Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹31.6 L+₹1.8 L (5.89%)Rejected-Finance 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L2 | Rejected-Finance L2 | |
| 3 | L3₹35.3 L+₹5.5 L (18.3%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance L3 | |
| 4 | L4₹35.7 L+₹5.8 L (19.6%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L4 | Rejected-Finance L4 | |
| 5 | L5₹38.3 L+₹8.4 L (28.2%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | rajengineers L1 | DWARKADHISH ENTERPRISE L3 | SURESH ELECTRICALS L4 | S t modi L6 | MADHAV ENTERPRISE L2 | BHAVNA IMPERIAL ENTERPRISE L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully street light/flood light fittings of any make and capacity, opening for examination & for replacement unservicable spare part and Refixing the same in position after necessary replacement of drivers and minor spare parts at the same/other location,including any UG cable fault it will be rectified or replaced accordingly and necessary T&P like ladder/Boom Vehicle,tools etc as required for taking down & refixing of street light/flood light complete.
Note :-
Rate quoted by the tender is not inclusive of supply of drivers. The supply only of drivers where repaired shall be measured and paid separately under respective item No. 2 | 500 | Each Job | 300 ₹1,50,000 | 75 ₹37,500 Lowest | 299 ₹1,49,500 | 292 ₹1,46,000 | 200 ₹1,00,000 | 95 ₹47,500 |
| 2.00Supply only Led diver for Street light/flood light fitting of following capacity/sizes | |||||||||
| 2.01 | LED driver for light fitting of capacity 200-250 watt. | 20 | Each Job | 1,250 ₹25,000 | 3,000 ₹60,000 | 1,900 ₹38,000 | 2,500 ₹50,000 | 2,150 ₹43,000 | 500 ₹10,000 Lowest |
| 2.02 | LED driver for light fitting of capacity 120-160 watt. | 15 | Each Job | 1,000 ₹15,000 | 2,500 ₹37,500 | 1,300 ₹19,500 | 2,500 ₹37,500 | 1,600 ₹24,000 | 500 ₹7,500 Lowest |
| 2.03 | LED driver for light fitting of capacity 100-110 watt. | 35 | Each Job | 1,000 ₹35,000 | 2,800 ₹98,000 | 1,100 ₹38,500 | 2,000 ₹70,000 | 1,600 ₹56,000 | 500 ₹17,500 Lowest |
| 2.04 | LED driver for light fitting of capacity 45-60 watt. | 30 | Each Job | 750 ₹22,500 | 1,350 ₹40,500 | 900 ₹27,000 | 2,000 ₹60,000 | 900 ₹27,000 | 500 ₹15,000 Lowest |
| 2.05 | LED driver for light fitting of capacity 70-90 watt. | 40 | Each Job | 1,000 ₹40,000 | 1,150 ₹46,000 | 1,000 ₹40,000 | 1,500 ₹60,000 | 950 ₹38,000 | 500 ₹20,000 Lowest |
| 3.00 | S&F in replacement of LED Street Light fitting 120 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified as directed by Engineer in Charge. | 50 | Each Job | 3,604 ₹1,80,200 Lowest | 4,800 ₹2,40,000 | 4,500 ₹2,25,000 | 5,000 ₹2,50,000 | 3,900 ₹1,95,000 | 5,999 ₹2,99,950 |
| 4.00 | S&F in replacement of LED Street Light fitting 90 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified as directed by Engineer in Charge. | 50 | Each | 3,186 ₹1,59,300 | 3,500 ₹1,75,000 | 3,100 ₹1,55,000 Lowest | 3,890 ₹1,94,500 | 3,700 ₹1,85,000 | 3,737 ₹1,86,850 |
| 5.00 | S&F in replacement of LED Street Light fitting 60 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified as directed by Engineer in Charge. | 80 | Each | 2,309 ₹1,84,720 | 2,900 ₹2,32,000 | 2,375 ₹1,90,000 | 3,650 ₹2,92,000 | 2,300 ₹1,84,000 Lowest | 3,131 ₹2,50,480 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Jul 2025, 6:00 pmClosed
Maj Sumukh Swaroop
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
REPAIR MAINT OF HIGH MAST STREET LIGHT FITTINGS AND OTHER CONNECTED ITEMS WORKS UNDER GE (AF) JAMNAGAR NO 1
2025_MES_712454_1
8328/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jamnagar No. 1
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹80,000
Yes
6 Aug 2025
4 Jun 2025
3 Jul 2025
4 Jun 2025
2 Jul 2025
18 Jun 2025
Amount
Taking down carefully street light/flood light fittings of any make and capacity, opening for examination & for replacement unservicable spare part and Refixing the same in position after necessary replacement of drivers and minor spare parts at the same/other location,including any UG cable fault it will be rectified or replaced accordingly and necessary T&P like ladder/Boom Vehicle,tools etc as required for taking down & refixing of street light/flood light complete. Note :- Rate quoted by the tender is not inclusive of supply of drivers. The supply only of drivers where repaired shall be measured and paid separately under respective item No. 2
Supply only Led diver for Street light/flood light fitting of following capacity/sizes
LED driver for light fitting of capacity 200-250 watt.
LED driver for light fitting of capacity 120-160 watt.
LED driver for light fitting of capacity 100-110 watt.
LED driver for light fitting of capacity 45-60 watt.
LED driver for light fitting of capacity 70-90 watt.
S&F in replacement of LED Street Light fitting 120 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified as directed by Engineer in Charge.
S&F in replacement of LED Street Light fitting 90 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified as directed by Engineer in Charge.
S&F in replacement of LED Street Light fitting 60 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified as directed by Engineer in Charge.
S&F in replacement of LED Street Light fitting 70 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified as directed by Engineer in Charge.
S&F in replacement of LED flood Light fitting 120 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified as directed by Engineer in Charge.
S&F in replacement of LED flood Light fitting 200 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified as directed by Engineer in Charge.
S&F in replacement of LED flood Light fitting 240 Watt, including surge protection device 2 KV inbuilt duly electrical connection having system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified as directed by Engineer in Charge.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 10 sqmm 2 /4 core including cable cover all as specified as directed by Engineer in Charge.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 16 sqmm 4 core including cable cover all as specified as directed by Engineer in Charge.
Disconnecting & Taking out LT underground cable from trenches etc, aluminium conductor of size 25 sqmm 3.5 core including cable cover all as specified as directed by Engineer in Charge.
Laying only XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 10 Sqmm 2/4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing all as specified as directed by Engineer in Charge.
Laying only XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing all as specified as directed by Engineer in Charge.
Laying only XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing all as specified as directed by Engineer in Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified as directed by Engineer in Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified as directed by Engineer in Charge.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified as directed by Engineer in Charge.
Supply, jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 10/16/25 Sqmm suitable for 2/3.5/ 4 core all as specified and as directed by Engineer-In-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard/dense soil.
Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using excavated soil all as directed
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed. (Note: Punned thickness of sand shall be considered for payment 18cm)
Laying only PCC cable cover for LT UG cable, of any description retrieved from item No.10 to 12 all as specified as directed by Engineer in charge.
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable as specified as directed by Engineer in charge.
S&F in replacement Tubes 40 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified as directed by Engineer in Charge.
S&F in replacement Tubes 50 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified as directed by Engineer in Charge.
S&F in replacement of LED Aviation obstruction light fitting die cast aluminium alloy housing, heat resistant, clear thick glass and accessories with LED lamp & driver, fixed in position & connecting complete all as specified as directed by Engineer in Charge.
S&F in replacement of 4 Pole 75/80 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified as directed by Engineer in Charge.
S&F in replacement of 4 Pole 32 to 40 Amp power contactor, AC 3 rating, fixed in existing panel & connecting as specified as directed by Engineer in charge.
S&F in replacement Power saver and user friendly analog clock timer to set street light ON/OFF timing complete with stringment international test standards I
Material & Labour in replacement for sub main wiring with 2 run single core multistranded copper conductor cable, of size 1.5 Sqmm each, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through but not including PVC conduit/casing capping and including one run single core multistranded copper conductor cable, of size 1.5 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified as directed by Engineer in Charge. Note: 2 Runs of main cable and one run earth wire will be measured as one unit for payment.
S&F in replacement of 20 mm bore UPVC pipe medium grade inclusive of fitting etc fixed on pole / wall with mild steel clamps made out of MS Flat 25 x 6mm including, nuts, bolts at the interval of 1metre complete including two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified as directed by Engineer in Charge.
S&F in replacement of Sheet moulding compound (SMC) junction box of size 350 mm x 250 mm x 150mm, comprising three phase aluminium bus bar and one No MCB SP, 06 Amps "C" type, fixed on pole with mild steel clamps, nuts and bolts complete all as specified as directed by Engineer in Charge.
M&L for horizontal boring under roads / pavement / hard standing without disturbing the top surface by trench-less technology using ultra sound technique and necessary machine including supply & inserting of HDPE pipe of 90 mm dia suitable for 0.4 MPa working pressure for passing through the cables complete all as specified as directed by Engineer in Charge. Note : Necessary T&P required for boring shall be arranged by the Contractor at his own cost.
S&F IN REPAIR for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised iron strip 32X6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 5 of 1991 (Part-I)complete all as specified as directed by Engineer in Charge.
Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, LT Panel board, confirming to IS 5039 with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 60 x 60 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old panel all as specified and directed & Consisting of the following equipment's:- (a) MCCB 415 Volt 120 Amps, 4 Pole, 16KA-01 (Incoming) (b) MCB 415 Volt 63 Amps, 4 Pole 10 KA-02 Nos (Outgoing)
S&F in repairs Cross arms (ISI Marked), bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified as directed by Engineer in Charge.
M&L preparation of old painted surfaces of RCC street light pole 9 meter long above coping including cross arm etc and applying one coat of weather proof exterior emulsion paint as per the existing colour or as directed by Engineer-in-Charge on RCC pole and applying one coat of synthetic enamel paint for service brackets and MS clamps of light fittings including painting with synthetic enamel paint up to 1.2m from bottom in alternate layers of tri-colour of black,yellow& white and numbering of poles in white paint over the black base complete all as specified and directed.
M&L for preparation of old surfaces & painting of steel tubular pole of up 9 mtr height with two coats of synthetic enamel aluminium paint on pole, cross arms, bracing , clamps GI pipe fittings etc with bottom 1.2m portion painted in alternate layers of tri-colour of black,yellow& white including numbering of poles in white paint over the black base complete all as specified as directed by Engineer in Charge.
Supply and fix in replacement of LED Bollard garden light fitting,IP 65/IK 10 protection, with base plate and necessary foundation and connected electric and PCC works complete all as specified as directed by Engineer in Charge.
Supply and fix in replacement of LED Post-Top lantern, energy saving, environmental friendly, long life aesthtically designed with symmentrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source ,suitable for pole size and making arrangements ,pcc work , electric connections complete all as specified as directed by Engineer in Charge.
Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor twin core 4 sqmm,weather proof,flat or circular served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified as directed by Engineer in Charge.
Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor twin core 6 sqmm,weather proof,flat or circular served with inner sheathing of PVC tape and overall PVC sheathed in service connections all as specified as directed by Engineer in Charge.
Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor twin core 10 sqmm,weather proof,flat or circular served with inner sheathing of PVC tape and overall PVC sheathed in service connections all as specified as directed by Engineer in Charge.
Supply and erect in replacement Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 Note:- (a) Rate quated is inclusive of following (i) Excavation&Earthwork ,Returning filling and Removal of soil (ii) PCC (1:3:6) type c2 as per specification (iii) Coping (1:2:4) type b1 as per specification.
Supply and fix in replacement MCBs TPN pole , 40 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting all as specified as directed by Engineer in Charge.
Supply and fix in replacement MCBs single pole & neutral , 20 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting all as specified as directed by Engineer in Charge.
Supply and fix in replacement MCBs single pole , 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting all as specified as directed by Engineer in Charge.
Supply and fix in replacement MCBs triple pole & neutral , 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting all as specified as directed by Engineer in Charge.
M&L for Repairing of 1 to 1.5 HP capacity electric motor of high mast, AC 3 phase, by dismantling the motor cutting and taking out the old winding wires, cleaning the slots, rewinding the motor with appropriate size of super insulated copper conductor winding wire of same gauge, and varnishing complete including replacing the worn out bearing, reassembling the motor and fixing in same position and testing complete all as specified as directed by Engineer in Charge.
S&F in replacement of 1.5 HP capacity electric motor of high mast, AC 3 phase, by dismantling the motor & fixing the new motor in same position and testing complete all as specified as directed by Engineer in Charge. Make:-kirloskar/crompton/ABB/Lubi/havells.
S&F in replacement of Lantern carriage, made out of Hot Rolled Medium and High Tensile Structural Steel (as per manufacturer design) confirming to IS 2062 -2011) provided with rubber gasket internally for easy movement. Lantern carriage shall be suitable to fix 9 to 12 Nos of luminaries (LED flood lights) symmetrically in 06 welded arm. complete all as specified as directed by Engineer in Charge. Make:-Bajaj/crompton Greaves/Wipro.
S&F in repair Winch sutable for taking minimum 750 kg load. should have double drum, (Gear Ratio - 50 : 1) motor driven / manual driven, self lubricating all as specified as directed by Engineer in Charge. Make:-Bajaj/crompton Greaves/Wipro.
Supply and fix in repairs PVC insulated and sheathed trailing cable copper conductor cable of size 2.5 Sqmm 5 core, EPR PCP round cable 1100 volt grade all as specified as directed by Engineer in Charge.
Taking down high mast light for repairing of unserviceable light, reconnecting disturbed wire, realignment of High mastt carriage etc incluing servicing of complete high mast of any make, model, cap, height by greasing of wire rope, winch, motor , making proper connection of light fittings in lantern carriage, cleaning & making proper connection of High mast panel all as specified and directed. or for repairing and servicing purpose and refixing the same all as specified as directed by Engineer in Charge.
M&L for preparation of old painted surfaces of high mastt ladder type from bottom to top including mounting arrangement at top including cross arm etc and applying two coat of synthetic enamel paint or as directed by Engineer-in-Charge complete all as specified as directed by Engineer in Charge.
S&F in repair wire rope of high mast light from winch to top made out of stainless steel grade AISI 316 suitable for taking min 750 kg load all as specified as directed by Engineer in Charge.
S&F in replacement of mounting bracket for street light fittings made out of GI pipe light grade 40 mm dia upto 1.5 m length bent to shape incl fixing arrangement with neccassary clamps, bolts, nuts, washers etc all as specified as directed by Engineer in Charge.
S&F in replacement of mounting bracket for street light fittings made out of GI pipe light grade 50 mm dia upto 1.5 m length bent to shape incl fixing arrangement with neccassary clamps, bolts, nuts, washers etc all as specified as directed by Engineer in Charge.
M &L Plain cement concrete 1:4:8 type D2 (using 40 mm aggregrate) in base & foundations of electric poles, stays structs etc including necessary form work and fair finish to exposed surfacewithout using extra cement etc complete all as specified as directed by Engineer in Charge.
M&L for Extending/Repairing of damaged Coping of Poles(Steel/prestressed) by PCC(1:2:4) above/below ground level up to size of (0.6x0.6x.3)Metre complete all as specified and directed by Engg-in- Charge.
M&L for cleaning of vegetation/shrubs on pole and upto 2m distance each sides around the pole including cutting/prunning of tree banches all as specified as directed by Engineer in Charge.
Note:(a) One electrician and one helper should be available for attending day to day complaints on all days including/Sunday and holiday (b) Indls should be in possession of all required tools for rectification of complaints . (c) Labour charges and cost of reqired tools is deemed to be included in the rate quoted above .
MADHAV ENTERPRISE (BID ID -3336270)
DWARKADHISH ENTERPRISE (BID ID -3334826)
SURESH ELECTRICALS (BID ID -3335126)
BHAVNA IMPERIAL ENTERPRISE (BID ID -3336925)
S t modi (BID ID -3344719)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .