MCCB 400 Amps 4 pole 50 KA 415 Volts 50 Hz with thermal adjustable magnetic settings including taking out old existing unserviceable MCCB from panels etc complete all as directed. Make :Indo asian/Havells / Legrand/ Schnieder/Seimens
All as per srl item No. 39 here in before but 250 Amps 4 pole 36KA
All as per srl item No. 39 here in before but 200 Amps 4 pole 36 KA
All as per srl item No. 39 here in before but 160 Amps 4 pole 36 KA
All as per srl item No. 39 here in before but 100 Amps 4 pole 25 KA
M&L for defect rectification LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 300 Sq mm 3.5 core. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge
M&L for PCC (1:3:6) type C1 using 20 mm graded stone aggregate for making coping of LT poles as specified and directed by Engr-in-Charge .
M&L for earthing in replacement of with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
NIKESH ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .