Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.2 LAccepted-AOC 00 DEHAR VPO DEHAR SUNDER NAGAR MANDI HIMACHAL PRADESH 175030 | MANDI | HIMACHAL PRADESH | 175030 | L-1 | Accepted-AOC As per TEC Report | |
| 2 | L-2₹25.6 L+₹44,870.90 (1.78%)Rejected-Finance | L-2 | Rejected-Finance As per TEC Report | |
| 3 | Not Admitted-Fee/PreQual/Technical 133 DADRI ARYA SADAN JARCHA VILLAGE TOWN KALONDA CITY GAUTAM BUDDHA NAGAR GAUTAM BUDDHA NAGAR UTTAR PRADESH 201008 INDIA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201008 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Rejected-Technical 12 MAHIPUR 5 MAHIPUR NAWANSHAHR PUNJAB 144525 | SHAHID BHAGAT SINGH NAGAR | PUNJAB | 144525 | - | Rejected-Technical As per Approval of Competent Authority | |
| 5 | Rejected-Technical | - | Rejected-Technical As per Approval of Competent Authority |
Tender Value
₹24.1 L
EMD Value
₹48,000
Closing Date
10 Aug 2020, 6:55 pmClosed
Dy. General Manager (PnC)
Dy. General Manager(PnC) Parbati HE Project, Stage-II Parbati Complex, Nagwain Distt. Mandi (H.P) Pin - 175 121 Phone 1905 - 280112
Construction of 11 KV Line for Pancha Trench Weir Site of Parbati H.E Project (Stage-II) (Package No. C-581)
2020_NHPC_570853_1
NH/PP-II/PnC/Pkg No. C-581/2020
Open Tender
Electrical Works
Works
120 days
Pancha Trench Weir Site, Garsa Valley
As per Tender Document
8 documents required · 8 mandatory
₹590
Yes
NHPC Limited
₹48,000
Yes
4 Dec 2020
13 Jul 2020
17 Aug 2020
13 Jul 2020
10 Aug 2020
13 Jul 2020
Amount
Supply and Erection of Steel tubular Pole 09 Mtr Long, (approx. weight 154Kg) as per IS: 2713 Part-II-1980 in Cement concrete1:3:6(1 cement:3 course sand:6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
RCC Muff with concrete filling
Supply and erection of ACSR Dog Conductor of size 6/1/4.72 mm diameter and including binding etc as required.
Fixing of jumpers
Supply and Erection of galvenised stay set for 11KV overhead lines complete with19/20mm dia x1.8 metres long stay rod anchor plate of size 45cmx45cmx7.5mm thick thimble stay clamp turn buckle (20mmx600mm)7/3.15 mm dia GI Stay wire and 11kv strain insulator.
Supply and erection of 11KV Disc insulator for 11KV overhead lines with galvenised insulator fitting ball and socket type and complete with galvanised strain clamp, GI Bolts, nuts washers etc as required.
Supply and erection of 11KV Pin insulator for 11KV overhead lines with large steel head GI Pin, nuts washers etc (12KV, 10KN) as required.
Supply and erection of Channel Iron X Arms (2400x100x50x5) mm complete with fixing bolt nuts and washers, drilling holes for insulator pins painting with primer as required.
Supply and erection of Channel Iron X Arms (1070x100x50x5) mm complete with fixing bolt nuts and washers, drilling holes for insulator pins painting with primer as required.
Supply and erection of C I X Arms (75x40x6) mm complete : length 2800 mm with fixing bolt nuts and washers including drilling holes and painting with primer as required.
Supply and erection of AI X Arms (2800x50x50) mm complete with fixing bolt nuts and washers, drilling holes painting with primer as required.
Supply and Erection of a set of cross bracing frame work for 11 kV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 5 mm angle iron to form a rectangle using 1500 mm horizontal X 2125mm diagonal member, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes, bolts and nuts etc. and painting with primer and finish paint as required.
Supply and erection of AI X Arms 2x (750x50x50) mm complete with fixing bolt nuts and washers including drilling holes and painting with primer as required.
Supplying and erection of 50 mm X 8 mm M.S. flat iron pole top bracket for single 11 kV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc. and painting with primer and finish paint as required.
Supplying of Danger plate (250x200x1.6mm)
Providing and fixing barbed wire for anti climbing device.
Supply of Half Clamp( MS Flat 50x6mm) in 11KV overhead line
Supply of Full Clamp( MS Flat 50x6mm) in 11KV overhead line
Supply of Nuts, Bolts of different sizes (Galvanized/coated)
Supply and erection of GI Wire of size 8 SWG for continuous earthing including binding etc as required.
Erection of cradle guard as required
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Supply and erection of Gang Operated Air Break Switch unit 11KV, 400Amp
Supply and erection of Drop out fuse unit 11KV, 400Amp
Supply and erection of non linear resistor type lightning arrester (polymeric type) suitable for three wire 11KV overhead lines with rated voltage of 9 KVrms with a nominal discharge current rating of 5 KA and complete with galvanized clamping arrangement.
Painting two coats (excluding priming coat ) on steel and other metal surfaces with Aluminium paint, brushing to give an even shade including cleaning the surface of the dirt, dust and other foreign matter.
Supplying and Laying of one number XLPE power cable of 11 kV grade, of size 3x50 sqmm in the existing masonry open duct as required.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for size 35 sqmm of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.
Supply of Earth wire clamp Clamp in 11 KV Overhead line
LT Panel Distribution Box with MCCB (160A,40KA,4P 01No) & SFU (32A, rewirable 04Nos)
Supply , installation and commissioning of 11KV/0.415KV, 3 Phase, 100 KVA Delta/Star distribution transformer
Excavation in foundations, trenches etc., in earth work, lift upto 1.50 Metres stacking the excavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required in to plinths sides of foundations etc., consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed with in a lead of 20 metres. (A) Pick Work and (B) Spade work (50% of each)
Providing and laying cement concrete 1:4:8 (1 cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in: Foundation and plinth
Providing and laying cement concrete work 1:2:4 (1 Cement:2 Sand:4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and concrete work in :reinforcement for reinforced Foundations, footings bases of columns and the like and mass
Random rubble masonry/polygonal rubble masonry (uncoursed/brought to courses) with hard stones of approved quality in foundation and plinth including leveling up with (1 cement :6 sand : 12 graded cement concrete 1:6:12 stone aggregate 20mm nominal size) at plinth level in Cement Mortar 1:6(1 cement:6 sand) cum
15mm cement plaster in single coat on fair side of brick/concrete/stone walls for interior plastering upto floor two level including arrises, internal rounded angles, chamfers girth and finished even and angles not exceeding 80mm in and/or rounded (iv) Cement Mortar 1:6 (1 cement:6 sand).
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete
BHARAT ELECTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .