| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC | ₹2.3 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹2.3 Cr+₹1.3 L (0.57%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹2.3 Cr+₹1.3 L (0.57%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹2.4 Cr+₹12.6 L (5.53%)Rejected-Finance H NO 6 1ST FLOOR P B ROAD SUHAGPUR REBARARI GUWAHATI 08 | GUWAHATI | ₹2.4 Cr+₹12.6 L (5.53%) | L3 | Rejected-Finance Not being lowest |
| 4 | Rejected-Technical THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | - | - | Rejected-Technical Not meets the eligibility criteria as per NIT |
| Sl No | Description | Qty | Unit | Shree Ayyappa Engineering L2 | RS COOLING APPLIANCES L3 | HVAC Engineering Co L1 |
|---|---|---|---|---|---|---|
| 1.00SPECIAL REPAIRS (B/R ITEMS) | ||||||
| 2.00 | Taking down any type of false ceiling for AC duct in repair/ replacement work and refixing the same after completing the duct work including all required accessories and make it good complete all as specified and as directed.
Note : (i) Any damages made to false ceiling during execution of the above, the same may be repaired/replaced by the contractor without any additional cost.
(ii) Cost of additional materials required for making it good as per existing surface deemed to include in the quoted rate. | 500 | Sqm | 180 ₹90,000 Lowest | 200 ₹1,00,000 | 200 ₹1,00,000 |
| 3.00 | S&F anodised aluminium snap grid frame work for false ceiling, size of grip 605x605mm including necessary notching and prepared holes etc complete all as specified and as directed. | 200 | Sqm | 540 ₹1,08,000 | 1,000 ₹2,00,000 | 500 ₹1,00,000 Lowest |
| 4.00 | S&F hangers 6mm dia, GI 9 ( up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G I flat 40x3mm size 60mm long and and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and as directed. | 200 | Sqm | 180 ₹36,000 Lowest | 250 ₹50,000 | 500 ₹1,00,000 |
| 5.00 | M & L for providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufactures instructions including necessary scaffolding etc complete all as specified and as directed. | 200 | Sqm | 372 ₹74,400 Lowest | 500 ₹1,00,000 | 500 ₹1,00,000 |
| 6.00 | Dismantling of wall & ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets/aluminium frame works complete all as specified and as directed. | 200 | Sqm | 135 ₹27,000 | 200 ₹40,000 | 100 ₹20,000 Lowest |
| 7.00SPECIAL REPAIRS (E/M ITEMS) | ||||||
| 8.00 | Dismantling and taking down of existing old unserviceable central type AC plant of capacity 2x120TR including all connected accessories such as compressor, AHU units, Ducts, Valves, pump sets along with pipelines, condensers & LT panel boards with cables including necessary T &P, scaffolding, and making good disturbed portions for matching with existing and depositing the plants with MES No such as Chiller, Pumps/ Motors etc to MES Store Yard and all other accessories without MES No as credit to contractor complete all as specified and directed.
Note :- Any accessories required to be removed during the dismantling units shall be repaired /replaced to the existing shape as per site requirement and as directed by EIC .The quoted rate shall deemed to be inclusive of cost for breaking of wall / door frame/ windows if required and making good to the existing shape complete all as specified and as directed | 1 | Each Job | 80,000 ₹80,000 | 1,50,000 ₹1,50,000 | 50,000 ₹50,000 Lowest |
| 9.00 | Design ,Supply, installation, testing, commissioning of 120 TR capacity water-cooled flooded type chiller with Hermetic/semi Hermetic sealed screw compressor capable of working with refrigerant R134A or 410A complete with shell and tube condenser, flooded type shell and tube evaporator provided with thermal insulation using 13mm thick closed cell class 'O' elastomeric nitrile rubber foam sheet, flow switches at condenser and evaporator water outlet, the first charge of refrigerant and oil, Microprocessor based control panel with all safety devices and interlocks, Chiller mounted on MS frame with vibration isolator, AHRI certified conforming to the following technical specification in all respect and as directed.
Make: Bluestar /Carrier/Daikin
Evaporator flow rate:- 18.89 LPS (+/-5%)
Chilled water in Temperature:- 12.22 Deg C
Chilled water out temperature:- 7 Deg C,
Condenser water in Temperature:- 29.44 Deg C ,
Condenser water out Temperature:- 34.61 Deg C
Cooler/Evaporator fouling factor:- 0.0001 h.ft2.F/Btu
Condenser fouling factor :- 0.00025 h.ft2.F/Btu,
Power at full load (kW/TR):- </=0.6206, IPLV (kW/TR) :- </= 0.477
Note: Chiller shall deliver a minimum of 120 TR at the above conditions. | 2 | Each Job | 27,00,000 ₹54,00,000 Lowest | 28,50,000 ₹57,00,000 | 36,00,000 ₹72,00,000 |
| 9.01Note for item No. 9 :- (i)The AC plant and other accessories shall be commissioned by OEM. (ii)The contractor shall submit a certificate from the OEM confirming that the entire AC plant work shall be got installed through them/ their accredited agencies duly incorporating their recommended make. For this the contractor shall obtain the certificate for this from the OEM branch office located in Kochi. (iii) If the required capacity is not available, the next higher capacity shall be provided by the contractor, and the cost for the same is deemed to be included in the cost. (iv) The tenderer shall visit the site, check the site conditions and carry out necessary heat load calculations before quoting the tender so as to assess & incorporate any changes needed to install the plant in the given location. (v) First charge of refrigerant, compressor oil, lubricants etc and maintaining it at desired level even when leakage occurs during defect liability period is deemed to be the responsibility of the tenderer. (vi)Before commencement of the work contractor shall obtain complete design details of AC Plant including drawing from OEM branch office located in Kochi and submit the OEM vetted drawing for approval of accepting officer duly supported with all relevant specifications of each components of AC plant . | ||||||
Tender Value
₹2.5 Cr
EMD Value
₹3.2 L
Closing Date
8 Sept 2025, 6:00 pmClosed
CHIEF ENGINEER (NW) KOCHI
CHIEF ENGINEER NAVAL WORKS KOCHI MILITARY ENGINEER SERVICE NAVAL BASE POST KATARIBAGH KOCHI-682004
SPECIAL REPAIRS FOR REPLACEMENT OF 02 X 120 TR AC PLANT AND CONNECTED ITEMS BUILDG No P-148 AT NAY NAVAL BASE KOCHI
2025_MES_724419_1
891090/E8
Open Tender
Electrical and Maintenance Works
Item Rate
1000 days
Kochi
Class B category c(i)
8 documents required · 8 mandatory
₹2,000
GE(NS) Kochi
₹3.2 L
Yes
21 Oct 2025
4 Aug 2025
10 Sept 2025
4 Aug 2025
8 Sept 2025
25 Aug 2025
5 Aug 2025 - 18 Aug 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .