Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹12.0 L+₹7,475 (0.63%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹12.2 L+₹33,650 (2.83%)Accepted-Finance | L3 | Accepted-Finance L3 | |
| 4 | L4₹12.4 L+₹51,455 (4.33%)Accepted-Finance | L4 | Accepted-Finance L4 | |
| 5 | L5₹12.9 L+₹99,611 (8.37%)Accepted-Finance | L5 | Accepted-Finance L5 |
Tender Value
₹18.7 L
EMD Value
₹37,500
Closing Date
19 Jan 2024, 4:00 pmClosed
Executive Engineer,Elect. Division Vijaypur
Office of the Executive Engineer, Electric Division Vijaypur, JPDCL Jammu
Supply ,Erection, Testing an Commissioning of 400 KVA Distribution Substation along with creation of tapping Point for Load enhancement in Favour of M/s Century Polymers Pvt. Ltd. Bandurakh within the jurisdiction of Electric Division Vijaypur, JPDCL
2024_PDD_242818_1
EDV 53 of 2023-2024 Dated 12-01-2024
Open Tender
Electrical Works
Turn-key
45 days
Samba
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Executive Engineer, Electric Division Vijaypur
₹37,500
10 Feb 2024
12 Jan 2024
20 Jan 2024
13 Jan 2024
19 Jan 2024
13 Jan 2024
13 Jan 2024 - 19 Jan 2024
Amount
Creation, Testing & Commissioning of 400KVA Distribution Transformer Sub Station
Supply,Transortation , Installation testing & commissioning of 11/0.433 -400 KVA ;50 Hz , Copper Wound Distribution Transformer of latest Energy Efficiency Level-2 (New) ,ISII80 PART-I as per latest up to date amendment with externally fitted MCCB with cable box & 4x4 mtrs suitable cable of ratings
Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST410- SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of GI Channel Angle/Flat of sizes including clamps for LA Set/GO Set /Horn Gap
Supply, Installation, Testing & Commissioning of 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 KV Horn Gap Fuse Set 3 Phase 200 A .
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing & Fixing of 240 mm²(2 Ckt) Single-phase Cable ,1.1 KV Grade ,PVC Insulated Stranded Conductor FRLS Type 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Providing of Earthing of substation --Excavation of earth pit of dia. 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GIStrip for neutral earthing of size 25 mm x 3 mm for connection of transformer body ,G.O Set &lightening arrestor as per IS 2629/85, GI nuts &bolts ,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of Cement Bottoming 1:2:4 mix as per REC Standards 0.45 cum/Pole Complete job
Painting of ST Poles with Red Oxide Paint and Al Paint (2 Coat each)
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Galvanized Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm),nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia. GI stranded wire complete
Supply, Installation, Testing & Commissioning of 3 Phase ,4 Wire Trivector Meter with CT
Constuction of Tramsformer Pad/Cement platform for 400 KVA transformer as per REC Standard.
Providing and fixing of P G Clamps
ERECTION OF11 KV TAP POINT ON 9 MTR ST POLES USING ACSR WEASELCONDUCTOR (1 No)
Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST410-SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of GI Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply ,Installation, Testing & Commissioning of 11KV GO AB Switch ,3-Phase ,3-Pole ,400 Amp
Supply, Laying & Stringing of ACSR Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Supply Installation, Testing & Commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Supply Installation, Testing & Commissioning of 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip
Providing of cement Bottoming 1:2:4 mix as per REC Standards 0.45 cum/Pole complete Job
Painting of ST Poles with Red Oxide Paint and Al. Paint (2 Coat Each)
JASMEET SINGH
Sandeep Kumar
SONI TECHNICAL SOLUTION
M/S VINAYAK ENGINEERS
M/S R. V ENTERPRISES
Sharma Enterprises
MAHA SHAKTI ELECTRICAL WORKS
M/S COMBINE GROUP OF ENGINEERS
VEENA CONSTRUCTION CO.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .