Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹23.8 L+₹2.2 L (10.2%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L2 | Rejected-Finance Not L1. | |
| 3 | L3₹24.0 L+₹2.4 L (10.9%)Rejected-Finance | L3 | Rejected-Finance Not L1. | |
| 4 | L4₹24.1 L+₹2.5 L (11.3%)Rejected-Finance | L4 | Rejected-Finance Not L1. | |
| 5 | L5₹24.1 L+₹2.5 L (11.4%)Rejected-Finance | L5 | Rejected-Finance Not L1. |
Tender Value
₹19.9 L
EMD Value
₹40,000
Closing Date
26 Jul 2022, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINTENANCE OF CEILING FAN, EXHAUST FAN, WALL MOUNTED FAN AND OTHER APPLIANCES ALONGWITH CONNECTED REPAIR WORK AT AF-I UNDER GE (AF) JAMNAGAR NO.2
2022_MES_532558_1
8358/E8
Open Tender
Miscellaneous Works
Item Rate
300 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹40,000
Yes
6 Aug 2022
21 Jun 2022
27 Jul 2022
21 Jun 2022
26 Jul 2022
5 Jul 2022
Amount
Taking down carefully ceiling fan / exhaust fan / cabin fan / wall mounted fan by disconnecting electric connection for carrying out repairing such as rewinding, replacement of defective spare part, over hauling and painting etc as required and re-fixing in the same position after carryout the repairs works, and connecting complete all as specified and directed. Note: Repairing such as rewinding, replacement of defective spare part, connecting wire, Over hauling and painting etc will be measured & paid separately under subsequent items.
M & L for rewinding of ceiling fan of any make by dismantling the ceiling fan, removing shaft, bearingand bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing and reassembling. Providing three core copper cable PVC insulated multistranded 0.5mm 30cm length for connection of fan from ceiling rose and testing of fan complete all as specified and directed. Rewinding should be carried out for the following size of ceiling fan:-
(a) 1200mm sweep
(b) 1400 mm sweep
M & L for rewinding of exhaust fan motor of any make by dismantling the exhaust fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing, applying cotton tape and reassembling complete. Providing twin core copper cable 30cm length for connection and testing of fan complete all as specified and directed. Rewinding should be carried out for the following size of exhaust fan:-
(a) 450mm sweep
(b) 300mm sweep
(c) 200mm sweep
M & L for rewinding of Pedestal fan motor of any make by dismantling the Pedestal fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing, applying cotton tape and reassembling complete. Testing of fan should be carried out to entire satisfaction of Engr-in-charge. The size of pedestal fan for rewinding shall be as under:-
(a) 300 mm sweep.
(b) 450 mm sweep.
(c) 600 mm sweep.
M & L for rewinding of Wall mounted fan / Air circulator motor of any make by dismantling the wall mounted fan / air circulator of 450mm sweep, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing, applying cotton tape and reassembling complete. Testing of fan should be carried out to entire satisfaction of Engr-in-charge.
M & L for rewinding of Wall mounted fan / Air circulator motor of any make by dismantling the wall mounted fan / air circulator of 600mm sweep, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing, applying cotton tape and reassembling complete. Testing of fan should be carried out to entire satisfaction of Engr-in-charge.
Supply and fix in repair ball bearing of any size suitable for ceiling fan 1200mm / 1400mm sweep complete all as specified and directed. Make:- SKF/NBC/FAG
Supply and fix in repair Gun metal bush of any size suitable for ceiling fan of 1200 mm / 1400 mm sweep complete all as specified and directed.
Supply and fix in repair Gun metal bush of any size suitable for exhaust fan 300 / 450 mm sweep complete all as specified and directed.
Supply and fix in repair capacitor 2.5 MFD AC 230 Volt 50 HZ, for ceiling fans complete all as specified and directed. Make:- FALCON/EPCOS/TIBCON
Supply and fix in repair capacitor 4 MFD AC 230 Volt 50 HZ, of exhaust / bracket fan any size complete all as specified and directed. Make:- FALCON/EPCOS/TIBCON
Supply and fix in repair capacitor 3.15 MFD AC 230 Volt 50 HZ, of exhaust / bracket fan any size complete all as specified and directed. Make:- FALCON/EPCOS/TIBCON
Supply and fix in repair capacitor 5 MFD AC 230 Volt 50 HZ, of exhaust / bracket fan any size complete all as specified and directed. Make: FALCON/EPCOS/TIBCON
Supply and fix in repair bolt, nuts, washer and split pin for the down rod of ceiling fan complete all as specified and directed.
Supply and connection in repair PVC insulated, PVC sheathed three core copper conductor cable multi stranded of size 0.5 Sqmm for connecting of fan from ceiling rose complete all as specified and directed. Make:- Finolx/Havells/RR Kabels.
Material and labour for painting of ceiling fan including blades by scrapping of old paint, filling of cavities formed, preparation / cleaning of surface, making surface smooth and spray painting with one coat of white synthetic enameled paint of superior quality and writing MES /SM No with appropriate size letters using black paint complete all as specified and directed.
Material and labour for painting of exhaust fan including blades by scrapping of old paint, filling of cavities formed, preparation / cleaning of surface, making surface smooth and spray painting with one coat of white synthetic enameled paint of superior quality and writing MES /SM No with appropriate size letters using black paint complete all as specified and directed.
M & L for re-assembling & fixing only ceiling fan of various sizes complete with blades, down rod canopy etc including hanging in position and connecting complete all as specified and directed.
M & L for re-assembling & fixing only exhaust fan of various sizes complete with blades, fixing with 4 nos hold fastener nut and bolt with washer and connecting with flexible PVC insulated multistranded copper conductor cable of size 0.75 sqmm from ceiling rose to exhaust fan complete all as specified and directed.
Supply and fix of Fan clamp and rubber bush including nut, bolts, washers and split pin for hanging of ceiling fans complete all as specified and directed.
Supply and fixing ceiling fan MS clamp including nut, bolts and washers for various shapes and sizes for fixing of MS channel / pipe / angle complete all as specified and directed.
Supply and fix in repair Fan Rod of size 300mm long for ceiling fans complete all as specified and directed.
Supply and fix in repair Fan Rod of size 450mm long for ceiling fans complete all as specified and directed.
Supply and fix in repair Fan Rod of size 600mm long for ceiling fans complete all as specified and directed.
Supply and fix in repair Fan Rod of size 1050mm long for ceiling fans complete all as specified and directed.
Supply and fix in repair Plastic louvers for Exhaust fan along with connected accessories for 200 mm and 300 mm dia sweep exhaust fan complete all as specified and directed.
S&F in repair poly propylene plastic louver shutter (flap type) of size 350 mm x 350 mm, circulating opening 310 mm dia, fixed on wall for exhaust fan with screw complete all as specified and directed. Make: OMAX plastic / Sintex
Supply and fix in repair stepped type electronic fan Regulator surface type on the existing phenolic laminated sheet etc complete all as specified and directed. Make : Anchor/Kolors/Crabtree/SSK
M/s SK Traders
jitendra c joisar
Sagathiya Builders
suvidhiconstruction
High Tech Consruction
EVEREST BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .