Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹37.7 L+₹3.9 L (11.5%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹38.7 L+₹4.9 L (14.4%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹41.3 L+₹7.5 L (22.2%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹44.9 L+₹11.0 L (32.7%)Rejected-Finance | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
27 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Tezpur
HQ CWE TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
SPL REPAIRS/REPLACEMENT OF HT (11 KV) OVERHEAD LINE TO AERIAL BUNCH CABLE AT CERTAIN AREA UNDER GE (S) TEZPUR
2021_MES_464011_1
CWE/TEZ(S)/T-14 of 21-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (S) Tezpur
as per tender docus
8 documents required · 8 mandatory
₹500
GE(S) Tezpur
₹96,000
Yes
25 Oct 2021
30 Jul 2021
30 Aug 2021
30 Jul 2021
27 Aug 2021
13 Aug 2021
75 days
Amount
Excavation in trenches n.exc 1.5m wide and n.exc and 1.5 mtr in depth getting out in in soft/loose soil all as specified and directed by Engineer-in-charge.
All as per item No. 1 above but exceeding 1.5 mtr and not exceeding 3 mtr in depth.
Returning and filling including spreading, leveling, watering and well ramming in layer n.exc 25 CM thick in soft/loose soil all as specified and directed by Engineer-in-charge.
Removing excavated material to a distance not exc. 50 mtrs and deposting where directed at a level not exceeding 1.50mm above the starting point all as specified and directed.
Supply and laying natural river sand as cushioning of cables, including spreading and punning down all as per clause No 3.21 of SSR part -I complete all as specified and directed by Engineer-in-charge and directed by Engineer in charge Note : punned thickness will only be measured for payment purpose.
Supplying and laying reinforced precast concrete cable cover, but class HV, Type 1, flat, size 300mmx 180mm x 40mm complete all as specified and directed.
Dismantling of Steel tubular/railing type poles / struts any size complete all as specified and directed..
Dismantling ACSR conductor including all its accessories complete all as specified and directed.
Supply,Laying ,testing, and commissioning size 3x95 sqmm cross-sectional area XLPE insulated, screened, PVC bedded, galvanised steel strip armoured heavy duty electric cable with aluminium conductor 11000 volts grade, in tranches / fixing on wall by saddel/ fixing on poll / drawn through GI pipes all as specified and directed.
Supply,Laying ,testing, and commissioning size 3x95 sqmm cross-sectional area Aerial Bunch Cable with H4 grade Aluminium, with extruded semi conductor screen, XLPE insulation, Insulation screen Non-metallic extruded semi conducting layer, insulation screen metallic applied helically over the non metallic layer, sheath PVC type ST2, with messanger conductor of one run of ACSR of nominal dia not less than 70 sqmm , heavy duty 11000 volts grade, fixing on poles including all its hardware accessories such as suspension hook, suspension clamp, rubber complete all as specified and directed.
M & L Steel tubulr swaged poles complete with cast iron base plate, finial tapr plug, bolts, nuts and screws as specified type 410 SP-55, 11 metres long complete all as specified and directed.
M&L for cement concrete type D2, 1:4:8 (using 40 mm graded sto agg.) in foundations, filling and mass concrete complete all as specified.
M&L for cement concrete type C1 1:3:6 (20mm graded aggregate) in or mud stops, rounded or chamfered on edges etc all as specified and directed
M&L for cement concrete type B0, 1:2:4 (using 12.5 mm graded sto agg.) for coping above ground level of steel electric pole concrete complete all as specified.
S & F composite polymer type post insulator for 11 KV Aierial Bunch cable with channel with all connecting accessories for fixing end jointing kit complete all as specified.
Supply and fix Cable jointing kit for 11KV grade cable for Outdoor End termination heat shrink type complete with Jointing material and acceesseries suitable for 3 core are XLPE armoured at conductor cable of size 95 sq mm all as specified & directed by Engineer-in-charge. make- DENSON/Raychem/3M-M-Seal
Supply and fix Cable jointing kit for 11KV grade cable for Outdoor End termination heat shrink type complete with Jointing material and acceesseries suitable for 3 core Aierial Bunch cable of size 95 sq mm all as specified & directed by Engineer-in-charge. Make- DENSON/Raychem/3M-M-Seal
Material and labour for stay assembly complete with accessories as shown in electrical plate No. - 1, with and including stay road rod 20 mm dia and galvanised stay of size 7/2.24mm of required length, GI wire 7/3.15 mm etc complete all as specified and as directed by Engr - in - Charge. Note : Loop type insulator, excavation, earth work and concrete to be measured and paid seperatly.
M & L Loop type insulator, vitreous porcelain, brown Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed.
M & L for GI Earth wire of dia 4mm including fixing accessories complete all as specified and directed.
M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge. Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GI water pipe including GI protection pipe 40mm dia light grade for earth strip etc. 2. The cost of earth pit is deemed to be included in the unit rate.
M & L Composite Polymer Lightning arresters expulsion type complete with all fittings, chanells transmission class, discharge capacity 65 kilo amp suitable for 11 KV to fix it on the Pole with continuity conductor upto earth terminal including taking down unsv LA complete all as specified and directed.
M & L Composite Polymer Air Break switch gang operated Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating 200 amps fit for 11 KV with necessary chanells for fixing the switch and handle with all accessories all as specified and directed.
Taking down Insulators Polymer / Porcelein complete all as specified and directed.
NOTES: 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
PURBANCHAL BUILDERS
M.S. Construction
KUNDAN ENGINEERS AND BUILDERS
M/S GOSWAMI ENGINEERING
MAHANTA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .