Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹20.2 LAccepted-AOC | L 1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L 2₹21.1 L+₹9,267 (0.44%)Rejected-Finance MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | L 2 | Rejected-Finance Rejected being not lowest |
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
10 Dec 2020, 6:00 pmClosed
GE (NW) KOCHI
GARRISON ENGINEER (NW), KATARIBAGH, NAVAL BASE POST, KOCHI-682004.
MAINT AND REPAIR TO INTERNAL ELECTRIFICATION, FANS AND GEYSERS OF DEFENCE MD ACCN AND COMPREHENSIVE MAINT AND REPAIRS TO FIRE FIGHTING INSTALLATION AND CONNECTED WORKS AT SATELLITE AREA UNDER GE (NW) KOCHI
2020_MES_395063_1
GE(NW)KOCHI/8473/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (NW) KOCHI
₹63,000
Yes
22 Feb 2021
13 Nov 2020
12 Dec 2020
13 Nov 2020
10 Dec 2020
27 Nov 2020
Amount
Taking down copper/aluminium point wiring (ligh, fan, bell, socket or power etc.) complete with all accessories like switches, sockets, regulators, ceiling roses, light fittings etc. for taking credit and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls / floors / ceiling etc all as specified.
M & L for Surface point wiring with 1.5Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable in and including ISI Marked, medium grade, non metallic, Fire Resistant PVC Casing & Capping and all accessories, medium grade PVC surface Box with top cover plate, 1.5Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable as earth continuity conductor and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls / floor / ceiling etc all as specified for One light point controlled by one switch.
All as per item No.2 above, but One ceiling / exhaust fan point controlled by one switch
All as per item No.2 above, One 3 pin socket outlet, 5 Amps controlled by one switch in same board with other switches
All as per item No.2 above, One 3 pin socket outlet, 5Amps controlled by one switch independent
All as per item No.2 above, One bell point controlled by one bell push on same board or independent
All as per item No.2 above but for One 3 pin socket outlet, 15Amps controlled by one switch independent with 2.5 sqmm cable and 2.5Sqmm cable as earth wire on independent board
S & F switch piano flush type, 5A, AC, 240V, one way ISI Marked all as specified.
S & F Bell Push, flush type, 5A, AC, 240V, ISI Marked and as specified.
S & F socket piano flush type, 5A, 5pin, AC, 240V ISI Marked and as specified.
S & F socket piano flush type, 15A, 6pin, AC, 240V ISI Marked and as specified.
S & F Power Unit suitable for AC / Geyser, 20A, 3pin, AC, 240V ISI Marked incl PVC Surface Box all as specified.
S & F Electronic 5 Step Fan Regulator, 240V, AC, 240V, ISI Marked and as specified.
S & F in repairs switch piano flush type, 5A, AC, 240V, one way ISI Marked all as specified.
S & F in repairs switch piano flush type,15A, AC, 240V, one way ISI Marked and as specified.
S & F in repairs Bell Push, Flush type, 5A, AC, 240V, ISI Marked and as specified.
S & F in repairs socket piano flush type, 5A, 5pin, AC, 240V ISI Marked and as specified.
S & F in repairs socket piano flush type, 15A, 6pin, AC, 240V ISI Marked and as specified.
S & F in repairs Power Unit suitable for AC / Geyser, 20A, 3pin, AC, 240V ISI Marked incl PVC Surface Box all as specified.
S & F in repairs Electronic 5 Step Fan Regulator, 240V, AC, 240V, ISI Marked and as specified.
S & F Ceiling rose surface Bakelite 65x50mm, 3 terminals, AC, 240V, ISI Marked and as specified.
S & F Call Bell, AC, 240V, SP, ISI Marked and as specified.
S & F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings, AC, 240V, Pin type, ISI marked and as specified.
S & F Modular Switch, 1 module, 6A, AC, 240V, one way ISI Marked and as specified.
S & F Modular Switch, 1 module, 16A, AC, 240V, one way ISI Marked and as specified.
S & F Modular Bell Push, 1 module, 6A, AC, 240V, ISI Marked and as specified.
S & F Modular Step Fan Regulator, 2 module, 120W, AC, 240V, ISI Marked and as specified.
S & F Modular Socket, 2 module, 6A, 2/3 pin combined, AC, 240V, ISI Marked and as specified.
S & F Modular Socket, 2 module, 6A / 16A, 2/3 pin combined, AC, 240V, ISI Marked and as specified.
M & L for sub main wiring with 2 runs of 4Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable drawn in and including ISI Marked, medium grade, non metallic, Fire Resistant PVC Casing & Capping and all accessories, with 1 run of 4.0Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable as earth continuity wire and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of wallS & Floors/ceiling etc all as specified including taking old wiring. Note:- Three runs of cable and one run of PVC casing and caping shall be measured together as one run of wiring
M & L for sub main wiring with 2 runs of 6 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable drawn in and including ISI Marked, medium grade, non metallic, Fire Resistant PVC Casing & Capping and all accessories, with 1 run of 6.0Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable as earth continuity wire and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of wallS & Floors/ceiling etc all as specified including taking old wiring. Note:- Three runs of cable and one run of PVC casing and caping shall be measured together as one run of wiring.
M&L for sub main wiring with 4 runs of 6 Sqmm PVC insulated copper conductor multistranded cable drawn in and including PVC conduit including two run of 6 Sqmm multi stranded copper conductor cable for earth condinuity wire and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of wallS & Floors/ceiling etc all as specified including taking old wiring. Note :Six runs of 6 sqmm cable and one run of PVC conduit will be measured together as one run of wiring.
M & L for submain wiring with XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 4 core including all fixing arrangement etc including taking down old cable complete all as specified and as directed.Make :- Havells/Poly cab/Standard
S & F in repair Acrylic / Fibre Enclosure, SPN DB, 240V, AC, 2 way, double door with 200Amps rated busbar ISI Marked and as specified.
All as per item no.34 above but 4 way with 200Amps rated busbar.
All as per item no.34 above but 8 way with 200Amps rated busbar.
All as per item no.34 above but TPN DB, vertical mounting, 415V, 4way with 200Amps rated busbar, double door.
S & F in repair MCB SP 6 to 32 A, AC, 240V, 10KA, ISI Marked and as specified.
S & F in repair Isolator DP, 40A, AC, 240V, 10KA, ISI Marked.
S & F in repair Isolator 4P, 63A, AC, 415V, 10KA ISI Marked and as specified.
S & F in repair RCCB / ELCB, double pole, AC, 40A, 30mA, 240V ISI Marked and as specified.
S & F in repair RCCB / ELCB, 4P, AC, 63A, 30mA, 415V ISI Marked and as specified.
S&F energy saving LED bldg security light of 30 Watt environmental friendly made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection min 100 lumens per watt light output,2.5 kv surge protection including suitble GI brackets with clamps, nuts, bolts etc all as specified. Make : Philips/Wipro/Crompton
Supply & fix Regal Batten 1x22W for LED tube lights, both side connection type all as specified and as directed. Make : Havells Cat Part No. Regal batten 8UPT001X22WSSBSWH / Crompton Cat Part No. IGP131LT8-16 / Philips Cat Part No. TMC501P1XTLED22WP3241
Supply and fix in repair, LED Mirror light fitting with 5 to 7 watts, length 1 feet, min 85 lumens per watt light output, 2.5kV surge protection, including suitble GI brackets with clamps, nuts, bolts etc all as specified. Make : Philips/Wipro/Crompton
S&F LED tube rod 1 x 20 Watt, both side connection all as specified and as directed. Make : Havells Cat Part No. Crystal 1213T8DSTL20W LED 865 GLASS / Crompton Cat Part No. LG-T8-20-865-2 / Philips Cat Part No. Essential LED tube 1200mm 20W865T865T81ND-1
S&F in repairs 1x15/16 Watt LED down lighter square / round in shape surface mounted type and connecting to the existing electrical system all as specified and directed. Make Luker Cat Part no. LCL 15NS/ LCL 15NR
Supply and fix in existing holder, 12w LED Bulb with B22 base, clear acrylic diffuser, Self declaring R No, power factor .90, 100 lumens light output. Make :- Philips/Wipro/Crompton
Supply and fix in existing holder, 5w LED Bulb with B22 base, clear acrylic diffuser, Self declaring R No, power factor .90, 85 lumens light output. Make :- Philips/Wipro/Crompton
M & L for rewinding the fans of any make, any model, from a reputed workshop, removing the burnt winding, cleaning slots, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc, replacement of body screws, testing and commissioning on full load for 8 hrs continuous running all as directed for Ceiling Fan 1200mm Sweep.
All as per item No.50 above, but Ceiling Fan 1400mm Sweep
All as per item No.50 above, but Wall Fan 450mm Sweep
All as per item No.50 above, but Exhaust Fan 300mm Sweep
All as per item No.50 above, but Exhaust Fan 450mm Sweep
S & F in repairs, Condensor / Capacitor 2.5 mfd, 240V, AC, suitable for fans all as directed.
All as per item No.55 above, but 4.0 mfd
S & F Ball bearing made out of high carbon steel, equivalent to the original, suitable for any type, any make, any size fans all as directed.
S & F Bush bearing, made out of brass alloy, equivalent to the original, suitable for any type, any make, any size, fan all as directed.
S & F Nickel plated mild steel clamps, Nuts, Bolts, Washers and split pin suitable for ceiling fans any type, any make, any size all as directed.
S & F Down rod, suitably threaded and holed, made out of 15mmdia GI tubes, duly painted, 300mm long, suitable for ceiling fans any type, any make, any size all as directed.
S & F Fan canopy with tightening screw/check nut, made out of PVC, suitable for ceiling fans any type, any make, any size all as directed.
S & F Rubber reel insulator, suitable for ceiling fans any type, any make, any size all as directed.
S & F Fan blades made out of 1.2mm thick Aluminium alloy and MS screws duly balanced & spray painted with White or Brown colour, Set of three, suitable for 1200mm Sweep ceiling fans of any type, any make all as directed.
All as per item No.63 above, but 1400mm Sweep
S & F Fan blades made out of Acrylic / PVC alloy and MS screws duly balance suitable for 450mm wall fans of any type, any make, for the following size all as directed.
S & F Fan blades made out of 1.2mm thick Aluminium alloy and MS screws duly balanced & spray painted with approved colour, suitable for Exhaust fans of 300mm Sweep, any type, any make all as directed.
All as per item No.66 above, but 450mm Sweep
S & F Split pin made out of Nickel plated mild steel with specified temper, suitable for ceiling fans of any type, any make with bolts of any size all as directed.
S & F Bakelite body Nichrome connectors, 2 way with fixing screws of suitable size for ceiling fans of any type, any make all as directed.
S&F energy efficient ceiling fan of 1200mm sweep (5 star rated) 230 Volt 50 Hz including all electrical connection all as specified and as directed.make :- Havells/Crompton
Dismantling and removing the existing Geysers of 25 litre capacity, any type, any make from various lacations of satellite area for repair / painting / replacement of defective parts, pressure testing, refixing at it's original location, connecting complete all as directed.
S & F Heating element, suitable for any type, any make geyser, 240V, AC, ISI Marked, with heat resistant rubber washer, for1.5 KW capacity, connecting complete all as directed.
S & F Thermostat control unit suitable for any type, any make. 25 Ltrs capacity geyser, 30-90 degree rating, 240V, AC, ISI Marked, connecting complete all as directed.
S & F indicating lamp unit round / rectangular type, suitable for any type, any make geyser, standard quality, AC, 240V, Red or Green, connecting complete all as directed.
S & F fusible plug made out of brass with internal or external threading suitable for any type, any make geyser of capacity 25 Ltrs complete all as directed.
S & F Inner assembly made out of brass wih chromium plating, with heat resistant rubber washer, suitable for any type, any make Geyser of 25 litre capacity, ISI marked, complete all as directed.
S & F inner tank made out of cast copper alloy, ISI Marked, suitable for any type, any make geyser of 25 litre capacity complete all as directed.
S & F Metallic Outer cover including bottom and top cover duly painted suitable for any type, any make geyser of 25 litre capacity complete all as directed.
M&L for repairs to metallic inner tank of any type, any make geyser of 25 litre capacity by arresting the leakage by welding, brazing etc, pressure testing after repairs, complete all as directed.
Taking down Heating element / Thermostat control unit / indicating lamp unit round / rectangular type
M&L for filling the glass wool between outer cover and inner tank of any type, any make geyser, 25 litres capacity, complete all as directed.
M&L for Preparing the surface of any type, any make geyser of 25 litre capacity, remove the existing painting by scraping, cleaning, filling the cavities and applying 2 coats of spray paint with synthetic enamel white paint over a coat of red oxide primer, including writing the MES No. all as directed.
M&L for Fabricate and fix, GI bottom cover / inspection plate, suitable for any type, any make geyser, 2 mm thick, split type, duly painted with 2 coats synthetic enamel paint over a priming coat of metallic primer to match with the existing colour all as directed.
M&L for replacement of bottom main terminal, synthetic gasket, fixing clamps suitable for any type, any make geyser, cleaning inner container/tank and assembly complete all as directed.
M&L for making hole in wall, Grouting 4Nos Rag Bolts of size 125mm long x 12mmm dia in PCC on wall including suitable nuts and washers for fixing / hanging geysers, complete all as directed.
S & F pressure / air release valve suitable for any type, any make geyser, made out of brass 15mm bore, ISI marked, complete all as directed.
S & F non-return valve, made out of brass 15mm bore, ISI marked, complete all as directed.
S & F low density polyethlyne pipe 16 mm dia (outer), 450mm long suitable for Hot water application complete with threaded brass union, teflone washers on both sides to suit 15 mm dia fittings.
Material,labour,transport and tools for rectification of urgent nature electrical complaints at satellite area as and when required (Trangini apartment,Fernson apartment,DERA enclave ,Varsha ,Varuna complex and Dawson Vihar) during off hours on all working days all as directed by Engineer-in-Charge. NOTE:- (i) The material incorperated for completion of work will be measured and paid seperately under relevent item. (ii) The contractor should display contact number at satellite area (Trangini apartment,Fernson apartment,DERA enclave ,Varsha ,Varuna complex and Dawson Vihar) to register users complaint. (iii) A recovery of Rs. 400/- per complaint will be levied from the contractor in case of non-attending complaints.
Material,labour,transport and tools for rectification of urgent nature electrical complaints at satellite area(Trangini apartment,Fernson apartment,DERA enclave ,Varsha ,Varuna complex and Dawson Vihar) during sundays and holidays all as directed by Engineer-in-Charge. NOTE:- (i) The material incorperated for completion of work will be measured and paid seperately under relevent item. (ii) The contractor should display contact number at satellite area (Trangini apartment,Fernson apartment,DERA enclave ,Varsha ,Varuna complex and Dawson Vihar) to register users complaint. (iii) A recovery of Rs. 400/- per complaint will be levied from the contractor in case of non-attending complaints.
M&L for Serviceability Check, Keep the fire fighting system functional round the clock, Attending Fire Practices as per users requirements, necessary Repair / Maintenance / Servicing of machineries and fittings of Fire Fighting Systems complete with Electrical Panel Boards, Removal / Replacement of defective parts incl sundry items viz. grease, lubricants, cotton waste, small pieces of cable lugs etc. which are not covered under spares of this schedule for the following location:- MAP (Powar, Panigrahi & Chandrashekhar Apt) at Dharamveer Enclave (a) 100 HP Electric Driven Fire Pump -1 No Powar/Panigrahi Apt (b) 92 HP Diesel Driven Fire Pump - 1 No Powar/Panigrahi Apt (c) 20 HP Electric Driven Jockey Pump - 1 No Powar/Panigrahi Apt (d)10 HP Electric Driven Terrace Pumpsets - 3 Nos Powar/Panigrahi/Cahndrashekhar Apt Varsha Enclave (a) Electric driven fire pump 40 HP - 02 Nos (b) Electric driven Terrace pump 10 HP - 02 Nos (c) Connected LT panel and pump panel - 01 No NOTE :- (i) The rate quoted by contractor shall deem to be included for cleaning of the premises of installation neat and tidy in all the manners. (ii) All Tools & Plants or Transport required for carrying out daily maintenance and necessary stationary & documents (log books, test records etc.) for maintaining the recods at each installation will be arranged by the contractor and nothing extra will be admissible on this account. (iii) The contractor should ensure full safety and functionability of the assets being maintained by him. Any casualty or injury sustained by the operators during the working hours at the premises of installations shall be sole liability of the contractor. No claim on this account shall be entertained by the Department. (iv) The quoted rates are deemed to be included for provision of communication facility by operators with JE / AGE / GE. (v) The contractor has to make on arrangemement for testing the fire fighting system every month in presence of representative of user & MES and produce the record of the same for verification.
S & F steel water tubing heavy duty galvanised 100mm ISI marked with all fittings like elbow, tee, bend, socket, reducers, flange, taper, nut, bolt, gasket etc fixed on walls or floor or roof including fixing with clamps made out of suitable size of angleIron and MS Flat on wall for Wet risers, Down comers etc. including painting with Signal Red synthetic enamel paint and taking down old items all as directed.
All as per Item No. 92 above but 80 mm dia
Supply, Lay and Jointing in repairs, DI pipes 150mm bore with flanged ends centrifugally cast class 'K9' in any length laid in trenches, floors or fixed to wall all as directed.
All as per Item No. 94 above but 100 mm dia
Material and labour in repairs for DI fittings such as bends, tee, single branch, 'y' junctions, double branch, straight connecting pieces any type and angle/radius etc for flanged pipes up to 150mm bore all as directed.
Supply, fix, test and commissioning of butterfly valve PN 1.6, bronze / Gun metal seat, ISI marked complete with Nuts, Bolts, washers, 3mm thick insertion rubber gaskets conforming to IS 13095 all as directed of size 150mm dia.
All as per Item No. 97 above but 100 mm dia
Supply and Fix in repairs horizontal type double flanged Non Return Butterfly valve, ISI Marked complete with bolts, nuts, washers, 3mm thick insertion rubber gaskets complete all as directed of size 150mm dia.
All as per Item No. 99 above but 100 mm dia
All as per Item No. 99 above but 80 mm dia
Supply and fix in repairs fabricated hose cabinet box mounted on wall made out of 18 gauge MS Sheet of size 800X600x250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside with lock two keys suitable for indoor use complete all as directed.
Supply and fix in repairs fabricated hose cabinet, mounted on PCC 1:3:6 foundation of size 800x600x1000mm, made out of 18 gauge MS Sheet of size 800X600x250mm with double door with 4 mm thick glass and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside with lock two keys suitable for outdoor use complete all as directed.
Supply and fix in repairs non-percolating type reinforced rubber cotton synthetic fibre circular woven jacketted fire delivery hose 63 mm dia treated against rot / mystex conforming to IS-636, 15 Mtr long with male and female SS coupling complete all as directed.Make:-Newage/Omex/Essel
Supply, fix in repairs and connect to wet riser, first-aid hose reel swinging wall mounted type comprising rubber hose 19mm dia 30m long high pressure double braided bearing, PVC shut off nozzle and 25mm gunmetal inlet valve conforming to IS-884 complete all as directed. Make:-Newage/Mahavir
Supply and fix in repairs landing valve (internal hydrant) Single headed SS conforming to IS, 63 mm female instantaneous outlet compelte with PVC blank cap with chain and having suitable flanges for 100 mm dia wet riser complete all as directed. Make:-Newage/Omex/Essel
Supply and fix in repairs Stainless steel branch pipe 63mm dia male instantaneous inlet, threaded outlet fitted with hexagonal based nozzle of 20mm dia heavy duty conforming to IS-903 complete all as directed. Make:-Newage/Omex/Essel
Supply, Fix, Connect and Testing in repairs, Fire brigade in let connection 4 way made out of gunmetal with flanged inlet and 63mm male instantaneous inlet with 150mm dia cast iron stand post including blank caps with chain, conforming to IS with flanged riser duck foot bend, 1m long 150mm dia short piece-1No, 150 mm dia Butter Fly Valve PN 16, bolts, nuts, washers and 3mm thick insertion rubber gaskets for flanged joints, painting with Signal Red synthetic enamel paint complete all as directed.
Supply, Fix, in repairsTesting and Commissioning of Pressure switch Universal type 3 Kg/cm² to 9 Kg/cm². Make : Danfoss / Indfoss
Supply, Fix,in repairs Testing and Commissioning of Pressure Gauge, 4" dia, 0 - 14 Kgs rating complete all as directed. Make:-Hguru
Supply, Fix,in repairs Testing and Commissioning of Gun metal Air release valve 25mm dia complete all as directed. Make:- SKS/SB/Kartar
Supply, Fix in repairs, Connect, Testing and Commissioning of IP:44 Inteliigent Addressable loop power Manual Call Point (Dual Action) with inbuilt turbo Isolator suitable for flush or surface mounting and shall have test key feature without removing the glass complete as per site requirement and conforming to EN 54 / LPCB / VDS / FM. Model No. FDM223 (FDME223+FDMH293-R) of Siemens Cerberus or equivalent of Honeywell Essar / Bosch
Supply and installation, testing and commissioning in repairs Addressible fire alarm sounders / siren electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 db nto 120 db measured at 1.5 mtr with sound output variation of+ 5 db, 500 Mtrs range.
Supply, Fix, Connect,in repairs Testing and Commissioning of IP:40 Inteliigent Addressable loop power Multi sensor (Heat and Smoke) Detector with inbuilt turbo isolator and integral response indicator with 360° viewing angle. Detector shall communicate 3 danger levels of differentiated alarm activation and height tolerance to Dust, Dirt, Temperture fluctuations and Air currents. Detector should have unique address for communication and assigned through panel including mounting base complete as per site requirement and conforming to EN 54 / LPCB / VDS / FM.
Shut down LT power supply and Dismantling and removing the motor of the mono block / coupled Pump set from existing position, Shifting to authorized workshop for the repair work, removing the burnt winding, cleaning rotor / stator, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc and installing back to the original position, testing and commissioning on full load for 8 hrs continuous running for 10 HP 3 phase, AC, 415V motor all as specified & directed by Engr-in-Charge
All as per item No.115 above, but 20 HP 3 phase, AC, 415V
All as per item No.115 above, but 100 HP 3 phase, AC, 415V
Dismantling and removing the mono block / Coupled pump set from the existing positing, opening the pump set, removing the unserviceable ball bearing from motor or pump side, supply and fix new ball bearing of suitable size (Make : SKF ) for pump set of capacity 10 HP 3 phase, AC, 415 V, testing and commissioning on full load for 8 hrs continuous running, all as specified & directed by Engr-in-Charge.
All as per item No.118 above, but 20 HP 3 phase, AC, 415V
All as per item No.118 above, but 100 HP/ 92 BHP 3 phase, AC, 415V
Shut down LT power supply and Dismantling and removing the existing unserviceable motor starter from the panel board supply and fix new starter of the same capacity in the panel board including necessary connections testing and commissioning etc for DOL starter 3 phase, AC, 50Hz, 415Volts make L & T MN 16 DOL or equivalent suitable for pump of capacity up to 10 HP with relay range 9 to 15Amps all as specified and directed by the Engineer - in - Charge
All as per item No.121 above, but Fully Automatic star delta motor starter 3 phase, AC, 50Hz, 415Volts make L & T MN 25 FASD or equivalent suitable for pump set capacity up to 20 HP with relay range 14 to 23 Amps
All as per item No.121 above, but Fully Automatic star delta motor starter 3 phase, AC, 50Hz, 415Volts make L & T MN 110 FASD or equivalent suitable for pump set capacity up to 100 HP with relay range 66 - 110 Amps
Removing the U/S single phase preventor, Supply & Fix Single phase preventor suitable for 3phase pump sets of any capacity, Make : L & T all as directed.
Removing the U/S contactors, Supply & Fix 3 phase, 3 pole power contactor,18 Amps, 415V, suitable motor starters of AC3 rating
All as per item No.125 above, but 25 Amps
All as per item No.125 above, but 125 Amps
Dismantling brass bush of the pump set of 10 HP capacity and replacing with new one all as directed.
All as per item No.128 above, but 20 HP pump
All as per item No.128 above,but 100 HP/ 92 BHP 3 phase, AC, 415V
Removing U/S CI foot valve 150mm dia and replacing with new Cast Iron foot valve Ball Type heavy duty all as directed. Make: Normex
Preparing the surface by scrapping the old painting and removing the grease, oil, dirt etc, Spray painting with one coat of super enameled anti corrosive paint of approved colour, over a coat of auto primer, for 10 HP 3 phase pump set including metallic base channel complete all as directed.
All as per item No.132 above,but 20 HP 3 phase
All as per item No.132 above,but 100 HP 3 phase
All as per item No.132 above,but 92 BHP 3 phase
Disconnect and remove burnt out No-Volt coil, Supply and fix No Volt Coil suitable for 3 phase motor starters, AC, 415V, connecting, testing complete
M&L for Servecing /maint /repair of diesel engine driven pumping set of capacity 92 BHP removing of defective parts and replacing with new parts like diesel pipe ,fuel line from pump to injectors, oil pipe 'o' rings ,gaskets, belt, radiator hose clip,battery leads with terminals including necessary nuts ,bolts and washer ,carbon brushes, coupling pad, replacement engine oil along with fuel filter,oil filter and air cleaner filter element as per existing make and type and filling of distilled water ,electrolyte ,mineral jelly for battery teminals ,cut out relay 24 volt/12 volt,including cleaning of fuel tank, engine oil pump etc. as directed. NOTE:- (a) Engine oil, radiator coolent etc. will be measured and paid separately under relevant items as supply only. (b)The unit rate quoted shall be deemed to be inclusive of cost of labour for dismantilng Gen set complete for replacement of defective parts re-assembling the same after carrying out the repair as described. (c) The cost of minor parts which are not mentioned in item, but are essential for satisfactory functioning of the DG set shall be deemed to be included in the rate quoted for the item.
Repair self starter of pumping set 12 V /24 V transporting to local wksp, removing the starter, winding, re-winding, with super enameled copper winding wire of existing capacity, Varnishing, drying heating, refixing the starter including replacement of worn out bearing 01 no greasing complete all as directed and refixiing the same including testing for pump set of capacity 92 BHP
Material and labour for removing radiator from engine cleaning and descalling the top / bottom tanks and fans repairing the fins / blocking the leaking fins, refitting the same to engine, supply and filling with new coolant to the capacity of radiator all as directed for diesel driven pump set of capacity 92 BHP
Supply only Coolent Castrol Radicool (Premixed) for radiator (ref. item 40.2)
Supply only engine oil 20 W 40, Make : Castrol/HP (ref. item 40.2)
Supply, fix, test and commissioning of Sluice valve PN 1.6, 150mm, ISI marked complete with Nuts, Bolts, washers, 3mm thick insertion rubber gaskets conforming to IS 13095 all as directed.
Supply and fix in repairs Hydrant valve adapter instantaneous outlet of landing valve S/S conforming to IS, 63 mm compelte with PVC blank cap with chain complete all as directed.
Solar Water Heating System Servicing and maintenance of complete solar water heater plant of cap 1000 LPD installed at multi story bldgs for carring out minor leakage,cleaning of flat plate collector & sintex tank and make up tank incl dismantling inlet and outlet connection and refixing the same after cleaning for proper functioning to maintain proper water temperature,complete all as specified.
Supply, install, commissioning of indoor type LT panel board in angle iron frame made of 40x40x6mm MS angle and 2mm thick CRS sheet, duly fixed on floor, with aluminium bus bar of 200 Amps capacity and fixing arrangement for 9 Nos existing single phase energy meter, including painting internallyt and externally with two coats of synthetic enamel paint over a coat of red odixe zinc chromate primer including preparation of surface complete compricing the following:- (a) Main incoming MCCB 4 pole 100 Amp (Make L&T) - 01 No. (b) MCB SPN 63 Amps (Make L&T) - 08 Nos (for Qtrs) (c) MCB SPN 32 Amps (Make L&T) - 01 No (for common area) (d) Shifting of energy meters - 09 Nos (e) Marking of all MCBs and meters with quarter numbers. (f) Necessary sub main wiring with proper size copper cable including cable glands, thimbles etc all as per site requirement. (g) Removal of old LT panel and its accessories.
M&L for replacement of rubber hose pipe 15mm dia between hot water tank & collector complete. Make -As per sample
M&L as in repairs galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
M&L as in repairs galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
Supply and fixing of CPVC pipesSDR 13.5 and plain CPVC SDR 11 fittings complete which ever be required for fixing on wall/ceiling or laying in floor/concealed of size 25 mm outer dia of CPVC pipe complete all as specified and directed including taking down old one
S & F float valve assembly made out of gun metal 20 mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repairs Gun-metal gate valve, with iron wheel head, screwed both ends 15 mm bore Complete.
Supply and fixing as in repairs Gun-metal gate valve, with iron wheel head, screwed both ends 20 mm bore Complete.
S&F as in repair Non return valve 15mm dia horizontal/vertical type complete all as specified and as directed by Engineer-in-Charge.
Supply, install, test and commissioning Inverter split type Air conditioner single phase electric driven cooling capacity 2.0 TR (6000 K Cal/Hr) indoor and out door complete with cordless remote control unit, hidden LED display, super test filter multi fold evaporator, eco- friendly refrigerent auto restart and self diagnosis function with 3 star rating and factory made stand for ODU complete all as specified and directed (Make Voltas/ Carrier/ Bluestar/Usha- Daikin/ Hitachi
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA Make : V Guard/ Blue Line/
M&L for submain wiring with 2 runs of 4 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade drawn in and including PVC rigid conduit and one run of 4 Sqmm PVC insulated unshearthed single core 1100 volts grade multistranded copper conductor cable as earth continuity condutor and connceting with suitable size thimble complete all as specified and as directed. Note: Two run of 4 sqmm size copper cable , one run of 4 Sqmm size PVC cable as earth wire and one run of PVC conduit together shall be measured as one length of wiring.
S&F Sheet metal enclosures with socket plug top and MCB' single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB
Kuriako Mathai and company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .