Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC H NO 963 10 STREET NO 5 DEEP NAGAR CIVIL LINES LUDHIANA 141001 PUNJAB | LUDHIANA | LUDHIANA | PUNJAB | 141001 | L1 | Accepted-AOC lowest | |
| 2 | L2₹24.1 L+₹66,757.25 (2.85%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹24.1 L+₹74,264.84 (3.17%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹25.9 L
EMD Value
₹51,900
Closing Date
3 Jun 2024, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001 (Punjab)
Special repairs to Bldg No T-3 and P-16 at Doraha and roof treatment to Bldg No P-92/A at Dholewal under GE Ludhiana
2024_MES_652435_1
GE/LDH-08/2024-25
Open Tender
Civil Works
Item Rate
180 days
Dholewal Cantt and Doraha
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹51,900
Yes
15 Jul 2024
6 May 2024
5 Jun 2024
6 May 2024
3 Jun 2024
21 May 2024
6 May 2024 - 20 May 2024
Amount
Demolition of cement concrete (unreinforced) concrete in ground floors and paving n-exc 15cm thickness (below or above ground floors complete all as specified
M&L PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges including formwork/moulds complete all as specified and directed by Engr-in-Charge.
M/L 75 mm thick PCC 1:3:6 type C2 (40mm graded crushed stone aggregate) as in plinth protection and paving finishing surface even and smooth without using extra cement all as specified and directed.
M&L machine cut kota stone 18-22 mm thick as in slab, flooring & tread of steps edges rounded over and including 15mm thick cement screed bed in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and granite polishing complete all as specified and directed by Engr-in-Charge.
M&L, 75mm thick PCC 1:4:8 Type D-2 using 40mm crushed stone aggregate as in sub base of floor complete all as directed & specified by Engineer-in charge .
M&L for fine sand filling under floors or in foundations complete all as directed & specified by Engineer-in charge (consolidated thickness shall be measured and paid) .
M&L 60mm thick interlocking paver block with grey cement and pigment of any size and shape confirming to IS 15658-2006, M-35 Grade as approved laid in flooring and joints filled/broomed with fine sand complete all as directed & specified by Engineer-in charge .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing, serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment to match over and including15mm thick screed bed in cement mortar (1:6) complete all as specified and directed by Engr-in-Charge.
M&L glazed ceramic coloured/ printed tiles of size 450mm x 300mm x 7mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick bedding layer in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed by Engr-in-Charge.
Demolition of brickwork built in cement or cement lime mortar incl all quoins, arches, pillars, etc but excl ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge.
M&L brick work with fly ash bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:4 complete all as specified and directed by Engr-in-Charge.
All as per item No 12 above item but except brick complete all as specifed and directed. (Old bricks shall be reused)
Taking down chowkats or frames(without taking off shutters from the frame) area n.exc 1.5 Sqm each complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4.0 Sqm with shutters (without taking off shutters from the frame) complete all as specified and as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube suppling & fixing in opening as per specification and drawing complete all as specified and directed by Engr-in-Charge.
S&F factory made soilid panel PVC Door shutter 30mm thick (Stype) consisting of frame made out MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having PVC sheet stripof 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail, & bottom rail; Panneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing complete all as specified and directed by Engr-in-Charge.
Supply and Fix steel ventilators, fixed type with glazing bars complete all as specified and directed by Engr-in-charge.
M&L for 3mm thick Sheet glass, ordinary quality and glazing with silicon sealant in square n exc 0.5 sq.m in each pane complete fixed in repair all as specified and directed by Engr-in-Charge.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium handles, cast type, anodised 150mm long complete all as specified and directed.
S&F 100mm size Butt hinges, medium weight, cold rolled mild steel bright finish complete all as specified and directed by Engineer-in-Charge.
S&F 150mm aluminium anodised tower bolts of extruded section fixed with screw, complete all as specified & directed by Engr-in-charge.
S&F in Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolts 200 mm complete all as specified and directed.
Taking down eaves gutters and rain water pipes CI/PVC ,110 mm/75mm including all fittings and size and pattern complete all as specified & directed by Engineer-in- charge.
Supply & fixing 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvent laid in trenches complete all as specified & directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bend 110mm bore of any radius complete all as specified & directed by Engineer-in- charge.
Supply & fixing 75mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, jointed with solvent laid to trenches complete all as specified & directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bend 75mm bore of any radius complete all as specified & directed by Engineer-in- charge.
S&F for PVC (SWR) floor trap, plain with grating 75mm diameter of outlet, setting and jointing with solvent cement complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified & directed by Engr-in-charge.
M&L rendering 12mm thick on brick work or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified & directed by Engr-in-charge.
M&L rendering 15mm thick on brick work or concrete surface in cement mortar (1:4) and finished even and smooth without using extra cement complete all as specified & directed by Engr-in-charge
M&L prepration of newly plastered surface of walls and applying two coats of cement base paint complete all as specified & directed by Engr-in- charge.
M&L Preparing of new plastered surface walls and applying three coats of white wash complete all as specified and directed.
Taking up or down steel tubing 15mm bore and connections, including removal to store complete all as specified and directed by Engr-in-Charge.
All as per item No 36 above item but 20mm bore all as specified and directed.
S&F 15mm GI tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr-in-Charge.
All as per item No 38 above but 20mm bore all as specified and directed.
S&F in repair viterous china squating pan orrisa pattern , size 580x 440mm white, interged foot rest including 110mm PVC (SWR) 'P' trap,connection to trap and to flush pipe, anti syphonic pipe etc complete making good to floor complete all as specified and directed.
S&F in repair PVC low level flushing cistern syphonic action type white with inlet ball valve, handle including brackets 10 ltrs capacity and flush pipe to squat patter closet including all joints and making good to the floor etc. all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC connections 15mm size with PTMT nuts and bolts of length 450mm etc complete all as specified and directed
S&F vitreous china urinal,bowl type size of 465x335x265mm (back or corner wall type) complete incl providing and fixing plugs beding urinal against wall in CM 1:2 security urinal plug with and incl 60mm long brass screws pointing around urinal back in cement fixing automatically flushing cistern with bracket, flush pipes grating and union for discharge pipe fixed complete all as specified.
S&F in repairs Bib taps, cast copper alloy with crutch or butterfly handle fancy type, screwed down , screwed for iron pipe or for brass ferrule and fixed in iron pipe of 15 mm bore complete all as specified and directed.
S&F in repair stop valves/angle valve 15mm bore , cast copper alloy fancy type, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed etc complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves of bore 20 mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge.
Dismantling Asbestos cement corrugated sheet in roof covering complete all as specified.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Dismantling timber scantlings (Framed work) 40 sq. cm and over in section, in any position complete all as specified.
M&L roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc conforming to Fe 290 (Gde E-165) quality A all as specified and as directed by Engr-in-Charge.
M & L for preparation of new or previously untreated steel surface of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge.
M&L precast reinforced cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in manhole covers and the like set in cement mortar (1:4) duly placed on manholes including formwork/moulds complete all as specified and directed by Engr-in-Charge.
M&L TMT bars 10mm dia and over cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engr-in- charge.
Excavation in trenches n. exc 1.5 metre wide for foundations etc. and not exceeding 1.5 m deep and getting out in soft/ loose soil complete all as specified & directed.
Demolition and breaking up 150mm bore drain pipes (salt glazed stoneware, AC or reinforced concrete) set in cement mortar including bedding and haunching complete all as specified & directed by Engineer-in- charge.
M&L cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in bed to 150mm bore drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified & directed.
M&L 150mm bore reinforced concrete pipe class NP3 laid in trenches including jointing & testing with collars complete all as specified & directed.
Returning filling in soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified & directed by Engineer-in-charge.
Removal of excavated surplus soil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
M&L rendering 15mm thick on brick work or concrete surface in cement mortar (1:4) finished even and smooth without using extra cement mixed with liquid water proofing coompound complete all as specified & directed by Engineer-in- charge. Note: WPC shall be measured and paid separately.
Supply only liquid water proofing compound ISI marked as approved.
M&L rendering 5mm thick in cement mortar (1:3) on ceiling/ soffit of slabs finished even and smooth without using extra cement complete all as specified & directed by Engineer-in- charge.
M&L preparing newly plastered or pointed surface of ceiling and applying three coats of white wash complete all asspecified & directed by Engineer-in-charge.
Dismantling water tanks exc 250 & nexc 500 ltr complete all as specified and directed
S & F in repairs brass ball valves high pressure with polythylene float and fly nut complete screwed for iron pipe fixed 20mm dia etc complete all as specified and directed by Engr-in-Charge.
S & F rotational moulded polyethylene water storage tanks triple layered of capacity 500 ltr (cylindrical vertical with closed top) hoisted and fixed in position including nipple suitable for water tank complete all as specified and directed by Enigneer-in-charge.
M&L rendering 10mm thick on roof surface in cement mortar (1:3) mixed with water proofing compound finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge (supply only water proofing compound shall be measured and paid for separately under appropriate items of this schedule)
M&L applying evenly a bitumen tack coat of industrial bitumen 85/25 @ 1.2 kgs/Sqm incl cleaning surfaces complete all as specified and directed by Engr-in-Charge.
M&L Priming surfaces and applying normal treatment (for moderate conditions) using bitumen primer @ .30 Kg/Sqm applied hot complete all as specified and directed by Engr-in-Charge.
M&L providing APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150gms/Sqm) laid on primed surfaces by forced application APP based polymeric membrance complete all as specified and directed by Engineer-in-Charge.
M&L for applying a two coats of water proofing paint with aluminium paint above APP based polymeric membrance complete all as specified.
Dismantling brick tiles or terracing tiles sinlge layer including any treatment on roofs complete all as specified.
Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part there of) and removing from outside of defence land complete all as specified.
M&L for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate average thickness 50mm as in roof padding incl mixing water proofing compound as per manufacturers instruction complete all as specified and as directed. Note. water proofing liquid shall be measured and paid seperately)
M&L rendering 15mm thick screed bed or bedding layer of CM (1:4) finished even and fair for laying floor finishes complete all as specified and directed
M&L 40mm thick brick tiles laid on Screed bed of cement mortar (1:3) 15mm thick finished even and fair and joints grouted flush in cement mortar 1:3 mixed with 5% 0f crude oil by weight of cement completed all as specified.
All as per item No 79 but except tiles complete all as specified and directed.
Removing mortar from and cleaning bricks, stacking for measurement including all extra handling and removal and disposing off rubbish off the premises complete all as specified.
Racking out joints/Pointing to brick work in walls or to brick on edges in floors channels roofs etc complete all as specified and directed.
M&L for flush pointing to brick work in roof in cement and sand mortar (1:3) complete all as specified and directed.
M&L Brick work with sub class 'B' bricks straight or curved in plan exc 6cm mean radius built in CM 1:6 complete all as specified.
Taking down carefully the point wiring (light, Fan, socket or power) complete, (incl fittings such as switches, sockets any type, ceiling roses, pandents, light fittings, etc for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified & directed by Engineer-in-charge.
M &L Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through and including 20mm dia PVC rigid non metallic conduit with all accessories such as internal bend end caps etc complete concealed in walls/ceiling/roof/etc including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor, all as specified and as directed for the following :-
One ligth point controlled by one switch with cables 1.5 sqmm size.
One celing/Exhaust fan point controlled by one switch with cables 1.5 sqmm size.
One 3 pin socket outlet,5 amps,independent,with cables 1.5 sqmm size.
One 3 pin socket outlet 5 amps on same board with other switches,with cables 1.5 sqmm size.
All as per item No.86 here in before but 2.50 Sqmm copper conductor wiring with 2.50 Sqmm copper conductor as earth continuity for 15/16 Amps socket outlet on independent board all as specified & directed by Engineer-in-charge.
Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals complete all as specified and as directed by Engineer-in-charge
Supply and Fix Switch Piano,Flush type single pole , one way 5 Amp complete all as specified and as directed by Engineer-in-charge.
Supply and Fix Socket outlet 3 pin, 5 A Piano,Flush type complete all as specified and as directed by Engineer-in-charge.
M&L Socket outlet multi purpose 3 in 1, 6 pin, 5 & 15 Amps piano, flush type complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement LED tube light fittings 1200 mm, 20W, 240V, 50Hz,rated input current- 0.070-0.110, rated input watt 20, operating voltage range- 140-270, P.F- not less then 0.95, surge protection upto- 4Kv, IP20, THD shell be less then 10%, CCT- (k0)- 6500ANSI, higher energy saving decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviromental friendly, energy efficient complete all as specified and directed by Engineer-in-charge..
S&F in replacement lamp holder PVC/ Polycarbonate type with cord grip cap, insulated body, threaded dome pattern, suitable for pendant fittings all as sepecified and directed by Engineer-in-charge.
S & F in replacment of existing light fitting with Water tight bulk head LED 10 Watt light fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed by Engineer - in - Charge..
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engineer-in-charge.
S & F in replacement of factory made sheet metal enclosures SPN 8 way double door 240 v for DB,s suitable for having MCB flush with wall complete all as specified and directed by Engineer-in-charge.
S & F in replacement of amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 A carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and as directed by Engineer-in-charge.
S & F in replacement of MCB SP 6-32 Amps240 V, C- curve, 50 Hz, breaking capacity-10 kA . complete all as specified and directed by Engineer-in-charge.
M &L Earthing incl earth work complete with galvanised steel earth plate electrode 60cm X 60 cm X 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with the top edge of electrode not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron and GI lead protected with protection pipe of GI light grade 15mm bore upto 3mtr above ground level along poles fixed with two clamps of 25mm 3mm flat iron and connected to running earth wire at top of poles and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and direct and testing on completion including PCC 1:3:6 ) C-I cover and frame excavation and earth work etc complete all as specified in elect plate No 3 of SSR Part -I 2009 Note :- PCC Chamber shall be constructed at least 1.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
Supply and fixing in replacement building security light fitting LED 30/35 W LED made up of pressure die cast aluminium housing with potted isolated driver and high power LED and indl lenses, operating range- 90V to 340V AC. , IP66 with high power LED lamp compete all as specified and directed by Engineer-in-charge.
M & L in replacement Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc all as specified and as directed by Engineer-in-charge.
M & L in replacement XLPE insulated heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 16sq mm 2 core complete all as specified and directed by Engineer-in-Charge.
Supply and spreading of fine river sand and gentally punning for laying of under ground cables complete all as specified and directed by Engineer-in-Charge. Note :- Punned thickness 18cm shall be measured for payment.
Supply and laying sub class 'B'common burnt bricks, old size designated 75, laid dry flat with width equal to length of brick & with gaps between the adjucent bricks n.exc 10mm as cover laid over the cable to give mechanical protection to under ground cable complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of GI tubing galvanised light grade of size 50 mm bore with all fittng and fixed complete to wall, floor and ceilling or laid in trenches (for protection UG cables) complete all as specified and directed by Engineer-in-Charge.
JAI DURGA CONSTRUCTION COMPANY
GURPARTAP SINGH GULATI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .