Loading…
Loading…
Tender Value
₹6.5 Cr
EMD Value
₹6.5 L
Closing Date
10 Jun 2026, 11:00 am4d left
Construction of New ICMAI Bhawan for Baroda Chapter at Vadodara, Gujarat.
SBG/GUJARAT/ICMAI/NIT/85/2026
SBG/GUJARAT/ICMAI/NIT/85/2026
Open Tender-Domestic
Civil Works General
Vadodara, Gujarat
₹11,800
₹6.5 L
26 May 2026
26 May 2026
10 Jun 2026
10 Jun 2026
ABSTRACT OF COST
S. No. DESCRIPTION
1 EARTH WORK 823393.00 0.00
2 CONCRETE WORK 994212.00 0.00
3 REINFORCED CEMENT CONCRETE WORK 19220424.60 0.00
5 MARBLE & GRANITE WORK 2767050.20 0.00
6 WOOD AND PVC WORK 1383568.30 0.00
7 STEEL WORK 543715.00 0.00
12 SANITARY INSTALLATIONS 398685.08 1142603.80
13 WATER SUPPLY 379533.84 0.00
15 ALUMINIUM WORK 1822944.30 566550.00
16 WATER PROOFING 522782.50 0.00
17 STRUCTURAL GLAZING ALUMINIUM COMPOSITE PANEL 1847814.25 0.00
18 ELECTRICAL WORK 4633412.99 150622.00
19 SOLAR PV POWER GENERATION 1357000.00 0.00
24 IPABX/EPABX System 1380199.00 0.00
TOTAL OF DSR/ NDSR ITEMS ₹ 6,52,32,902.00
Digitally signed by SHUBHAM
NBCC (India) Limited
(A GOVERNMENT OF INDIA ENTERPRISE)
CONSTRUCTION OF NEW ICMAI BHAVAN FOR BARODA CHAPTER AT VADODARA, GUJARAT.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Earth work in excavation by mechancial means ( Hydraulic excavator)/ mannual
means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan)
including disposal of excavated earth, lead upto 50m and lift upto 1.5m disposed
earth to be levelled and neatly dressed.
Excavating trenches of required width for pipes, cables, etc including excavation for
sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting
2 2.10 out the excavated soil and then returning the soil as required, in layers not exceeding
20cm in depth including consolidating each deposited layer by ramming, watering,
etc and disposing of surplus excavated soil as directed, within a lead of 50m:
2.10.1 All kinds of soil
2.10.1.2 Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm dia. MTR 200.00 352.15 342.64 68528.00 0.00
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
3 2.25 foundations etc in layers not exceeding 20cm in depth , consolidating each deposited CUM 1500.00 196.00 190.71 286065.00 0.00
layer by ramming and watering, lead up to 50m and lift upto 1.5m.
Extra for every additional lift of 1.5m or part thereof in excavation/ banking
excavated or stscked materials.
TOTAL OF SUB HEAD: EARTH WORK 823393.00 0.00
Providing and laying in position cement concrete of specified grade excluding the
cost of centring and shuttering - all work upto plinth level.
4.1.8 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) CUM 150.00 6812.00 6628.08 994212.00 0.00
TOTAL OF SUB HEAD: CONCRETE WORK 994212.00 0.00
REINFORCED CEMENT CONCRETE WORK
6 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :-
5.9.1 Foundations, footings, bases of columns etc, for mass concrete. SQM 100.00 392.15 381.56 38156.00 0.00
Walls (any thickness) including attached pilasters, butteresses, plinth and string
5.9.3 Suspended floors roofs, landings, balconies & access platform. SQM 1420.00 927.25 902.21 1281138.20 0.00
5.9.5 Lintels, beams, plinth beams, girders, bressumers & cantilevers SQM 1000.00 736.40 716.52 716520.00 0.00
5.9.6 Columns, pillars, piers, abutments, posts and struts SQM 1000.00 961.30 935.34 935340.00 0.00
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
5.9.7 Stairs, (excluding landings) except spiral-staircase Sqm 150.00 764.95 744.30 111645.00 0.00
5.9.19 Weather shade, chajjas, corbels etc, including edges SQM 100.00 951.10 925.42 92542.00 0.00
Steel Reinforcement for R.C.C work including straightening, cutting, bending,
placing in position & binding all complete upto plinth level.
a) 5.22.6 Thermo-Mechanically Treated bars KG 32625.00 107.85 104.94 3423667.50 0.00
Steel reinforcement for R.C.C. work including straightening, cutting, bending,
placing in position and binding all complete above plinth level.
5.22 A.6 Thermo-Mechanically Treated bars. KG 60175.00 107.85 104.94 6314764.50 0.00
Providing and laying in position machine batched and machine mixed design mix M-
25 grade cement concrete for reinforced cement concrete work, using cement content
as per approved design mix, including pumping of concrete to site of laying but
excluding the cost of centering, shuttering, finishing and reinforcement, including
9 5.33 admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting
of concrete, improve workability without impairing strength and durability as per
direction of Engineer-in- harge.“(Note :- Cement contentconsidered in this item is @
330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable
5.33.1 All works upto plinth level
5.33.1.2 Concrete of M30 grade with minimum cement'content of 350 kg /cum cum 220.00 9655.70 9395.00 2066900.00 0.00
5.33.2 b) All works above plinth level upto floor V level
5.33.2.2 Concrete of M30 grade with minimum cement'content of 350 kg /cum cum 410.00 10011.35 9741.04 3993826.40 0.00
TOTAL OF SUB HEAD: REINFORCED CEMENT CONCRETE WORK 19220424.60 0.00
Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in foundation and plinth in:
6.1.2 Cement Mortar 1:6 (1 cement : 6 coarse sand). cum 100.00 7132.25 6939.68 693968.00 0.00
Brick work with common burnt clay F.P.S. (non modular) bricks of class
11 6.4 designation 7.5 in superstructure above plinth level up to floor V level in all
shapes and sizes in :
6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 100.00 9105.95 8860.09 886009.00 0.00
Providing and laying autoclaved aerated cement blocks masonry with 150mm
/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V
6.47 level with RCC band at sill level and lintel level with approved block laying polymer cum 250.00 8333.65 8108.64 2027160.00 0.00
modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The
payment of RCC band and reinforcement shall be made for seperately).
TOTAL OF SUB HEAD: BRICK WORK 3607137.00 0.00
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
MARBLE & GRANITE WORK
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and
prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias
and similar locations of required size, approved shade, colour and texture laid over 20
12 8.2 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white
cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc. complete at all
8.2.2 Granite of any colour and shade
Extra for providing opening of required size & shape for wash basin/ kitchen sink in
kitchen platform, vanity counter and similar location in marble/ Granite/ stone work,
including necessary holes for pillar taps etc. including moulding, rubbing and
polishing of cut edges etc. complete.
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre
height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1
cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white
cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To
be secured to the backing and the sides by means of cramps and pins which shall be
paid for separately) :
(a) 8.14.1 Red sand stone - exposed face fine dressed with rough backing.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Designing, fabricating, testing, installing and fixing in position Curtain Wall with
Aluminium Composite Panel Cladding, with open grooves for linear as well as
curvilinear portions of the building , for all heights and all levels etc. including:
(a) Structural analysis & design and preparation of shop drawings for pressure
equalisation or rain screen principle as required, proper drainage of water to make it
watertight including checking of all the structural and functional design. (b) (c)
Providing, fabricating and supplying and fixing panels of aluminium composite panel
cladding in pan shape in metalic colour of approved shades made out of 4mm thick
aluminium composite panel material consisting of 3mm thick FR grade mineral core
sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium
composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF /
Lumiflon based fluoropolymer resin coating of approved colour and shade on face #
1 and polymer (Service)coating on face # 2 as specified using stainless steel
screws,nuts,bolts,washers, cleats, weather silicone sealant, backer rods etc. The
fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with
serrations and serrated washers to arrest the wind load movement, fasteners, SS 316
Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-
metallic contacts all complete required to perform as per specification and drawing
The item includes cost of all material & labour component, the cost of all mock ups at
site, cost of all samples of the individual components for testing in an approved
laboratory, field tests on the assembled working curtain wall with aluminium
composite panel cladding, cleaning and protection of the curtain wall with
aluminium composite panel cladding till the handing over of the building for
occupation. Base frame work for ACP cladding is payable under the relevant
aluminium item.s The Contractor shall provide curtain wall with aluminium
composite panel cladding, having all the performance characteristics all complete , as
per the Architectural drawings, as per item description, as specified, as per the
approved shop drawings and as directed by the Engineer-in-Charge. However, for the
purpose of payment, only the actual area on the external face of the curtain wall with
Aluminum Composite Panel Cladding (including width of groove) shall be measured
TOTAL OF SUB HEAD: MARBLE & GRANITE WORK 2767050.20 0.00
WOOD AND PVC WORK
Providing wood work in frames of doors, windows, clerestorey windows and another
frames, wrought framed and fixed in position with hold fast lugs or with dash
fasterners of requires dia & length ( hold fast lugs or dash fasterner shall be paid for
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I)
decorative type, core of block board construction with frame of 1st class hard wood
and well matched teak 3 ply veneering with vertical grains or cross bands and face
veneers on both faces of shutters.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S.
Piano hinges IS:3818 marked with necessary screws.
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I)
non-decorative type, core of block board construction with frame of 1st class hard
wood and well matched commercial 3 plyveneering with vertical grains or cross
bands and face veneers on both faces of shutters :
9.21.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 118.00 2172.10 2113.45 249387.10 0.00
Extra for Providing and fixing flush doors with decorative veneering instead of non
decorative ISI marked flush door shutters conforming to IS: 2202 (Part I)
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth
on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with
21 9.46 two chromium plated brass brackets fixed with C.P.
brass screws and wooden plugs, etc., wherever necessary complete :
Providing and fixing aluminium die cast body tubular type universal hydraulic
door closer (having brand logo with ISI, IS : 3564, embossed on the body, door
weight upto 35 kg and door width upto 700 mm), with necessary accessories and
screws etc. complete.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic
23 9.96 coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required
colour or shade with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not
24 9.97 less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or
shade with necessary screws etc. complete :
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less
25 9.100 than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade
with necessary screws etc. complete :
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Providing and fixing aluminium hanging floor door stopper ISI marked
26 9.101 anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or
dyed to required colour and shade with necessary screws etc.complete.
9.101.2 Twin rubber stopper each 10.00 72.35 70.40 704.00 0.00
27 9.114 Providing and fixing magnetic catcher of approved quality in cupboard /
9.114.2 ward robe shutters, including fixing with necessary screws etc. complete. each 15.00 39.70 38.63 579.45 0.00
Providing and fixing factory made uPVC door frame made of uPVC extruded
sections having an overall dimension as below (tolerance ±1mm), with wall thickness
2.0 mm (± 0.2mm), corners of the door frame to be Jointed with galvanized brackets
28 9.117 and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of
the frames reinforced by galvanized M.S.tube of size 19 X 19mm and 1mm (± 0.1
mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as
per manufacturers specification and direction of Engineer-in-charge
9.117.1 Extruded section profile size 48x40 mm. mtr 100.00 270.20 262.90 26290.00 0.00
29 9.118 Providing and fixing to existing door frames.
24 mm thick factory made PVC door shutters made of styles and rails of a uPVC
hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt
edging on both sides.The styles and rails mitred and joint at the corners by means of
M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm
and stainless steel screws. The styles of the shutter reinforced by inserting galvanised
M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made
up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm)
wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U'
cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not
less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall
thickness. The panels filled vertically and tie bar at two places by inserting
horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete
as per manufacturer's specification and direction of Engineer-in-charge. (For W.C.
and bathroom door shutter).
Providing & Fixing decorative high pressure laminated sheet of plain /wood
grain in gloss / matt / suede finish with high density protectivesurface layer and
reverse side of adhesive bonding quality conforming toIS : 2046 Type S including
cost of adhesive of approved quality.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including
a coat of approved primer on one face, and fixed on wooden /steel frame work,
complete as per direction of Engineer-in charge (Frame work shall be paid for
9.140.1 12mm thick commercial ply conforming to IS : 1328 BWR type Sqmt. 100.00 1224.65 1191.58 119158.00 0.00
Providing and fixing stainless steel fancy handle of approved make fixed with SS
screws etc. complete as per direction of Engineer-in- charge.
Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges
(hydraulic type) of approved make/brand to cupboard shutters with full threaded steel
screws including making necessary recess in board and finished etc. complete as per
direction of Engineer- in-charge.
Providing and fixing stainless steel soft closing heavy type telescopic drawer channels
34 9.172 of approved make 500 mm long with screws etc. complete as per directions of one set 25.00 885.10 861.20 21530.00 0.00
Engineer- in-charge.
TOTAL OF SUB HEAD: WOOD AND PVC WORK 1383568.30 0.00
Steel work welded in built up sections/ framed work including cutting, hoisting,
35 10.25 fixing in position and applying a priming coat of approved steel primer using
structural steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. kg 1000.00 172.60 167.94 167940.00 0.00
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,
channels, plates etc., including welding, grinding, buffing, polishing and making
curvature (wherever required) and fitting the same with necessary stainless steel nuts
and bolts complete, i/c fixing the railing with necessary accessories & stainless steel
dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the
side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (
for payment purpose only weight of stainless steel members shall be considered
excluding fixing accessories such as nuts, bolts, fasteners etc.).
TOTAL OF SUB HEAD: STEEL WORK 543715.00 0.00
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)
37 11.3 finished with a floating coat of neat cement including cement slurry, but excluding
the cost of nosing of steps etc. complete.
11.3.1 40mm thick with 20mm nominal size stone aggregate. SQM 50.00 614.20 597.62 29881.00 0.00
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with
grey cement slurry mixed with pigment to match the shade of the slab, including
rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12
mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with
grey cement slurry mixed with pigment to match the shade of the slabs, including
rubbing and polishing complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS:15622, of approved brand & manufacturer, in all colours and shade,
laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey
40 11.41A cement slurry @3.3 kg/sqm including grouting the joints with white cement and
matching pigments etc. The tiles must be cut with the zero chipping diamond cutter
only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of
required thickness, leveling system and rubber mallet for placing the tiles gently and
11.41A.2 Glazed vitrified floor tiles polished finish of size
Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer
41 11.43 modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3 Sqmt. 1500.00 753.25 732.91 1099365.00 0.00
Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1
cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps
with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in
42 11.44 shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 Sqm 250.00 954.15 928.39 232097.50 0.00
micron & length upto 6 mm , mixing fibre @ 125 grams per 50 kg of cement in
cement mortar, including providing and mixing water proofing material in mortar @
1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge.
Providing and laying Vitrified tiles in different sizes (thickness to be
specified by manufacturer), with water absorption less than 0.08 % and
conforming to I.S. 15622, of approved make, in all colours & shade, in
skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3
coarse sand), including grouting the joint with white cement & matching pigments
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy
grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener
and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per
direction of Engineer-in-charge.
Deduct for not grouting the joints with white cement and matching pigment in the
items of fixing of vitrified tiles.
TOTAL OF SUB HEAD: FLOORING 4637184.55 0.00
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal
46 12.22 size) over P.V.C. Sheet 1mx1mx400 micron, finished with 12mm cement each 10.00 298.25 290.20 2902.00 0.00
plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges
and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A including jointing with seal ring
conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed
Providing and fixing on wall face unplasticised - PVC moulded
fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS :
13592 Type A including jointing with seal ring conforming to IS :5382 leaving
10 mm gap for thermal expansion.
12.42.6 Shoe (Plain)
Providing and fixing unplasticised -PVC pipe clips of approved design to
unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs,
49 12.43 screwed with M.S. screws of required length including cutting brick work and
fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any
pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia.
G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses
etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating
minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi
and hot cured. They shall be of uniform pigmentation and thickness without air
pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or
translucent, clear or pigmented, textured or smooth as specified
Providing and fixing false ceiling at all heights including providing and fixing
of frame work made of special sections, power pressed from M.S. sheets and
galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS :
277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges
of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling
with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of
cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts &
bolts of required size and other end of angle hanger fixed with intermediate G.I.
channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to
which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered
flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be
fixed in a direction perpendicular to G.I. intermediate channel with connecting clips
51 12.45 made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing
perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm
long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450
mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing
of gypsum board to ceiling section and perimeter channel with the help of dry wall
screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush
finish of tapered and square edges of the board with recommended jointing
compound , jointing tapes , finishing with jointing compound in 3 layers covering
upto 150 mm on both sides of joint and two coats of primer suitable for board, all as
per manufacturer's specification and also including the cost of making openings
for light fittings, grills, diffusers, cutouts made with frame of perimeter channels
suitably fixed, all complete as per drawings, specification and direction of the
Engineer in Charge but excluding the cost of painting with :
12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board Sqmt. 100.00 1529.1 1487.81 148781.00 0.00
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight
calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true
horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel
sections (galvanising @ 120 grams per sqm including both side) consisting of main
‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made
from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross
“T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced
between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and
secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick
(Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from
grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall
angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum)
sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry
52 12.53 wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum Sqmt. 1300.00 2158.15 2099.88 2729844.00 0.00
silicate ceiling tiles of approved texture in the grid, including, cutting/ making
opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.,
wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted
cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash
fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x
0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24
mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as
per specifications, drawings and as directed by Engineer-in-Charge.
Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No
deduction shall be made for exposed frames/opening (cut outs) having area less than
0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum),
light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity
resistance and also having thermal conductivity <0.043 w/mK.
Providing and fixing thermal insulation with Resin bonded rock wool conforming to
53 12.61 IS: 8183, density 48 kg/m3, 50 mm thick, wrapped in 200 G virgin Polythene bags sqmt. 120.00 316.05 307.52 36902.40 0.00
placed over existing false ceilng and held in position by criss-crossing Gl wire.
Providing and fixing thermal insulation with Resin Bonded rock wool conforming to
IS: 8183, having density 48 kg/m3,50 mm thick,wrapped in 200 G Virgin Polythene
Bags fixed to wall with screw, rawel plug & washers and held and in position by criss
cossing GI wire etc. complete as per directions of Engineerin-Charge.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Providing and fixing of glass wool with GI stud frame of GI 0.45 mm thick 50 mm
wide on wall with screws, applying glasswool / rockwool 50mm thickness 48 kg
55 NS density on the GI frame. 9 mm thick acoustic wall panel having upto 0.9 NRC value Sq.Ft. 1600.00 500.00 0.00 800000.00
which is 60% recyvled pet product with ASTM E-84 class, EN 13501 S1, Do as per
the drawing and instructed by Engineer in charge.
Providing and fixing of 16mm MDF J side laminated perforated with framing as per
directed by engineer in charge.
Providing and fixing in wall lining medium density fibre board IS:14587:1998
57 NS marked, Pre-laminated one side decorative lamination and other side balancing
lamination, with necessary fixing arrangement and screws etc. complete.
Supply and fixing Aluminium Profile PRO Channel all complete as per the drawing
and instructed by Engineer in charge.
TOTAL OF SUB HEAD: ROOFING 3124237.15 1265539.00
59 13.1 12 mm cement plaster of mix
18 mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1
60 13.12 cement : 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 sqmt 1300.00 537.45 522.94 679822.00 0.00
fine sand) finished with rough sponge
61 13.16 6 mm cement plaster of mix :
Providing and applying white cement based putty of average thickness 1 mm, of
62 13.80 approved brand and manufacturer, over the plastered wall surface to prepare the Sqmt. 3000.00 156.05 151.84 455520.00 0.00
surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content
63 13.41 less than 50 gram/litre, of approved manufacturer and of required shade and colour all
complete to achieve even shade and colour :
New work (two or more coats) over and including water thinnable priming coat
with cement primer having VOC content less than 50 gram/litre
64 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming
coat of exterior primer applied @ 0.90 litre/10 sqm)
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Painting with synthetic enamel paint of approved brand and manufacture of required
colour to give an even shade :
Two or more coats on new work over an under coat of suitable shade with ordinary
paint of approved brand and manufacture
TOTAL OF SUB HEAD: FINISHING 3348322.00 0.00
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi
tracks/ runways, using cement content as per design mix, using coarse sand and
graded stone aggregate of 40 mm nominal size in appropriate proportions as per
approved & specified design criteria, providing dowel bars with sleeve/ tie bars
wherever required, laying at site, spreading and compacting mechanically by using
needle and surface vibrators, levelling to required slope/ camber, finishing with
66 16.43 required texture, including steel form work with sturdy M.S. channel sections, curing,
making provision for contraction/ expansion, construction & longitudinal joints ( 10
mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with
approved joint filler and sealants, complete all as per direction of Engineer-in-charge
(Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).
Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement
used as per design mix is payable/ recoverable separately.
Cement concrete manufactured in automatic batching plant (RMC plant) i/c
transportation to site in transit mixer
Providing and laying 60mm thick faciory made cement concrete interlocking paver
block of M -30 grade made by block making machine with strong vibratory
67 16.68 compaction, of approved size, design & shape, laid in required colour and sqmt 1500.00 972.00 945.76 1418640.00 0.00
pattern over and including 50mm thick compacted bed of coarse sand, filling
the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade
cement concrete in position to the required line, level and curvature, jointed
with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with
or without grooves (thickness of joints except at sharp curve shall not to more than
5mm), including making drainage opening wherever required complete etc. as per
direction of Engineer-in-charge (length of finished kerb edging shall be
measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-
TOTAL OF SUB HEAD:ROAD WORK 3235346.90 0.00
SANITARY INSTALLATIONS
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983
69 17.10 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and
brackets, cutting and making good the walls wherever required :
17.10.1 Kitchen sink with drain board
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved
70 17.31 quality) complete with 6 mm thick hard board ground fixed to wooden cleats with each 10.00 1607.95 1564.54 15645.40 0.00
C.P. brass screws and washers complete.
71 17.35 Providing and fixing soil, waste and vent pipes :
17.35.2 75 mm diameter :
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast
iron/cast iron (spun) pipe embedded in and including cement concrete blocks
72 17.37 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate
20mm nominal size) including cost of cutting holes and making good the walls
Providing and fixing bend of required degree with access door, insertion rubber
washer 3mm thick, bolts and nuts complete.
74 17.39 Providing and fixing plain bend of required degree.
Providing and fixing single equal plain junction of required degree with access
door, insertion rubber washer 3 mm thick, bolts and nuts complete.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
76 17.44 Providing and fixing single equal plain junction of required degree
77 17.56 Providing and fixing terminal guard:
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron
pipes and fittings of diameter:
Providing and fixing trap of self cleansing design with screwed down or
79 17.60 hinged grating with or without vent arm complete, including cost of cutting and
making good the walls and floors :
17.60.2 100 mm inlet and 75 mm outlet
Painting sand cast iron/centrifugally cast (spun) iron soil, waste vent pipes and
80 17.65 fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of
primer (of approved quality) for new works:
81 NS Supply and Installation JAQUAR 35721P AKP TOWEL RING SQUARE PCS 15.00 2820.93 0.00 42313.95
82 NS Supply and Installation JAQUAR 35731P AKP SOAP DISH HOLDER PCS 15.00 1410.47 0.00 21157.05
83 NS Supply and Installation JAQUAR 35735P AKP SOAP DISPENSER WITH GLASS PCS 15.00 2485.11 0.00 37276.65
Supply and Installation JAQUAR ALD CHR 565 HEALTH FAUCET WITH EASY
85 NS Supply and Installation JAQUAR 15053PM OPP ANGULAR STOP COCK WITH PCS 20.00 1578.38 0.00 31567.60
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
86 NS Supply and Installation JAQUAR 5935 FIS WHITE TABLE TOP BASIN PCS 10.00 9448.64 0.00 94486.40
Supply and Installation JAQUAR 81953UF VGS WHT RIMLESS WALL HUNG
88 NS Supply and Installation JAQUAR 769L300X190 ALD BOTTOL TRAP PCS 10.00 2619.44 0.00 26194.40
89 NS Supply and Installation JAQUAR 13257 URINAL PCS 13.00 10880.73 0.00 141449.49
Supply and Installation JAQUAR PRS-077 URINAL VALVE AUTO CLOSING
Supply and Installation JAQUAR 107KN LONG BODY BIB COCK WITH
Supply and Installation JAQUAR 35021PM PILAR COCK WITH 190MM
93 NS Supply and Installation METROPOLL PCS 20.00 4724.32 0.00 94486.40
TOTAL OF SUB HEAD: SANITARY INSTALLATIONS 398685.08 1142603.80
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes,having
thermal stability for hot & cold water supply,including all CPVC plain &brass
threded fittings,including fixing the pipes the pipe with clamps at 1.00 m
spacing.This includes jointing of pipes & fittings with one step CPVC Solvent
cement and the cost of cutting chases and making good the same including testing of
joints complete as per direction of Engineer in charge.
Concealed work, including cutting chases and making good the walls etc.,
18.8.2 20 mm nominal outer dia Pipes metre 51.00 537.60 523.08 26677.08 0.00
18.8.3 25 mm nominal outer dia Pipes metre 80.00 627.25 610.31 48824.80 0.00
Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes,having
thermal stability for hot & cold water supply,including all CPVC plain &brass
95 18.9 threded fittings.This includes jointing of pipes & fittings with one step CPVC Solvent
cement ,trenching ,refilling & testing of joint complete as per direction of Engineer
18.9.3 25 mm nominal outer dia Pipes metre 30.00 355.40 345.80 10374.00 0.00
18.9.4 32 mm nominal outer dia Pipes metre 100.00 438.60 426.76 42676.00 0.00
18.9.5 40 mm nominal outer dia Pipes metre 100.00 563.05 547.85 54785.00 0.00
18.9.7 62.50 mm nominal inner dia Pipes metre 50.00 1674.40 1629.19 81459.50 0.00
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Providing and fixing gun metal gate valve with C.I. wheel of approved quality
(screwed end) :
Providing and fixing ball valve (brass) of approved quality, High or low pressure,
with plastic floats complete :
Providing and placing on terrace (at all floor levels) polyethylene water storage tank
ISI: 12701 marked indicating the BIS License No. with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow pipes but
without fittings and the base support for tank.
TOTAL OF SUB HEAD: WATER SUPPLY 379533.84 0.00
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of
99 19.1 cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of
joints etc. complete :
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
100 19.2 stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as
per standard design:
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I.
grating brick masonry chamber with water tight C.I. cover with frame of 300 x300
mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not
less than 2.70 kg as per standard design :
19.4.2 150 x 100 mm size P type.
19.4.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 5.00 2734.20 2660.38 13301.90 0.00
Providing and laying non-pressure NP2 class ( light duty) R.C.C.pipes with collars
102 19.6 jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine
sand) including testing of joints etc. complete.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand
) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse
sand : 8 graded stone aggregate 40mm nominal size), inside plastering 12mm thick
with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat
cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) finished with a floating coat of neat
cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty)
19.7.1 455x610 mm internal dimensions, total weight of cover and frame to be not less than
38 kg (weight of cover 23 kg and weight of frame 15 kg) :
19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 10.00 12770.55 12425.75 124257.50 0.00
104 19.8 Extra for depth for manholes
19.8.1 Size 90x80 cm
19.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 mtr 3.00 8825.40 8587.11 25761.33 0.00
Making connection of drain or sewer line with existing manhole including
breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement
plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished
with a floating coat of neat cement and making necessary channels for the drain etc.
TOTAL OF SUB HEAD: DRAINAGE 598319.80 0.00
Providing and fixing aluminium work for doors, windows, ventilators and
partitions with extruded built up standard tubular sections/ appropriate Z
sections and other sections of approved make conforming to IS: 733 and IS:
1285, fixing with dash fasteners of required dia and size, including necessary filling
up the gaps at junctions, i.e. at top, bottom and sides with required EPDM
rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight,
mitred and jointed mechanically wherever required including cleat angle,
Aluminium snap beading for glazing /paneling, C.P. brass/ stainless steel
screws, all complete as per architectural drawings and the directions of Engineer-
in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) KG 1000.00 530.90 516.57 516570.00 0.00
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
For shutters of doors, windows & ventilators including providing and fixing
hinges/ pivots and making provision for fixing of fittings wherever required
including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid
for separately)
21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) KG 600.00 634.45 617.32 370392.00 0.00
Providing and fixing glazing in aluminium door, window, ventilator shutters
and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of engineer-in-charge . (Cost of
aluminium snap beading shall be paid in basic item):
21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) Sqm 80.00 1685.40 1639.89 131191.20 0.00
Providing and fixing double action hydraulic floor spring of approved brand and
manufacture conforming to IS : 6315, having brand logo embossed on the body /
plate with double spring mechanism and door weight upto 125 KG, for doors,
108 21.4 including cost of cutting floors, embedding in floors as required and making good the
same matching to the existing floor finishing and cover plates with brass pivot and
single piece M.S. sheet outer box with slide plate etc. complete as per the direction of
Engineer-in-charge.
21.4.1 With stainless steel cover plate minimum 1.25 mm thickness EACH 10.00 2823.85 2747.61 27476.10 0.00
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved
brand and manufacture, including providing and fixing top & bottom pivot & double
109 21.18 acting hydraulic floor spring type fixing arrangement and making necessary holes Sqm 150.00 5325.90 5182.10 777315.00 0.00
etc. for fixing required door fittings, all complete as per direction of Engineer-in-
charge (Door handle, lock and stopper etc.to be paid separately).
Supply and fitting of Zebra Blinds as per Technical Specification provided by
Engineering Incharge.
TOTAL OF SUB HEAD: ALUMINIUM WORK 1822944.30 566550.00
Providing and laying water proofing treatment to vertical and horizontal surfaces of
depressed portions of W.C. kitchen and the like consisting of:
Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing
i). compound conforming to IS 2645 in recommended proportions including rounding
off junction of vertical and horizontal surface.
IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water
ii). proofing compound in recommended proportion including rounding off junction of
vertical and horizontal surface.
IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should
be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Providing and laying integral cement based water proofing treatment
112 22.7 including preparation of surface as required for treatment of roofs,balconies, terraces
etc consisting of following operations:
a) Applying aslurry coat of neat cement using 2.75 kg/sqm of cement admixed
with water proofing compound conforming to IS. 2645 and approved by
Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height
including cleaning the surface before treatment.
b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm
size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with
water proofing compound conforming to IS : 2645 and approved by Engineer-in-
charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand )
admixed with water proofing compound conforming to IS : 2645 and approved
by Engineer-in-charge to required slope and treating similarly the adjoining walls
upto 300 mm height including rounding of junctions of walls and slabs
c) After two days of proper curing applying a second coat of cement slurry using 2.75
kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse
sand) admixed with water proofing compound conforming to IS : 2645 and approved
by Engineer-in-charge including laying glass fibre cloth of approved quality in top
layer of plaster and finally finishing the surface witht rowel with neat cement
slurry and making pattern of 300x300 mm square 3 mm deep.
e) The whole terrace so finished shall be flooded with water for a minimum period of
two weeks for curing and for final test. All aboveoperations to be done in order and as
directed and specified by the Engineerin-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65
TOTAL OF SUB HEAD: WATER PROOFING 522782.50 0.00
STRUCTURAL GLAZING ALUMINIUM COMPOSITE PANEL
Designing, fabricating, testing, protection, installing and fixing in position semi (grid)
113 25.2 unitized system of structural glazing (with open joints) for linear as well as
curvilinear portions of the building for all heights and all levels, including
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
(a) Structural analysis & design and preparation of shop drawings for the specified
design loads conforming to IS 875 part III (the system must passed the proof test at
1.5 times design windpressure without any failure), including functional design of the
aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats,
sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc.,
structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke
seals, microwave cured EPDM gaskets for water tightness, pressure equalisation &
drainage and protection against fire hazard including:
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of
6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3
Dimentional movement for achieving perfect verticality and fixing structural glazing
system rigidly to the RCC/ masonry/structural steel framework of building structure
using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic
contacts with nuts and washers etc. of stainless steel grade 316, of the required
capacity and in required numbers.
(c) Providing and filling, two part pump filled, structural silicone sealant and one part
weather silicone sealant compatible with the structural silicone sealant of required
bite size in a clean and controlled factory / work shop environment, including double
sided spacer tape, setting blocks and backer rod, all of approved grade, brand and
manufacture, as per the approved sealant design, within and all around the perimeter
for holding glass.
(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick
and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap
between the building structure and all its interfaces with curtain glazing to make it
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
(e) Making provision for drainage of moisture/ water that enters the curtain glazing
system to make it watertight, by incorporating principles of pressure equalization,
providing suitable gutter profiles at bottom (if required), making necessary holes of
required sizes and of required numbers etc. complete.
This item includes cost of all inputs of designing, labour for fabricating and
installation of aluminium grid, installation of glazed units, T&P, scaffolding and
other incidental charges including wastages etc., enabling temporary structures and
services, cranes or cradles etc. as described above and as specified. The item includes
the cost of getting all the structural and functional design including shop drawings
checked by a structural designer, dully approved by Engineer-in-charge. The item
also includes the cost of all mock ups at site, cost of allsamples of the individual
components for testing in an approved
laboratory, field tests on the assembled working structural glazing as specified,
cleaning and protection till the handing over of the building for occupation. In the
end, the Contractor shall provide a water tight structural glazing having all the
performance characteristics etc. all complete as required, as per the Architectural
drawings, as per item description, as specified, as per the approved shop drawings
and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded
aluminium section capping for fixing in the grooves of the curtain glazing and vermin
proof stainless steel wire mesh shall be paid for separately under relevant items under
this sub- head. However, for the purpose of
payment, only the actual area of structural glazing (including width of grooves) on the
external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing
system if area of structural glazing exceeds 2500 Sqm from the certified laboratories
accreditated by NABL(National Accreditation Board for
Testing and Calibration Laboratories), Department of Science & Technologies, India.
Cost of testing is payable separately.
The NIT approving authority will decide the necessity of testing on the basis of cost
of the work, cost of the test and importance of the work. Performance Testing of
Structural glazing system Tests to be conducted in the NABL accredited lab or any
other accreditation body which operates in accordance with ISO/ IEC 17011 and
accredits labs as per ISO/IEC 17025
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to
+300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200
2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing
method for a range up to 2000 ml.
3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing
method for a range upto 2000 ml
4. Structural Performance Deflection and deformation by static air pressure test (1.5
times design wind pressure without any failure) as per ASTME-330-10 testing
method for a range upto 50 mm
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for
Qualitative test, Tests to be conducted on site.
6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto
Providing, assembling and supplying vision glass panels (IGUs) comprising of
hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of
size and shape as required and specified, comprising of an outer heat strengthened
float glass 6mm thick, of approved colour and shade with reflective soft coating on
surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass
6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary
seal (structural silicone sealant) etc. all complete for the required performances, as per
the Architectural drawings, as per the approved shop drawings, as specified and as
directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/
workshop of the glass processor.
(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item
No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels
(excluding the areas of the grooves and weather silicone sealant) provided and fixed
in position, shall be measured in sqm.(i) Coloured tinted float glass 6mm thick
substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat
Strengthened clear Glass of approved make having properties as visible Light
transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light
reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to
3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by
technical sanctioning authority as per the site requirement.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Extra for openable side / top hung vision glass panels (IGUs) including providing and
supplying at site all accessories and hardwares for the openable panels as specified
and of the approved make such as heavy duty stainless steel friction hinges, min 4 -
115 25.4 point cremone locking sets with stainless steel plates, handles, buffers etc. including sqm 25.00 3671.50 3572.37 89309.25 0.00
necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per
the Architectural drawings, as per the approved shop drawings, as specified and as
directed by the Engineer- in-Charge.
TOTAL OF STRUCTURAL GLAZING ALUMINIUM COMPOSITE PANEL 1847814.25 0.00
ELECTRICAL WORK
WIRING : WIRING IN PVC CONDUIT
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed
116 1.10 medium class PVC conduit, with modular switch, modular plate, suitable GI box and
earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor
single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper
conductor single core cable in surface/ recessed medium class PVC conduit along
with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable
for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of
FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed
medium class PVC conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated
119 1.18 annealed copper conductor, unarmored telephone cable in the existing surface/
recessed steel/ PVC conduit as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper
120 1.19 conductor PE insulated, shielded with fine tinned copper braid and protected with Meter 500.00 54.00 27000.00 0.00
PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Supplying and fixing of following sizes of medium class PVC conduit along with
121 1.21 accessories in surface/recess including cutting the wall and making good the same in
case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as required.
1.24.6 Telephone socket outlet Each 24.00 168.00 4032.00 0.00
1.24.7 TV antenna socket outlet Each 14.00 168.00 2352.00 0.00
Supplying and fixing two module stepped type electronic fan regulator on the existing
123 1.25 modular plate switch box including connections but excluding modular plate etc. as Each 70.00 402.00 28140.00 0.00
Supplying and fixing modular blanking plate on the existing modular plate & switch
box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet
and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on
126 1.32 surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular Each 30.00 659.00 19770.00 0.00
socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden
block including connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact
fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc.
129 1.41 directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC Each 301.00 259.00 77959.00 0.00
insulated, copper conductor, single core cable and earthing etc. as required.
Installation, Testing and Commissioning of ceiling fan, including wiring the down
rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated,
copper conductor, single core cable, including providing and fixing phenolic
laminated sheet cover on the fan box etc. as required.
131 1.49 Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. Each 406.00 72.00 29232.00 0.00
Installation, Testing and Commissioning of exhaust fan in the existing opening,
132 1.50 including making good the damage, connection, testing, commissioning etc. as
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell
point ( without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated
133 1.55 copper conductor single core cable in surface/ recessed PVC conduit, and earthing the
point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable
etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on
surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket
outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs
to be used in non residential buildings).
Supplying & fixing suitable size GI box with modular plate and cover in front on
135 1.57 surface or in recess including providing and fixing 25 A modular socket outlet and 25 Each 18.00 807.00 14526.00 0.00
A modular SP MCB, "C" curve including connections, painting etc. as required.
MCCB, MCB & DB'S
Providing and fixing following capacity TP&N disconnector fuse switch unit inside
136 2.1 the existing panel board with ISI marked HRC fuses including drilling holes in
cubicle panel, making connections, etc. as required.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Providing and fixing following rating and breaking capacity and pole MCCB with
thermomagnetic release and terminal spreaders in existing cubicle panel board
including drilling holes in cubicle panel, making connections, Ics=100% Icu and
Operational Voltage 690V etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet
steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator).
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature
139 2.10 circuit breaker suitable for inductive load of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete
etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the
existing MCB DB complete with connections, testing and commissioning etc. as
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A
143 2.16 240 V "C" curve DP MCB complete with connections, testing and commissioning Each 12.00 1258.00 15096.00 0.00
etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild
144 2.21 steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with Each 2.00 315.00 630.00 0.00
inscription in single red colour on front side as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple
145 2.24 pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess,
complete with testing and commissioning etc.as required.
2.24.3 For 8 way, Double door TPN MCB DB Each 4.00 1448.00 5792.00 0.00
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
RISING MAINS & BUS TRUNKING
Supplying Installation, Testing and Commissioning of on wall, testing and
commissioning of following capacity rising mains made of 1.6mm thick IP 42 sheet
steel enclosure duly painted with powder coating, wall straps, fully PVC insulated 4
Nos aluminium bus bars having current density of 130 A/ sq.cm at nominal current
146 3.1 rating in convenient sections and suitable for 415 V, 3 phase, 4 wire, 50 Hz, A.C.
supply with extension joints, fire proof barriers, expansion joints, thrust pads
including jointing and earthing with 2 runs of galvanised iron strips etc. as required.
(Rising mains confirming to IS 8623, TEC 439).
Supplying Installation, Testing and Commissioning of following capacity TPN tap
off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating
on existing rising mains complete with TPN disconnector FSU and HRC fuses,
connections, earthing etc. as required.
Hot Dipped Galvanized Iron Cable Tray
Supplying and installing following size of perforated Hot Dipped Galvanised Iron
cable tray (Galvanisation thickness not less than 50 microns) with perforation not
148 4.6 more than 17.5%, in convenient sections, joined with connectors, suspended from the
ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts &
nuts, fastner etc as required.
4.6.1 100 mm width X 50 mm depth X 1.6 mm thickness Meter 320.00 754.00 241280.00 0.00
Supplying and installing following size of perforated Hot Dipped Galvanised Iron
cable tray "bends" (galvanisation not less than 50 microns) with perforation not more
149 4.7 than 17.5%, in convenient sections, joined with connectors, suspended from the
ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts &
nuts, fastner etc as required.
4.7.1 100 mm width X 50 mm depth X 1.6 mm thickness Each 32.00 1252.00 40064.00 0.00
Supplying and installing following size of perforated Hot Dipped Galvanised Iron
cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more
150 4.8 than 17.5%, in convenient sections, joined with connectors, suspended from the
ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts &
nuts, fastner etc as required.
4.8.1 100 mm width X 50 mm depth X 1.6 mm thickness Each 26.00 1427.00 37102.00 0.00
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Supplying and installing following size of perforated Hot Dipped Galvanised Iron
cable tray "Cross member" (galvanisation not less than 50 microns) with perforation
151 4.9 not more than 17.5%, in convenient sections, joined with connectors, suspended from
the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI
bolts & nuts, fastner etc as required.
4.9.1 100 mm width X 50 mm depth X 1.6 mm thickness Each 5.00 1427.00 7135.00 0.00
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including
accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as
strip earth electrode, including connection/ terminating with nut, bolt, spring, washer
etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut
bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip
earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer
etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt
& spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing
156 5.18 along with existing surface/ recessed conduit/ submain wiring/ cable as required. Meter 200.00 50.00 10000.00 0.00
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop
157 5.19 earthing along with existing surface/ recessed conduit/ submain wiring/ cable as Meter 100.00 139.00 13900.00 0.00
LIGHTNING CONDUCTOR
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long,
158 6.1 G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate Each 1.00 609.00 609.00 0.00
including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for
lightning conductor complete as required.(For horizontal run)
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for
lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm
161 6.10 long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as Each 4.00 140.00 560.00 0.00
LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt) Supplying,
Installation, Testing & Commissioning of LED Recessed/surface Down lighter
(Round /square/Rectangular) SMD type of following body material with PMMA and
prismatic diffuser and construction as per IS : 10322 with driver as per the
requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,
frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection
of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI
>80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %),
life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning
Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation
IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin),
SDCM(Standard Deviation Color Matching) <3, Maximum power consumption
should not more than the specified rating and Fixture shall be of relevant BIS
standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on
housing. complete in all respect i/c external connections with 1.5 sq mm
FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt
output. LM79 & LM80 Test report and all testing required for LED fixtures as per
BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-
Charge as per requirement. (Thermal management: heat sink of aluminium housing
such that LED junction temperature shall not rise above 90°C). Powder coated die
cast /Extruded aluminium Body including trim .
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) Supplying,
Installation, Testing & Commissioning of LED Recessed/surface Down lighter
(Round / square/ Rectangular) COB Type of following body material and
construction as per IS : 10322 with driver as per the requirement with Driver
efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating
temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open
circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare
Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver &
electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial
Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per
ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power
163 8.5 consumption should not more than the specified rating and Fixture shall be of
relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/
Screen printing on housing. OEM must have its own in house NABL lab setup for all
testing facilities for LED fixtures. "complete in all respect i/c external connections
with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and
earthing etc. as required with Minimum 5 year OEM warranty. System lumen
efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing
required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be
as approved by Engineer-in- Charge as per requirement. (Thermal management: heat
sink of aluminium housing such that LED junction temperature shall not rise above
90°C). Powder coated die cast /Extruded aluminium Body including trim with
Aluminium Reflector.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying,
installation, Testing & Commissioning of Panel light 2x2 ft., of following body
material and construction as per IS : 10322 with driver as per the requirement with
Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,
Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short
& Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified
Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,
Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial
Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per
ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power
164 8.8 consumption should not more than the specified rating and Fixture shall be of
relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/
Screen printing on housing. complete in all respect i/c external connections with 1.5
sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing
etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135
lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures
as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-
in- Charge as per requirement. (Thermal management: heat sink of aluminium
housing such that LED junction temperature shall not rise above 90°C).Powder
Coated CRCA Sheet Body (Thickness >
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation,
Testing & Commissioning of LED surface mounted Batten light of following body
material and construction as per IS : 10322 with driver (Replaceable) as per the
requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt,
frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection
of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI
>80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical
circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained
till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),
SDCM(Standard Deviation Color Matching) <3, Maximum power consumption
165 8.11 should not more than the specified rating and Fixture shall be of relevant BIS
standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on
housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR,
PVC insulated copper conductor single core cable and earthing etc. as required with
Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output .
LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall
be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per
requirement. (Thermal management: heat sink of aluminium housing such that LED
junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
8.17 LED Flood Light, powder coated pressure die cast aluminium (System lumen
efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood
Light, powder coated pressure die cast aluminium body with built in or separate
driver as per the requirement with Driver efficiency >85%, Input voltage: Input
voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C,
internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency
>85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under
voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam
angle 30 deg-120deg as per the application and the project requirement., suitable tilt
able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning
166 8.17 Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation
IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,
SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption
should not more than the specified rating and Fixture shall be of relevant BIS
standard complete in all respect i/c external connections with 1.5 sq.mm
FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt
output. LM79 & LM80 Test report and all testing required for LED fixtures as per
BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-
Charge as per requirement. (Thermal management: heat sink of aluminium housing
such that LED junction temperature shall not rise above 90°C).
Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing
and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor,
class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2
nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor
not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance
as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for
operation with regulator for speed control and all remaining accessories including
safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance
more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling
Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm
FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as
9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) Each 42.00 2695.00 113190.00 0.00
9.2.4 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) Each 28.00 2737.00 76636.00 0.00
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Supplying & erecting single phase approved make industrial exhaust fan suitable for
168 Non-Sch medium duty ring mounted low noise operation suitable for medium duty having Each 23.00 2034.00 0.00 46782.00
following dia size and maximum speed in RPM [A] 305 mm dia 900 RPM - Cat.II
MV CABLE LAYING
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1
KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
10.5.2 Above 35 sq. mm and upto 95 sq. mm Meter 35.00 72.00 2520.00 0.00
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1
170 10.6 KV grade of following size in the existing masonry open duct as required.
10.6.2 Above 35 sq. mm and upto 95 sq. mm Meter 15.00 58.00 870.00 0.00
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power
171 10.7 cable of 1.1 KV grade of following size on wall surface as required.
10.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Meter 15.00 64.00 960.00 0.00
10.7.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Meter 10.00 151.00 1510.00 0.00
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power
cable of 1.1 KV grade of following size on cable tray as required.
10.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Meter 15.00 53.00 795.00 0.00
10.8.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Meter 10.00 109.00 1090.00 0.00
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate
173 10.10 with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 Each 10.00 598.00 5980.00 0.00
cm long and fixing the same in ground as required.
MV CABLE JOINTING & END TERMINATION
Supplying and making straight through joint with cast resin compound including
174 11.3 ferrules and other jointing materials for following size of PVC insulated and PVC
sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Supplying and laying of following size DWC HDPE pipe ISI marked along with all
accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete
175 15.16 with fitting and cutting, jointing etc.direct in ground (75 cm below ground level)
including excavation and refilling the trench but excluding sand cushioning and
protective covering etc., complete as required.
Supplying, Installation, Testing and Commissioning of ISI Marked openwell
submersible pump set contain with stainless steel shaft and cast iron/SS body, the
pump shall be designed to prevent over loading and having dynamically balanced
rotating parts etc. the pump capable of delivering following capacities
176 20.16 discharge at suitable head and lowering the pumps in water bodies and suitable for EACH 2.00 49514.00 99028.00 0.00
operation on 415V(+- 10%), 3-phase AC supply including providing required no's of
heavy duty M.S clamps made of flat iron and suitable size top cover made of suitable
thick MS sheet including connection, interconnection , supports etc. as required.
suitable for 900LPM at 25 Mtrs Head etc. complete as required.
Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat
cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump
including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes
etc. complete as required.
Supply of following size of 1.1KV grade multicore aluminium conductor
178 Non - Sch XLPE insulated PVC sheathed armoured power cable as per IS: 7098 (Part-1) 1988
complete as required.
TOTAL OF ELECTRICAL WORK 4633412.99 150622.00
SOLAR PV POWER GENERATION
Solar Photovoltaic Power Plant Supplying Installation, Testing and Commissioning
of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards
BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and
CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline
silicon solar cells module, net metering facility, necessary control, protections,
earthing, cabling, mounting structure, junction boxes, power conditioning units, Real
time online web interfaced Data Monitoring System, Distribution panels, grid
connecting arrangement, conduits, pipes, cable trays and other accessories etc. as
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above,
manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1,
IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be
less than 23% at STC with temperature coefficient of Pmax better than -0.30% per
0C. PV modules used in solar power plants/ systems must be warranted for their
output peak watt capacity, which should not be less than 90% at the end of 10 years
a) and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative
humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV
module used in any solar power project must have Radio frequency identification tag
with information such as name of manufacturer, month and year of manufacturing,
country of origin (separately for Solar cell and module), I-V curve, Unique Serial No
and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC
Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V
AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with
a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total
harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50
0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and
data logger, MPPT, switching devices IGBT/MOSFETs and controller
Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation
including wake-up, synchronization & shutdown. The PCU shall be able to withstand
unbalanced load conforming to IEC standard with shutdown/standby mode. It must
be provided with grid islanding along with manual disconnect pole isolation switch
besides automatic disconnection. Minimum protections: Mains Under / Over Voltage,
Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at
output due to external source, Short-circuit, Lightening, Anti Islanding (for grid
synch. Mode) and other protections as per applicable standards. LCD/LED display of
minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3
phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC
energy produced and other parameters applicable standard. Communication interface
Module mounting structure: The roof top solar plant generation units shall be
installed by using supporting Aluminium/Galvanized MS structure (mass of zinc
coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter
above the terrace level / ground level. The mounting structure would be designed to
sustain wind load and seismic parameter of the site of installation. All the structure
shall be design as per applicable BIS code and the material shall also confirm the
applicable BIS Code. Structural material shall be corrosion resistant and
electrolytically compatible with the materials used in the module frame, its fasteners,
nuts and bolts. The suitable arrangements for maintenance and cleaning shall be
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Real time online web interfaced Data Monitoring System complete with accessories
for various parameters such as Solar Irradiance, temperature, AC Output Voltage and
d) current, Output Power, Power factor, DC Input Voltage and Current, Time Active,
Time disabled, Time Idle, Power produced and other parameters as per standard
Array junction box & Main junction box with IP 65 protection and termination
arrangement for incoming and outgoing cable along with glands, lugs and other
accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder
Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof
arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs)
(semiconductor diode with resistant applied voltage)/ surge arrestors and suitable
Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper
f) Lightning, surge voltage protection, earthing protection and grid islanding.
Cables: Connections & Interconnections by required size IR/UV protected XLPE
insulated copper conductor 1.1 kV grade armored power and control cables(ISI
Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays,
supports, lugs, thimble and other accessories etc. as required.
DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal
h) cladded, having copper bus bar, having required protection and control gears, kWp 25.00 54280.00 1357000.00 0.00
connection-interconnection, etc. as required.
TOTAL OF SOLAR PV POWER GENERATION 1357000.00 0.00
UNINTERRUPTED POWER SUPPLY (UPS)
180 26.2 Online UPS- Input supply: Three Phase, Output supply: Three Phase.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Supplying, installation, Testing & Commissioning of following capacity at full load
(Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to
95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for
the replacement or addition of battery modules without shutting down the entire
system) modular Power Supply (UPS) system with N+1 modules (N denotes total
number of modules required for rated capacity). The UPS shall include a Rectifier,
inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall
not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full
load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch
along with provision for manual bypass, suitable isolation transformer for additional
protection against neutral faults etc. UPS shall have inbuilt phase sequence
correction. The UPS systems offered are to be of the latest technology with Digital
Control Microprocessor based for reliable operation using Insulated Gate Bipolar
Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse
Width Modulation). The quality of design, manufacturing and inspection process
should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The
operating efficiency of the UPS systems shall be >96% while operating on battery
mode and delivering quality power to the 100% non-linear loads. Current total
harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required
LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme
power factor kit to be included to limit the input power factor (PF) to 0.99 and output
power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ),
however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor
loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz
+/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of
120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1
meter distance, protections: Input Under voltage over voltage, abnormal out voltage,
battery over charging, output over current, short circuit protection, battery deep
discharge protection, 10KV surge. UPS must comply with low voltage
electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and
26.2.5 60KVA (Each Power module shall be < 10 KVA) Each 1.00 913600.00 913600.00 0.00
TOTAL OF UNINTERRUPTED POWER SUPPLY (UPS) 913600.00 0.00
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Supplying, Installation, Testing & Commissioning of following capacity passenger
Machine room less (MRL) lift with regenerative drive as per CPWD General
Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC
2016 as amended upto date having provision for barrier free access as per
Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of
MoHUA, serving different floors in the lift shaft as per detailed specifications
enclosed and as under including all other equipment and accessories complete as
(i) Speed-1 MPS
(ii) Floors-5 (G+4)
(iii) Travel -17 Meters (approx.)
(iv) Stops & opening- 5 stops and 5 openings
(v) Controller: A.C. variable voltage & variable frequency
(vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as
vii) Operation: Microprocessor based single automatic push button/simplex selective
collective/duplex collective selective with/without attendant
(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system
(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline
Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw)
and LED fitting.
(x) The car flooring should be smooth and antiskid as approved by engineer-in-
(xi) Type of doors
(a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof
(Moon Rock/Honeycomb/ Hairline Finish).
(b) Landing doors: stainless steel scratch proof .
(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed
adjacent to control panel in the lift car.
(xiii)Voice announcement system in the car to announce the position of the elevator
TOTAL OF LIFT 1684225.72 0.00
DIESEL GENERATOR SET
Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating
set as per CPCB IV + or better norms along with having Prime Power Rating of KVA
as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50
Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with
182 29.1 fuel, load for test and other necessary arrangements Complete as per CPWD
specifications, should have QR code which should contain drawing, test report OEM
manual,Geo- Tag of
manufacturing location, rating plate as per relevant IS Code etc. and consisting of the
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder,
dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable
for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of
taking 10% over loading for one hour after 12 hours of continuous operation. The
engine will be with Electronic governor, Dry type Air filter with service indicator,
first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other
consumables complete with all the required accessories, the Electronic governor shall
be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV +
or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as
per CPWD specifications.
Engine mounted Instrument Panel fitted with and having digital dis Plate for
(i) Start-stop switch with key
(ii) Water temperature indication
(iii) Lubrication oil pressure indication
(iv) Lubrication oil temperature indication
(v) Battery charging indication and Voltage indication
(vi) RPM indication
(vii) Over speed indication
(viii) Low lubricantion Oil trip indication
(ix) Engine Running Hours indication
Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500
RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH &
at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof
(SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor,
capable of taking 10% over loading for one hour after 12 hours of continuous
operation, self cooled,self-excited and self-regulated through AVR conforming to
IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H
Base Frame & Foundation: Both the engine and alternator shall be mounted on
suitable base frame made of MS channel with necessary reinforcement which shall be
installed on suitable cement concrete foundation and vibration isolation arrangement
as per recommendations of manufacturer.
FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD
Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard
(E) accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’
pipes of suitable dia. Complete with valves, level indications & accessories as
required as per specifications.
Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and
catalytic convertor.
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Starting System: 12V/24V DC starting system comprising of starter motors: voltage
regulator and arrangement for initial excitation complete with suitable numbers of
batteries (180 AH capacity lead acid SMF type) as required as per specifications. The
battery shall be housed inside the acoustic enclosure of DG Set.
Acoustic and weather proof enclosure with arrangement for fresh air intake for
cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere
and the temperature rise inside the enclosure, noise level outside enclosure. The
(H) acoustic enclosure should be suitable for cable connection/connection through bus-
trunking. Such arrangements on acoustic enclosure should be water proof & dust-
proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or
better norms etc. and as per CPWD specifications.
AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel
including auto by-pass, suitable for KVA as below for silent type DG set complete
with relays, timers, set of CTs for metering & protection and energy analyser to
indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt
Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for
overload, short circuit, restricted earth fault, under frequency, power (aluminium) and
control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT
Panel and DG Set including connection interconnection etc. as required, all complete
and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for
BMS integration including suitable software, the panel shall be of DG Set OEM make
etc. as per approved by Engineering in charge and including the following:
1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated
draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C &
E/F and shunt trip.
2. Auto/Manual/Test/Off selector switch
3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2
Nos. reverse power relay and 2 Nos. under voltage relay).
4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I
5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase &
Total), Frequency, KWH, PF.
6. LED Indicating lamps for load on mains and load on set
7. Fuse/ MCB for instruments
8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter,
selector switch for trickle, off and boost and current adjustment.
9. Main supply failure monitor
10. Supply failure timer
11. Restoration timer
12. Control unit with three impulse automatic engine start/stop and failure to start
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
TOTAL OF DIESEL GENERATOR SET 1194906.00 0.00
Supplying, Installation, Testing & Commissioning of Modular type Variable
Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for
cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll
Compressor(s),minimum two compressors (with individual separate PCB) for above
14HP modules, microprocessor based Controller, top discharge type condensing
unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable
foundation etc. complete as required. To have better efficiency condenser fan shall be
capable to operate at different speed with respect to load.The unit shall deliver the
rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications
and work even at 50°C ambient temperature without tripping. The system shall be
183 31.3 able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to
work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The
unit shall be filled with first charge of the refrigerant and ready for use as required.
The condenser should be coated with a hydrophilic film to prevent water
accumulation on the surface of the heat exchanger, enhance water dispersion, and
reduce the risk of degradation, thereby improving overall performance and durability.
The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per
Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and
complete as per CPWD specification, connections, inter connections etc. as required.
(For capacity <40 kWr ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70
ISEER 7.6 for Super ECSBC Building)
Supplying, Installation, Testing and Commissioning of following minimum capacity
4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable
media pre-filter, fan section with low noise fan/dynamically balanced blower,
multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer
cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote
control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply,
complete, as required. The Indoor units must shut down upon receiving a singal from
the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per
room requirement in auto mode. The cooling capacity of indoor unit will be at air
inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Supplying, Installation, Testing and Commissioning of following minimum capacity
Single way wall/corner VRV/VRF Cassette Type Indoor ceiling mounted unit
equipped with synthetic washable media pre-filter, fan section with low noise
fan/dynamically balanced blower, multispeed motor, coil section with DX Copper
coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports,
185 31.6 vibration Isolation, Corded remote control etc., suitable for operation on single phase
230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut
down upon receiving a singal from the BMS System/Fire Singnals. The system shall
be capable to adjust air flow as per room requirement automatically. The cooling
capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB
temperature. (Make will be same as of Outdoor)
Supplying, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall
be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs
31.13.2 Outdoor Multi Joint Each 10.00 8098.00 80980.00 0.00
COPPER REFRIGERANT PIPING
Supplying, Installation, testing and commissioning including vaccumiazation and
Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant
piping for VRV/VRF system, complete with fittings, with suitable adjustable ring
187 13.14 type hanger supports, jointing/brazing including accessories, insulated with XPLE
Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular
sleeves sections of 19 mm thick insulation as given below for Suction and Liquid
lines, all accessories as per specifications etc. as required :
13.14.1 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Meter 150.00 256.00 38400.00 0.00
13.14.2 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Meter 100.00 346.00 34600.00 0.00
13.14.3 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Meter 100.00 487.00 48700.00 0.00
13.14.4 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Meter 30.00 739.00 22170.00 0.00
13.14.5 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Meter 40.00 615.00 24600.00 0.00
Total of VRV/VRF 1577602.00 0.00
IPABX/EPABX System
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Supplying, installation, testing and Commissioning of IP at its core with IP switching
technology and 100% non blocking communication system with 04 Port Voicemail,
04 Port FXS, 04 Port FXO, 1 PRI Trunk lines (30 Channels) Circuit with CLIP
Facility, min 100 IP users License with provision for further additions, 100 analog
users, 01 Number IP based Operator Console, 45 Party Conference, Speed Dial,
Music on Hold, Internal/ External ring difference, Call Barring, Call Pickup. The
system should be redundant which offer 100% duplication of power supply and CPU
card and to match the hybrid IP-PBX as per technical specification including
supporting accessories etc complete as required. The system should have valid TEC
GR approval from DoT.
Supplying, Installation, Testing & Commissioning of Type 1 IP Phone having 2 VoIP
189 38.3 account, 120 x40 DOT matrix screen with backlight, Full HD duplex speaker phone, Each 5.00 11698.00 58490.00 0.00
IPV6, Gigabit Etherent, PoE etc. complete as required.
Supplying, Installation, Testing & Commissioning of Analog phones having standard
190 38.4 feautres like 16 digit LCD display, 2 way speaker, caller ID and number storage Each 15.00 1544.00 23160.00 0.00
facility etc. complete as required.
Supplying and drawing 20 Pair 0.5 mm dia FRLS PVC insulated annealed copper
191 38.5 conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC Meter 150.00 344.00 51600.00 0.00
Conduit etc. complete as required.
Total of IPABX/EPABX System 1380199.00 0.00
192 Non - Sch LT PANEL
Supplying, instalation, Testing and Commissioning of Fllor Mounted /Wall Mounted
LT Panel, made out of 2mm thick CRCA sheet steel, compartmentalised with hinged
lockable doors, dust and vermin proof, powder coated,Complete with Busbars,
MCCBs/MCBs,cable alley, inter connection with suitable size copper conductor
cable/solid copper strip, having switchgears and accessories, mountings and internal
wiring, earth terminals, numbering, Labels etc. complete in all respect, complete as
per specification with following in coming and Outgoings, suitable for operation on
415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
1 no. of 125 Amp FP MCCB of 26KA breaking capacity.
Metering for incoming:
Digital Multifunction meter with RS-485 communication port for measurement of
PF, V, A & Hz , equivalent to EM6459,with CT as required.
Phase indicating lamps RYB with 2 Amps SP MCB back up.
ON / OFF indicating lamps
Rate ( Rs.) Rate ( Rs.) Amount ( Rs.)
Sr. No. DESCRIPTION OF ITEMS UNIT QUANTITY DSR 2025 DSR 2023 After Correction NDSR DSR NDSR
Electrolytic high conductivity AL three phase and neutral busbars rated at 160 Amps,
insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
Current density of Bus Bar to be 1.3 sq.mm / amp.
Outgoing (All MCB/MCCB shall be suitable for motor duty):
4 Nos. 63 amp 4P MCB of 10 KA breaking capacity
2 Nos. 40 amp 4P MCB of 10 KA breaking capacity
PANEL as described above shall be complete with all interconnections, risers,
internal wiring, labels, terminal blocks etc. complete as required.
Total of Light & Power PANEL 0.00 111971.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NITICMAI85.pdf
Tender Document
GCCICMAI85.pdf
Tender Document
BOQICMAI85.pdf
Tender Document
APPROVEDMAKESICMAI85.pdf
Tender Document
IntegrityPactICMAI85.pdf
Tender Document
SCCICMAI85.pdf
Tender Document
TechnicalcircularsICMAI85.pdf
Tender Document
DrawingICMAI85.pdf
Tender Document
Download all tender documents and submit your bid