| 1 | L1₹148.2 CrAccepted-AOC | ₹148.2 Cr Quoted ₹156.0 Cr | L1 | Accepted-AOC As per recommendation of the Tender Committee |
| 2 | L2₹163.2 CrRejected-AOC BHASKAR NAGAR BYE LANE NO 2 GUWAHATI 21 | SOUTH SALMARA MANCACHAR | ASSAM | 783127 | ₹163.2 Cr | L2 | Rejected-AOC As per recommendation of the Tender Committee |
Tender Value
Refer Docs
EMD Value
₹1.4 Cr
Closing Date
29 Dec 2020, 2:00 pmClosed
Chief Engineer (EAP), PWRD Assam
Office of the Chief Engineer (EAP), PWRD Assam, Fatasil Ambari, Guwahati-781025
CE/AM/SOPD(L1)/36/2020-21/6 Improvement and Upgradation of Road from Dhupguri to Dhekiajuli and Kalisthan to Gupteswar Temple under Asom Mala
2020_PWD_19705_1
CE/AM/SOPD (Lot1)/45/2020-21/38
Open Tender
Civil Works – Roads
720 days
Sonitpur
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,000
Assam State Road Board A/C No. 10566991479
₹1.4 Cr
Yes
Office of the Chief Engineer (EAP), PWRD Assam, Fa
13 Aug 2021
21 Dec 2020
29 Dec 2020
21 Dec 2020
29 Dec 2020
21 Dec 2020
21 Dec 2020 - 24 Dec 2020
24 Dec 2020
Amount
Minor Bridge Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal and disposal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Upto 3 m depth Ordinary Soil
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal and disposal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Marshy Soil
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. PCC - M15 For Foundation
Providing and Laying Cutting Edge of Mild Steel weighing 40 kg per metre for Well Foundation complete as per Drawing and Technical Specification.
Plain/Reinforced Cement Concrete, in Well Foundation complete as per Drawing and Technical Specification. With Batching Plant, Transit Mixer and Concrete Pump Well curb RCC M30 Grade
Plain/Reinforced Cement Concrete, in Well Foundation complete as per Drawing and Technical Specification. With Batching Plant, Transit Mixer and Concrete Pump Well steining RCC M30 Grade
Plain/Reinforced Cement Concrete, in Well Foundation complete as per Drawing and Technical Specification. With Batching Plant, Transit Mixer and Concrete Pump Bottom Plug PCC Grade M20
Plain/Reinforced Cement Concrete, in Well Foundation complete as per Drawing and Technical Specification. With Batching Plant, Transit Mixer and Concrete Pump Intermediarte Plug PCC Grade M20
Plain/Reinforced Cement Concrete, in Well Foundation complete as per Drawing and Technical Specification. With Batching Plant, Transit Mixer and Concrete Pump Well cap RCC Grade M30
Providing and Filling Sand in Wells complete as per Drawing and Technical Specifications.
Sinking of 5 m external diameter well (other than pneumatic method of sinking) through all types of strata including sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth below bed level upto 3.0 M
Sinking of 5 m external diameter well (other than pneumatic method of sinking) through all types of strata including sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Beyond 3m upto 10m depth
Sinking of 5 m external diameter well (other than pneumatic method of sinking) through all types of strata including sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Beyond 10m upto 20m ( including dewatering)
Supplying, fitting and placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications.
Plain/reinforced cement concrete in substructure complete as per drawings and technical specifications With Batching Plant, Transit Mixer and Concrete Pump R.C.C. grade M-35 Height upto 5m
Plain/reinforced cement concrete in substructure complete as per drawings and technical specifications With Batching Plant, Transit Mixer and Concrete Pump R.C.C. grade M-35 Height 5m to 10m
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications.
Providing and laying of Filter media with granular materials/stone crushed aggregates behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) and technical specifications complete including all accessories as per drawing and Technical Specifications.
Providing and Fixing Tar paper bearing including laying in proper position etc. completed
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification PSC Grade M-35, Using Batching plant
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification PSC Grade M-35, Using Batching plant
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification Sesmic Arrester and Pedestail PSC Grade M-45, Using Batching plant
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification PSC Grade M-50, Using Batching plant
RCC Crash Barrier including reinforcement complete as per drawing and Technical Specifications
Tubular Steel Railing on Precast RCC posts, 1.2 m high above ground level (Providing, fencing and erecting 50 mm dia painted steel pipe railing in 3 rows on precast M20 grade RCC vertical posts1.8 metres high (1.2 m above GL) with 3 holes 50 mm dia for pipe, fixed 2meters center to center, complete as per approved drawing.
High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
Providing and laying of an strip seal expansion joint complete as per drawing and Technical specification for road & bridge works.
Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.
Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.
150 thk. Flat Stone (Rigid flooring) Apron embedded in 300 thk concrete (M15) complete as per drawing and Technical specification.
Providing and Fixing Drainage Spouts complete as per drawing and Technical specification.
Providing and laying mastic asphalt wearing course complete as per drawing and Technical Specifications
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
Bituminous Concrete Providing and laying bituminous concrete complete as per drawing and Technical Specifications (i) with PMB-70 Grade Bitumen (i) for grading II (13mm nominal size)
Bituminous Concrete Providing and laying bituminous concrete complete as per drawing and Technical Specifications (i) with PMB-70 Grade Bitumen (i) for grading II (13mm nominal size)
Painting two coats after filling the surface with synthetic enamel paint in all shades on new concrete surfaces
Road Work Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lead and lifts and earth/sand filling in the depression/pit created as per Technical specifications a) Girth from 300 mm to 600 mm
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lead and lifts and earth/sand filling in the depression/pit created as per Technical specifications b) Girth from 600 mm to 900 mm
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lead and lifts and earth/sand filling in the depression/pit created as per Technical specifications c) Girth from 900 mm to 1800 mm
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lead and lifts and earth/sand filling in the depression/pit created as per Technical specifications d) Girth above 1800 mm
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Girth from 300 mm to 600 mm
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Girth from 600 mm to 900 mm
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Girth from 900 mm to 1800 mm
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Girth above 1800 mm
Clearing and Grubbing Road Land .Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of roots of trees cut earlier and disposal of unserviceable materials, stacking of serviceable material to be used as directed by Engineer
Dismentling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 m, stacking serviceable and unserviceable materrials separately,By mechanical means. Bituminous courses
Dismentling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 m, stacking serviceable and unserviceable materrials separately,By mechanical means. Granular courses
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead Plane Cement Concrete of any grade
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead Prestressed / Reinforced cement concrete grade M-20 & above
Removing all type all diameter of hume pipe culverts including masonry works and stacking pipes at location shown by Engineer Upto 600 mm dia
Removing all type all diameter of hume pipe culverts including masonry works and stacking pipes at location shown by Engineer Above 600 mm to 900 mm dia
Removing all type all diameter of hume pipe culverts including masonry works and stacking pipes at location shown by Engineer Above 900 mm
Dismantling of Cement Concrete Pavement (Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials with all lead and lifts ,stacking serviceable materials and unserviceable materials separately.) Removal of Paver Block
Excavation in Soil using Hydraulic Excavator Tippers with disposal all lead and lifts. (Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes,in accordance with requirements of lines, grades and cross sections,loading disposal of excavated earth with in all lifts and leads or for reuse if suitable for embankment/subgrade at other location).
Excavation in Marshy Soil (Excavation for roadway in marshy soil with hydraulic excavator including cutting and loading in tippers and disposal with in all lifts and lead , trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections.)
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers within all lifts and leads. (Excavation for roadway in ordinary rock with hydraulic excavator including cutting and loading in tippers, transporting to embankment site within all lift and lead , trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections.)
Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirements of Technical specifications
Construction of Embankment with materials deposited from roadway cutting Construction of embankment with approved Material Deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2
Construction of Subgrade/Median/ Earthen Shoulders-Construction of sub-grade,Median and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 Subgrade and earthen shoulder
`Median Filling with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of technical specification
Compacting original ground supporting sub-grade Loosening and Recompaction of the ground upto a level of 500 mm below the sub-grade level, watered, graded and compacted in layers to meet requirement of table 300-2 for sub-grade construction.
Granular Sub-Base with Coarse Graded Material, Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical specifications. For Grading V Material
Construction of granular sub-base by reuse of excavated roadway material mainly WBM etc. from existing road , taking to plant area ,crushing to size and mixing suitable materials required to bring it to desired grading latter spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification. For Grading V Material
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate as per Technical specificationnincluding premixing the Material with water at OMC in mechanical mix plant, carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
Prime Coat Providing and applying primer coat as per Technical specifications with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per spreading rate approved by Engineerand
Tack Coat Providing and applying tack coat with bitumen emulsion as per Technical specifications by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.
Dense Bituminous Macadam Providing and laying dense bituminous macadam Grading II (19mm nominal aggregate size) using VG 30 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade and alignment, compacting to achieve the desired compaction as per Technical specification clause complete in all respects
Bituminous Concrete Providing and laying bituminous concrete Grading I (13mm nominal aggregate size) using PMB 70 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, compacting to achieve the desired compaction as per Technical specification complete in all respects
Providing and laying Interlocking Concrete Block Pavement (ICBP) conforming to IS:15658-2006 including sand below block & Side packing M15 concrete with all lead and lift complete as per technical specification and as directed by Engineer In-Charge. 80mm thick interlocking precast blocks having compressive strength of 40N/sq.mm
Cast in Situ Cement Concrete M20 kerb with kerb laying machine, foundation concrete laid manually as per given drawing and Technical specifications, all complete
Painting Two Coats on New Concrete Surfaces’ Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compactedby vibration including curing for 14 days.)
Plain /Reinforced cement in open foundation complete as per drawing & technicla specifications as MoSRT&H, 1500, 1700, 2100 RCC grade M20 using concrete mixure
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Secondary Producer (ISI approved)
Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technicalspecification.
Providing and laying of a PVC rain water pipe 100mm Dia complete as per drawing and Technical Specification
Providing a Pipe Culvert for Access Road complete as per drawing and Technical Specification
Kilometre Stone: Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc. 5th kilometre stone (precast)
Kilometre Stone: Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc. Ordinary Kilometer stone (Precast)
Kilometre Stone: Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc. Hectometer stone (Precast)
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 as per approved drawing and Technical Specification 90 cm equilateral triangle
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 as per approved drawing and Technical Specification 60 cm equilateral triangle
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 as per approved drawing and Technical Specification 60 cm circular
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 as per approved drawing and Technical Specification 80 mm x 60 mm rectangular
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 as per approved drawing and Technical Specification 60 cm x 45 cm rectangular
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 as per approved drawing and Technical Specification 60 cm x 60 cm square
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 as per approved drawing and Technical Specification 90 cm high octagon
Direction and Place Identification Signs upto 0.9 sqm Size Board. Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing
Direction and Place Identification Signs with size more than 0.9 sqm size Board. Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing
Providing and erecting overhead Signs Gantry including Truss, Verticle Post and concrete foundation all complete Job as per approved drawing and plans and Technical specifications complete
Matal Beam Crash Barrier Type - A, “W” : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS : 1367 and IS : 1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x5 mm, 546 mm long complete as per clause 811.3) complete job as per approved drawings.
Flexible Crash Barrier, Wire Rope Safety Barrier (Providing and erecting a wire rope safety barrier with vertical posts of medium weight RS Joist (ISMB series) 100 mm x 75 mm (11.50 kg/m), 1.50 m long 0.85 m above ground and 0.65 m below ground level, split at the bottom for better grip , embeded in M-15 grade cement concrete 450mm X 450mm X 450mm, 1.50m center to center with 4 horizantal steel wier rope 40mm dia and anchored at terminal posts 15m apart. Terminal posts to be embeded in M15 grade cement concrete foundation 2400 X 450 X 900mm (Depth), strengthed by a strut of Rs joists 100X75mm. 2m long at 450 inclination and a tie 100 X 8mm, 1.50m long at the bottom, all embeded in foundation concrete as per approved design and drawing rate excluding excavation and cement concrete.)
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.
Boundary pillar Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting
Cable Duct Across the Road Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of of granular material over top and sides of RCC pipe as per IRC 98-1997, bedded on a 0.3 m thick layer of granular material free of rock pleces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC 98 - 1997 and approved drawings, Single Row for one utility service
Padestrain Guard Rail : Tubular Steel Railing on Medium Weight steel channel ( ISMC series) 100 mm x 50 mm (Providing, fixing and erecting 50 mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 1.2 metres high above ground, 2 m centre to centre, complete as per approved drawings and Technical Specification)
Road Stud with Lense Reflector providing and fixing metal road stud with dimensions 100x100x19.8 mm length anchoring shank: 50mm aliminium body Two way reflective with 2x43 glass elements
Provision of Median kerb on road , constructed with with top and bottom width 100mm and 200 mm respectively, 850 mm high with M - 20 grade concrete conforming to IRC:21, installed as per approved drawings and at locations as directed by the Engineer.
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compactedby vibration including curing for 14 days.)
Plain /Reinforced cement in open foundation complete as per drawing & technicla specifications as MoSRT&H, 1500, 1700, 2100 RCC grade M20 using concrete mixure
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade , sloped towards the kerb, kerb stone with channel laid with kerb laying machine,foundation concrete manually all complete as per clause 408.)
Supply & instalation of solar street light propsed at Major & Minor Junction Location , Bus Bay & Bus Shelter Location as per drawing and Technical specifications
Construction of R.C.C Bus shelter at Village Portion as per drawing and Technical specifications
Construction of Bus Bay at Village Portion aas per drawing and Technical specifications
Box Culvert Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump
Furnishing and Placing Reinforced/ Prestressed cement concrete in superstructure as per drawing and Technical Specification’ including steel shuttering formwork. RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. PCC Grade M15
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size toeards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification.
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Depth upto 3 m
Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Backfilling behind abutment, wing wall and return wall complete as per drawings and Technical Specification. Granular Material
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork Return Wall RCC Grade M30 With Batching Plant, Transit Mixer and Concrete Pump
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications Return wall
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. Return Wall PCC M-15
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size toeards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification. Return Wall
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Return Wall Depth upto 3 m
Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification. Return Wall
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. Curtain Wall (M15)
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Curtain Wall Depth upto 3 m
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications. Stone/Boulder
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification
Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.
Rigid Appron:-Providing and laying Flooring complete as per drawing and Technical specifications laid over cement concrete bedding. Rubble stone laid in cement mortar 1:3
Provision of reinforced cement concrete crash barrier (New Jersey Type) on structure, constructed with M - 40 grade concrete with HYSD reinforcement conforming to IRC:21, including 50mm dia railing with fixtures and installed as per approved drawings and at locations as directed by the Engineer.
Mastic Asphalt (Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-29( binder having penetration as (15+/- 5) at 25 deg. centrigrade), prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing anti skid surface with bitumen pre coated fine grained hard stone ships of 13.2mm nominal size at the rate of .005cum per 10 sqm. and at an approximate spacing of 10 cm center tpo center in both direction , pressed into surface when the temperature of surfaces not less than 1000C, protuding 1mm to 4mm over mastic surface , all complete as per clause 515
Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, lel and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per drawing and technical specification complete in all respects (i) with PMB-70 Grade Bitumen (i) for grading 2 (13mm nomunal size)
Painting Two Coats on New Concrete Surfaces Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
Retaining wall Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork (Foundation) Retaining Wall RCC Grade M30 With Batching Plant, Transit Mixer and Concrete Pump
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (Wall up to 05 m) Retaining Wall RCC Grade M30 With Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications. Retaining Wall
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications Retaining Wall
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. Retaining wall PCC Grade M15
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size toeards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification. Retaining Wall
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Depth upto 3 m Retaining Wall
Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification. Retainine Wall
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications. Stone/Boulder Retaining wall
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification. Retaining wall
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. For Chute Drain
Replacement of Expansion Joints complete drawing and technical specification
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal steel/ Shyam steel or equivalent)
Tack coat Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom.( Including cost of testing of materials at site and laboratory as directed by the deptt
Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, lel and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per drawing and technical specification complete in all respects (i) with PMB-70 Grade Bitumen (i) for grading 2 (13mm nomunal size)
Mastic Asphalt (Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-29( binder having penetration as (15+/- 5) at 25 deg. centrigrade), prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing anti skid surface with bitumen pre coated fine grained hard stone ships of 13.2mm nominal size at the rate of .005cum per 10 sqm. and at an approximate spacing of 10 cm center tpo center in both direction , pressed into surface when the temperature of surfaces not less than 1000C, protuding 1mm to 4mm over mastic surface , all complete drawing and technical specification
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification
Guniting concrete surface with cement mortar applied with compressor after cleaning surface and spraying with epoxy complete as per Technical specification
Applying epoxy mortar over leached, honey combed and spalled concrete surface and exposed steel reinforcement complete as per Technical specification
Clearing Grass and Removal of Rubbish ( clearing grasss and removal of rubbish upto distance of 50m outside the periphery of the area.)
Painting Two Coats on New Concrete Surfaces’ Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
Day Work Schedule Un-skilled Labour
Semi-skilled Labour
Skilled Labour
Highily Skilled Labour
Cement
Stone chips 40 mm size
Stone chips 20 mm size
Stone chips 10 mm size
Coarse Sand
High Yield Strength Deformed reinforcing Steel
Bitumen VG-30
Bitumen PMB-70
Bitumen Emulsion (CSS 1)
Sub-Base Materials
Base Materials
Premix carpet
Seal coat
Tiper (Capacity 5.0 cum)
Water Tanker (Heavy)
Excavator (Bucket capacity 1.0 cum)
Front End Loader (Bucket Capacity 1.0 cum)
Tractor including blade or ripper
Road Roller (Capacity 8-10T)
Motor Grader (Heavy)
Air Compressor
ANUPAM NIRMAN PVT. LTD.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid