| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | L1 | Accepted-AOC Deducts after sch of credit | |
| 2 | L2₹6.2 L+₹80,328 (14.8%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹6.5 L+₹1.1 L (20.7%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | Rejected-Technical PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | - | Rejected-Technical Not Enlisted in required category as per NIT. |
Tender Value
Refer Docs
EMD Value
₹19,720
Closing Date
12 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Nagtalao
Military Engineer Services AGE I Nagtalao Pin 342037 CO 56 APO
Periodical repair maintenance of summer and cooling appliances and other miscellaneous works at Nagtalao under AGE I Nagtalao
2021_MES_423608_1
8139/20-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Nagtalao
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE I Nagtalao
₹19,720
Yes
17 May 2021
19 Feb 2021
15 Mar 2021
19 Feb 2021
12 Mar 2021
26 Feb 2021
60 days
Amount
Material and labour for painting to old steel surfaces of Desert cooler of Air flow capacity up to 5000 Cu M/hr with two coats of synthetic enamel spray paint hammer tone paint of approved colour make Dulax , asian paint (Apcolite), Nerolac,over one coat of red oxide on external surface and two coats of anti corrosive rubber paint inside the Body tank and side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler. and writing of MES No in 25mm height etc complete all as specified and directed by Engineer-in-Charge at site and office yard.
M&L for replacement of copper conductor cable 0.75 Sqmm 3 core not less than 3 mtrs long with plug top 5 Amp suitable for desert cooler (Make FINOLEX/HAVELLS/POLYCAB).
Replacement of PVC water distributor with PVC pipe and PVC pipe elbow complete all as directed by EIC.
M&L for replacement of Fan blade of desert cooler heavy duty HDPE suitable for 4000/5000 CFT cap complete all as directed by EIC.
M&L for Water lifting submersible pump suitable for desert cooler as per existing capacity. (Make : Khaitanl/CG)
M&L for taking down existing unserviceable fan motor from desert cooler and including replacement of wornout winding, bushes and bearing etc and testing complete, refixing and connecting complete all as directed by EIC.
Supply & Fix in repairs wood wool Pad (set of three), minimum weight 0.80 kg, inside panels of desert coolers complete all as directed by EIC.
Supply & Fix in repairs capacitor 4 MFD for fan motors of desert cooler (Make : EPCOS/SYSCAP/ASIAN)
Replacement of following rusted and leakaged water tank of Desert cooler of 4000/ 5000 CUM/hr capacity as required at site.
-Ditto- as per above item no.10 but Side lags
-Ditto- as per above item no.10 but Top cover
-Ditto- as per above item no.10 but Fronnt grill with connection strip
-Ditto- as per above item no.10 but Supporting legs with frame and clips incl nuts & bolts of exhaust fan.
Material and labour for servicing /overhauling of split type AC unit cap. 2 Ton incl. painting to outer cover and components with two coats of synthetic enameled paint of approved colour as directed with writing of serial No SM/MES No as directed) and complete incl. following:- (a) Cleaning and descaling of condensing unit and cooling coil with caustic soda mixed water and air blower and taking out all dirt /sludge etc. all as directed by Engg-in-charge. (b) Greasing / oiling of blower fan motor. (c) Checking of refrigerant on standing pressure. Note- Topping of refrigerant will be measure and paid in respective item. (d) Replacement of remote cell/battery, replacing worn out rubber, bushes/rubber packing reactifiaction of unusual noise. (e) Replacement of minor parts such as nut/bolts washers etc and reasembling of complete AC including testing for smooth functioning complete all as directed by EIC.
-Ditto- as per above item no.15 but split type AC unit cap. 1.5 Ton.
-Ditto- as per above item no. 15 but window type AC unit cap.2 Ton.
-Ditto- as per above item no.15 but window type AC unit cap 1.5 Ton.
M&L for finding out leakage with the pressure testing of the condensor/cooling unit/ compressor of window type/Split type AC of 2.00 Ton cap including dismantling the same for recharging and stop leakage by brazing/soldering including charging the R-22 gas to required level and testing the AC for the entire satisfaction of EIC.
-Ditto- as per above item but split type AC unit cap. 1.5 Ton.
M&L for removing the defective compressor Sealed unit 2.00 Ton Capacity window type Air conditioner after cutting copper tubing without any damage to existing other parts, replacing compressor with new sealed unit (compressor) of same make complete with erection of compressor in same location with suitable base,jointing of copper refrigerant pipe line,charging of gas to required level,leakage testing etc. including testing for smooth functioning. NOTE : (i)The rate quoted by the contractor shall be inclusive of all charges like transportation,fittings,etc. complete with necessary guarntee period including oiling and R-22 gas charging, testing etc.complete.
-Ditto- as per above item No 21 but window type AC unit cap. 1.5 Ton.
-Ditto- as per above item No 21 but split type AC unit cap. 2 Ton.
-Ditto- as per above item No 21 but split type AC unit cap. 1.5 Ton.
M&L for replacement of blower and bush of Split type AC cap 2.00 Ton Make as per the sample existing at the ground.
M&L for replacement of blower and bush of Split type AC cap 1.5 Ton Make as per the sample existing at the ground.
M&L for replacement of blower and fan blade of window type AC cap 2.00 Ton Make as per the sample existing at the ground.
M&L for replacement of blower and fan blade of window type AC cap 1.5 Ton Make as per the sample existing at the ground.
Supply and fix in repair of split AC indoor unit blower motor 1.5 ton as per exisiting make all as per directed by Engr-in-Charge
Supply and fix in repair of split AC indoor unit blower motor 2 ton as per exisiting make all as per directed by Engr-in-Charge.
Rewinding of window/Split AC out door motor with replacement of shaft and bush complete all as per directed by Engr-in-Charge
Repair of PCB for split AC 2 Ton complete all as per directed by Engr-in-Charge
Repair of PCB for split AC 1.5 Ton complete all as per directed by Engr-in-Charge
Repair of PCB for window AC 2 Ton complete all as per directed by Engr-in-Charge
Repair of PCB for window AC 1.5 Ton complete all as per directed by Engr-in-Charge
Supply and fix in repair of PCB with display for split AC 1.5 Ton as per exisiting make all as per directed by Engr-in-Charge.
Supply and fix in repair of PCB with display for split AC 2 Ton as per exisiting make all as per directed by Engr-in-Charge.
All as per Item No 39 above but for split type AC 2.00 Ton capacity.
All as per Item No 39 but for split type AC 1.50 Ton capacity.
S&F in repairs of running capacitor, 45+5% MFD suitable for 2.00 Ton capacity window/split type AC of approved make.
S&F in repairs of running capacitor, 45+5% MFD suitable for 1.5 Ton capacity window/split type AC of approved make.
Supply and fixing starting capacitor clip type of cap. 80-100 MFD,440 volts 50 Hz for 2.0 TR window type air conditioner (Make:- Kell/Tesla/Sharda/Escop)
Supply and fixing starting capacitor clip type of cap. 80-100 MFD,440 volts 50 Hz for 1.5 TR window type air conditioner (Make:- Kell/Tesla/Sharda/Escop)
Supply and fixing starting capacitor clip type of cap. 100-120 MFD,440 volts 50 Hz for 2.0 TR Split type air conditioner (Make:- Kell/Tesla/Sharda/Escop)
Supply and fixing starting capacitor clip type of cap. 100-120 MFD,440 volts 50 Hz for 1.5 TR Split type air conditioner (Make:- Kell/Tesla/Sharda/Escop)
S&F in repairs of Thermostat suitable for split/window type AC 2.00 Ton capacity of approved make.
S&F in repairs of Thermostat suitable for split/window type AC 1.50 Ton capacity of approved make.
S&F in repairs of relay suitable for window/split type AC 2.00 Ton capacity of approved make.
S&F in repairs of relay suitable for window/split type AC 1.50 Ton capacity of approved make.
M & L for replacement of chocked copper tube of size 1/4" of split type AC complete all as directed by Engr-in -Charge.
M & L for replacement of chocked copper tube of size 1/2" of split type AC complete all as directed by Engr-in -Charge.
M &L for insulation coating/PVC air bubling insulation of circular dia to copper tube to up keep the required temperture and over all protection to copper tubing of size 1/4" or 1/2" complete all as directed by Engr-in-Charge.
Material & Labour for replacement of drain out pipe of split type AC complete all as directed by Engr-in-charge and taking out the unserviceable pipe from side wall and replace with new pipe complete all as per existing.
M&L for taking out water Cooler from site of any cap.and make for servicing incl. cleaning cooling tank and condencing coil with C shine cemical mixed water, taking out all dirt , sludge deposited, incl. oiling / greasing of condensing fan motor , checking of refrigerant on standing pressure, rectification of unusual noise, replacement of minor parts such as nut/bolt washers etc, all as directed
M&L for shifting of window/split AC from one location to another suitable location as and where specified by engineer-in-Charge
M & L for spray painting of outer cover with 2 coats of synthetic enameled paint of approved colour with writing of serial No SM/MES No. and reinstalled the water cooler in position complete all as directed by EIC.
M&L for replacement of condensor unit complete suitable for 40/80 Ltr/hr cap water cooler (as per existing make)
M&L for replacement of defective sealed compressor unit of 80 Ltr/hr cap water cooler. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make in functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete.(as per existing make)
M&L for replacement of defective sealed compressor unit of 40 Ltr/hr cap water cooler. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make in functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete.(as per existing make)
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of water cooler of 40/80 Ltr/hr cap including dismantling the same for recharging and stop leakage by brizing/soldering including charging the R-134A gas to required level and testing the water cooler for the entire satisfaction of EIC.
Material and Labour for Replacement of starting capacitor 40/60 Mfd oil filled 240 volt AC Supply for water cooler Make ; Tesla
Material and Labour for Replacement of running capacitor of 10/15 Mfd oil filled for water cooler Make: Asian/ Atlas/Epcos/SPAN/Sharda
S&F in repairs of over load protector suitable for water cooler 40/80 Ltr/hr capacity of approved make.
S&F voltage stablizer for automatic operation, single phase indoor wall mounted type & designed for input variation between 130 V to 285 V with output voltage stablized at 230 V with built in thermal overload protection, low & high voltage cut-off protection, latest IC technology, inteligent time delay system and capacity 4.0 KVA.
M&L for replacement of condenser Fan motor of water cooler 40/80 Ltr/hr capacity as per the sample existing at the ground and testing complete.
M&L for replacement of fan blade of water cooler as per the sample existing at the ground.
S&F in repairs of Thermostat suitable for water cooler 40 Ltr/hr capacity of approved make.
Material and Labour for brass float valve 15 mm bore with PVC float, ball I.S.I Marked complete with check nut /socket/GI nipple directed by Engineer -In -charge
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of refrigerator of 165/215 Ltr cap including dismantling the same for recharging and stop leakage by brizing/soldering including charging the R-134A gas to required level and testing the refrigerator for the entire satisfaction of EIC.
vinayandsons
J AND T Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .