Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC Lowest Bid Accepted |
| 2 | L2₹1.3 Cr+₹17.5 L (15.1%)Rejected-Finance | ₹1.3 Cr+₹17.5 L (15.1%) | L2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | L3₹1.4 Cr+₹20.8 L (17.9%)Rejected-Finance | ₹1.4 Cr+₹20.8 L (17.9%) | L3 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
29 Jul 2022, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
NON-STRUCTURAL REPAIRS USING GUNITING, MICRO CONCRETING ETC., REPAIRS TO VERTICAL STACKS, REMOVAL OF VEGETATION AND MECHANICAL EXTERNAL PERIODICAL TO HIGH-RISE BUILDINGS AT NAUSENA BAUGH, VISAKHAPATNAM
2022_MES_526957_1
82255 / E8
Open Tender
Civil Works
Item Rate
270 days
Visakhapatnam
Class B
category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Base
₹2.2 L
Yes
10 Sept 2022
24 Jun 2022
5 Aug 2022
24 Jun 2022
29 Jul 2022
15 Jul 2022
1 Jul 2022 - 8 Jul 2022
Amount
Demolition of Reinforced Cement Concrete [reinforcement cut as required to facilitate demolition] of any description and in any position not otherwise specifically provided for and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as specified and as directed.
M & L for 25 mm thick PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in padding over roof slabs and finishing the top surface rough complete all as specified and as directed.
S & F in repairs 0.71 mm thick Plain Aluminium Sheet Alloy 31000 H4 in Ridges, Hips, Valley Gutter, drip and straight flashing, Cover for Crumple Joint complete all as specified and as directed.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Chajjas and the like complete all as specified and as directed.
M & L for RCC M–30 Design Mix, using 20mm graded stone aggregate as in Fins, fascias, louvres, parapets and railings exc. 60cm in height, and the like. complete all as specified and as directed.
Use and removal of steel formwork to Chullah hoods, Chajjas, troughs and similar items including edges and similar works for fair finished surfaces of concrete complete all as specified and as directed.
Use and removal of steel formwork to Fins, fascias, louvres, parapets and railings for fair finished surfaces of concrete complete all as specified and as directed.
Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including fair finished surfaces complete all as specified and directed.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Slabs supported on walls, beams, columns, landings, shelves and the like complete all as specified.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbishto a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of sides and soffits of Slabs & Chajjas etc. and trimming, cleaning and preparing the surfaces to receive Guniting / Plastering and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian as per manufacturer's instructions and providing pressure Guniting averaging 20mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 mixed with and including Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian @ 5% of weight of cement and finishing surface rough conforming to proper geometrics and disposal and depositing the demolished material out of a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as per manufacturer's instuctions, as specified and as directed. Note: Note: Unit rate quoted shall be deemed to include for cost of providing double scaffolding and safety measures as required and removal of the same on completion.
M & L for Cutting / Chipping the spalling concrete surfaces of sides and soffits of Slabs & Chajjas etc. and trimming, cleaning and preparing the surfaces to receive Guniting / Plastering of area not exceeding 0.5 Sqm and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian as per manufacturer's instructions and providing pressure Guniting averaging 20mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 mixed with and including Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian @ 5% of weight of cement and finishing surface rough conforming to proper geometrics and disposal and depositing the demolished material out of a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as per manufacturer's instuctions, as specified and as directed. Note: Note: Unit rate quoted shall be deemed to include for cost of providing double scaffolding and safety measures as required and removal of the same on completion.
M & L for Cutting / Chipping the spalling concrete surfaces of sides and soffits of Slabs & Chajjas etc. and trimming, cleaning and preparing the surfaces to receive Guniting / Plastering and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian as per manufacturer's instructions and providing pressure Guniting averaging 25mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 mixed with and including Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian @ 5% of weight of cement and finishing surface rough conforming to proper geometrics and disposal and depositing the demolished material out of a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as per manufacturer's instuctions, as specified and as directed. Note: Note: Unit rate quoted shall be deemed to include for cost of providing double scaffolding and safety measures as required and removal of the same on completion.
M & L for Cutting / Chipping the spalling concrete surfaces of Beams, Columns, Fins, Facias, Parapets etc. and trimming, cleaning and preparing the surfaces to receive Guniting / Plastering and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 30mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 mixed with and including Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian @ 5% of weight of cement and finishing surface rough conforming to proper geometrics and disposal and depositing the demolished material out of a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as per manufacturer's instuctions, as specified and as directed. Note: Note: Unit rate quoted shall be deemed to include for cost of providing double scaffolding and safety measures as required and removal of the same on completion.
M & L for Cutting / Chipping the spalling concrete surfaces of Beams, Columns, Fins, Facias, Parapets etc. and trimming, cleaning and preparing the surfaces to receive Guniting / Plastering of area not exceeding 0.5 sqm and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 30mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 mixed with and including Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian @ 5% of weight of cement and finishing surface rough conforming to proper geometrics and disposal and depositing the demolished material out of a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as per manufacturer's instuctions, as specified and as directed. Note: Note: Unit rate quoted shall be deemed to include for cost of providing double scaffolding and safety measures as required and removal of the same on completion.
M & L for Cutting / Chipping the spalling concrete surfaces of sides and soffits of Slabs & Chajjas etc. and trimming, cleaning and preparing the surfaces to receive Guniting / Plastering and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian as per manufacturer's instructions and providing pressure Guniting averaging 40mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 mixed with and including Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian @ 5% of weight of cement and finishing surface rough conforming to proper geometrics and disposal and depositing the demolished material out of a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as per manufacturer's instuctions, as specified and as directed. Note: Note: Unit rate quoted shall be deemed to include for cost of providing double scaffolding and safety measures as required and removal of the same on completion.
M & L for Cutting / Chipping the spalling concrete surfaces of sides and soffits of Slabs & Chajjas etc. and trimming, cleaning and preparing the surfaces to receive Guniting / Plastering of area not exceeding 0.5 Sqm and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian as per manufacturer's instructions and providing pressure Guniting averaging 40mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 mixed with and including Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian @ 5% of weight of cement and finishing surface rough conforming to proper geometrics and disposal and depositing the demolished material out of a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as per manufacturer's instuctions, as specified and as directed. Note: Note: Unit rate quoted shall be deemed to include for cost of providing double scaffolding and safety measures as required and removal of the same on completion.
M & L for preparing newly plastered Wall surfaces by using vaccume based sanding machine and applying two coats of Acrylic Washable Distemper by using auto roller/airless sprayer, over a coat of alkali resistant primer over two or more coats of Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the Wall surfaces complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on wall surfaces by using vaccume based sanding machine, removal of nails and applying upto 1mm thick Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one of alkali resistant primer on wall surfaces complete all as specified and as directed.
M & L for preparing newly plastered wall surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for two coats of white wash on old decorated surfaces of walls, Pillasters etc including necessary preparation by brooming down or steel wire brushing complete all as specified and as directed.
M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer of same manufacturer as that of paint on newly plastered walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces by using vaccume based sanding machine complete all as specified and as directed.
M & L for One coat of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer on old painted surfaces of Walls, pillasters, bands, borders, soffits of chajjas and projections etc including necessary preparation of surfaces by using vaccume based sanding machine, washing, rubbing down and stopping complete all as specified and as directed.
M & L for One coat of aluminium paint on old painted steel surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
M & L for washing, rubbing down and stopping of painted surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer on Walls, pillasters, bands, borders, soffits of chajjas and projections by using vaccume based sanding machine complete all as specified and as directed.
M & L for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for two coats of white wash on old decorated surfaces of ceilings etc including necessary preparation by brooming down or steel wire brushing complete all as specified and as directed.
M & L for two coats of synthetic enamel paint on old painted wooden surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
M & L for two coat of synthetic enamel paint on old painted steel surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
M & L for Writing letters or figures [Block, Roman, Italic or Indian] not exceeding 30 cm high with thick paint to stand out boldly and solidly without showing signs of brush marks complete all as specified and as directed.
M & L for removing Plants with roots by chipping Walls / Beams / Junctions of Vertical Stacks / Water Supply lines or at any other location as directed, applying recommended chemical to prevent growth or plants and making good the disturbed portion with Cement Mortar 1:3 or with PCC 1:2:4, Type B0 [using 12.5 mm graded aggregate] and painting the surfaces to match with existing treatment / finishes and removing debris to a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as directed.
Taking down CI pipes/ PVC SWR of any dia (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed .
Supply and Fixing 150 mm bore Cast iron spun pipe of soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls all as specified and as directed .
Supply and Fixing 100 mm bore Cast iron spun pipe of soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors all as specified and as directed .
Supply and Fixing 100 mm bore Cast iron spun pipe of soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls all as specified and as directed .
M & L for jointing only 100 mm bore cast iron pipes and fittings or AC pipes and fittings, in repairs, with cement joints complete all as specified and as directed.
M & L for jointing only 150 mm bore cast iron pipes and fittings or AC pipes and fittings, in repairs, with cement joints complete all as specified and as directed.
S & F 100 mm dia out let, Cast Iron Floor Trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4, Type B-1 complete all as specified and as directed.
S & F 100 mm bore Cast Iron Nahani Trap with grating including jointing to waste pipe, fixed in cement concrete type B1, 1:2:4 complete all as specified and as directed.
S & F Cast Iron Bends [any radius], diminishing pieces or tapers [larger bore measured] of 150mm bore, for Cast Iron soil / waste / vent pipes complete all as specified and as directed.
S & F Cast Iron Branch pieces of 150 mm bore [any radius], Branch pieces, ['T' or 'Y'] single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed.
S & F Cast Iron Bends [any radius], diminishing pieces or tapers [larger bore measured] of 100mm bore, for Cast Iron soil / waste / vent pipes complete all as specified and as directed.
S & F Cast Iron Branch pieces of 100 mm bore [any radius], Branch pieces, ['T' or 'Y'] single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed.
S & F Stack clamps made out of 50 X 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 150mm dia pipes complete all as specified and as directed.
S & F Stack clamps made out of 50 X 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm dia pipes complete all as specified and as directed.
M & L for One coat of epoxy paint on old painted surfaces of CI Pipes of 150mm dia incuding necessary preparation of surfaces complete all as specified and directed.
M & L for One coat of epoxy paint on old painted surfaces of CI Pipes of 100mm dia incuding necessary preparation of surfaces complete all as specified and directed.
S & F 160mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps complete all as specified and as directed.
S & F 160mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps complete all as specified and as directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps complete all as specified and as directed.
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F 160 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 160 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 75mm outlet PVC [SWR] Floor trap with grating including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] WC Connector with lip ring including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] duck's foot or heel rest including jointing with solvent cement complete all as specified and as directed.
S & F Cast Iron cowls of 110 mm dia complete all as specified and as directed.
Taking down or up steel tubing and connections for 15 mm bore of pipe complete all as specified and as directed.
Taking down or up steel tubing and connections for 20 mm bore of pipe complete all as specified and as directed.
Taking down or up steel tubing and connections for 25 or 32 mm bore of pipe complete all as specified and as directed.
Taking down or up steel tubing and connections for 40 or 50 mm bore of pipe complete all as specified and as directed.
Taking down or up steel tubing and connections for 75 mm bore of pipe complete all as specified and as directed.
Refixing Old serviceable GI water tubing of 15 mm bore, medium grade including provision of all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
Refixing Old serviceable GI water tubing of 20 mm bore, medium grade including provision of all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
Refixing Old serviceable GI water tubing of 25 or 32 mm bore, medium grade including provision of all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
Refixing Old serviceable GI water tubing of 40 or 50 mm bore, medium grade including provision of all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 15 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F 15 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F 20 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 32 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F 32 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 40 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 50 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F 50 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F GI water tubing of 80 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F 80 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 15 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 20 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 50 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 80 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
M & L for cutting holes into or through stone walls built in cement mortar and walls of cement concrete and making good in Cement Mortar 1:3 or Cement Concrete 1:2:4, Type B-1 as required for superficial area over 400 Sq.cm bot not exceeding 0.1 Sqm complete all as specified and as directed.
M & L for cutting holes into or through stone walls built in cement mortar and walls of cement concrete and making good in Cement Mortar 1:3 or Cement Concrete 1:2:4, Type B-1 as required for superficial area over 400 Sq.cm bot not exceeding 0.1 Sqm complete all as specified and as directed.
M & L for cutting holes into or through RCC wall / slab/ chajjas and making good in Cement Mortar 1:3 or Cement Concrete 1:2:4, Type B-1 as required for superficial area over 400 Sq.cm bot not exceeding 0.1 Sqm complete all as specified and as directed.
M & L for cutting holes into or through cement concrete slabs, Chajjas, etc. reinforced or otherwise for superficial area exceeding 500 Sq.cm and not exceeding 0.1 Sqm complete all as specified and as directed.
M & L for cutting holes into or through brick walls built in cement mortar and walls of cement concrete and making good in Cement Mortar 1:3 for superficial area not exceeding 150 Sq.cm complete all as specified and as directed.
M & L for cutting holes into or through cement concrete slabs, Chajjas, etc. reinforced or otherwise for superficial area exceeding 250 Sq.cm and not exceeding 500 Sq.cm complete all as specified and as directed.
S & F 25mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing complete all as specified and as directed.
S & F 32mm outer dia of pipe, 3–layer PP–R Polypropylene random copolymer] concealed pipes of SDR 7.4 [PN–16] UV stabilised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete to walls, ceilings or in floors etc. including testing complete all as specified and as directed.
S & F Rotational Moulded Polyethelene [HDPE] Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 500 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed.
S & F in repair Ball Valves, 20 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe [Minimum Weight 20mm - 210 Grams] etc complete all as specified and as directed.
M & L for supply and application of pre-batched one component polymer modified protective mortar (PMPM) of thickness 12-15mm of Sika Top-122 manufactured by M/s. Sika India Pvt. Ltd. or its equivalent in M/s. Fosroc Chemicals India [P] Ltd or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd.for repair of spalling and damaged concrete in RCC structure and superstructure works including bond coat manufactured by M/s. Sika India Pvt. Ltd. or its equivalent in M/s. Fosroc Chemicals India [P] Ltd or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. Asian for bonding old and new concrete surfaces, necessary tools and machinary, curring, consumables etc. complete all as per manufacturer's instructions as specified and as directed.
M & L for Non-Shrink, Cementitious Micro Concrete using Rendroc RG' manufactured by M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. modified with 12mm graded, clean, saturated surface dry crushed stone aggregate in the ratio as per manufacturer's instructions, laid in average thickness of 80 to 100mm in columns, beams and similar structural members including use and waste of water tight formwork to facilitate pouring of micro concrete complete all as per manufacturer's instructions including providing double scaffolding and safety measures as required and as specified. [Note: Measurement shall be considered for circumference at centerline of core thickness]
M & L for preparing surfaces and applying a coat of Zinc Rich Epoxy Primer [Nito Zinc Primer of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions] to all steel surfaces as antirust agent including providing double scaffolding and safety measures as required and removal of the same on completion complete all as specified and as directed.
M & L for providing additional reinforcement using High Strength Corrosion Resistant Deformed Bars of Grade Fe–500D by checking the diameter of the existing bars, cutting the necessary main reinforcement to the required length with proper development length, tying and binding with 16 SWG black soft annealed binding wire / welding where required / lapping / anchoring with the existing shear connectors / reinforcement so that the additional reinforcement acts monolithically with the existing reinforcement and core concrete complete all as specified and as directed. Note: The shear reinforcement shall also be provided as specified here-in-above in the form of 2 "U" shaped bars if existing shear reinforcement is found deteriorated / diameter of the bars is reduced to form a rigid cage and placing with proper cover block, supports, chairs, spacers etc. Diameter of the new bar shall be equal to the existing bars. Additional reinforcement shall be provided only in case the diameter of the existing bars is found less than 25% of the original diameter.
Supply only integral water proofing compound [ISI marked] of approved make.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, surface finished fair and even without using extra cement, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description including PCC padding of any description and removing rubbish to a distance exceeding 1.50 KM but not exeeding 5.00 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for Plain / Chequered Cement Concrete Tiles of size 300 X 300 mm, 25mm thick, Hydraulically pressed as in Floors, set jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
Note for Serial Item No. 1 to 116: The work shall be carried out up to Sixteen Storey height and the rates quoted are deemed to be including providing double scaffolding and safety measures as required and removal of the same on completion complete all as specified and as directed. Nothing shall be paid extra on this account.
P SRINIVASA RAO
SRI SIMHADRI COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .