Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-AOC DANGAPARA KANCHRAPARA | KANCHRAPARA | WEST BENGAL | L1 | Accepted-AOC Work Oder Issued | |
| 2 | L2₹2.1 L+₹7,076 (3.45%)Rejected-Finance B 16 280 KALYANI KALYANI NEAR KALYANI MUNICIPALITY NADIA WEST BENGAL 741235 | NADIA | WEST BENGAL | 741235 | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹2.4 L+₹34,316 (16.7%)Rejected-Finance 111 M C GARDEN ROAD KOL 30 | KOLKATA | WEST BENGAL | L3 | Rejected-Finance NOT L1 BIDDER |
| Sl No | Description | Qty | Unit | REFRICON L2 | Chatterjee Enterprise L3 | FREEZER L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply of 1.5/1.6 Ton Split type A.C. machine having the following specifications & features:-
a) Cooling capacity (Maximum) (BTU/HR): 18080; cooling capacity (Rated) Guaranteed (BTU/HR):18000, b) Star Rating -3 star, c) Rated Voltage - 230 V + / - 5%, Frequency - 50 Hz, d) Compressor type - Rotary, e) Mini. Room Discharge Air Flow Rate-950CMH, f) Refrigerant: R-410A/R-32, g) Cordless Remote Arrangement with all modernized provision of temperature setting, Fan speed option (Low / Medium / High) Auto Swing, h) Out door operating Temperature:- 50 C (Minimum), i) PCB control unit of indoor unit should be covered by metallic enclosure. (Make- O-General / Mitsubishi - Heavy) | 3 | Nos. | 64,500 ₹1,93,500 | 72,500 ₹2,17,500 | 58,880 ₹1,76,640 Lowest |
| 2.00 | Installation, Testing and commissioning of 1.5 Tr. Split AC Machine with IDU & ODU including supply & fixing of 40 mm x 40 mm x 5 mm MS angle iron brackets (powder coated) with necessary nut-bolt etc. & mending good the damages. | 3 | Nos. | 1,800 ₹5,400 | 2,200 ₹6,600 | 1,648 ₹4,944 Lowest |
| 3.00 | Supply & laying of following sizes Refrigerant Copper Pipes (Minimum thickness - 0.9 mm, Make - Royku / Totaline / Mandeep) with minimum 9 mm thick nitrile rubber insulation [Make - Aroflex/Acoflex] and also raping the insulation & copper wire with GKB Gold non adhesive tape - i) 6.35 mm (1/4") dia and ii)15.88 mm (5/8") dia including supplying & drawing of 4 core 2.5 sq. mm. P.V.C. insulated, stranded Copper Cable (Make - Havells / Finolex / RR Kabel) for connecting between the IDU and ODU. | 20 | Mtr. | 450 ₹9,000 Lowest | 500 ₹10,000 | 1,076 ₹21,520 |
| 4.00 | Supply & laying of 3/4" heavy type PVC pipe for Water Drainage as per direction. | 19 | Mtr. | 200 ₹3,800 | 250 ₹4,750 | 74 ₹1,406 Lowest |
| 5.00 | Supply & fixing of 240 V, 3-pin 16/20 A plug top (Make - Anchor) with connection. | 3 | Nos. | 120 ₹360 Lowest | 150 ₹450 | 158 ₹474 |
Tender Value
Refer Docs
EMD Value
₹4,161
Closing Date
23 Sept 2025, 10:50 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer
OFFICE OF THE ASSISTANT ENGINEER Kalyani Electrical Sub-Division, PWD Kalyani, Nadia
Supply and installation of A.C. machines 3 nos. at Pasteurs Lab of Dairy Microbiology Department at W.B.U.A.F.S., Mohanpur, Nadia.
2025_WBPWD_898960_1
WBPWD/AE/e-NIT- 04/KLY(3rd call) of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
WBUAFS, Mohanpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,161
OFFICE OF THE ASSISTANT ENGINEER Kalyani Electrica
10 Mar 2026
8 Sept 2025
25 Sept 2025
8 Sept 2025
23 Sept 2025
11 Sept 2025
10 Sept 2025
Amount
Supply of 1.5/1.6 Ton Split type A.C. machine having the following specifications & features:- a) Cooling capacity (Maximum) (BTU/HR): 18080; cooling capacity (Rated) Guaranteed (BTU/HR):18000, b) Star Rating -3 star, c) Rated Voltage - 230 V + / - 5%, Frequency - 50 Hz, d) Compressor type - Rotary, e) Mini. Room Discharge Air Flow Rate-950CMH, f) Refrigerant: R-410A/R-32, g) Cordless Remote Arrangement with all modernized provision of temperature setting, Fan speed option (Low / Medium / High) Auto Swing, h) Out door operating Temperature:- 50 C (Minimum), i) PCB control unit of indoor unit should be covered by metallic enclosure. (Make- O-General / Mitsubishi - Heavy)
Installation, Testing and commissioning of 1.5 Tr. Split AC Machine with IDU & ODU including supply & fixing of 40 mm x 40 mm x 5 mm MS angle iron brackets (powder coated) with necessary nut-bolt etc. & mending good the damages.
Supply & laying of following sizes Refrigerant Copper Pipes (Minimum thickness - 0.9 mm, Make - Royku / Totaline / Mandeep) with minimum 9 mm thick nitrile rubber insulation [Make - Aroflex/Acoflex] and also raping the insulation & copper wire with GKB Gold non adhesive tape - i) 6.35 mm (1/4") dia and ii)15.88 mm (5/8") dia including supplying & drawing of 4 core 2.5 sq. mm. P.V.C. insulated, stranded Copper Cable (Make - Havells / Finolex / RR Kabel) for connecting between the IDU and ODU.
Supply & laying of 3/4" heavy type PVC pipe for Water Drainage as per direction.
Supply & fixing of 240 V, 3-pin 16/20 A plug top (Make - Anchor) with connection.
REFRICON (BID ID -6924273)
Chatterjee Enterprise (BID ID -6924389)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .