Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC MADARAT MASJIDPARA BATTALA BARUIPUR DIST SOUTH 24PARGANAS 743610 | BARUIPUR | SOUTH 24 PARGANAS | WEST BENGAL | 743610 | ₹3.2 Cr | L1 | Accepted-AOC L1 bidder awarded |
| 2 | L2₹3.3 CrRejected-Finance VILL LAKSHMINARAYANPUR P O BANSHRA P S CANNING DIST SOUTH 24 PARGANAS PIN 743363 | CANNING | SOUTH 24 PARGANAS | WEST BENGAL | 743363 | ₹3.3 Cr | L2 | Rejected-Finance Not L1 |
| 3 | L3₹3.4 CrRejected-Finance | ₹3.4 Cr | L3 | Rejected-Finance Not L1 |
| 4 | Rejected-Technical VILL BAGARIA P O B BAGARIA P S KULPI DIST SOUTH 24 PGS PIN 743332 | BAGARIA | SOUTH 24 PARGANAS | WEST BENGAL | 743332 | - | - | Rejected-Technical Document regarding Elect. Work as per Cl. No. 3 nos. found and uploaded credential is not compliant with NIeT |
| Sl No | Description | Qty | Unit | LIBERTY CONSTRUCTION L3 | SAMRAT ENTERPRISE L1 | RAJA CONSTRUCTION L2 |
|---|---|---|---|---|---|---|
| 1.00 | TOTAL | 1 | Nos | 3,43,11,122 ₹3,43,11,122 | 3,18,67,810 ₹3,18,67,810 | 3,29,25,768 ₹3,29,25,768 |
Tender Value
Refer Docs
EMD Value
₹5.8 L
Closing Date
20 Jan 2026, 1:00 pmClosed
SR. SE SC PWD
76 Dr. Deodar Rahaman Road 2nd floor Lake Gardens KOLKATA 700033
Restoration and conservation work of Hamilton Bungalow along with water bodies at Gosaba, South 24 Parganas during the year 2025-26
2025_WBPWD_977474_2
WBPWD/SSE/SC/NIeT-16/2025-2026
Open Tender
CIVIL WORKS
180 days
South 24 Parganas
Please refer Tender documents.
4 documents required · 4 mandatory
₹5.8 L
Yes
Office of the SE SC PWD
10 Mar 2026
20 Dec 2025
22 Jan 2026
7 Jan 2026
20 Jan 2026
9 Jan 2026
8 Jan 2026
TOTAL
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
PART A: Facelifting of existing old Hamilton Banglow: TEMPORARY SUPPORT SYSTEM M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.(For structural work)(To be used for existing damaged column repair works only).
TAKING OUT DAMAGED WOODEN SECTION Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately),(b) Above area 2.5 sqm
RESTORATION OF WOODEN BEAMS & COLUMN Dressed wood work in post , plate , battens . etc. fitted & fixed complete (excluding the cost of bolts only, but including the cost of nails, screws etc.) (The quantum should be corrected upto three decimals. (i) Sal : Siliguri.
Wooden eaves board as per design, fitted and fixed complete: In ground floor (iii) Ornamental eaves board (Badam/Gamar/Champ/Hallak) (b) 25mm thick
Supplying, fitting and fixing 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200mmX 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density > 940 kg/m3 substrate core over a rasin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture (< 8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer 'T' profile etc. wherever required and preparation of base including all other incidental works as per direction & satisfaction of Engineer in charge. Cost of Laminate Floor Accessories only (Skirting,End edge, T- moulding,Reducer )shall have to be added separately, wherever required. (Note: This work should not be executed without specific permission of Superintending Engineer). ln Ground FIoor
EARTH WORK IN EXCAVATION Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a)Depth of excavation not exceeding 1.500 mm.
BRICK WORK Supplying and laying brick Khoa of ordinary bats of size (38 mmx 63 mm)of approved quality in 100 mm layer (loose) filling in gaps with small ones rammed and compact as directed true to level and grade.
Brick-on-edge floor or pavement with 1st class brick set close in cement mortar (1:6) and laid with cushion of sand below (including cost thereof) including ruled or flush pointing with cement mortar (1:4) on top.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
SHUTTERING WORK Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (b) Above 30 mm & upto 37 mm thick wooden shuttering as per decision).
CONCRETING Controlled Cement concrete grade mix with well graded stone chips (20 mm nominal size) including adequate plasticiser & excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 360 Kg of OPC [43/53 grade ] cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] With Pakur Variety M 40 Grade of Concrete
APPLYING WOOD PRESERVATIVES Removing old paint from blistered painted surface with application of soda, sajimati or any approved chemical paint remover and exposing the original surface including cleaning and thorough washing to remove all traces of the removing agent including taking out shutters and refixing the same where necessary.
Painting with ready mixed Black Japan of approved make and brand including smoothening surface b) Two coats
APPLYING EPOXY PRIMER & PAINTING Polyurethane Polishing to woodwork with required colour as approved by Engineer-in-Charge with preparing surface including scaffolding and hire charges of compressor machine including cost of filler and hardener material such as P. U. Sealing, P. U. Top coat (Matt/Glossy), Thinner, Spirit etc. and inclusive of all operation, material and labour complete as per direction of Engineer-in- Charge.
RESTORATION OF ROOF Strong bamboo frame work (for thatched roofing) with 75 mm. dia full bamboo rafters spaced at 350 mm. centres and tied with transverse bracings at 380 mm. spacing (each bracing consisting of a pair of quarter bamboo, one at top and the other at the bottom of the rafters) fitted and fixed in position complete.(for removing of existing damaged roof sheets).
Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge.
Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.and stacking the material at site as directed.
Supplying, fitting & fixing Industrial Troughed Aluminium sheet (excluding the supporting frame work) of approved make & brand in alloy 3105 conforming to IS: 1254-1991 fitted and fixed with 75 mm & 25 mm Self tapping screw , EPDM Washer 16 mm dia & 3 mm th washer etc complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work) (Aluminium sheet to be supplied by contractor)
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required
Polyurethane Polishing to woodwork with required colour as approved by Engineer-in-Charge with preparing surface including scaffolding and hire charges of compressor machine including cost of filler and hardener material such as P. U. Sealing, P. U. Top coat (Matt/Glossy), Thinner, Spirit etc. and inclusive of all operation, material and labour complete as per direction of Engineer-in- Charge.(On Roof surface)
POLISH WORK (INTERIOR & EXTERIOR) French polishing to wood work including preparing surface (ordinary gloss) (b) On old French polished surface including complete removal of the old polish.
Misc. Items of works. Plain and finished timber planks in partition, shelves etc. fitted and fixed complete as per design (butt joints) in ground floor. (i) 12mm thick planks. (b) Sishu / Champ / Badam / Gamar / Bhola /ogra / Hallak
Labour for wood work in sawing from old timber to sizes as required for making (Payment to be made on quantity of finished work): (a) Beams of smaller length but of same section.
Add extra over correspnding item G(17) and C(8) (i) Half lap joint.
Supplying, fitting & fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge. [At Ground Floor]iii) Mural aligned/ CAD Design Type
Supplying Laminate Floor Accessories (Skirting, End edge, Tmoulding, Reducer ) to 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200mmX 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density > 840 kg/m3 substrate core over a rasin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than 1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture (< 8%), grease etc. complete in all respect as per direction & satisfaction of Engineer in charge. Cost of labour charge for fitting & fixing of Laminate Floor Accessories only (Skirting,End edge, Tmoulding, Reducer )shall have to be added separately, wherever required. (Note: This work should not be executed without specific permission of Superintending Engineer). ln Ground FIoor: Catagory: Normal/High Footfall
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixedon the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) (b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating)
PART B: Hardscaping Work including Pathways: Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary).
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (i) Depth of excavation not exceeding 1,500 mm.
(ii) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) - (i) With earth obtained from excavation of foundation.
(ii) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth.
Filling in foundation or plinth by Silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Hire and labour charges for shoring work (including necessary close plank walling, framing, Eucalyptus/Jhou bulla piling, strutting etc) complete as per direction of the Engineer-in-charge for foundation excavation (vertical surface are in contact with supported earth is to be measured.) (This item should be executed on specific direction of the Enginner in charge) a) Depth upto 1.5 m
Bailing or pumping out water from foundation trenches.
Extra over the corresponding item of earth work for removing semi liquid mud or slushy earth by iron pans, buckets etc.
Removal of rubbish, earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes - with Pakur Variety shote chips.
Controlled Cement concrete with well graded stone chips (20mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] - M25 Grade with Pakur Variety stone chips a) In Ground Floor & Foundation
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) - 12 mm thick approved quality ply board shuttering in any concrete work with Steel Props a) In Ground Floor & Foundation
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction - with Tor Steel of SAIL/TATA/RINL make. a) In Ground Floor & Foundation
Brick work with 1st class bricks in cement mortar (1:6) a) In foundation and plinth
b) In Ground Floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. a) In Ground Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar - 20mm thick Plaster (External) a) In Ground Floor
ii) With 1:6 cement mortar - 15mm thick Plaster (Internal) a) In Ground Floor
(iii) With 1:4 cement mortar - 10mm thick Plaster (Ceiling) a) In Ground Floor
Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc. Note:Cement 0.152 cu.m per100 sq.m.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete - For roof truss works - Span up to 12 Mtr
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work) - In Roof - With 0.5 mm thick sheet
Supplying and laying true to line and level High Grip, Scratch resistant, Neutral to UV rays, Full Body Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr's hardness > 7.0, Staining resistance: Class1, Water Absorption E < 0.5%] & MOR > 35N/sq.mm and Breaking strength >1500 N for Outdoor area of building e. g. Gang-way, Corridor, Driveway, Parking lots, Courtyards, Sloping ramps, Entrance lobbies, Patios, Portico etc. set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturer's specification and direction of Engineer-inCharge. In Ground Floor: Sizes-300 mm x 300 mm x10 mm
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. (c) 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone,commercial & office complex,tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course including cost of sand for sand bed but excluding cost of base ,sub-base course & subgrade preparation.) Coloured Decorative
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 450 mm x 350 mm x width 150 mm at bottom with bevelled nosing at top) of cement concreat M20 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in-Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor - Grill weighing above 16 Kg./sq.mtr and above - In Ground Floor
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC - In Ground Floor: One Coat a) In Ground Floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer - In Ground floor (Two Coat) : Super Protective 100% Acrylic Emulsion. a) In Ground Floor
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary a) On steel or other metal surface - With super gloss (hi-gloss) - Two coats (with any shade except white)
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures. [water proofing as per item no 60 and non toxic paint as per item NO 59 (b) of Section 'C' ]
Laying of a geotextile filter between pitching and embankment slopes on which pitching is laid toprevent escape of the embankment materialthrough the voids of the stone pitching/cementconcrete blocks as well as to allow free movementof water without creating any uplift head on thepitching.
Providing and laying Pitching on slopes laid overprepared filter media including boulder apron laiddry in front of toe of embankment complete as perdrawing and Technical specifications. - I. Stone/Boulder
Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors, of size EN-4 for leaf width upto 950/ 1100mm weighing maximum 60/ 80 kgs, CE certified, marked & conforming to EN 1154-2003 of approved quality of reputed brand, complete as per direction & satisfaction of Engineer-in-Charge. for leaf width upto 950mm
Designing of different customised curved & plain metal craft by laser cutting on different metal sheets of varying thickness for special architectural application as facade/wall panel/ceiling decoration as per design, drawing or as approved standard by the Engineer-in-charge including transportation. (Mode of measurement - linear /peripheral dimension of laser cut area) Mild Steel Plate, Aluminium & Stainless Steel i) 2.0mm thick
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel ( Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges e.g. VAT, Labour cess etc complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of AC. (b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating )
PART C: Landscaping work of the compound: LAND DEVELOPMENT AND BEAUTIFICATION : Supplying and stacking sludge (adequate for Horticulture work) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. (Sludge measured in stack will be reduced by 8%).
Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 ( 8 parts of stacked volume of earth after reduction by 20%, one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary watering and finally fine dressing, levelling etc., including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50m lift upto 1.5m complete. This includes supply of labour, tools & plants including materials
Planting of trees/ plants in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
PART D: Toilet Block (Civil Work): Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (a) With earth obtained from excavation of foundation
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand (payment to be made on measurement of finished quantity). (B) Do - by fine sand
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
Pre-Constructional Anti-termite measures: (c) Antitermte treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrefos emulsifiable concentrates ( 1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surfac before sand bed or sub-grade is laid. Hole upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diaetre mild steel rod on the surface to facilate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in ^.2.1. of code IS-6313 (part -II) 1981. ( Mode of measurment will be plan area of plinth treated.)
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. with Pakur Variety shote chips. Ground floor
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade with Pakur Variety shote chips. Ground floor
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (f) 25mm. to 30mm. shuttering without staging in foundation etc.
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (i) Tor steel/Mild steel (a) For works in foundation, basement and upto roof of ground floor / upto 4m. TATA/SAIL/RINL
Brick work with 1st class bricks in cement mortar (6:1) (a) In foundation and plinth
(b) In superstructure, ground floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in Ground Floor.
25 mm. thick damp proof with cement concrete (1:1.5:3) (with graded stone aggregate 10 mm. normal size) and painting the top surface with a coat of bitumen [VG.40 ] using 1.7 kg. per sq.m. including heating the bitumen and cost and carriage of all materials complete. [ Bitument to be supplied by the Agency]
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 6:1 cement mortar (b) 20 mm. thick plaster(Internal) in Ground Floor.
(c) 15 mm. thick plaster in Ground Floor.
(ii) With 4:1 cement mortar (c) 10 mm. thick plaster(Internal) in Ground Floor.
Labour for chipping of concrete surface before taking up plastering work in Ground Floor.
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirrorfinish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineerin- Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (a) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick)
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (C) Floor With Polymerised Adhesive and Epoxy grout pointing including spacer- 2 mm ( When Tiles are laid over existing hard ready surface) (b) Area of each tile above 0.09 Sq.m [using adhesive 4.5 mm thick] (i) Coloured decorative (D) Wall With Polymerised Adhesive and Epoxy grout pointing including spacer- 2 mm ( When Tiles are laid over existing hard ready surface) (b) Area of each tile above 0.09 Sq.m [using adhesive 4.5 mm thick] (i) Coloured decorative .
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. (i) 66mm x 90mm Ground floor
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. (i) 32 mm thick Ground floor
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. Ground floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (a) 40mm X 6mm, 250mm Length
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (viii) 100mm. X 75mm. X 3.50mm.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (x) 300mm long x 12mm dia. Bolt
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (hexagonal/round rod) (vi) 150 mm grip x 10mm dia rod.
Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement ........... care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N:300 (longitudinal), 200 (transverse)
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : With super gloss (hi-gloss) - (b) On steel or other metal surface : (iv) Two coats (white any shade except White)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats Ground floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion. Ground floor
Supplying, fitting & fixing UPVC pipes A-Type and fittings conforming to IS: 13592 - 1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materials (Spun Yarn, Valamoid / Bitumen / M-Seal etc.) Complete. A) UPVC Pipes : (iii) 160 mm. Dia.
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) ii) Solvent based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Two coats)ii) Luxury Quality
PART E: Toilet Block (Sanitary & Plumbing): Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work (c) (ii) 25 mm dia. medium quality
(d) (ii) 32 mm dia. medium quality
ii) 40 mm dia. medium quality
(f) (ii) 50 mm dia. medium quality
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (b) For Concealed Work (ii) CPVC Pipes Class-2,SDR-13.5 15 mm
(b) For Concealed Work (ii) CPVC Pipes Class-2,SDR-13.5 25 mm
Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately) (vi) 50 mm dia. medium quality
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). iv) 50 mm dia
(v) 40 mm dia
vi) 32 mm dia
(vii) 25 mm dia
Supplying, fitting and fixing bib cock or stop cock. (a) (ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
Supplying, fitting and fixing shower of approved brand and make. (b) Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand).
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing shower of approved brand and make. (c) Chromium plated Hand shower 70mm dia Round Shape Single flow with Flexible Tube & fittings (Equivalent to Code No. ESH-5512 & Model- Tropical/Sumthing Special of ESSCO or similar)
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia (ii) 450 mm long
(iii) 600 mm long
Supplying, fitting & fixing Cast iron soil pipe only conforming to I.S. 3989/ 2009 and I.S. 1729/2002 with bobbins, nails etc. including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (Measurement will be made along the center line of the total pipe line in fitted condition including specials,payment for specials & Painting will however be paid seperately). (b) With lead caulked joints. (ii) 100 mm dia. (internal)
Supplying, fitting & fixing Cast iron single branch equal with door conforming to I.S. 1729/2002 including joining and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (b) With lead caulked joints (ii) 100 mm dia.
Supplying, fitting & fixing H.C.I. bend with door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (b) With lead caulked joints (ii) 100 mm dia.
Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (i) 100 mm dia.
Supplying, fitting & fixing Aluminium domical grating iii) 100 mm
Supplying,fitting and fixing cast iron 'P' or 'S' trap conformimg to I.S. 3989/ 2009 and 1729/ 2002 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately). (A) 'P' Trap iii) 100 mm
Supplying, fitting and fixing cast iron extension pipes for using in Traps only (connector) conforming to I.S.3989/2009 and 1729/2002 including lead caulked joints complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (v) 100 mm X 450 mm
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.
B) UPVC Fittings: a) Plain Tee (ii) 110 mm. Dia.
c) Bend 87.5 degree (ii) 110 mm. Dia.
d) Shoe (ii) 110 mm. Dia.
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (b) With 'S' trap
Supplying, fitting and fixing approved brand 32 mm dia P.V.C waste pipe, with PVC coupling at one end fittted with necessary clamps (iii) 900 mm
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. (i) 635 mm X 395 mm X 420 mm
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (b) Anglo Indian (ii) Plastic (hallow type) white
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pipe
Supplying, fitting and fixing 18 mm thick marble partition slab with chawk doongri marbel square cut, both sides polished with two front corners rounded and edges polished.
Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges. (ii) 600 mm X 450 mm
Supplying, fitting and fixing soap holder. (a) PTMT (Prayag or equivalent)
Supplying, fitting and fixing PTMT Smart Shelf of approved make of size 300 mm.
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (ii) 25 mm dia. and 600 mm long
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL)
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. (vi) For 200 users A) With Pakur variety. (SAIL/TATA/RINL)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL)
Open jointed stone ware pipe 100 mm dia. supplied, laid and fitted in position duly encircled all round by 150 mm thick layer jhama metal (38 mm to 50 mm size) including excavation of earth in any soil upto required depth including refilling trench,watering and ramming complete. (Cost of Jhama Metal to be paid seperately).
PART F: Guard Room: Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (a) With earth obtained from excavation of foundation
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand (payment to be made on measurement of finished quantity). (B) Do - by fine sand
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
Pre-Constructional Anti-termite measures: (c) Antitermte treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrefos emulsifiable concentrates ( 1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surfac before sand bed or sub-grade is laid. Hole upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diaetre mild steel rod on the surface to facilate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in ^.2.1. of code IS-6313 (part -II) 1981. ( Mode of measurment will be plan area of plinth treated.)
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety Ground floor
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade Pakur variety Ground floor
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (f) 25mm. to 30mm. shuttering without staging in foundation etc.
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (i) Tor steel/Mild steel (a) For works in foundation, basement and upto roof of ground floor / upto 4m. TATA/SAIL/RINL
Brick work with 1st class bricks in cement mortar (6:1) (a) In foundation and plinth
(b) In superstructure, ground floor
25 mm. thick damp proof with cement concrete (1:1.5:3) (with graded stone aggregate 10 mm. normal size) and painting the top surface with a coat of bitumen [VG.40 ] using 1.7 kg. per sq.m. including heating the bitumen and cost and carriage of all materials complete. [ Bitument to be supplied by the Agency]
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface (i) With 6:1 cement mortar (b) 20 mm. thick plaster(Internal) Ground floor
(c) 15 mm. thick plaster Ground floor
(ii) With 4:1 cement mortar (c) 10 mm. thick plaster(Internal)
Labour for chipping of concrete surface before taking up plastering work
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirrorfinish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineerin- Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (a) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick)
Providing and fixing of factory made uPVC Sliding window (White Colour) complete, (U value=1.9-1.3 W/m 2 K, flame resistant, self extinguishing, lead free) comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (±0.2 mm) duly reinforced with G.I. section 1.6 mm (±0.2 mm), wherever required. All corners of frame and sash will be fusion welded. After placing 5 mm Clear Annealed glass in the sash, uPVC glazing bead, interlock, EPDM gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window frame will be fixed to the wall with 100mm long and 8mm dia. Fasteners and after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size, of approved quality complete in all respect as per as per approved drawing & direction of Engineer-In-Charge. (Note: Profile manufacturer & Window Manufacturer must be one & same, Only manufacturer Waranty is aceptable) a) 2 Track 2 Sash window frame of size 67 x 54 mm & Sash of size 64 x 47 mm both having wall thickness of 2.3 ± 0.2 mm
b) 3 Track 3 Sash window frame of size 122 x 54 mm & Sash of size 64 x 47 mm both having wall thickness of 2.3 ± 0.2 mm
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria. (i) 66mm x 90mm
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. (i) 32 mm thick Ground floor
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. Ground floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (a) 40mm X 6mm, 250mm Length
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (viii) 100mm. X 75mm. X 3.50mm.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (x) 300mm long x 12mm dia. Bolt
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (hexagonal/round rod) (vi) 150 mm grip x 10mm dia rod.
Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement ........... care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N:300 (longitudinal), 200 (transverse)
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : With super gloss (hi-gloss) - (b) On steel or other metal surface : (iv) Two coats (white any shade except White)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats Ground floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. b) Premium 100% Acrylic Emulsion. Ground floor
Supplying, fitting & fixing UPVC pipes A-Type and fittings conforming to IS: 13592 - 1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materials (Spun Yarn, Valamoid / Bitumen / M-Seal etc.) Complete. A) UPVC Pipes : (iii) 160 mm. Dia.
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) ii) Solvent based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Two coats)ii) Luxury Quality
i) Bamboo Walling: Close Bamboo Walling made of 65mm to 75mm dia. bamboos (in single line) driven about half-length into the ground side by side, with stout stays at an interval of 1m, 3nos. of half split bamboo runner of same dia fitted and fixed with nails etc. complete as per direction. (Measurement to be taken along the length of piling after finishing the works). (iii) With bamboos of length above 2.50m and upto 3.00m
Supplying empty cement bags in good condition.
ii) Pond Railing: Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (i) Depth of excavation not exceeding 1,500 mm
Filling in foundation or plinth by Silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Controlled Cement concrete with well graded stone chips (20mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] - M25 Grade with Pakur Variety stone chips a) In Ground Floor & Foundation
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) - 12 mm thick approved quality ply board shuttering in any concrete work with Steel Props a) In Ground Floor & Foundation
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction - with Tor Steel of SAIL/TATA/RINLmake. a) In Ground Floor & Foundation
a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
PART G: SANITARY FIXTURES & FITTINGS: Note : For make of sanitary fixtures & fittings refer list of approved makes as given in technical specifications. These makes / models are for identification only & final make/ model to be as directed by the Architect/Owner. Suppling, fitting and fixing Wall mounted water closet of white glazed vitreous chinaware of approved make and brand in position complete with necessary nut and boalts (Equivalent to Code No. 20061 or 92065 & Model Studio or Rubbic of Hindware or equivalent.) (This item to be executed on specific permission of Superintending Engineer)
Supplying, fitting and fixing concealed cistern of approved make with flash plate Cute/Loop/Shell/Nova (Code No. concealo-H(80mm Body sap code 508179 of Hindware or equivalent).
Supplying fitting & fixing Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets. 630 mm X 450 mm size
Supplying fitting & fixing CP Centre hole Basin mixture with regular spout without popup waste system with 450 mm long braided hoses. (Equivalent to Code No. 5167(B) & Model - FLORENTINE of JAQUAR or similar brand).
Supplying fitting & fixing waste fittings complete. (ii) 32mm C. P. Over Brass
Supplying fitting & fixing CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand).
Supplying fitting & fixing Chromium plated shower arm 240 mm long (Equivalent to Code No. 536(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying fitting & fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.
Supplying fitting & fixing CP Sink Cock with Regular Swinging Spout (Table Mounted Model) (Equivalent to Code No. 5357 of JAQUAR or similar brand).
Supplying fitting & fixing complete Bottel waste Trap (heavy quality) (a) Chromium plated Bottle trap 32mm with 190mm long connecting pipe and wall flange (equivalent to Code No. 545 & Model - Tropical/ Sumthing Special of ESSCO or similar brand)
Providing & fixing in position best Indian make toilet paper holder complete in all respects including cutting and making good the walls etc.
Providing & fixing in position CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. (Code No.5041 & Model - FLORENTINE of JAQUAR or similar brand).
Providing & fixing in position CP Piller Cock 15mm (equivalent to code no 507 & Model Tropical /Sumthing special of Essco pr similar brand.
Providing & fixing in position Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or simila
Providing & fixing C.P. brass towel rail fixed with 2 brackets. 25mm dia & 750mm long.
Fixing cromium plated soap container of approved make. Including providing & fixing screws, washers, cutting & making good the walls.
Providing & fixing C.P. liquid soap holder of best quality.
Providing & fixing in position best Indian make C.P. brass twin way Coat and hat hooks ( Equivalent to Code No. 35761 & Model Kubix of Jaquar or similar) fixed into wall with C.P.brass screws and rawlplugs etc. complete including cutting and making good the walls etc.
Providing & fixing of Hand Shower (Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Providing fitting & fixing Bevelled Edged Mirror 5.5mm thick silver red as per IS 3438/1965 together with brass CP hinges. 600mm x 450mm
INTERNAL DRAINAGE : (SOIL, WASTE, VENT AND RAIN WATER PIPES & FITTINGS) Supply of UPVC pipe & fittings B type confirming to IS 13592-1992. 110 mm dia. (SP , WP & RWP)
(ii)Plain tee
(iii)Door Tee
(v)Plain 'Y'
(vii)Double 'Y'
(ix) Bend 45 degree
(xi) Door Bend
(xv) Vent Cowl
(xx) 125/110 P Trap with W.C. Ring
(xxxiv) Multi Floor Trap
Labour for fittings and fixing UPVC pipes for above ground work including cost of jointing materials etc.
Supplying & fixing CI grating.
Supplying fitting & fixing PVC pipes for underground work of approved make of schedule 80 (medium duty) conforming to ASTMD- 1785. 32mm
Providing and fixing M.S. holder-bat clamps of approved design to PVC pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) For 110 mm dia. pipe
COLD / DRINKING WATER SUPPLY: INTERNAL WATER SUPPLY WORK:- Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threated fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cemetnt and testing of joints complete as per direction of engineeer in charge. (For internal Toilets only) 15 mm dia (for concealed work)
20 mm dia (for concealed work)
25 mm dia (for concealed work)
20 mm dia (for exposed work)
25 mm dia (for exposed work)
32 mm dia (for exposed work)
40 mm dia (for exposed work)
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 20mm
Supplying PVC water storage tank of approved quality with closed top with lid (Black)- Multilayer. 2000 litre capacity
Labour for hoisting plasting water storage tank
Labour for punching hole in plastic water storage tank upto 50mm dia
EXTERNAL Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross,elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc.fitted including cost of all materials ,jointing materials,cutting pipes,making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) (for external Sewer & Storm Water Drain) 150 mm
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm(depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides,bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. Supplying, fitting and fixing yard gully with approved H.C.I. grating complete. (i) 225 mm X 150 mm with 230 mm gratings
(ii) 150 mm X 100 mm with 150 mm gratings
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). (iii) 65 mm dia
(iv) 50 mm dia
(v) 40 mm dia
Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made (iii) 25mm dia. (irrigation)
(iv) 32 mm dia. medium quality (for transffer water line from ugr to ohr)
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (h) 5000 litre capacity
Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for non-pressure underground Drainage, Sewerage & Cross drainage application.(iv) 300mm internal dia.
PART H: Installation of Tubewell: Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (a) For depth upto 250 metre for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 metre). (i) First 50 metre
(ii) Next 50 metre
(iii) Next 50 metre
(iv) Rest 100 metre
Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in Charge (a) 100 mm nominal dia (i) 6.00 mm wall thickness
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (Dia) 100 mm
Supplying M.S. male / female adopter of approved make and brand for coupling of M.S. pipe and fibre glass strainers, as per direction of the Engineer - in - Charge. (i) 100 mm
Supplying, fitting and fixing heavy type bell mouth reducing socket. (iv) 100 mm X 200 mm
Supplying, fitting and fixing G.I. cap at top. (iii) 200 mm
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete. Note: Initial 6 m. of Annular space between the housing pipe and the bore should not be shrouded with Pea size gravel to avoid contamination with surface water.
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
Providing 200 mm centre guide. i) With Clamp
Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report.
PART I: Electrical:(A part) Internal E.I. Works S&F of 230 V., 32 A. DP Main Switch in Sheet Steel enclosure on flat iron frame on wall. (L&T/ Siemens/ Havells). (For Toilet Block)
Supplying and fixing of double-door SPN MCB DB with IP-42/43 protection, concealed in wall / on wall incl. necy. connection as per GS. (Legrand/ Siemens/ L&T/ Cabtree). 2+6 way Enclosure - 1 no. 240 V., 20 A. DP MCB & 6 nos. 240 V., 6-10 A. SP MCBs as required. (For Toilet Block and Security Building)
2+4 way Enclosure - 1 no. 240 V., 16 A. DP MCB & 2 nos. 6 A.-10 A SP MCB and 2 Nos Blank Plates as required. (For Pargola Seating areas / Kiosks)
2+12 way Enclosure - 1 no. 240 V., 25 A. DP MCB & 12 nos. 240 V., 6-16 A. SP MCBs as required. (For main bungalow building)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish [for new Toilet Block and new Security Building] Average run 7 mtr
Average run 9 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish On Board.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing capping and Switch board both on surface] [for Main Bungalow] Average run 9 mtr
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sq.mm.) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sq.mm.) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages tobuilding works [PVC casing-capping and plug box both on surface] On Board.
S&F PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required as per GS. 20 mm dia
25 mm dia
Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works 20 x 10 mm size
25 x 10 mm size
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) 13 mm dia 3mm thick Polythene Pipe
19 mm dia 3mm thick Polythene Pipe
Cutting channel of 31 mm x 31 mm/ 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire incl. mending good damages to building works. 13 mm dia 3 mm thick polythene pipe without earth continuity wire
19 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Laying 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Finolex/ Polycab/ Havells) of the following sizes in the prelaid pipe and making necy. connection as required. 3 x 1.5 sqmm (for Sep. 6 A. points & for looping wires of Poles)
2 x 2.5 sqmm + 1 x 1.5 sqmm as ECC (for Computer Boards & Sep. 16 A. Board)
2 x 4 sqmm + 1 x 2.5 sqmm as ECC (For AC points & for SPN DB at Toilet Block)
4 x 6 sqmm + 2 x 4 sqmm as ECC (For Timer).
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 1.5 sq.mm. - N.S.
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
S&F of 240 V. 6 A. 3 pin Modular type plug socket (Legrand-Myrius/ Cabtree) with 230 V., 6 A. Modular type switch, without plug top - 2 sets on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall / on wall incl. S&F switch board and cover plate and making necy. connections as per GS.
Supply & Fixing 240 V., 16 A., 3 pin Modular type plug socket (Brand approved by EIC) with 16 A. Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc..
Supply & Fixing 240 V, 4 nos. 6 A., 3 pin Modular type plug socket with 4 nos. 6 A. Modular type switch (Brand approved by EIC), 16 A. Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall / on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Computer Board).
S&F 240 V. 20 A./ 25 A. Modular type starter (Legrand-Myrius/ Cabtree) with 16 A. Modular switch type SP MCB ("C" Curve) and 1 no. Blank Plate and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections as per GS. (AC Starter Board).
Supply & Fixing 240 V., 25 A., 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.. (for AC points & Geyser points)
S&F sheet metal inspection box (16 SWG) of the following sizes flushed in wall after cutting brick wall / on wall incl. making earthing attachment, painting and mending good damages to building works. 200 mm x 150 mm x 65 mm
150 mm x 100 mm x 65 mm
100 mm x 100 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws. 200 mm x 150 mm x 65 mm
150 mm x 100 mm x 65 mm
100 mm x 100 mm x 65 mm
Supply and delivery of Twin LED Fitting (2x18 Watt,230VAC, 50Hz, 4000K NW, THD<10%, built in 2.5KV SPD) with all accessories and 2 nos LED Tubes, as directed by EIC.105 ≤ Luminious efficacy < 120 Lumen/watt. The LED Luminaries & accessories should have BEE certification. (Make -Havells/ Philps/CG/Wipro/Surya )
Supply and delivery of Single LED Fitting (18Watt,230VAC, 50Hz, 4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 1 nos LED Tube, as directed by EIC.105 ≤ Luminious efficacy < 120 Lumen/watt. The LED Luminaries & accessories should have BEE certification. (Make -Havells/ Philps/CG/Wipro/Surya )
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW block and ceiling plates, nipples / GI Z clamp etc. as required.
Fixing only single/twin Tube light fitting suspended 25 cm below the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts as per GS. incl. necy. connection by 2 x 1.5sqmm. flexible copper wire of 1.10 mt. length.
S&F of 230 V., 9 W. - 12 W. decorative wall mounted LED light fitting, body made by Aluminium and Transparent diffuser and IP65 protection on wall by fust nuts, washers etc. as required incl. S&F of 230 V., 9 W. - 12 W. E27 type LED bulb incl. necessary connection as per GS. (Philips - 58174 and 9 W. E27 based LED bulb/ CG/ Bajaj/ Jaguar - Morphis Wall Light) with warrenty. (For outside Verandah of main bungalow).
S&F of 230 V. 9 W pin type (B22) LED bulb (Philips/ CG/ Bajaj - 830052) on existing Angular Holder.
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supplying & Fixing of Box type fan clamp of 150 mm dia & 80 mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
S&D of 230 V. 55 W., 1200 mm sweep, Brown coloured decorative ceiling fan with complete accessories like blades, canopy, fork, rubber bush etc with 3 years warrenty incl. following specifications - (Orient/ Usha - Striker 1 star/ Crompton - Aura). Capacitor - P2 type. Speed - 370 - 380 RPM. Air Delivery - 220 - 230 M3/min. Including Safety Wire. V2 grade ball bearing for whisper-quiet operation and durability.
S&D of 230 V. 45 W., 900 mm sweep, Brown coloured decorative ceiling fan with complete accessories like blades, canopy, fork, rubber bush etc with 3 years warrenty incl. following specifications - (Orient/ Usha - Striker 1 star/ Crompton - Aura). Capacitor - P2 type. Speed - 300 - 330 RPM. Air Delivery - 180 - 200 M3/min. Including Safety Wire. V2 grade ball bearing for whisper-quiet operation and durability.
Supply & delivery of wall Fan 400 mm, full metal body, speed of 1325 RPM, air delivery of 110 CMM.The fan comes with a unique pull cord mechanism for On/Off & speed control. The guard & ring of the wall fan are powder coated for longevity & ease of maintenance.Motor of the wall fan is equipped with a thermal overload protection device with auto reset functionality to protect it from overheating, thereby adding to its safety & durability. (Make Orient /Crompton/Usha/ Bajaj/Havells)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod and making necessary connection by 2x1.5 sqmm flexible copper wire.
Fixing only cabin fan/ wall bracket fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
S&F of 230 V., 27 W. decorative LED Pendent (Single) type light fitting, made by Aluminium & Metal incl. E27 type light base with 230 V., 27 W. E27 based LED lamp, on ceiling by fust nuts, washers etc. as required incl. necessary connection as per GS. (Philips - 58147 & TForce Core 27W., 3000 lm E27/ CG/ Bajaj/ Jaguar) with warrenty. (For Pargola Seating Area).
S&D of following dia & RPM Heavy duty exhaust fan with complete accessories like blades etc. with 3 years warrenty. (Make: E.P.C./ CG). 9" dia Exhaust Fan with 1370 RPM
12" dia Exhaust Fan with 920 RPM
Fixing only following exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as required and providing necy. length of PVC insulated wire and making connection as per GS. 9" dia Exhaust Fan
12" dia Exhaust Fan
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long). For Al. - 9" dia Exhaust Fan
Supply & Fixing GI sheet (20 SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 12" dia Exhaust Fan
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.
S&F of 230 V., 10 - 14 W. LED Mirror light fittings incl. all accessories on wall by screws etc. as required incl. necessary connection as per GS. with 2 years warrenty. (Philips - 31165/CG - LCL-14-CDL).
S&F of 230 V. decorative Chandeliers, suspended from ceiling as per direction of E.I.C. incl. necessary connection as required as per GS. (Philips/ Jaguar - KCH-WTC-MD150300088A/ Bajaj) for Kiosks.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI Pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar as per GS.
Connecting the equipments to earth busbar including S & F following size GI (Hot Dip) wire on wall/floor with staples buried and making connection to equipments as per GS. 10 SWG
Compound Illumination:- S&F of suitable size of timer box made by MS sheet (16 SWG), consisting with 1 no. 415 V., 20 A., FP MCB, 1 no. 415 V., 25 A., 4 pole Power contactor, 1 no. 230 V., 6 A. SP MCB, 1 no. 10 A. toggle switch, 1 no. Digital timer clock, 1 no. 20 A. push on/ off type starter for manual operation, 4 nos. Inditating lamps, 1 no. 4 pole connector etc. incl. suitable size of interconnecting wires (power line drawn by 4 sq.mm. copper wire & control & indicating circuit drawn by 1.5 sq.mm. copper wire with copper sockets) as reqd. and Painting by 2 coat synthetic enamel paint over 1 coat RO primer on MS sheet as per GS and as per direction of E.I.C.. (For Compound lighting)
Supplying and fixing of double door Horizontal TPN MCB DB with IP-42/43 protection, concealed in wall incl. necy. connection as per GS. (Legrand/ Siemens/ L&T). 4 way- 1 no. 415 V., 25 A. FP MCB & 12 nos. 240 V., 16-32 A. SP MCBs as required.
S&D of the following sizes 1.1 KV voltage grade XLPE/PVC insulated Copper / Al. Armoured Cables. (Make: Havells/ Polycab/ Finolex). 2 core x 10 sq.mm. Al. Ar. Cable (for SPN DBs at Main bungalow building, Toilet Block and Security Room)
3 core x 4 sq.mm. Copper Ar. Cable (for Garden lights & Statue lights, for SPN DBs at Pargola Seating area/ Kiosks etc.)
3 core x 1.5 sq.mm. Copper flexible Cable (from Driver of Fountain light to LED Fountain lights)
4 core x 10 sq.mm. Al. Ar. Cable (for Compound Lights)
Laying of following cables on wall/surface incl. S & F MS saddles & earthing attachments, making holes etc. as necy. mending good damages and painting. 2 core x 10 sq.mm. Al. Ar. Cable with 1 no. 10 SWG GI (Hot Dip) wire
3 core x 4 sq.mm. Copper Ar. Cable
4 core x 10 sq.mm. Al. Ar. Cable with 2 nos. 10 SWG GI (Hot Dip) wire
Laying of following cables in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed 2 core x 10 sq.mm. Al. Ar. Cable
3 core x 4 sq.mm. Copper Ar. Cable
3 core x 1.5 sq.mm. Copper Ar. Cable
4 core x 10 sq.mm. Al. Ar. Cable
Laying only following Cable through existing GI Pipe. 2 core x 10 sq.mm. Al. Ar. Cable
3 core x 4 sq.mm. Copper Ar. Cable
3 core x 1.5 sq.mm. Copper Ar. Cable
4 core x 10 sq.mm. Al. Ar. Cable
Laying of following cable, after cutting wall and making holes incl., embedding the cable at an average depth of 75 mm in wall etc. and mending good the damages to original finish incl. removing the rubbish. 2 core x 10 sq.mm. Al. Ar. Cable
3 core x 4 sq.mm. Copper Ar. Cable
3 core x 1.5 sq.mm. Copper Ar. Cable
4 core x 10 sq.mm. Al. Ar. Cable
S&F of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC insulated Al. armoured cables as below. 2 core x 10 sq.mm. Al. Ar. Cable
3 core x 4 sq.mm. Copper Ar. Cable
4 core x 10 sq.mm. Al. Ar. Cable
Finishing the end of following XLPE/PVC insulated Al. armoured cables by crimping method incl. S&F of solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: 2 core x 10 sq.mm. Al. Ar. Cable
4 core x 10 sq.mm. Al. Ar. Cable
S&F of following size medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 25 mm dia
32 mm dia
40 mm dia
S&D of 80 mm dia x 1.5 mts. long GI Pipe pole (ISI-Medium) with 1 no. 3 mm thick G.I sole plate incl. necy. holes on sole plate as required, welded with pipe pole and Erection the pole by providing cement concrete (6:3:1) muffing around the pole of dimension 600x600x600 mm on the roof of the building after chipping the roof and fix the pole on the position by using fust nuts incl. 3mm thick net cement finish and providing G.I. earth bolt after making hole by drilling etc. on pole incl. painting the pole by 2 coat Aluminium paint over 1 coat RO Primer after cleaning the surface by emery paper as per direction of E.I.C..
S&F of single arm header fabricated with 100 mm dia, 3 mm thick & 10" height G.I. pipe (pole cap) welded with 1.5 mtr. long 40 mm dia. 3 mm thick G.I. pipe at an angle of 20 to 25 deg with horizontal axis by using nuts, bolts washers etc. incl. painting by 2 coat Aluminium paint over 1 coat RO Primer after cleaning the surface by emery paper as per direction of E.I.C..
Supply & delivery or 7.0 Mtr Hot Dip Galvanized (86-65 micron dry film thickness) Octagonal Pole, as per BSEN 10025; ASTM A 572; IS 5986: IS 4759/2629, ASTM A 123 and BSEN IS 1461 standard. The pole should he 7.0 Mtr long, bottom dia-130 mm, top dia-70 mm, thickness-4 mm, continuously tapered and shall have octagonal cross section with pole cap at lop, necessary cleat attachment/hanger for arm brackets.Bass-plate having dimension 220x220x12 mm and 4 nos 'J' Type foundation boll with double nut and plate washer, boll dia 20 mm , PCD- 200-225 mm ,bolt length- 700 mm, projected bolt length- 100 mm ( these dimention are subjected to tolerance as per 1S-2102 except for bending radius). The pole will consist of a built-in loop-box having one number 32 A, 3 Phase 3 Way connector with Neutral link on porcelain insulator (for incoming/outgoing cable and luminaries connection), and 4 numbers (6-32 A) SPMCB. The door opening shall be complete with a closefitting. vandal resistance, weatherproof door ( to IP-55 of IS:2147), providing with a heavy duty double internal lock with specml paddle key. The door opening shall be carefully designed and reinforced with welded steel section , so that the mast section at the base shall be unaffected and undue buckling of the cut portion is prevented.The Pole should be supplied with adequate templates for the purpose of construction of base foundation.The pole should have earthing terminals 02(two) nos at a height of 600 mm from the base plate for connection of earth continuity wires/ conductors.
S&F 50 mm. dia 1.0 mtr. long detachable type G.I. Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC. (86-65 micron dry film thickness) (As per IS 5986: IS 4759/2629, ASTM A123 and BSEN IS 1461 standard.)
S&F 50 mm. dia 1.0 mtr. long detachable type GI Double arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC. (86-65 micron dry film thickness) (As per IS 5986: IS 4759/2629, ASTM A123 and BSEN IS 1461 standard.)
Erection of upto 7 Mtr octagonal GI (Hot Dip Galvanised in single dip) pole 1.6 Km from the store to work-site with foundation of M20 grade concrete for 7.0 Mtr GI Octagonal Pole with all the matenals like sand, cement, stone chips, reinforcement steel, binding wire etc as relavent IS Code. soil bearing capacity at site as 10 T/sqmtr., by PCC Base foundation having (L- 1000mm x W-1000mm x H-100mm) & RCC foundation having dimension (L-500mm x W-500mm x H-1400mm) including neatly cemented finish (3mm thick) partly below and above ground level. There should be multiple alkathene pipes., upto 1.2 mtrs of 50 mm dia of adequate length for distribution of incoming & outgoing cables for street light wiring as directed by EIC in the CC foundation of octagonal poles
Supply and delivery 3 mtr length decorative hot dipped galvanised MS circular pole suitable for avove light fiting having opening window of 300x100 mm (min) incl. terminal and 6A SP MCB ( C curve) , necessary foundation nut bolts and accessories complete set.( Make-Philips/ Havells/ Crompton/ K- Lite/Wipro/ Havells as per choice of EIC)
Erection/Fixing of above pole after making foundation of above pole with Base Flange & foundation nuts, Bolts etc on RCC (4:2:1) stepped foundation having (L-450mm x W-450mm x H-450mm) below the ground level and (L-300mm x W-300mm x H-150mm) above ground level including neatly cemented finish (3mm thick) above ground level incl. earthing connection etc. & carriage of pole upto 1.6 Km from the store to work-site including filling up the pit with shifted soil and ramming properly as directed by EIC.
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V. 15 A. kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for PVC insulated Al. armoured cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint (for Mini Poles)
S&F of GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V. 16 A. kit-kat fuse unit, one NL on porcelain insulator and earthing terminal with lug, on wall by fust nuts, washers etc. as required including painting with anticorrosive paint. (for Glow Sign Board & Gate Lights).
S&Laying of 13 mm dia 3 mm thick heavy gauge Polythene Pipe through Mini Poles / Poles with S& Laying GI fish wire for drawing looping wires. (from Loop Box to Outdoor light fitting).
S&Laying of 13 mm dia 3 mm thick heavy gauge Polythene Pipe on wall by using Al. Shaddle and mending good damages to building works. (from Loop Box to Glow Sign Board and Gate light fittings).
S & D of 240V, 7200 Lumens (minimum) LED Street Light Fittings with IP 66/ 67, IK 10 protection including 10 KV SPD with CCT 5700K & Luminious efficacy 120Lumen/Watt minimum or better at L70B50, LED Driver should with stand 440V for 8 hours Inbuilt surge protection 4 KV and 10 KV Surge protection inside lumunaries. The LED luminaires and accessories shall have BEE Certification & LED should be with lens (Light efficacy will not get depriciated less than equal to 70% of the rated value over the lifetime of the Luminaries) (Make: Philips(Signify) / Surya/ Crompton,/Orient, Make approved by EIC) (Manufacturer warranty should not less than 3 years).
S & D of 240V, 10800 Lumens (minimum) LED Street Light Fittings with IP 66/ 67, IK 10 protection including 10 KV SPD with CCT 5700K & Luminious efficacy 120Lumen/Watt minimum or better at L70B50, LED Driver should with stand 440V for 8 hours Inbuilt surge protection 4 KV and 10 KV Surge protection inside lumunaries. The LED luminaires and accessories shall have BEE Certification & LED should be with lens (Light efficacy will not get depriciated less than equal to 70% of the rated value over the lifetime of the Luminaries) (Make: Philips(Signify) / Surya/ Crompton,/Orient, Make approved by EIC) (Manufacturer warranty should not less than 3 years).
S&D of 230 V., Minimum 35 Watt, decorative Heritage type post top LED Gate light fitting with IP65 protection and necessary accessories (Philips/ CG - CBP-610-35-57-SL-CA-NBK/ Bajaj/ Wipro/ Jaguyar) with warrenty. (for Gate lighting and Main Road lighting)
Fixing only the LED outdoor Light fittings on pole by Co's own tools & tackles incl. necessary connection as required with earthing as per direction of E.I.C..
Fixing only Gate light fittings on "L" arm bracket incl. S&F of "L" arm bracket made by 1.5 mtr. long 50 mm dia GI pipe [ISI-M] with a sole plate, welded with one leg of GI pipe, fixed on column by 4 nos. suitable sized of fust nuts, washers etc. as per direction of E.I.C..
S&F of 230 V., 10/ 12 W., IP65 protection, decorative LED Bollard light fittings Warm White, made with Die cast aluminium housing with Polycarbonate frosted diffuser incl. necessary connection as required as per direction of E.I.C. (Philips/ CG - LBLA3-10-WW/ Bajaj/ Wipro/ Jaguyar) with warrenty.
S&F of 230 V., 12 W. - 20 W., outdoor type COB Focus light with CCT - min. 5000 K., IP 65 protection incl. necessary connection as required as per direction of E.I.C. (Philips/ CG/ Bajaj/ Jaguyar - LFCLB1R020XC/ Wipro - LF04-181-030-30) with warrenty.
Foundation of above bolard light fitings with Base Flange & foundation nuts, Bolts etc on RCC (4:2:1) stepped foundation having (L-200mm x W-200mm x H-250mm) below the ground level and (L-200mm x W-200mm x H-100mm) above ground level including neatly cemented finish (3mm thick) above ground level incl. fixing of the above light fitings and making necessary connection and filling up the pit with shifted soil and ramming properly as directed by EIC.
Supply & Installation of LED Sign Board of size 20' × 4' with front size 3mm thick A-1 quality ACP blue colour (AD-41) board capable of preventing avoid wind pressure which is also to be attached to MS angle structure (front/back side of board of suitable size MS Angle /MS hollow square/rectangle bar by drilling hole incl. S&F special type steel nuts, bolts and waser. The matter of the LED Sign board should be in English and Bengali alphabets made of laser cutting box type by white colour letter incl. all fixing facility from 3mm thick imported white acrylic sheet including jointing/setting the same part by part and fixing on the board by using cloroform/machine screw etc. is to be fixed on ACP board (on front) incl. S&F SMD module (best quality make) of required quality for illumination of this letters including necessary interconnection & SMPS. The matter as per direction of EIC. Making necessary arrangement for fixing the above LED board by making necessary supporting structure to resist storm by S&F of 40mm × 40mm × 5mm M.S. angle incl.making brick foundation at on height of 5ft from roof level incl. all fixing accessories including providing necessary fixing materials.
Electrical:(B part) Internal E.I. Works S&F of 3 nos. 415 V., 100 A. porcelain type kit kat fuses with 1 no. 415 V., 63 A. neutral link on suitable size of good quality 1" thickness ply board incl. S&F of suitable size of ply board, fixed on wall by fust nuts etc. as per direction of E.I.C. (Havells/ Currency).
S&F of 415V., TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (L&T/ Siemens) 100 A.
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc 125 A.
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc. incl. powder coated painting. 100 A.
Supplying and fixing of double door VTPN MCB DB with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. necy. connection as per GS. (Legrand/ Siemens/ L&T/ ABB). 6 way- 1 no. 415 V., 100 A. FP MCCB (Input) & 2 nos. 415 V., 32 A. TP MCBs, 1 no. 415 V., 25 A. TP MCB, 1 no. 415 V., 20 A. TP MCB & 6 nos. 230 V., 16 A. - 25 A. SP MCBs as required.
Supplying and fixing of double door Horizontal TPN MCB DB with IP-42/43 protection, concealed in wall incl. necy. connection as per GS. (Legrand/ Siemens/ L&T). 4 way- 1 no. 415 V., 32 A. FP MCB & 12 nos. 240 V., 16-32 A. SP MCBs as required.
Supplying and fixing double door sheet steel (16 SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc. incl. provision for earthing attachment 6 way
Supplying and fixing of double-door SPN MCB DB with IP-42/43 protection, concealed in wall incl. necy. connection as per GS. (Legrand/ Siemens/ L&T/ Cabtree). 2+12 way Enclosure - 1 no. 240 V., 32 A. DPMCB & 10 nos. 240 V., 6-16 A. SPMCBs as required.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish Average run 8 mtr
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick olythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average run 8 mtr
Distn. wiring in 3 x 22/0.3 (1.5 sq.mm.) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by E.I.C.) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V., 6 A., 5 pin plug point incl. S&F of 240 V., 6 A., 3 pin Modular type plug socket & Modular type switch (Brand approved by E.I.C.) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish On Board.
S&F PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required as per GS. 20 mm dia
25 mm dia
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) 13 mm dia 3mm thick Polythene Pipe
19 mm dia 3mm thick Polythene Pipe
Cutting channel of 31 mm x 31 mm/ 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire incl. mending good damages to building works. 13 mm dia 3 mm thick polythene pipe without earth continuity wire
19 mm dia 3 mm thick polythene pipe without earth continuity wire
Supplying and Laying 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Finolex/ Polycab/ Havells) of the following sizes in the prelaid pipe and making necy. connection as required. 3 x 1.5 sqmm (for Sep. 6 A. points)
2 x 2.5 sqmm + 1 x 1.5 sqmm as ECC (for Computer Boards & Sep. 16 A. Boards)
2 x 4 sqmm + 1 x 2.5 sqmm as ECC (For AC Points & Geyser Points)
2 x 10 sqmm + 1 x 6 sqmm as ECC (For SPN DBs).
4 x 10 sqmm + 2 x 6 sqmm as ECC (For TPN DB).
4 x 25 sq.mm. (From Meter to Cut Outs ) - N.S.
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 1.5 sq.mm. - N.S.
25 sq.mm. - N.S.
S&F of 240 V. 6 A. 3 pin Modular type plug socket (Legrand-Myrius/ Cabtree) with 230 V., 6 A. Modular type switch, without plug top - 2 sets on 6 Module GI Modular type switch board with 6 Module top cover plate on wall incl. S&F switch board and cover plate and making necy. connections as per GS.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Computer Board).
S&F 240 V. 20 A./ 25 A. Modular type starter (Legrand-Myrius/ Cabtree) with 16 A. Modular switch type SP MCB ("C" Curve) and 1 no. Blank Plate and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections as per GS. (AC Starter Board).
Supply & Fixing 240 V., 25 A., 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.. (for AC points & Geyser points)
Supply & Fixing 240 V., 25 A., 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supply & Fixing 240 V., 25 A., 3 pin Modular type switch (Brand approved by EIC) with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.. (for Geyser points)
S&F sheet metal inspection box (16 SWG) of the following sizes flushed in wall after cutting brick wall / on wall incl. making earthing attachment, painting and mending good damages to building works. 240 mm x 200 mm x 65 mm
200 mm x 150 mm x 65 mm
150 mm x 100 mm x 65 mm
100 mm x 100 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws. 240 mm x 200 mm x 65 mm
200 mm x 150 mm x 65 mm
150 mm x 100 mm x 65 mm
100 mm x 100 mm x 65 mm
Supply and delivery of Twin LED Fitting (2x18 Watt,230VAC, 50Hz, 4000K NW, THD<10%, built in 2.5KV SPD) with all accessories and 2 nos LED Tubes, as directed by EIC.105 ≤ Luminious efficacy < 120 Lumen/watt. The LED Luminaries & accessories should have BEE certification. (Make -Havells/ Philps/CG/Wipro/Surya )
Supply and delivery of Single LED Fitting (18Watt,230VAC, 50Hz, 4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 1 nos LED Tube, as directed by EIC.105 ≤ Luminious efficacy < 120 Lumen/watt. The LED Luminaries & accessories should have BEE certification. (Make -Havells/ Philps/CG/Wipro/Surya )
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW block and ceiling plates, nipples / GI Z clamp etc. as required.
Fixing only single/twin Tube light fitting suspended 25 cm below the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts as per GS. incl. necy. connection by 2 x 1.5sqmm. flexible copper wire of 1.10 mt. length.
S&F of 230 V. following Wattage LED recessed mounted fittings with complete accessories incl. necessary connection as required as per GS. 2'x2' 36-40 W. square type LED Recessed mounted fittings. (CG/ Philips/ Wipro/ Bajaj)
18 W. round type LED Recessed mounted fittings. (CG/ Philips/ Wipro/ Bajaj)
S&F of 230 V., 9 W. - 12 W. decorative wall mounted LED light fitting, body made by Aluminium and Transparent diffuser and IP65 protection on wall by fust nuts, washers etc. as required incl. S&F of 230 V., 9 W. - 12 W. E27 type LED bulb incl. necessary connection as per GS. (Philips - 58174 and 9 W. E27 based LED bulb/ CG/ Bajaj/ Jaguar - Morphis Wall Light) with warrenty.
S&F of 230 V. 9 W pin type (B22) LED bulb (Philips/ CG/ Bajaj - 830052) on existing Angular Holder.
Supplying & Fixing of Box type fan clamp of 150 mm dia & 80 mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
S&D of 230 V. 55 W., 1200 mm sweep, Brown coloured decorative ceiling fan with complete accessories like blades, canopy, fork, rubber bush etc with 3 years warrenty incl. following specifications - (Orient/ Usha - Striker 1 star/ Crompton - Aura). Capacitor - P2 type. Speed - 370 - 380 RPM. Air Delivery - 220 - 230 M3/min. Including Safety Wire. V2 grade ball bearing for whisper-quiet operation and durability.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod and making necessary connection by 2x1.5 sqmm flexible copper wire.
Supply & delivery of wall Fan 400 mm, full metal body, speed of 1325 RPM, air delivery of 110 CMM.The fan comes with a unique pull cord mechanism for On/Off & speed control. The guard & ring of the wall fan are powder coated for longevity & ease of maintenance.Motor of the wall fan is equipped with a thermal overload protection device with auto reset functionality to protect it from overheating, thereby adding to its safety & durability. (Make Orient /Crompton/Usha/ Bajaj/Havells)
Fixing only cabin fan on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
S&D of following dia & RPM Heavy duty exhaust fan with complete accessories like blades etc. with 3 years warrenty. (Make: E.P.C./ CG). 9" dia Exhaust Fan with 1370 RPM
12" dia Exhaust Fan with 920 RPM
Fixing only following exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as required and providing necy. length of PVC insulated wire and making connection as per GS. 9" dia Exhaust Fan
12" dia Exhaust Fan
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long). For Al. - 9" dia Exhaust Fan
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 12" dia Exhaust Fan
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.
S&F of 230 V., 10 - 14 W. LED Mirror light fittings incl. all accessories on wall by screws etc. as required incl. necessary connection as per GS. with 2 years warrenty. (Philips - 31165/CG - LCL-14-CDL).
S&D of 230 V., 6 W. LED Step light fitting with 2 years warrenty. (PHILIPS / CG - CBR-611-06-30-SL-CP-NGG / Wipro / Bajaj).
Fixing only LED step light fitting embedded in wall after cutting the brick wall and mending goods damages to original finish incl. necessary connection as required and as per GS.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 20 x 5 mm GI (Hot Dip) strip (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 32 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar as per GS.
Connecting the equipments to earth busbar including S & F following size GI (Hot Dip) wire on wall/floor with staples buried and making connection to equipments as per GS. 10 SWG
S&D of the following sizes 1.1 KV voltage grade XLPE/PVC insulated Copper / Al. Armoured Cables. (Make: Havells/ Polycab/ Finolex). 4 core x 70 sq.mm. (for Interconnection at Panel portion and DG AMF panel)
Laying of following cables on wall/surface incl. S & F MS saddles & earthing attachments, making holes etc. as necy. mending good damages and painting. 4 core x 70 sq.mm. with 2 nos. 10 SWG GI (Hot Dip) wires
Laying of following cables in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed 4 core x 70 sq.mm.
S&F of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC insulated Al. armoured cables as below. 4 core x 70 sq.mm.
Finishing the end of following XLPE/PVC insulated Al. armoured cables by crimping method incl. S&F of solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: 4 core x 70 sq.mm.
Total
Add GST @ 18%
Total
Add Labour Welfare Cess @ 1%
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Hardscaping Work including Pathways: Supplying and Installation of Mural, Musical Node, FRP Bengali Letter , As per the design provided by the Architect, the letter will be made of multiple medias altogether such as Fibre Glass, MS structure, Casting Rod, Thread Rod and other fixers, Backlit inside LED light (VIBGYOR). Note: Colour shades of the features in the Letter will be as per Architects approval.
Children's playing equipment
Landscaping work of the compound: Supplying of different plant / trees, minimum height as specified including all leads & lift, carriage, handling etc Tree Species Yellow Coconut of height 6'-8'
Plumeria alba of height 6'-7'
Plumeria rubra of height 7'-8'
Lagestromia speciosa(Jarul) of height 6'-7'
Cassia renigera of height 5'-6'
Cristata gold of height 3'-4' (round shape dia 1'-6")
Ficus panda of height 3'-3.5' (Bushy)
Ficus black of height 3'-4'
Terminallia mantally of height 8'-9'
Polandi bottle brush of height 8'-10'
Silver Oak of height 7'-8'
Tecoma gaudichaudi of height 4'-5'
Swarna champa of height 5'-6'
Tabebuia argentea of height 3'-4'
Washintonia filifera palm of height 5'-6'
Mimosops elengi(Bakul) of height 6'-7'
Butea monosperma Tree of height 1'6"'-2' (polash ful)
Ixora singaporensis of height 2'-3'
Coleus sp. of height 1.5'-2'
Bougainvillea sp. (single leaf) of height 2'-3'
magnolia grandiflora Tree of height 7'-8'
Dillenia indica of height 4'-5'
Carica papaya Tree of height 2' (aata)
Ravenala madagascariensis Tree of height 4'-5'
Artabotrys hexapetalus Tree of height 5'-6' (kathalichapa)
Elaeocarpus ganitrus Tree of height 5'-6' (rudrakshya)
Supplying and planting different creeper plants including all leads & lift, carriage, handling & manuring, applying presticide and fertilizer etc Clitoria ternatea (aparajita)
Supplying and planting different Hedge plants including all leads & lift, carriage, handling & manuring, applying presticide and fertilizer etc Lantana camara Tree of height 9"-12"
Acalypha wilkesiana Tree of height 12"-18"
Fucus Panda Golden Tree of height 12"-18"
Supplying and planting plants for making Topiary art or practice of clipping shrubs or trees into ornamental shapes by using necessary cutting tools naturaly used in horticultural aspect and inclusive of necessary growing steps with organic or chemical mixture or material for growing purpose all complete
Supplying white polished pebbles for beautification work
Supply of Orchid including decorative earthen pot
S&P works of Guest House & Exhibition Block: Supplying Fitting & fixing 10ltrs water heater with all necessary accessories fittings. AO SMITH
Installation of TUBE WELL: Supply & fixing 80mm dia CI NoN Returning Valve
Supply, fitting & Fixing 415 Volt 3 phase LT Make Mu-G6 Submersible pump DOL starter on wall by 5mm x 40mm flat MS iron bar frame including all jointing materials (at No. SS97756)
Supply and instalation of 5.00 HP submersible pump motor set with 4.4 mtrs head having discharge capacity 600 LPM at 6 stage 2900RPM 415V (Make Veruna Nodel No V561N or equivalent Model of KSB ).
Submersiable Pump Set: Supplying and installation of 3 HP capacity submersible pump of KIRLOSKAR brand, Phase 3 having outlet 38 mm of 440V with submersible copper cable 38m length of FINOLEX brand, one D.I.L Starter, two nos. switch board including withdrawal of existing pump motor set complete in all respect inclusive of all taxes (GST & Cess) as per Direction of Engineer-In-Charge
Fire Fighting: Supply, fitting, fixing of ABC POWDER TYPE FIRE EXTINGUISHERS(STORED PRESSURE) Stored Pressure Fire Extinguisher ISI marked, powder type suitable for class A, B, C Fire 6 Kg capacity consisting of weilded cylinder, squeeze lever discharge valve, fitted with pressure indicating gauge, internal discharge tube, discharge nozzle and hose, suspension bracket, conforming to IS 15683: 2006 duly charged with ISI marked Mono Ammonium Phospate base ABC Powder conforming to IS: 14609 and pressurized with Nitrogen Gas, suitable for operating between - 300˚ C to +550˚ C, Fire Rating Class -2A & 21B complete in all respect including all taxes and in all floors. A lavel should be pasted on the body of the extinguisher showing 1. Supplied by PWD, 2. Date of Manufacture, 3. Date of Expiry/Date of next refilling.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.53 MB
BOQ_2381831.xls
BOQ • 0.99 MB
2911.pdf
Tender Documents • 1.86 MB
Download all tender documents and submit your bid