Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance VILL KISHANPURA P O JAMNIWALA TEHSIL PAONTA SAHIB DISTRICT SIRMOUR HP | PAONTA SAHIB | SIRMOUR | HIMACHAL PRADESH | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical BANSAL COTTAGE BADRI NAGAR TEH PAONTA SAHIB SIRMAUR | SIRMAUR | HIMACHAL PRADESH | 173025 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹14.3 L
EMD Value
₹28,500
Closing Date
26 Oct 2021, 11:00 amClosed
Executive Engineer
Jal Shakti Division Paonta Sahib
Supply Errection and Commissioning of Submersible Puming Machinery of LWSS in Paonta Sahib Sub Division
2021_HPIPH_53011_3
PNT-SMR-02-720 No. 11035-134 Dated 13/10/2021
Open Tender
Civil Works
Item Rate
90 days
Paonta Sahib
Please refer to tender documents
9 documents required · 9 mandatory
₹400
₹28,500
Yes
31 Dec 2021
15 Oct 2021
26 Oct 2021
15 Oct 2021
26 Oct 2021
15 Oct 2021
15 Oct 2021 - 26 Oct 2021
Amount
Supply, erection, testing & commissioning of submersible pumping set of reputed make such as KSB/BS/Johnston/Worthington/SABAR/OSWAL conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:-
Pumping Hours:- 8 hours
LWSS Rajban Muglawala
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 98.00 Mtr.
i)Static Head:-
Capacity (in LPS):- 12.80 LPS
Dia of R/Main (in mm) - 125 mm dia
Dia of Column pipe (in mm)-125 mm dia
Length of Rising main :- 320 mtr.
T/Well Shivpur Bangran
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 45.00 Mtr.
i)Static Head:-
Capacity (in LPS):- 3.50 LPS
Dia of R/Main (in mm) - 80 mm dia
Dia of Column pipe (in mm)-80 mm dia
Length of Rising main :- 50 mtr.
T/Well Mohkampur Nawada
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 50.00 Mtr.
i)Static Head:-
Capacity (in LPS):- 17.50 LPS
Dia of R/Main (in mm) - 80 mm dia
Dia of Column pipe (in mm)- 80 mm dia
Length of Rising main :- 50 mtr.
T/Well Amarkot Nihalgarh
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 105.00 Mtr.
i)Static Head:-
Capacity (in LPS):- 12.00 LPS
Dia of R/Main (in mm) - 100 mm dia
Dia of Column pipe (in mm)-100 mm dia
Length of Rising main :- 50 mtr.
T/Weell Paonta Town Phase-I
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 150.00 Mtr.
i)Static Head:-
Capacity (in LPS):- 8.40 LPS
Dia of R/Main (in mm) - 80 mm dia
Dia of Column pipe (in mm)-80 mm dia
Length of Rising main :- 110 mtr.
T/Well Paonta Town (Gharat Colony)
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 90.00 Mtr.
i)Static Head:-
Capacity (in LPS):- 42.00 LPS
Dia of R/Main (in mm) - 200 mm dia
Dia of Column pipe (in mm)-200 mm dia
Length of Rising main :- 611 mtr.
T/Well Paonta Town Phase-III
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 75.00 Mtr.
i)Static Head:-
Capacity (in LPS):- 11.40 LPS
Dia of R/Main (in mm) - 80 mm dia
Dia of Column pipe (in mm)-80 mm dia
Length of Rising main :- 70 mtr.
T/Well Badripur
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 90.00 Mtr.
i)Static Head:-
Capacity (in LPS):- 7.50 LPS
Dia of R/Main (in mm) - 100 mm dia
Dia of Column pipe (in mm)-100 mm dia
Length of Rising main :- 180 mtr.
LWSS Haripur Tohana
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 45.00 Mtr.
i)Static Head:-
Capacity (in LPS):- 6.50 LPS
Dia of R/Main (in mm) - 40 mm dia
Dia of Column pipe (in mm)-40 mm dia
Length of Rising main :- 250 mtr.
LWSS Devi Nagar
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 90.00 Mtr.
i)Static Head:-
Capacity (in LPS):- 7.00 LPS
Dia of R/Main (in mm) - 50 mm dia
Dia of Column pipe (in mm)-50 mm dia
Length of Rising main :- 710 mtr.
LWSS Bhuppur Kedarpur
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 60.00 Mtr.
i)Static Head:-
Capacity (in LPS):- 7.50 LPS
Dia of R/Main (in mm) - 80 mm dia
Dia of Column pipe (in mm)-80 mm dia
Length of Rising main :- 690 mtr.
Sohal Pal Singh
Dharmender Chandel
Dharmender Singh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .