| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.4 L+₹2.5 L (9.38%)Rejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹32.2 L+₹5.3 L (19.8%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹33.3 L+₹6.5 L (24.0%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹35.6 L+₹8.7 L (32.4%)Rejected-Finance 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹30.0 L
EMD Value
₹59,980
Closing Date
22 Jan 2024, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar
Maintenance of Prepaid Meters and AMR System including Repair/ Replacement and Maintenance of Water Supply Works alongwith connected works at certain locations under GE (I) Navy Jamnagar
2024_MES_635218_1
8714/VAL/E8
Open Tender
Miscellaneous Works
Item Rate
336 days
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹59,980
Yes
9 Feb 2024
1 Jan 2024
24 Jan 2024
1 Jan 2024
22 Jan 2024
17 Jan 2024
Amount
Note :- Servicing, repair & maintenance of Automatic Meter Reading System (AMRS) and Lifts shall be carried out through authorized service agency of Original Equipment Manufacturer (i.e M/s RDS/ Hitch Nick Automation and KONE respectively). The contractor shall submit documentary proof/evidence in this regard before execution of Work.
Providing one year license charges for cloud based online Automatic Meter Reading and Billing Software suitable for 2000 meters, data storage charges for storing meter details, billing data 615 meter for a period of 11 months to cloud server and Programming for modem of Electro magnetic water flow meter including network setting and time setting for sending daily reports/ data for both water meters including the following features :- (a) Remote Monitoring and Reporting, (b) Billing, (c) e-mail and alerts utility, (d) Meter reading shall be updated every 10 minutes (user settable), (e) Time stamp of last reading received. (with offline meter notification center), (f) Automatic bills generation at the end of period of category based consumers as directed by Engineer-in-Charge, (g) User settable billing format as directed by Engineer-in-Charge, (h) Facilitty to change/ add meter calculations of billing amount of bill generation of users at every end of specific period of category, (j) Monthly bills to be mailed to user if email ID of user exists in server, (k) Admin access can view and edit details of consumers, (l) Admin access can view periodic bills of any category of consumers and print them on demand, (m) Admin access can set consumer exit date of living quarter for generating manual bill of specific time period of consumer, (n) Supports common meter of building and calculate the amount of common meter energy charges will be distributed to all active consumers of that building.
Recharges of new SIM cards GPRS enabled and Electronic magnetic water flow meter recharge for 115 SIM Cards on monthly basis.
S&F in repairs external antenna for GPRS modem gain 9db for transmitting and receiving data to and from server. Make: RDS, Hitch Nick Automation
S&F in repairs Switched-mode power supply/ Voltage Converter for voltage supply to PIC circuit : 230V AC to 12V DC current.Make: RDS, Hitch Nick Automation
S&F in repairs PIC Microcontroller based single/ multiple meter monitoring module: Operating Voltage: 230V AC, Circuit Voltage 12V DC. Make: RDS, Hitch Nick Automation
S&F in repairs Pickup Phototransistor used for sensing the blinking of LED on digital electrical meter. Make: RDS, Hitch Nick Automation
S&F in repairs Communication modem between module and control centre (server): MQTT or HTTP over GPRS protocol. Make: RDS, Hitch Nick Automation
S&F in repairs cable 4 core PVC insulated unsheathed multistranded copper conductor of size 1.50sqmm (ISI marked) including suitable casing caping / PVC conduit etc. complete all as directed.
S&F in repairs master panel box including LED indication on display from front side of panel all as directed by Engr in charge.Make: RDS, Hitch Nick Automation
Cloud charges/transaction charges for prepaid energy meter for maintaining system smoothly working with making liason to dealer/authorise rep of HPL.
Annual Maintenance Charges for 40 Nos prepaid meter for 11 Calendar months which includes following : (a) Annual 9 Nos. of one day site visit will be counting in 11 Months AMC free of cost for any fault; Malfunction of meter will be check at site. Prepaid meter data programming related work will be done. (b) Energy meter software related update will be given as and when require. (c) Prepaid meter repair or rectification, Energy meter should be sent to HPL Factory for component repairing, but component charges will be extra as per HPL Electric & Power Ltd. (d) Site visit timing- 48 hours as when require for any fault in prepaid meter complete all as directed. (e) AMC to be carried out through authorised rep/dealer of OEM i.e. HPL complete all as directed.
Taking down old unserviceable single phase electronic energy meter/ Three Phase electronic energy meters of any make complete. Note: Old meter will be property of department and should be deposited to MES store by contractor.
S&F single phase AC Electronic energy meter 2 wire with LCD display, Rating 10-60A ,240 V, 50 Hz complete all as directed. Make: HPL Electric & Power Ltd Cat No. SPPB1510000000OC00 or equivalent of MECO, SECURE, L&T
S&F three phase AC Electronic energy meter 4 wire with LCD display, Rating 10-60A ,3 x 240 V, 50 Hz complete all as directed. Make: HPL Electric & Power Ltd Cat No. TPPL1510000000OCN0 or equivalent of MECO, SECURE, L&T
S&F Single Phase Two wire AC Static Enegy (10-60A) Direct Current class 1.0 keypad based pre-payment electronic energy meter with Customer Interface Unit (CIU) and Soft Token Transfer Device (STTD) comprising of 01 No. single source pre-payment meter +1 No. CIU without cable +1 No. STTD + Meter to CIU 2 pair shielded cable (1.5 meter length) including making necessary electrical connections and testing on completion as per manufacturer instructions complete all as directed. Make: HPL Electric & power Ltd Cat No. PSPB1523111000OC01 or equivalent of MECO, SECURE, L&T
S&F Three Phase four wire AC static Energy (10-60A) Direct Current class 1.0 keypad based pre-payment electronic energy meter with Customer Interface Unit (CIU) and Soft Token Transfer Device (STTD) comprising of 01 No. single source pre-payment meter +1 No. CIU without cable +1 No. STTD + Meter to CIU 2 pair shielded cable (1.5 meter length) including making necessary electrical connections and testing on completion as per manufacturer instructions complete all as directed. Make: HPL Electric & power Ltd Cat No. PTPB1521130000OC01 of equivalent of MECO, SECURE, L&T Note for item No 15 & 16 :(i) After installation & testing of Static Energy Meter it is the responsibility of the contractor to install soft ware for creation of portal/ database as per manufacturers recommendations and further to traine MES Personnel until they are conversant to prepare Consumer Data base, tarif creations, setting of load limit, meter allotment and any other information required to carry out the work as per manufacturers literature. (ii) One time transcation charges to be paid by contractor in advance for each meter @ Rs 40/ Meter (iii) Quoted rate for the said item is deemed to be inclusive of the above, no extra whatsoever shall be entertained at later date.
S&F in repairs Meter to CIU Cable RJ11 both End, 2 pair Shielded Cable.
M&L for carried out water testing report as per IS-10500:2012 with all required water container by Govt Authorised laboratory and submit Bactriological & Chemical report for 02 Nos. Sample (i.e. RO Plant Water & Potable Water)
M&L for comprehensive maintenance and repairs of micro processor based controlled VVV frequency drive, electric driven Lift with ARD, Goods lift of capacity 1000 Kgs. installed at Dwarka Building serving ground plus 2 floors incl examining, adjusting, lubricating, greasing and replacement of u/s parts like hooter, fire switches, indication, emergency light, low voltage relay complete all as directed by Engineer-in-Charge. Note: (i) Comprehensive maintenance, repair and replacement of all spare parts and components fitted by KONE will be original parts or components fitted will be of equal quality and functionality as on when required shall be carried out only through authorised service agency of OEM under strict supervision of well experienced and qualified staff. (ii) The make of spares shall be shown as suitable for the existing system and shall be provided by authorized manufacturer's. (iii) The rates deemed to includes for all items which are not considered in schedule but the same is essential for smooth & efficient functioning of the lift costing less then Rs 400/- i.e. fuse, thumbles, connectors etc. (iv) The contractor shall keep all spares reqd for unserviceable spares parts replaced will be properties of the OEM and also the routine maintenance and attend the defects immediately. In case of major defects it shall be attended within 24 hrs failing which penal recovery @ 1000/- per day will be charged. The decision of GE will be final & binding in this regard.
Item No. 19 Contd/- (v) The total Nos of Visit for normal servicing in general basis are 11 Nos (Monthly basis) and also Breakdown service covered during normal working hours (vi) spares parts listed in item No.48 to 54 will be measured and paid under relevant items separately as ordered. (vii) Contractor will be liable for defective unserviceable provide below mentioned items Sl No. (a) to (w) as and when required for maintenence of Lift or in breakdown condition for smooth & efficient functioning of Lift as per OEM requirement . The rates of spares & fitting deemed to be included in the quoted rates. (a) Drive module, KDL16R 20A 400V (b) LCECCBe Assembly (c) PCB, LCECPU NC Board V3F18 (d) ENCODER, MX D37.3 L2=4500 (e) Land Operating Panel, LOP-CB Assembly (f) LCE PCB Assembly
Item No. 19 Contd/- (g) LCE CEB assembly (h) LCE COB Assembly (j) LCECIB,New LON Protocol. (k) Pit switch Sssembly, 1 NC 230VAC (l) UPS Device, 600VA 230V 1 PH (m) PCB,LOP230 Saftey Chain interface 1.2 (n) AMD D10 Motor assembly (o)AMD D10 Spare Module ( Parallel ) - G03 (p) AVD7S assembly (q)Transformer, Drive 1 230V, 50/60HZ (r) Switch Contact, Slack rope Device (s) Switch Door contact 230VAC 2A (t)Tension weight, swing Arm OL35 (u)TL Jones Curtain of Light (v) Toothed Belt, Drive1 W = 12mm (w)Pully, Toothed belt D38.8mm W = 19.8mm
Supply and Fix in repair ARD batteries 7 AH 12 Volts
S&F in repair MCCB 120 Amps 415 V, 50Hz with adjustable thermal and magnatic setting of breaking capacity 36 KA . Make Legrand or equivalent all as specified and directed
S&F in repair ELCB 4 Pole three phase, 40 Amps 415 V, 50Hz of breaking capacity 10 KA . Make Legrand or equivalent all as specified and directed
S&F in repair ELCB 2 Pole single phase, 25 Amps 230 V, 50Hz of breaking capacity 10 KA . Make Legrand or equivalent all as specified and directed
S&F in repair MCB TPN 63 Amps 415 V, 50Hz of breaking capacity 10 KA . Make Legrand or equivalent all as specified and directed
S&F in repair Car Blower Fan single phase supply 230 V ,50Hz all as specified and directed
S&F in repair Car LED Light single phase supply 230 V ,50Hz all as specified and directed
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
M&L for cement concrete 1:3:6 type C1, using 20mm graded crushed stone aggregate as in stand posts, cills, steps, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
M&L for preparation of all steel & iron surfaces of Header by scrubbing out existing paint with wire brush/ scrubber and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of zinc chromate primer including marking of all incoming & outgoing line with white synthetic enamel paint and nomenclature complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking up or down old rusted/ worn out GI tubing & connections of 100 mm bore fixed in any position and S&F new 100 mm bore galvanized steel water tubing medium grade (ISI Marked) with & including all necessary fittings (ISI Marked) such as bend, tee, elbow, etc laid in trenches/ floors or fixed on wall and ceiling in required length complete all as specified and as directed. Note : Excavation & earthwork shall be measured & paid for separately.
All as per serial item No. 32 here in above but 80 mm bore.
All as per serial item No. 32 here in above but 50 mm bore.
All as per serial item No. 32 here in above but 40 mm bore.
All as per serial item No. 32 here in above but 25 mm bore.
All as per serial item No. 32 here in above but 20 mm bore.
All as per serial item No. 32 here in above but 15 mm bore.
Dismantling and taking up or down old UPVC pipe of size 80mm bore and Supply, laying & jointing 80mm bore UPVC Pipes (Sch 80) with & including all necessary UPVC fittings (Sch 80) such as bend, tee, socket, elbow, etc, Solvent Weld Pipe (Lead Free), laid in trenches/floor or/and fixed to walls in required length and testing on completion, complete all as specified and as directed. Notes :- (i) Excavation & earthwork shall be measured & paid for separately. (ii) The quoted rates shall include for fittings and jointing materials.
All as per serial item No. 39 here in above but 50 mm bore.
All as per serial item No. 39 here in above but 40 mm bore.
All as per serial item No. 39 here in above but 25 mm bore.
All as per serial item No. 39 here in above but 20 mm bore.
All as per serial item No. 39 here in above but 15 mm bore.
S&F in repairs 50mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete all as specified & as directed.
S&F in repairs 40mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete all as specified & as directed.
S&F in repairs 25mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete all as specified & as directed.
S&F in repairs 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete all as specified & as directed.
S&F in repairs 15mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete all as specified & as directed.
S&F in repairs UPVC ball valve (Sch 80) of size 80 mm bore complete all as specified & as directed.
S&F in repairs UPVC ball valve (Sch 80) of size 50 mm bore complete all as specified & as directed.
S&F in repairs UPVC ball valve (Sch 80) of size 40 mm bore complete all as specified & as directed.
S&F in repairs UPVC ball valve (Sch 80) of size 25 mm bore complete all as specified & as directed.
S&F in repairs UPVC ball valve (Sch 80) of size 20 mm bore complete all as specified & as directed.
S&F in repairs UPVC ball valve (Sch 80) of size 15 mm bore complete all as specified & as directed.
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 150 mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 150 mm bore, complete all as specified & as directed.
All as per item No. 56 here-in-above, but 100 mm bore
All as per item No. 56 here-in-above, but 80 mm bore
Supply and fixing Non Return Valve (NRV) of size 150mm bore, cast iron body, as per IS 5312 (ISI marked), heavy duty, class ‘PN-1.6’, gun metal seat, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint complete all as specified and as directed including dismantling & taking out old unserviceable non return valve of 150mm bore.
All as per item No. 59 here-in-above, but 100 mm bore
S&F 100 mm bore butterfly valve cast iron body, class PN 1.6, ISI marked, single eccentric, double flanged short body type with all fittings, nuts, bolts and washers and necessary rubber gaskets etc., including taking down old butterfly valve compete all as specified and as directed.
Attending Bedi water supply complaints such as water leakage from UPVC/CI/DI/GI pipe line of 80mm to 150mm bore pipe in civil and defence areas and other various locations by excavating in any type of soil, check the nature of defects for leakages and rectification work to be carried out by replacing requisite materials, testing complete on completion of work & then returning, filling the soil including disposal of surplus soil if any as directed by Engineer-in-Charge. Notes : (i) UPVC/CI/DI/GI pipe of size 80 mm to 150 mm bore and necessary fittings required for rectification of work shall be measured and paid under relevant items. (ii) Excavation in any type of soil upto 6 Cum & its RFR & removal including dewatering required for complaint work shall deemed to be included in quoted rates of this item. Beyond 6 Cum excavation, these shall be measured & paid under respective items of earthwork in this Schedule. (iii) Necessary permission from civil authorities, local bodies and liaison with these authorities shall be the responsibility of the contractor and should be done prior to execution of work. (iv) Necessary barricade, diversion boards and necessary safety signs, etc as per standard procedure shall be adopted by the contractor wherever work is in progress without any extra cost. (v) Requisite T&P and transportation for tradesman to rectify the defects shall be contractor’s responsibility. (vi) The quoted rates shall include the cost of dewatering and work in liquid mud.
All as per serial item No. 62 here in above but for 15mm to 50mm bore.
M&L for construction of Valve pit chamber of size 1200x1200x1200mm internal dimension including necessary excavation & earth work in any type of soil, PCC 1:4:8 type D2 in foundation, brick work with old size fly ash bricks in CM 1:4, 15 mm thick plaster in CM 1:4 internally and externally flush pointed in same mortar as work proceeds, 75 mm thick PCC coping all round in PCC 1:2:4 type B1 (using 20 mm graded stone aggregate), flooring shall be 40 mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate laid over 75 mm thick hard core. Top cover shall be made out of MS sheet 3.00 mm thick fixed in angle iron frame made out of angle iron size 40x40x6 mm with two number of hinges on one side and locking arrangement at other side complete including painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed including dismantling of old existing unserviceable vale pit chamber. Note : Any minor modification where required at site shall be deemed to be included in the quoted rates. The decision of GE shall be final and binding regarding extent to which the change can be considered as minor.
All as per serial item No. 64 here-in-above, but of internal size 900x900x900 mm -do-
All as per serial item No. 64 here-in-above, but of internal size 600x600x600 mm -do-
M&L for top cover of valve pit chamber of size 1200 x 1200mm made with 3mm thick MS sheet with supporting MS angle iron frame made out of 40 x 6mm and painting with two coats of bitumen paint over a coat of red oxide primer and locking arrangement, fixed in repairs, complete all as specified and directed.
All as per serial item No. 67 here-in-above, but top cover size 900 x 900mm -do-
All as per serial item No. 67 here-in-above, but top cover size 600 x 600mm -do-
M&L for cutting of existing road for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed.
M&L for Distribution Chart of Water Supply System of size 120cm x 90cm made of 3mm thick PVC/ Acrylic sheet, chart prepared and painted with different colour code as directed by Engineer-in-Charge, with suitable aluminium framing, fixed on wall with appropriate screws, complete all as directed. Note : Letters/matter etc for Distribution Chart shall be given by the Engineer-in-Charge. The lettering font & style, layout of water supply lines, etc shall be as directed by Engineer-in-Charge.
M&L for Distribution Chart of Electric Supply System of size 150cm x 90cm made of 3mm thick PVC/ Acrylic sheet, chart prepared and painted with different colour code as directed by Engineer-in-Charge, with suitable aluminium framing, fixed on wall with appropriate screws, complete all as directed. Note : Letters/matter etc for Distribution Chart shall be given by the Engineer-in-Charge. The lettering font & style, layout of electric supply lines, etc shall be as directed by Engineer-in-Charge.
M&L for Glow sign board of size 3.00m x 1.20m x 0.15m, out door type, totally enclosed with locking arrangement, front side made of 5mm thick milky white / coloured acrylic sheet with letters/matter/logo/sign by overlay colour film (colour as approved by Engineer-in-Charge) pasted over sheet, all other box work made out of 22 gauge thick galvanized iron sheet and 40mm x 40mm x 5mm MS angle iron frame work, with & including suitable LED light fittings 1x10 watt - 4 Nos, prewired, with & including all standard accessories as per standard trade practice including making electric connections with suitable size multistranded copper conductor cable, including two coats of synthetic enamel painting of approved tint over a coat of zinc chrome primer after preparation of steel surfaces of MS frame work, fixed on Padestal/wall/Gate placed over parapet/chajja etc or other location by grouting/placing appropriately as directed by Engineer-in-Charge, complete all as specified & as directed. Note : Letters/matter/logo/sign etc for sign board shall be given by the Engineer-in-Charge as per location of sign board. The lettering font & style, lightning work, etc shall be as directed by Engineer-in-Charge.
M/s Balaji Enterprise
Hirachand Sunderji and co
BHAVNA IMPERIAL ENTERPRISE
Rameshwar Enterprise
M/s. Vimal Enterprise
JAYESH TRADING CORPORATION
suvidhiconstruction
M/S Badri Electicals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .