Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.0 LAccepted-AOC | ₹2.0 L | 1 | Accepted-AOC L1 |
| 2 | 2₹2.1 LRejected-AOC | ₹2.1 L | 2 | Rejected-AOC L2 |
| 3 | 3₹2.1 LRejected-AOC | ₹2.1 L | 3 | Rejected-AOC L3 |
| 4 | 4₹2.1 LRejected-AOC | ₹2.1 L | 4 | Rejected-AOC L4 |
Tender Value
₹2.7 L
EMD Value
₹6,753
Closing Date
27 Feb 2026, 11:00 amClosed
ASSISTANT EXECUTIVE ENGINEER
PH SUBDIVISION KWA KOLLAM
DEPOSIT PROVIDING AND LAYING PIPELINE ITHIKKARA BLOCK PANCHAYATH Laying Pipeline and Providing water connection at Kavanappally Sanketham at Chathannnoor Panchayath Pipeline Work
2026_KWA_837681_1
TR/27852/2025_26_1_1/1
Open Tender
Civil Works - Water Works
60 days
CHATHANNOOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹600
₹6,753
8 Apr 2026
19 Feb 2026
28 Feb 2026
19 Feb 2026
27 Feb 2026
19 Feb 2026
1. WORKING CHARGES
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.5:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 50 mm nominal outside diameter pipes.
OD197665/2025-2026:Interconnection work in existing 75 mm PVC pipe lines with 50 mm PVC pipe using suitable type of specials as per the direction of Engineer in charge.
100.60.1.3.2:Providing 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
100.60.10.5.1:Providing 25mm (3/4 inch) PVC Air Valve in the water meter assembly for 20mm connection, using 25mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers.
100.60.12.4.1:Providing 15mm PVC Tap in the water meter assembly for 20mm connection, using 25mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
OD198215/2025-2026:Charges of water connection, application and inside installation ( fees to be remitting through E- tapp)
2. COST OF MATERIAL
100.98.210:Supply of PVC Pipe, 6kg/cm2, 50mm Dia.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_1410853.pdf
finsummary_1410853.pdf
aoc.pdf
finance_1410853.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.04 MB
generalconditions.pdf
Additional Documents • 0.11 MB
NIT.pdf
Tender Documents • 0.34 MB
BOQ_1410853.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid