Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹40.1 LAccepted-AOC 21 549 FANCY LANE WEST FORT THRISSUR THRISSUR KERALA 680004 | THRISSUR | KERALA | 680004 | 1 | Accepted-AOC lowest | |
| 2 | 2₹41.0 L+₹88,117.50 (2.20%)Rejected-AOC 1ST FLOOR VARKKISONS BUILDING ANGAMALY ANGAMALY ERNAKULAM KERALA 683572 | ERNAKULAM | KERALA | 683572 | 2 | Rejected-AOC second |
Tender Value
₹42.4 L
EMD Value
₹50,000
Closing Date
23 Jan 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer PWD Electronics Division Thrissur
Deposit Installation of Real Time Rain and stream Gauges within Periyar and Chalakkudy Basins Establishment of Flood Forecasting and Early warning system for Periyar and Chalakkudy
2023_PWD_607229_2
PWD/BLDG/TR/1876/2023_7_1_1/1
Open Tender
Miscellaneous Works
Item Rate
90 days
Thrissur
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,760
₹50,000
2 Sept 2024
10 Jan 2024
25 Jan 2024
10 Jan 2024
23 Jan 2024
10 Jan 2024
Amount
Installation of Real time Rain and Stream gauges at Idukki District
OD243112/2022-2023:Supply, installation, configuration, testing and commissioning of Data logger with minimum connectivity of 2 sensors having following features :- Inputs ports Analogue (1) 4 to 20 mA, SDI 12 (1), Digital (1) bidirectional and Pulse(1). Output ports, USB (1), RS 232(1), Telemetry Communication ports for GSM (2). Resolution 16 bit or better with plus or minus 1 with a transmission interval of 1 sec up-to 24 hours. Memmory 1 GB (min) Flash type. Internal Display,with provision to show each sensor data, battery voltage etc with internal battery for system clock (lithium iron type) with a storage capacity 2 years (minimum). With inbuilt input key pad, GPS clock synchronization, with corrosion resistant material in NEMA 4 enclosure, ambient temperature -20 oC- +60 oC, altitude up-to 5000 meter, with complete set of tool kit and user manual in English, Warranty 3 year onsite. Approved make: SEBA, OTT, Virtual, Trackertech, Cellcomm.
OD243110/2022-2023:Supply,installation, calibration,configuration,testing and commissioning of Radar type water level sensor having local display with following specifications:- Type :-Microwave non contact type, range 20 meter. Resolution 3mm or better, Resolution 0.02% Full Scale, beam angle less than 16o, Power Supply 12VDC, interfaces SDI 12/RS 485/4-20 mA Heart Protocol, with corrosion resistant material in NEMA 4 enclosure, ambient temperature -20 oC- +60 oC, altitude up to 2500 meter, with complete set of tool kit and user manual in English, Warranty 3 year onsite. Approved Make: Seba, Vega
OD243111/2022-2023:Supply,installation, calibration , configuration ,testing and commissioning of Rain Gauge with stand and floor/mast mounting accessories with following specification:- Tipping Bucket type with read switch with a capacity of 250 mm/hour rain or better, resolution 0.5mm or better,with minmum accuracy of 2%, interfaces SDI 12/RS 485/4-20 mA Heart Protocol, with corrossion resistant material in NEMA 4 enclosure, ambiant temperature -20 oC- +60 oC, altitute upto 5000 meter, with complete set of tool kit and user manual in English, Warrenty 3 year onsite. Approved Make Seba, OTT, Virtual, Cellcomm.
OD243171/2022-2023:Supply,testing installation and commissioning of SMF batteries with 12 Volts 42 AH or above capacity with all necessary Connectors, cables and hardware mounting kit Approved Make Amaron Quanta, Exide Prosafe.
OD243197/2022-2023:Supply, Installation, Testing and Commissioning of BIS Certified Poly crystalline solar panels 80/100W as per IS/IEC standards, with Grade A solar cells with PID resistant technology. Open-Circuit voltage (Voc): 22 Volt, optimum operating current (Imp): 4.4 Amps or above , short-circuit current (Isc): 4.8 Amps or above . Modulus efficiency: 15.20% or above Warranty: 3 years on product and 25 years performance warranty
OD245366/2022-2023: Making of Fence, Gate and Foundations for ARG. The size of the fence 5 meter long X 5 meter wide X 2 meter height.The fencing must be made over a cement concrete enclosure which is 300 mm above ground level filled with rock aggregates of size 36 mm by a thickness of atleast 10 cm . Fencing angle size 40 mm x 40 mm x 6 mm and pre-coated with red-oxide. The total length of the fencing angle 2.8 meters i.e. (2.0m above ground level + 0.8 m below ground level). Two MS angles must be used diagonally at each of the four corner angles of the site. The angles can be attached (with welding or the other appropriate means) from the middle of the existing corner angle to the ground. The depth of the support will remain the same as of main angle. The dimensions of the fencing angle foundation should be 450 mm x 450 mm (length X width) and at a depth of 800 mm. Distance between each fencing angle 2.5 meter. Dimensions of GI Chain-link: 3 inches x 3 inches and of Gauge: 10 (3 mm diameter) GI chain-link mesh fixed properly on the fencing angles. A angle to be fixed on the upper part of the fencing . The chain-link fencing should be fastened with the help of screws fitted on the fencing angles. Gate Dimensions: 1 meter X 2 meter (Width x Height) with locking facility by MS Angle whose dimensions should be minimum 40 mm x 40 mm x 6 mm. locking facility with Rust proof Lock with3 keys Gate and MS Angle must be l painted with silver colour. Gate should have proper support of MS angles with additional support of crossed MS angles. Rain Gauge foundation. Rain gauge foundation must be of dimensions 450 mm x 450 mm (length x width) and 800mm deep. The rain gauge may be located so that it is at a minimum distance of 2 m away from obstructions on all four sides. The raised platform should be 230 mm above the ground level. In the case of flood prone areas the base plate on which the rain gauge is mounted should be placed 1.0 m above ground level. Sensor Supports and Brackets: - Aluminum or stainless steel - Sensor mounting supports and other accessories as required Proportions for concrete foundations Concrete pillar foundations for the mast fencing angle should be made in the volumetric mixing proportions as follows: Concrete foundation : 1 (Cement) : 2 (Sand) : 4 (Metal) Fine plastering : 1 (Cement) : 4 (Sand). Concrete Pillar must be cemented to achieve smooth finish above the ground level After 8 hours, these foundations should be cured with water at least 3 times a day for four days. The work includes the landscaping of fence area, removal of vegitations etc as required. The fencing angles, chain-link fencing and gate should be properly painted every year.All concrete foundations shall be painted using white cement paint every year, and the area should be cleared every year from any debries, vegitation etc.
OD245458/2022-2023:Supply and Installation of 4 meter long 150 mm diameter GI class B type pole with and offset of 60 cm from the height 1.5 meter above ground level/ without offset as required, mounted on the side of bridge or on a foundation as required. Painted with primer and two coat of white paint. The top of the pole should be covered with semi circular iron covering with at least 3 mm thickness protruding upwards without any dents to avoid any sort of ingress of water. The Pole should be provided with necessary provision for fixing data logger box, solar panel and Radar sensor. The pole top should be provided with 30 cm copper lightning arrester rod on a separate arm.
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
5.16:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
OD258749/2022-2023:Supply and Installation of Pole mount outdoor box with following specification:- size 600 mm x 400 mm x 300 mm (HxWxD) IP rating IP 66/67/68. Colour Grey Door Lock Type Single Lock Supply and Installation of Pole mount outdoor box with following specification:- size 600 mm x 400 mm x 300 mm (HxWxD) IP rating IP 66/67/68. Colour Grey Door Lock Type Single Lock System with metal lock LK-5 Thickness 1.2mm for enclosure and door Chassis Plate Zinc coated steel 1.5mm Finish. Paint finish epoxy polyester powder coating textured finish with necessary pole mounting accessories of approved make. All cable holes should be sealed with water proof sealant, cable entry only from bottom of box with 3 year onsite warranty
Installation of Real time Rain and Stream gauges at Thrissur and Ernakulam District
OD243118/2022-2023:Supply, installation, configuration, testing and commissioning of Data logger with minimum connectivity of 2 sensors having following features :- Inputs ports Analogue (1) 4 to 20 mA, SDI 12 (1), Digital (1) bidirectional and Pulse(1). Output ports, USB (1), RS 232(1), Telemetry Communication ports for GSM (2). Resolution 16 bit or better with plus or minus 1 with a transmission interval of 1 sec up-to 24 hours. Memmory 1 GB (min) Flash type. Internal Display,with provision to show each sensor data, battery voltage etc with internal battery for system clock (lithium iron type) with a storage capacity 2 years (minimum). With inbuilt input key pad, GPS clock synchronization, with corrosion resistant material in NEMA 4 enclosure, ambient temperature -20 oC- +60 oC, altitude up-to 5000 meter, with complete set of tool kit and user manual in English, Warranty 3 year onsite. Approved make: SEBA, OTT, Virtual, Trackertech, Cellcomm.
OD243119/2022-2023:Supply,installation, calibration,configuration,testing and commissioning of Radar type water level sensor having local display with following specifications:- Type :-Microwave non contact type, range 20 meter. Resolution 3mm or better, Resolution 0.02% Full Scale, beam angle less than 16o, Power Supply 12VDC, interfaces SDI 12/RS 485/4-20 mA Heart Protocol, with corrossion resistant material in NEMA 4 enclosure, ambiant temperature -20 oC- +60 oC, altitute upto 2500 meter, with complete set of tool kit and user manual in English, Warrenty 3 year onsite. Approved Make: Seba, Vega
OD243120/2022-2023:Supply,installation, calibration , configuration ,testing and commissioning of Rain Gauge with stand and floor/mast mounting accessories with following specification:- Tipping Bucket type with read switch with a capacity of 250 mm/hour rain or better, resolution 0.5mm or better,with minmum accuracy of 2%, interfaces SDI 12/RS 485/4-20 mA Heart Protocol, with corrossion resistant material in NEMA 4 enclosure, ambiant temperature -20 oC- +60 oC, altitute upto 5000 meter, with complete set of tool kit and user manual in English, Warrenty 3 year onsite. Seba, OTT, Virtual, Cellcomm.
OD243167/2022-2023:Supply,testing installation and commissioning of SMF batteries with 12 Volts 42 AH or above capacity with all necessary Connectors, cables and hardware mounting kit Approved Make Amaron Quanta, Exide Prosafe.
OD243199/2022-2023:Supply, Installation, Testing and Commissioning of BIS Certified Poly crystalline solar panels 80/100W as per IS/IEC standards, with Grade A solar cells with PID resistant technology. Open-Circuit voltage (Voc): 22 Volt, optimum operating current (Imp): 4.4 Amps or above , short-circuit current (Isc): 4.8 Amps or above . Modulus efficiency: 15.20% or above Warranty: 3 years on product and 25 years performance warranty
OD245368/2022-2023: Making of Fence, Gate and Foundations for ARG. The size of the fence 5 meter long X 5 meter wide X 2 meter height.The fencing must be made over a cement concrete enclosure which is 300 mm above ground level filled with rock aggregates of size 36 mm by a thickness of atleast 10 cm . Fencing angle size 40 mm x 40 mm x 6 mm and pre-coated with red-oxide. The total length of the fencing angle 2.8 meters i.e. (2.0m above ground level + 0.8 m below ground level). Two MS angles must be used diagonally at each of the four corner angles of the site. The angles can be attached (with welding or the other appropriate means) from the middle of the existing corner angle to the ground. The depth of the support will remain the same as of main angle. The dimensions of the fencing angle foundation should be 450 mm x 450 mm (length X width) and at a depth of 800 mm. Distance between each fencing angle 2.5 meter. Dimensions of GI Chain-link: 3 inches x 3 inches and of Gauge: 10 (3 mm diameter) GI chain-link mesh fixed properly on the fencing angles. A angle to be fixed on the upper part of the fencing . The chain-link fencing should be fastened with the help of screws fitted on the fencing angles. Gate Dimensions: 1 meter X 2 meter (Width x Height) with locking facility by MS Angle whose dimensions should be minimum 40 mm x 40 mm x 6 mm. locking facility with Rust proof Lock with3 keys Gate and MS Angle must be l painted with silver colour. Gate should have proper support of MS angles with additional support of crossed MS angles. Rain Gauge foundation. Rain gauge foundation must be of dimensions 450 mm x 450 mm (length x width) and 800mm deep. The rain gauge may be located so that it is at a minimum distance of 2 m away from obstructions on all four sides. The raised platform should be 230 mm above the ground level. In the case of flood prone areas the base plate on which the rain gauge is mounted should be placed 1.0 m above ground level. Sensor Supports and Brackets: - Aluminum or stainless steel - Sensor mounting supports and other accessories as required Proportions for concrete foundations Concrete pillar foundations for the mast fencing angle should be made in the volumetric mixing proportions as follows: Concrete foundation : 1 (Cement) : 2 (Sand) : 4 (Metal) Fine plastering : 1 (Cement) : 4 (Sand). Concrete Pillar must be cemented to achieve smooth finish above the ground level After 8 hours, these foundations should be cured with water at least 3 times a day for four days. The work includes the landscaping of fence area, removal of vegitations etc as required. The fencing angles, chain-link fencing and gate should be properly painted every year.All concrete foundations shall be painted using white cement paint every year, and the area should be cleared every year from any debries, vegitation etc.
OD245464/2022-2023:Supply and Installation of 4 meter long 150 mm diameter GI class B type pole with and offset of 60 cm from the height 1.5 meter above ground level/ without offset as required, mounted on the side of bridge or on a foundation as required. Painted with primer and two coat of white paint. The top of the pole should be covered with semi circular iron covering with at least 3 mm thickness protruding upwards without any dents to avoid any sort of ingress of water. The Pole should be provided with necessary provision for fixing data logger box, solar panel and Radar sensor. The pole top should be provided with 30 cm copper lightning arrester rod on a separate arm.
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
5.16:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
OD258750/2022-2023:Supply and Installation of Pole mount outdoor box with following specification:- size 600 mm x 400 mm x 300 mm (HxWxD) IP rating IP 66/67/68. Colour Grey Door Lock Type Single Lock System with metal lock LK-5 Thickness 1.2mm for enclosure and door Chassis Plate Zinc coated steel 1.5mm Finish. Paint finish epoxy polyester powder coating textured finish with necessary pole mounting accessories of approved make. All cable holes should be sealed with water proof sealant, cable entry only from bottom of box with 3 year onsite warranty
Relocating the existing Server
OD260279/2022-2023:Disassembling , relocating and transportation with specialized safety packaging and assembling the server rack with server and all accessories including the existing AC (2 nos - gas refilling included ), UPS, Batteries etc to the SDC of Hydrology at Jalabhawan, thiruvananthapuram. including disassembling the existing server, AC, UPS and batteries, packaging the components so as to ensure the components reach the destination in perfect condition, shifting, transportation and delivery charges, re installing and configuration of server, all necessary electrical and LAN cabling as required
BUSINESS INTELLIGENCE GROUP
Bidder Name
BUSINESS INTELLIGENCE GROUP
a dot computers
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .