ARC (Annual Rate Contract) for routine maintenance and servicing of HT/LT equipments control panels for Water Supply Scheme at Notified Area GIDC, Sachin Estate 2026-27.
295277
01 of 2026-27(Serial No. 7)
Open
Electrical Works
Works
Surat
14 documents required · 14 mandatory
₹2,832
Chief Officer, Sachin Notified Area
₹68,610
10 Apr 2026
10 Apr 2026
10 Apr 2026
24 Apr 2026
10 Apr 2026
Name ARC (Annual Rate Contract) for routine maintenance & servicing of HT/LT equipment’s, control
Of panels for Water Supply Scheme at Notified Area GIDC, Sachin Estate 2026-27.
RATE/ NET RATE/
Sr. No. DESCRIPTION OF ITEM QTY. UNIT
UNIT in RS. UNIT in Rs.
PART - A Labour Works
Labour charges for Round the clock Routine Preventive Maintenance of
below Panels. It includes the Attending the fault and Complete Control
Panels Servicing / Repairing /Cleaning of all panels with checking of all
the terminals of Star Delta Connectors/Over load Relay/Single Phase
Preventer /Timers/ Auto Transformer. Checking of all the Lugs & Nut-
1 bolts condition and if found unhealthy then cleaning of all the Rust and
Deposited Carbon on faulty Terminal. It means the job include the
Complete Repair & Maintenance of all the panels per month or as an
when required with all contact kits Cleaning, Tightening of
Connections, Power & Control wiring repairing / Replacement of panel
accessories (if required)
a up to 5HP 60.00 Job 306.84
Labour charges for Round the clock Routine Preventive Maintenance of
below variable frequency drive. It includes the Attending the fault and
Complete variable frequency drive Repairing/Servicing /Cleaning of all
Drive with checking of all the terminals of VFD/Over load Relay/Single
Phase Preventer /Timers/ Auto Transformer. Checking of all the Lugs &
2 Nut-bolts condition and if found unhealthy then cleaning of all the Rust
and Deposited Carbon on faulty Terminal. It means the job include the
Complete Repair & Maintenance of all the variable frequency drive per
month or as an when required with all contact kits Cleaning, Tightening
of Connections, Power & Control wiring repairing / Replacement of
VFD accessories (if required)
a Drive, Make- ABB 75 HP 24.00 Job 1309.71
b Drive, Make- ABB 30 HP 24.00 Job 1309.71
c Drive, Make- ABB 10/15 HP 12.00 Job 1309.71
d Drive, Make- Yaskawa F7 60 HP 60.00 Job 1746.27
e Drive, Make- Yaskawa F7 120 HP 12.00 Job 1746.27
Labour Charges for Servicing of 11KV 4 Pole / 2 poles DP Structure
with GOD switch / Do fuse unit / CTPT jumper with required
Maintenance like Servicing of Repairing / Oiling /Gresseing of Male
Female Contect of A.B. Switch inclusive of Discaling /Pitting of the fix
3 and moving Contacts. Servicing & Maintaining ACSR Conductor along 4.00 Job 20455.86
with its end connection for healthy condition. Cleaning & checking of
Lightning Arrestor Power & Earth terminals using conductivity
insulation resistance meter. Insulation Resistance Testing of all
insulators with 1000/2000 Meggar.
Routine Maintenance of 500 to 1000KVA Transformers. It includes the
Checking/ Servicing/ Maintenance of H.V. /L.V. Cable End Termination
and if required then replacement of H.V. / L.V. Side Lugs with Proper
4 Method with Required Tools like Crimping Machine. The Job also 4.00 Job 8635.95
includes the checking of Oil Level of Transformer/ Silica Gel Brether
Condition/ Day-farm Condition and attending the outside oil leakage
faults if found with replacement of Outer Side Gasket if necessary.
Labour Charges for Routine Maintenance / servicing of 1600Amp /
800Amp ACB LT Panel. It includes the Removal of old Grease and re-
greasing the same with recommended grease. Check condition of arcing
contact and gap between fixed and moving arcing contracts shall be
5 checked. Checking condition and alignment of jaw Contact. Checking 12.00 Job 21459.03
proper closing of all poles together. Checking the reset mechanism,
tripping of breaker through push button. Checking tripping of VCB
through protection release. Checking presence and proper tightening of
hardware. Checking condition of ACB wiring and replace if required.
Labour Charges for Routine Maintenance / servicing of various MCCB.
6 The Process includes the Complete Overhauling & Maintenance of 52.00 Job 2398.88
MCCB with cleaning of all contacts/ tightening of all hardware.
Labour Charges for Routine Maintenance / servicing of APFC Panel.
The Job includes the Checking of Operation of APFC Relay. End
Termination of all Capacitors in the Panels and condition of capacitors
with required equipment’s. And then after the re-installation of all
capacitors at appropriate compartment of APFC Panel & charge the
SITC of Advance Maintenance Free Earthing System: 48 MM Diameter,
made from low carbon steel pipe, wall thickness 3.2 MM, ISI Marked,
Copper Bonded, with 2 Nos. of Stainless Steel Nut & Bolts, Suitable for
Lug Size 40 MM x 6 MM x 100 MM, and cross section area 481 mm2,
to be used with Premium Grade Ground Improving Earthing Compound
in appropriate quantity.
Labour Charges for Earthing Resistance measurement with proper
method using Earth Resistance Meter.
Labour Charges for Transformer Painting with Compressor Spray
Painting. The process includes the proper di-scaling of rust from each &
every part of Transformer & then after paints the Transformer with Heat
Resistance Paint as per Standard Norms.
Labour Charges for 4pole / 2 pole DP structure painting. The process
includes the proper di-scaling of rust from each & every part of 4 Pole/
2 Pole Structure and then after paint 1 Coat of Red Oxide and 2 Coat of
Silver Paint with required manpower & materials.
PART-B SITC of Material
providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity
10 KA to be erected in existing box. confirming to IS 8828/1996 with
Supplying & erecting directly operated single phasing preventer
complete erected and connected to supply up to 45 Amp. Range.
Supplying and erecting Ammeter / Voltmeter selector switch for 3 phase
AC Supply 500 V on existing panel board with necessary connections.
Supplying and erecting approved make suitable panel indicator LED
type lamp, lens cover, complete erected with necessary connections.
17 SITC of Push button with elements 25.00 No. 175.81
18 SITC of Electronic Timer 5.00 No. 1318.59
SITC of Electronic Overload Relay with auto scrolling & all protection
20 SITC of 63A Contactor MNX400 L&T make 10.00 No. 6769.97
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 25 KA. at 415 V,having normal
current rating up to 25 A to 100A. with Fixed thermal & magnetic release
suitable to work on A.C. supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 35 KA. at 415 V. having
normal current rating 125A. with Fixed thermal & magnetic release
suitable to work on A.C.supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 35 KA. at 415 V. having
Normal current rating 200A.with variable Thermal & magnetic release
suitable to work on A.C.supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing 16 G.M.S.housing
ICS=100% of ICU only
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 35 KA. and above at 415 V .
having normal current rating 250A. with variable thermal & magnetic
release suitable to work on A.C.supply 50 c/s. with all internal
connections, spreader tinned copper & complete erected in existing
G.M.S. housing. ICS=100% of ICU only Cat III
SITC of Approved make Four pole moulded case circuit breaker having
breaking capacity ICU of 50 KA and above at 415 V having Normal
current rating up to 320A with variable Thermal & magnetic release
suitable to work on A.C. supply 50 c/s. With all internal connections &
complete erected in existing 16 G.M.S. housing.ICS=100% of ICU only
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 50 KA and above at 415 V
having Normal current rating 400A. with variable Thermal & magnetic
release suitable to work on A.C.supply 50 c/s. With all internal
connections, spreader tinned copper & complete erected in existing
G.M.S. housing. ICS=100% of ICU only Cat III
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 50 K.A. and above at 415 V
having normal current rating 800A.with variable thermal & magnetic
release suitable to work on A.C.supply 50 c/s. with all internal
connections, spreader tinned copper & complete erected in existing
G.M.S.housing. ICS=100% of ICU only Cat III
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load
28 (C Curve) having 10KA breaking capacity & confirms to IS :8828 in
existing box having following capacity
a (a)6 to 32 Amp. Cat.III 4.00 Ea. 471.67
b (b)40 Amp. Cat.III 6.00 Ea. 488.84
c (c)63 Amp. Cat.III 8.00 Ea. 587.82
Providing and erecting Approved make Three pole moulded case circuit
breaker having breaking capacity ICU of 25 K.A. at 415 V having
normal current rating up to 25 A to 100A. with Fixed thermal & magnetic
release suitable to work on A.C. supply 50 c/s. with all internal
connections, spreader tinned copper & complete erected in existing
G.M.S. housing. ICS=100% of ICU only Cat III
Providing and erecting AC-3 duty 3 pole power contactors spare kits (L
& T, C&S, BCH,T.C. Siemens, make).
a (a) for 25 / 32 A rating 6.00 Ea. 3253.21
b (c) for 60 / 70 A rating 10.00 Ea. 8141.61
Supplying and erecting Direct On-line Electronics Starter with 2-5/4-
10/8-14/10-16 Amp. Rating relay (variable current setting) directly
operated in totally insulated elegant enclosure and 18 Amp. Rating
power relay with start - stop button for single phase operation up to 3 HP
as per complete erected on P.W. Block with following features. Low
voltage cut off below 140 V High voltage cut off above 280 V Overload
protection Indicating LEDs for motor on lv, hv & overload tripping.
Supplying and erecting Direct on line starter with 30 Amp. (resistive @
230v) power relay and with 2 to 5/ 4 to 10 / 8 to 20 amp. Range C.T.
Operated electronic overload relay in engineering grade plastic enclosure
for 3 ph 415v 50 HZ A.C. motor up to 7.5 HP with high voltage
protection (above 480 v) and under voltage protection (below 330 v)
current sensing single phasing protection. Reverse phasing protection,
inverse current characteristic overload protection with indication for On,
OL, HV,LV SPP in a single unit with feather touch start / stop push
button, high temperature with standing Bakelite terminals complete
erected on P.W. Block with necessary connection [Cat II]
Supplying and erecting push button operated fully automatic Star-Delta
starter with 3 Nos.of 32A. rating contactors and. 1 No. of directly
33 operated thermal overload relay having 20-32A range in sheet steel 8.00 Ea 12069.5
enclosure for 3 phase 415V. 50 c/s. A.C. motors up to 35 H.P. complete
erected on (a)P.W. Block with necessary connection Cat.III
Supplying and erecting push button operated fully automatic Star-Delta
starter with 3 Nos. of 95A. rating contactors and. 1 No. of directly
34 operated thermal overload relay having 45-85A range in sheet steel 2.00 Ea 20895.63
enclosure for 3 phase 415V. 50 c/s. A.C. motors up to 60 H.P. complete
erected on (a)P.W. Block with necessary connection. Cat.III.
35 SITC of 25KVAR Capacitor 10.00 No. 11537.59
36 Neutral Link for (i) 32/63/125 Amps 30.00 Ea 137.36
Providing and erecting following additional parts for panel mounting
37 MCCBs (A)Extended operating rotary handle with pad lock with three 8.00 Ea. 873.65
position trip,off,on suitable for 25A to 250 A panel mounting cat-III
SITC of Providing and erecting following additional parts for panel
mounting MCCBs (B) Extended operating rotary handle with pad lock
with three position trip, off, on suitable for 400A to 800A panel
Supply of Approved make Iron Clad or metal clad four pole change over
switch 415V. confirming to IS of following capacity (B) 400 A Cat-lll
SITC of Approved make Iron Clad or metal clad four pole change over
switch 415V. confirming to IS of following capacity up to 450 A Cat-lll
Providing & erecting additional parts for Air Circuit Breakers as follows:
(A) Auxiliary Contact Block for CN-CS 800 to 2500 & 2 NO + 2 NC
Supplying & erecting 20 Amp 10 KA ‘C Curve’ single pole MCB with
20 Amp. Plug socket, company fabricated powder coated sheet steel
enclosure erected as directed with connection. [A] Metal Clad Socket
with metal clad top
Providing and fixing approved make Perforated C type cable tray. Made
from sheet steel. The cable tray should be single or double bended as per
required and as per IS 2062/1079 and shall be coated with hot dip
43 galvanizing as per IS 2629/4759. with max 17.5% perforation with 250.00 RMT 622.16
coupler plate / Fish plate and GI hardware like nut - bolt and washers etc.
erection with necessary support( included) as per Specification and as
per instruction of engineer in charge..(5) 300 X 50 X 2.0 mm Thick
Transformer oil having good resistance to high electrical stress, high di-
electric strength (50KV) low viscosity, low pour point, high flash point
and excellent thermal properties for efficient heat transfer and cooling as
Filtration of transformer oil as per I.S. for removal of moisture, carbon.
slurry etc.by means of circulating oil through vacuum pump from
heating elements and filters to with stand the breaking strength of the oil
above 40KV beyond one minute tested in oil testing Kit. (A) on site.
Replacing old and unserviceable gasket of Top cover plate of
Transformer having following capacity. (D)750 KVA
Replacing the breather of the Transformer of following capacity. (B)
KVA/750 KVA/1000 /1250 KVA
48 Inside painting of 250/ 315 / 500 / 750 / 1000 /1250 KVA transformer 5.00 Ea 1456.42
Outside painting of Transformer for the following capacity (B) 750 /
Supplying rubber matting of following thickness as per IS:15652/IEC
Providing and fixing printed instruction chart both in English and
51 Gujarati and duly framed with front glasses, for treatment of person 5.00 Ea 130.29
suffering from Electric shock with minimum 50" diagonally size.
Supplying & erecting ABC powder type 'Ceasefire' type Fire
52 extinguisher as per IS 13849 or 1 Kg capacity with necessary clamp for 6.00 Ea 848.4
erection on wall
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
53 multistrand Aluminium conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of following size of cables
a (I) 3 1/2 core 240 Sq. mm (120 Sq. mm 1/2 core) 100.00 Mtr 1168.57
b (K) 3 1/2 core 400 Sq.mm ( 185 Sq. mm 1/2 core) 250.00 Mtr 1747.3
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
54 multistrand Aluminium conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of following size of cables.
a (C) 3 core 6 Sq. mm 200.00 Mtr. 107.06
b (D) 3 core 10 Sq. mm 300.00 Mtr. 131.3
c (E) 3 core 16 Sq. mm 309.00 Mtr. 143.42
d (G) 3 core 35 Sq. mm 300.00 Mtr. 190.89
e (I) 3 core 70 Sq. mm 260.00 Mtr. 321.18
f (k) 3 core 120 Sq. mm 250.00 Mtr. 500.96
Providing & erecting Switch board for Computer or electric apparatus
consisting of following modular type accessories mounted with PVC /
Metallic concealed/open box with single mounting base frame covered
55 with textured/metallic /white front plate,modules erected with necessary 8.00 Ea 1133.22
connections as directed 1) 1 no. 6A/16A universal plug-switch
combined. 2)3 nos. 6A Switch 3). 3 nos. 6A 5 pin Plug For Modular
Type Accessories
Supplying and erecting LED indoor fittings with LEDs of wattage
Watt to 0.5 Watt assembled on single MCPCB, with housing used as a
heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company mark/name 160V to
270V, Power Factor more than 0.95, THD < 15%, CCT 3000 K to
6500K, Luminaire efficacy> 85 lumens/watt ,LED driver efficiency >
% ( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the ranges
shown.)(A) Tube Light with integral driver (iv) 22-24 Watts, Surge -
2KV,IP-20, conventional 4 feet
Providing & erecting Approved make Ceiling Fan with double ball
bearing ISI mark with condenser A.C.230V 50c/s. 1400 mm. sweep
complete, canopy erected on existing hook or clamp with earthing [
Make shall be approved by Engineer in Charge]
Providing Fan clamp of 30 x 5 mm flat of required length & 10 mm M.S.
Bolt & Nuts erected with necessary hook of 10 mm M.S. Round Bar.
Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or
Point wiring for Light / Fan/ Bell/ Primary Point with 2-1.5 sq. mm &
earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade
FRLS PVC insulated multi strand copper wires upto max length of
mt, in below type of pipe erected with 6A Tissino Type ISI marked flush
60 type switch / bell push and accessories erected on Metal / PVC/Wooden 26.00 Pt 387.84
Box covered with 3 mm thick PC(Polycarbonate) /Acrylic/Laminated
sheet. with necessary Lamp holder/ceiling rose / H.D.Connector as
directed.(a) with medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete
61 SITC OF 11KV 400Amp AB Switch 1.00 Nos. 28745.4
62 SITC OF 11KV DO Fuse Unit 1.00 Nos. 19472.69
63 SITC OF 1000KVA Transformer Radiator 2.00 Nos. 39872.65
SITC Of various spare part of ABB ACS 550 -125A MAKE 75HP VFD
AS and where Required as Below
a Diode Module 109A 6.00 Nos. 2837.7
b Capacitor Bank 8.00 Nos. 2837.7
c SMD Components 6.00 Set. 1004.11
d Control Card 2.00 Nos. 8294.8
e Semi Conductor Fuse 200A 2.00 Nos. 2182.84
f IGBT Module 200A 6.00 Nos. 6548.53
g IN Put Chock 300A 2.00 Nos. 10914.2
h Firing ICS 12.00 Nos. 436.57
i Power Board 2.00 Nos. 19645.57
j SMD & Firing Spares 10.00 Nos. 1309.71
SITC Of various spare part ABB ACS 550 MAKE 30HP VFD AS and
where Required as Below
a Diode Module 50A 2.00 Nos. 4191.06
b Capacitor Bank 16.00 Nos. 873.13
c SMD Components 6.00 Set. 1004.11
d Control Card 2.00 Nos. 7421.66
e Semi Conductor Fuse 200A 2.00 Nos. 2182.84
f IGBT Module 100A 2.00 Nos. 8294.8
g IN Put Chock 150A 2.00 Nos. 6548.53
h Firing ICS 12.00 Nos. 436.57
i SMD & Firing Spares 4.00 Set. 9167.93
j Power Board 2.00 Nos. 1309.71
SITC Of various spare part of ABB ACS 550 MAKE 10/15 HP VFD
AS and where Required as Below
a Diode IGBT Module Single Pack 40A 1.00 Nos. 5937.33
b Capacitor Bank 6.00 Nos. 873.13
c SMD Components 3.00 Set. 1004.11
d Control Card 1.00 Nos. 7421.66
e Firing ICS 6.00 Nos. 436.57
f Power Board 1.00 Nos. 6548.53
g IN Put Chock 300A 1.00 Nos. 4802.25
SITC Of various spare part of Yaskawa F7 Make 60 HP VFD AS and
where Required as Below
a Diode Module 53A 15.00 Nos. 4889.56
b IGBT Module 200A 15.00 Nos. 8120.17
c Firing ICS 30.00 Nos. 240.12
d SMD Components 15.00 Set. 1527.99
e Semi Conductor Fuse 200A 5.00 Nos. 1527.99
f Electrolightic Capacitor 3000 MFD, 400 Volt 20.00 Nos. 1964.56
g Power Board 5.00 Nos. 21391.84
h Control Card 5.00 Nos. 10914.2
i Capacitor Bank 30.00 Nos. 2837.7
SITC Of various spare part of Yaskawa F7 Make 120HP VFD AS and
where Required as Below
a Diode Module 6.00 Nos. 4889.56
b IGBT Module 200A 12.00 Nos. 8120.17
c Firing ICS 6.00 Nos. 240.12
d SMD Components 3.00 Set. 1527.99
e Semi Conductor Fuse 900A 1.00 Nos. 7421.66
f Electrolightic Capacitor 4000 MFD, 400 Volt 8.00 Nos. 3710.83
g Power Board 1.00 Nos. 24884.39
h Control Card 1.00 Nos. 12660.48
69 SITC of DO Wire 12.00 Kg. 569.39
70 SITC of Lugs various type Size 200.00 No. 122.02
SITC of Nut-Bolt(SS) full threaded with double washer Various type
pump set & panels
SITC of Nut-Bolt(MS) full threaded with double washer Various type
pump set & panels
SITC of Nut-Bolt(GI) full threaded with double washer Various type
pump set & panels
SITC of Knife / Blade / DIN type HRC fuse link capable to withstand
74 K.A. confirms to I.S. 13703 for following current capacity (B) 63 Amp 12.00 Ea. 363.6
to 100 Amp (Size 00 )
75 SITC of Internal Lock Various panel 4.00 No. 1464.14
76 SITC of AC to DC converter 4.00 No. 1626.83
Microprocessor Based LV Variable Frequency Drive, Suppl,
installation, testing & commissioning of 415 V Fully automatic
microprocessor based Variable Frequency drive for pump control
application as per general specification as under: The VFD unit shall
have modular construction, 6 Pulse Bridge rectifier, speed control by
means of sensorless vector control (open loop), high torque at low
frequencies, locking at high and low frequency settings, In-built PID
control, frequency accuracy of ± 0.1 % (min), frequency resolution of ±
0.1 Hz (min), protections against; a) overload (motor and drive), b) short
circuit, c) ground fault, d) input / output phase loss (open circuit), e)
stalling, f) input / output undervoltage (momentary power loss restart),
g) input / output overvoltage,h) over-frequency, i) Input surge, j) over
temperature of heatsink, k) loss of remote speed signal etc. The VFD
shall also have userfriendly programming software & it shall be capable
of at least two level parameter setting with password lock for critical
parameters,rogramming for I/Os, speed search function, copy
parameters (upload / download) to other identical unit, tuning to energy
saving mode (maximum efficiency), event / fault recording (last 5 faults
in non-volatile memory) & RS 485 communication port (MODBUS
RTU protocol) with required software., - 45 kW
Microprocessor Based LV Variable Frequency Drive, Suppl,
installation, testing & commissioning of 415 V Fully automatic
microprocessor based Variable Frequency drive for pump control
application as per general specification as under: The VFD unit shall
have modular construction, 6 Pulse Bridge rectifier, speed control by
means of sensorless vector control (open loop), high torque at low
frequencies, locking at high and low frequency settings, In-built PID
control, frequency accuracy of ± 0.1 % (min), frequency resolution of ±
0.1 Hz (min), protections against; a) overload (motor and drive), b) short
circuit, c) ground fault, d) input / output phase loss (open circuit), e)
stalling, f) input / output undervoltage (momentary power loss restart),
g) input / output overvoltage,h) over-frequency, i) Input surge, j) over
temperature of heatsink, k) loss of remote speed signal etc. The VFD
shall also have userfriendly programming software & it shall be capable
of at least two level parameter setting with password lock for critical
parameters,rogramming for I/Os, speed search function, copy
parameters (upload / download) to other identical unit, tuning to energy
saving mode (maximum efficiency), event / fault recording (last 5 faults
in non-volatile memory) & RS 485 communication port (MODBUS
RTU protocol) with required software., - 22 kW
SITC of fencing of Transformer yard at Water supply pumping station
suitable size require 624 sq ft including piller 40*40*3 connecting piller
79 pipe 25*25*3 and Gate size 5ft*6ft for yard entery with including civil 1.00 Job 255196.18
work and materials and one coat primar and final coat silver.etc.The job
carried out as par engineer in charge.
I / We agree to carry out the above work at ____________ % above the estimated rate ((In Words)
_________________________________________________) percentage above the Estimated Tender Rate.
I / We agree to carry out the above work at ____________ % below the estimated rate ((In Words)
_________________________________________________) percentage below the Estimated Tender Rate.
Estimated Amount Estimated Amount
Put to Tender Rs. 68,60,748.77/- Put to Tender Rs. 68,60,748.77/-
Add % Above Rs.______________ Deduct % Below Rs. ______________
Net Amount Rs.______________ Net Amount Rs. ______________
Net In Figure Rs. _____________ Net in Figure Rs. ______________
I / We have read the Condition mentioned in this tender and agree to abide by the same.
Note:- Estimated Cost put to tender is excluding GST and Including all other Taxes. GST will be paid additional as per
applicable rate prevailing from time to time and all other statutory liabilities are part of estimated cost and will be bound by
bidder. Prospective bidder may please by read carefully, app prevailing policy /Government Resolution (GT) of Govt. of
Gujarat (GoG)/competent authority, regarding GST and submit the price bid offer accordingly.
Sachin Notified Area
Signature of Contractor with Seal G.I.D.C.-SACHIN
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender Document.pdf
SCHEDULE B.pdf
B1 Agreement.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .