| # | Company | Amount |
|---|---|---|
| 1 | ₹8.8 Cr 2 44 A 4 KALU SARAI HAUZ KHAS DELHI SOUTH WEST DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | ₹8.8 Cr |
Tender Value
₹11.6 Cr
EMD Value
₹11.6 L
Closing Date
4 Jan 2025, 11:00 amClosed
Operation and Maintenance of Civil EandM services Internal and External including non medical equipment Horticulture work etc at Sports Injury Centre, Safdarjung Enclave, New Delhi-110029
NBCC/NIT/GM-RFM/SIC/06
NBCC/NIT/GM-RFM/SIC/06
Open Tender-Domestic
Support/Maintenance Service
South Delhi, Delhi
₹11,800
₹11.6 L
27 Jul 2026
19 Dec 2024
4 Jan 2025
4 Jan 2025
28 Jan 2025
1 Head- I :Civil Maintenance work
Comprehensive maintenance services and upkeep of all internal and external assets i/c under ground & over head tanks (cleaning twice in one year in every six
Months) at SIC campus , complete with all materials labour, T&P , machines , trucks etc. as required on all days including Sunday and holidays comprising of
following operations as per the details of SIC Buildings with external services as per enclosed GCC, Special & other conditions, specifications etc.complete and as
per direction of the engineer in charge.
Periodical cleaning & Maintenance of sewerage & drainage network manually or using Pressure jetting machines twice in a year or more, if required, i/c desiliting of
b) gully traps, manholes, gratings, chocked sewer line, water closet including all the vertical stacks of Sanitary and rain water pipes of all sizes i/c khurrah twice in a
year or more ,if required, to the entire satisfaction of Engineer - in - Charge.
Maintenance and cleaning of chajjas, cornice basement, roofs, expansion joints, waterproofing works etc., and removing of cobwebs, beehives, vegetation including
c) disposal of silt , vegetation, malba (including existing malba) etc. to the authorized dumping ground outside the campus at the location approved by MCD/NDMC
complete to the entire satisfaction of Engineer - in - Charge.
Maintenance and operation of water supply grid and valves in the entire campus to keep the water supply system efficient and operational at all times inclduing
necessary painting works to the entire satisfaction and as per direction of the Engineer - in -Charge.
Maintenance and repairing of Stone cladding including joint filling, crack repairing and replacement of stone, Zen Garden Structure Sculptures,damaged doors,
windows, ventilators of steel, aluminium, wood, PVC, False ceiling, trap doors all type of glass with fittings and consumables, stagging required including replacement
of broken glass panes etc. ( excluding replacement of Facade glass/Porch Glass / Facade Stone with its accessories) at all floors & heights i/c repair/ replacement of
necessary fittings & fixtures of approved make (or orginal make as per instruction of EIC) and quality, wherever required to keep them in proper functional conditions
to the entire satisfaction of the Engineer - in - charge (EIC).
Maintenance and repair of plumbing system of the entire campus including stopping leakages or over flow of water from PVC/RCC over head tanks ,cisterns and
replacement of damaged fittings i/c CP Brass fitting, ball cocks and G.I., PVC fittings sensor device, hand drier, soap dispenser, Mirror etc. to keep the entire water
f) supply system efficient and functional to the entire satisfaction of Engineer - in - charge . contractor shall replace all fittings which have lost its esthetic view, colour,
polish as per orginal installment with approved or original make as per instruction of EIC.
Maintenance and repair of internal & external plaster, repair and repaint of all area paints (external paint, textured paint, structural steel paint) flooring ,pavements,
pavor block masonry & RCC works, pointing on roof tiles , patch plaster on area upto 2.5 sqm and full plaster on area above 2.5 sqm,CC gola i/c fixing of W.C. seat,
g) gully trap, W.C trap, floor traps and sealing of leakages from gully trap, W.C trap, floor trap, drainage and vertical stacks, expansion joints etc. and restoration of
existing finishing in the affected areas to match with adjacent finishes and to the entire satisfaction of Engineer -in - charge.
Welding by electric plant/Machine including transportation of electric welding plant at site to weld broken grills, hinges, doors, windows, gates, railing and any other
steel work in building, parks, boundary walls, etc.complete as per direction of Engineer -in -charge .
Investigating causes of seepage / dampness/ leakage from roof, wall, floors, pipes expansion joints of all kinds etc., dismantling existing affected portion, arranging
i) required materials, labours, T&P, lift/ ladder or jhulla(if required) including taking all necessary measures, rectification complete in all respect in time bound manner
to the entire satisfaction of Engineer - in - charge .
j) Closing holes in walls, ceilings, floors or any wherelse including repairing with cement mortar to prevent entry of rats & others animals.
Recording & maintenance of the complaints register received at service centres in person or through telephone or email or any other mode and assigning the
complaint to the workers of respective trade.
Preparing the abstract of attended / unattended complaints on daily, weekly and Monthsly basis and submitting the same with reasons of unattended complaints and
action plan for redressal of pending complaint to the Engineer-in-Charge of NBCC (I) Ltd. or his authorized representative.
Cleaning of RCC/PVC water storage Under ground & over head tanks AND sumps twice in a year or more ,if required, by adopting 6 stage process i.e dewatering,
m) sludge removal, high pressure cleaning, vacuum cleaning, antibacterial spray and ultra violet- radiation i/c mentioning the date of cleaning on each tank. complete in
all respect to the entire satisfaction of the Engineer-in-charge.
Painting kerb stone, basement parking paint (repaint or touch up) , outer area parking paint inclduing restoration of existing finishing in the affected areas to match
with adjacent finishes and to the entire satisfaction of Engineer-in-charge.
All inclusive comprehensive maintenance, repair of all water incoming/outgoing lines as per terms and conditions and as per direction of Engineer -in-charge.
The contractor shall be mixing bleaching and chlorine of standard quality as per requirement in the drinking water supply. The rate shall be inclusive of all the material
and operation, labour etc. involved.
Weekly preventive maintenance shall be essentially carried out by deploying full team on Saturday and Sundays to check each & every civil , electrical, fire fighting,
fire alarm , pumps items etc and maintained the record .
Any other works in connection with the smooth operation & maintenance work not mentioned above ,but required to be carried out with in the cost and/ or also as
per direction of the Engineer -in - charge .
Boundary walls & maintenance of SS gates including all glass doors,Fire Exit doors inclduing providing necessary hardwares and painting of Fire exit doors as per
direction of the Engineer -in - charge .
t) All kinds of blinds (manual or motorised) shall be repaired, maintained as per direction of EIC
Cleaning & mopping of all HVAC plant room & equipments, HT/Transformer/LT/DG plant room & equipments, Fire fighting/Pump plant room & equipments, MLCP
room & equipments, stack parking & its equipments, lift & its equipments, FHC & its equipments, etc.
v) Repairing & upkeep of furniture ( beds/chairs/tables/drawers/almirahs etc.) or as per direction of EIC
Cost for Civil Maintenance for entire SIC Campus Months 12 1,081,677 12,980,129
Total for Head- I Civil Maintenance work 12,980,129
Total for Head- I: Civil 12,980,129
Digitally signed by RAJ PAL
Date: 2024.12.19 21:58:42 IST
2 Head-II:Electrical work
All inclusive comprehensive maintenance, upkeep of all electrical internal & external installations, Lights, LED sign board at entrances/terrace, Fans, Geysers etc. as
per details below at SIC campus, New Delhi for all days in a Months i/c holidays complete with materials , consumables etc as per terms and conditions attached
and as per direction of Engineer -in-Charge.
• Light points/ Fan pts/ Ex-fan pts./ Call bell pts.
• 5 amp plug points
• 15 amp power plug points
• 20/30 amp Ind. Power plug points
• Telephone outlet, TV Outlet
• Telephone wire, TV Wire
• Fluorescent light fittings
• All type of light fittings as per Terms & Condition
a) • Ceiling fans Months 12 696,706 8,360,476
• Ex-fans
• Call bells
• SP, SPN, TP & TPN MCB DB’s with MCB’s, Timers
• Bus Bars, Bus duct and Tap off box of different ratings
• Cable trays of different size
• 63 / 100 amps TP & N Switch units
• 125 Amp. TP MCCB’s
• All type of feeder pillars with switch gears etc.
• All HT, LT, UG cables for streetlights.
• And others as desired by Engineer-in-charge.
• All panels i/c UPS Panels and common area lights Street light, pump house, basement parking, STP etc.
Sub Total Cost for Electrical works 8,360,476
3 Head-III: Operation of Specialized E & M equipments
A) Sewerage Treatment plant (130 KLD MBR) and ETP 10 KLD
Operation of STP and ETP including all the materials for sewage /effulent treatment. Upkeepment of OLMS( Online Monitoring System asper DPCC/ CPCB guideline &
as per EIC.
Periodic Servicing of pumps on Quarterly basis and as when required.
i Months 12 325,877 3,910,527
All water lines, motor, pumps, electrical wiring, intake, any other Pump /machinery installed etc. in SIC Campus
Any other works in connection with the smooth operation & maintenance work not mentioned above ,but required to be carried out with in the cost and/ or also as
per direction of the Engineer-in-charge .
Supply of various chemical, consumables etc. for plant operation for based on MBR technology are followings.
ii UREA Kgs. 113 26.00 2,926
iii DAP Kgs. 75 69.00 5,176
iv Jaggery Kgs. 23 89.00 2,086
v Bio Culture Ltr 12 628.00 7,536
vi Sodium Hypo Chloride Ltr. 4220 29.00 122,367
vii Salt for Softener KG 9377 12.00 112,521
viii Gear oil Ltr. 59 521.00 30,533
ix Multi grade filter( Media), once in 1 year Kgs. 2540 11.00 27,935
x Pebble & Gravel for Activated carbon filter, once in 1 year Kgs. 781 11.00 8,595
xi Activated carbon for activated carbon filter, once in 1 year Kgs. 391 96.00 37,507
xii Softener Resin, once in 1 year Kgs. 781 195.00 152,372
xiii Bacteria/ Floating cubes Kgs. 234 2437.00 571,278
LAB CHEMICALS
Daily Lab testing of Inlet and Outlet water at Sewage Treatment Plant (BOD, COD, TSS, ph, Hardness, TDS, Total Coliform, Oil&Grease, etc.)
1. Test will be done on daily basis of inlet/outlet/treated water/soft water.
xiv 2. Frequency of testing of treated water on half yearly basis from NABL approved laboratory is also included in this price. month 12 35000.00 420,000
3. Cost of all chemicals to be used in testing and cost of calibration of lab equipment shall be included in this price
4. Test record will be maintained on daily basis.
NOTE: The contractror will maintain a regular IMIR (Inward Material Inspection register) for the cosumables.
materials required for ETP
xv Lime kg 365 33.00 12,045
xvi Alum kg 182.5 370.00 67,525
xvii Polyelectrolyte carbodate (powder form) kg 36.5 345.00 12,593
Sub Total 5,503,522
Total for STP/ETP 5,503,522
B) Fire Fighting System (24x7)
a) Operator with Helper as per SCC
b) Periodic Servicing of fire fighting Engine, Motors and pump (Quarterly and as & when required)
Digitally signed by RAJ PAL
Date: 2024.12.19 21:58:42 IST
All inclusive comprehensive maintenance of fire-fighting system i.e. including providing services for operation of wet riser system, Pumps in SIC Campus, round the
clock on all days of the year including Holidays (preventive maintenance shall be carried out on weekly off days with no extra payment) as per terms and conditions
attached i/c periodical fire testing, mock drill & obtaining fire NOC certificate from concerned department as & when becomes due on reimbursement basis.
Weekly preventive maintenance shall be essentially carried out by deploying full team on Sunday to check each & every fire fighting, pumps items etc. and
maintained the record including cost of (glan dori, coupling, pure oil).
e) Maintaining all hydrants, box, glass in neat condition as per instruction of EIC.
f) Periodic Servicing of fire alarm system, PA System etc. (Quarterly and as & when required)
All inclusive comprehensive maintenance of fire-system i.e. including providing services for operation of manual fire alarm, Pumps intercom & Lift intercom, PA System
g) in SIC Campus, round the clock on all days of the year including Holidays ( preventive maintenance shall be carried out on weekly off days with no extra payment )as
per terms and conditions attached.
Weekly preventive maintenance shall be essentially carried out by deploying full team on Sunday to check each & every fire alarm and maintained.
Cost for Fire Fighting System Months 12 153,905 1,846,861
Total for Fire Fighting System 1,846,861
C) Electric Sub-Station
Running, Operation & service maintenance of - 02 nos. 1600 KVA dry transformer at SIC Campus (with preventive maintenance maintenance ) complete with all
materials as per terms and conditions attached and as per OEM.
i) 1600 KVA Dry type indoor transformer 2 Nos.
ii) LT Panel for normal supply ,
iii) LT Panel for Generator Supply,
b) iv) Capacitor Panel
v) HT Breakers
vi) DC Aux. Panel & MDB
c) Servicing of the Transformer, HT, LT Panel in every Six Months or as per OEM
e) Any other item(s)/ work(s) in connection with above shall be carried out as per direction of the Engineer -in - charge .
Cost for Electrical Sub-Station Months 12 307,810 3,693,721
Total for Electrical Sub-Station 3,693,721
C) Rooftop Solar Power Plant, Solar Water Heater & Solar Street Lights
Running, Operation & service maintenance of all Rooftop Solar Power Plant, Solar Water Heater( replacement of Heating elements will be in the scope of maintenance
contractor as & when rqd or as per direction of EIC ) & Solar Street Lights at SIC Campus.
Cost for Electrical Sub-Station Months 12 76,953 923,430
D) DG Sets
Running, Operation & service maintenance of 2 Nos. 1010 KVA DG sets at SIC Campus as per OEM (with preventive maintenance) complete with all materials i/c
a) Mobil oil, grease etc. as per terms and conditions attached. (HSD shall be supplied by the contractor from authorized distributor and same shall be reimbused to
contractor upon production of orginal bill).
b) DG Sets: (i) 02 Nos 1010 KVA
d) Servicing of the DG Sets in every Six Months or as per OEM
e) Any other item(s)/ work(s) in connection with above shall be carried out as per direction of the Engineer -in - charge .
Cost for DG Sets Months 12 76,953 923,430
HSD Diesel : Fuel- To be reimbursed on the actual basis after providing original reciept of the same the rate will be fixed for entire period of one year .
f Ltrs 25200 87.67 2,209,284
Total for DG Sets 3,132,714
E) Lifts & Escalator
Providing services for running operations i/c cleaning and safety, security, watch & ward including cost of renewal of yearly license (on reimbursement basis),
a) replcement of lamps, ARD batteries, fans & other consumables of all seven passenger lifts and two nos. escalators on all days of the year including Sunday & Holidays
for hostel block only (including preventive maintenance) as per terms and conditions.
Cost for Lift Operation & Escalators Months 12 729,302 8,751,623
Total for Lift Operation & Escalators 8,751,623
F) HVAC Plant, Exhaust Ventilation system etc. (High & Low Side)
All inclusive day today service & maintenance i/c providing services for operation of HVAC Plant 4 x 300 TR and mechanical ventilation system in the whole building
with following equipment details: -
a) Chiller 4x300 TR, Primary Pump - 4 Nos., Secondary Pump - 4 Nos., Condensor Pump - 4 Nos., Hot Water Generator - 3 Nos., Hot Water Pump - 3 Nos., Pressure
Pump - 2 Nos., Cooling Tower - 4 Nos., Axial Fans, Inline Fans etc. i/c preventive maintenance and providing mechanic for regular service) as per terms and
conditions attached complete as per direction of Engineer-in -charge.
b) Manpower to be deployed for operation work as per terms & conditon of contract
c) Servicing of AHU's including washing/cleaning filters & coils of AHU as per instruction of EIC.
Cost for HVAC Months 12 384,763 4,617,152
Total for HVAC 4,617,152
Digitally signed by RAJ PAL
Date: 2024.12.19 21:58:42 IST
G) BMS System
a) Manpower to be deployed for operation work as per terms & conditon of contract
Operation and day-today Maintenance of IBMS (Integrated Building Management System), CCTV, LV works etc. as per terms and conditions and direction of engineer
–in-charge.
Cost for BMS System Months 12 136,744 1,640,929
Total for BMS System 1,640,929
H) CCTV, Internet, Wifi, Telephone, TV & AV
Operation and day-today Maintenance of the complete CCTV, Internet, Wifi, Telephone, TV & AV as per SCC as per terms & conditions and direction of engineer in
charge.
IT Engineer, IT Technician Operator, EPABX Technician as per terms & condition of contract. Renewal of License if any will be done by the contractor . No additional
cost will be paid for renewal of License.
Cost for IT, AV, EPBAX, system Months 12 186,744 2,240,929
Total for IT, AV, EPBAX, system 2,240,929
I) Water Treatment Plant
a) Manpower to be deployed for operation work as per terms & conditon of contract
b) Operation and day-today Maintenance of WTP as per terms and conditions and direction of engineer–in-charge.
Cost for WTP Months 12 174,804 2,097,646
Total for WTP 2,097,646
J) Sub Head- VI (Non Medical Equipments)
a) Operation & service & routine maintenance of PTS Months 12 111,146 1,333,757
b) Operation & service & routine maintenance of PWLCS Months 12 65,250 783,003
c) Operation & service & routine maintenance of AVSRS Months 12 65,250 783,003
d) Operation & service & routine maintenance of CSSD Months 12 336,632 4,039,581
e) Operation & service & routine maintenance of TSSU Months 12 234,376 2,812,513
f) Operation & service & routine maintenance of MOT Months 12 222,293 2,667,513
g) Operation & service & routine maintenance of MGPS Months 12 398,689 4,784,273
h) Operation & service & routine maintenance of Laundary Services Months 12 231,764 2,781,165
Sub total of Sub Head- VI (Non-Medical Equipment and Laundary Services ) 19,984,808
K) Sub Head- VII (Automatic/Multilevel Car Parking and Stack Car Parking)
i) Providing Services of Highly Skilled Operator for Automatic Car Parking Months 12 147,371 1,768,447
ii) Providing Services of Drivers for Multilevel/stack Car Parking Months 12 182,325 2,187,906
Sub total of Sub Head- VII (Automatic/Multilevel Car Parking and Stack Car Parking) 3,956,353
Total for Head-III: Operation of Specialized E & M equipments 58,389,688
5 Head- IV (Maintenance and upkeep of horticulture work)
Maintenance and upkeep of Horticulture (Indoor and outdoor in all areas) including manure, fertilizer, DAP, good earth etc required for proper maintenance. Carry out
a) Months 12 132,765 1,593,176
all necessary seasonal operations for Horticulture works.
b) Provision for Development of Horticulture works including 2000 nos. Flowering plants in each season every year as per direction of EIC) L.S. 1 400,000 400,000
Sub total of Head- IV (Maintenance and upkeep of horticulture work) 1,993,176
6 Head- V (Operation and Maintenance of Swimming Pool)
Operation and Maintenance of Swimming pool including maintenance of water filtration system installed for swimming pool with consumables and life guards as
Months 12 49,124 589,482
required for smooth functioning of swimming pool.
Sub total of Head- V (Operation and Maintenance of Swimming Pool) 589,482
Head - VI (Day to day requirement of E&M items)
1 NS Supply & fixing of LED 09W Downlighter with all accessories. Ref make: Philips or equivalent from other approved makes. Nos. 100 3,200 320,000
2 NS Supply & fixing of LED 10W Downlighter with all accessories. Ref make: Philips or equivalent from other approved makes. Nos. 100 3,200 320,000
3 NS Supply & fixing of LED 15W Downlighter with all accessories. Ref make: Philips or equivalent from other approved makes. Nos. 200 3,500 700,000
4 NS Supply & fixing of LED 14W Batten (T5) Mirror Light with all accessories. Ref make: Philips or equivalent from other approved makes. Nos. 100 900 90,000
5 NS Supply & fixing of LED 20W Batten with all accessories. Ref make: Philips or equivalent from other approved makes. Nos. 100 900 90,000
6 NS Supply & fixing of LED 36W 2x2 fixture with all accessories. Ref make: Philips or equivalent from other approved makes. Nos. 300 4,500 1,350,000
7 NS Supply & fixing of LED 36W 1x4 fixture light with all accessories. Ref make: Philips or equivalent from other approved makes. Nos. 30 5,500 165,000
Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable
8 15.1 type, suitable for connected load upto 10Amp, for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c Each 195.00 4694.04 915,338
programming at site etc. complete as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
9 1.17.12 metre 1950.00 139.74 272,493
Digitally signed by RAJ PAL
Date: 2024.12.19 21:58:42 IST
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
10 1.17.21 metre 1950.00 210.12 409,734
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in
11 1.21.2 case of recessed conduit as required. metre 1950.00 147.9 288,405
Supply, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and
fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal
conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building
12 16.2.14 etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size mtr 500.00 886.38 443190.00
above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum
7mm thick MS C338sheet for pipes of 400 mm dia and above.
25 mm dia (19 mm thick insulation)
Supply,installation,testing and commissioning of 24-port 10/100/1000BaseT PoE+ 10/100/1000BASE-Tconnector type RJ-45 GbE SFP optic/connector type: RJ45, or
13 NS nos. 10.00 119500 1,195,000
LC SFP fiber supporting 1000BASE-T SFP, SX (multimode), LX (single mode), or LH (single-mode)
Supply,installation,testing and commissioning of Full HD IP Dome Camera Equipped with 2 MP CMOS Sensor,Max. 30fps@2M all resolutions (H.265/H.264), Motion
14 NS Nos. 32.00 21370 683,840
detection, Tampering, Defocus detection Hallway view (90°/270°), LDC support Micro SD/SDHC/SDXC memory slot (Max. 128GB)
15 NS Supply,installation,testing and commissioning of 24 port Loaded Jack Panel for CAT6A cable termination at rack end Data Active Voice Nos. 10.00 8700 87,000
16 NS Supply,installation,testing and commissioning of 24 port Loaded Staggred Jack Panel for CAT6 cable termination at rack end Nos. 10.00 5800 58,000
17 NS Suply and Laying of PVC Flexible Pipe (25 MM) (Reinforce) RM 100.00 55 5,500
Supply & fixing of RJ45 connector for fast and easy verification of wire sequence. Operating temperature -40ᴼ to 70ᴼC Current rating 1.5Amps Dielectric withstanding
18 NS Nos. 50.00 8 400
voltage 1000Volts AC RMS 60Hz, 1 minute Contact resistance ≤ 20mΩ @ 100mA max. 50mV max.
Supply & fixing of CAT6A patch cord 1 Mtr (3feet) for information outlet (I/O) to Rack End Redantant device connectivity.High Speed Gigabit 24AWG
19 NS Nos. 240.00 280 67,200
U/UTP Patch Cord, LSZH, C6
Supply & laying of CAT 6A UTP cable 23 AWG solid copper conductors for Connectivity of CCTV to End Point.High Speed Gigabit Ethernet U/UTP, 250
MHz, Class E, 23 AWG, Unshielded LSZH Cable, C6
21 NS Supply, Installation, Testing & Commissioning of WIRELESS RF, 5GHz 300Mbps 13dBi Outdoor CPE for lift camera connectivity Pcs 14.00 6844 95,816
Supply, Installation, Testing & Commissioning of NVR Up to 32CH, 32MP Resolution
* Max. 400Mbps network camera recording
* HDMI out
* User friendly UI / UX
22 NS Dynamic Event support Pcs 2.00 165200 330,400
- New event function of cameras is available without software update
* Bookmark management (Up to 100 set)
* H.265, H.264, MJPEG compression support
* SATA 8ea (Up to 80TB)
23 NS 10 H.P Motor: Motor Rewinding Nos. 2 7500 15000
24 NS 10 H.P Motor: Bearing 630822 C-3 SKF Nos. 4 880 3520
25 NS 10 H.P Motor: Motor Opening Fitting and Alignment Charges Nos. 2 3000 6000
26 NS 7.5 HP Jockey/Sprinkler Pump: Mechanical Seal Nos. 4 5500 22000
27 NS 7.5 HP Jockey/Sprinkler Pump: Seal Plot Nos. 4 1625 6500
28 NS 7.5 HP Jockey/Sprinkler Pump: Bearing 6309 SKF 22 Nos. 4 1250 5000
29 NS 7.5 HP Jockey/Sprinkler Pump: Shaft Nos. 2 7500 15000
30 NS 7.5 HP Jockey/Sprinkler Pump: Neck Ring Nos. 4 1450 5800
31 NS 7.5 HP Jockey/Sprinkler Pump: Pump Opening Fitting and Alignment Charges Nos. 2 6624 13248
32 NS Diesel Engine fire Pump: Mechanical Seal Nos. 2 12500 25000
33 NS Diesel Engine fire Pump: Seal Plot Nos. 2 2500 5000
34 NS Diesel Engine fire Pump: Sleeve S.S D.E Nos. 1 9500 9500
35 NS Diesel Engine fire Pump: Sleeve S.S N.D.E Nos. 1 6800 6800
36 NS Diesel Engine fire Pump: Bearing 7312 Nos. 2 12077 24154
37 NS Diesel Engine fire Pump: Bearing NU 312 SKF Nos. 1 8944 8944
38 NS Diesel Engine fire Pump: O Ring Set Nos. 1 800 800
39 NS Diesel Engine fire Pump: Pump Opening Fitting and Alignment Charges Nos. 1 10000 10000
40 NS Main Hydrant Pump: Mechanical Seal Nos. 4 4365 17460
41 NS Main Hydrant Pump: Sleeve C.I Nos. 4 1500 6000
42 NS Main Hydrant Pump: Seal Plot Nos. 4 1275 5100
43 NS Main Hydrant Pump: Bearing 3307 SKF Nos. 2 4486 8972
44 NS Main Hydrant Pump: Bearing 6307 SKF Nos. 2 650 1300
45 NS Main Hydrant Pump: Neck Ring C.I Nos. 4 2850 11400
46 NS Main Hydrant Pump: Pump Opening Fitting and Alignment Charges Nos. 2 6624 13248
47 NS Main Hydrant Pump: Shaft Nos. 2 6500 13000
48 NS Sump Pump: Motor Rewinding Nos. 2 2000 4000
49 NS Sump Pump: Mechanical Seal Nos. 2 1875 3750
50 NS Sump Pump: Bearing 6205 22 SKF Nos. 2 370 740
Digitally signed by RAJ PAL
Date: 2024.12.19 21:58:42 IST
51 NS Sump Pump: Bearing 6204 22 SKF Nos. 2 3001 6002
52 NS Sump Pump: O Ring Set Nos. 2 200 400
53 NS Sump Pump: Oil Nos. 2 300 600
54 NS Sump Pump: Cable Nos. 2 180 360
55 NS Sump Pump: Impellar & Body Repair Nos. 2 2000 4000
56 NS Sump Pump: Pump Opening Fitting and Alignment Charges Nos. 2 2000 4000
57 NS Sump Pump 4/5 HP Cutter Pump: Motor Rewinding Nos. 2 5000 10000
58 NS Sump Pump 4/5 HP Cutter Pump: Mechanical Seal Nos. 2 3200 6400
59 NS Sump Pump 4/5 HP Cutter Pump: Bearing 6305 22 SKF Nos. 2 430 860
60 NS Sump Pump 4/5 HP Cutter Pump: Bearing 6205 22 SKF Nos. 2 370 740
61 NS Sump Pump 4/5 HP Cutter Pump: O Ring Set Nos. 2 200 400
62 NS Sump Pump 4/5 HP Cutter Pump: Oil Nos. 2 300 600
63 NS Sump Pump 4/5 HP Cutter Pump: Pump Opening Fitting and Alignment Charges Nos. 2 3000 6000
Supplying, Installation, Testing and commissioning of Non-clog fully automatic Dewatering (Sewage) Pump, 5 HP, Three Phase, 415 Volts, Size 65mm. Handling
type of Screened sewage, Raw sewage' Contaminated effluents, Industrial waste water, Storm water, Trench and tunnel water, Drain water, mine water, etc. Motor is
dry type submersible and cooled by liquid being handled. Motors are air tested for leakfree operation. Degree of protection for motor is IP68 as per IS:2147 Class of
insulation : F, Voltage : 415V 10%, Frequency : 50 Hz. 5%, Type of starting : As per requirement (DOL/Star Delta/ATS), Non-clog two vane or single vane enclosed
impeller, Permissible solid size up to 40 mm, Gland packed/mechanical seal, 50 HZ/60 HZ availability , Delivery size up to 65 mm, Capacity up to 720 m3/hr, Head up
64 NS to 25 metres. ( reference make: Kirloskar model ETERNA 3700 CW+ or equivalent from approved makes) Set 2 75000 150,000.00
(02 No. of pump Set with all electrical & plumbing fittings.)
40 mm solid handling capacity
Minimum Capacity - 1200 LPM
Minimum Head - 25 Mtr
Minimum Power - 5HP/3.7 KW
65 NS Supplying & fixing of Panic Bar (Double LEAF) PCS 50 17,275 863,750
66 NS Supplying & fixing of Trim with Handle PCS 50 5,039 251,950
67 NS Supplying & fixing of Fire rated Glass with Fire seal PCS 50 4,450 222,500
68 NS Supplying & fixing of Door Closer PCS 50 1,450 72,500
69 NS Supply, Installation, Testing & commissioning of 30KVA Online UPS , Complete as required. SET 1 411,171 411,171
70 NS Supply, Installation, Testing & commissioning of 80KVA Online UPS , Complete as required. SET 1 1,096,456 1,096,456
Supply & Installation of high discharge sealed maintenance free battery of 12V 100AH for UPS inculding deduction for unserviceable batterys (Rs.150) complete as
71 NS nos. 186 11,563 2,150,685
required. (Reference make & model:Exide Power Safe Plus SMF 12V 100Ah UPS Battery or equivalent from other approved makes)
Supply & Installation of high discharge sealed maintenance free battery of 12V 120AH for UPS inculding deduction for unserviceable batterys (Rs.150) complete as
72 NS nos. 36 13,806 497,016
required. (Reference make & model:Exide Power Safe Plus SMF 12V 120Ah UPS Battery or equivalent from other approved makes)
Supply & Installation of high discharge sealed maintenance free battery of 12V 9AH/12AH for Lifts inculding deduction for unserviceable batterys (Rs.150) complete
73 NS nos. 32 2,200 70,400
as required. (Reference make & model:Exide Power Safe Plus SMF 12V 9AH/12AH UPS Battery or equivalent from other approved makes)
74 NS Servicing i/c Gas Charging in Split ACs installed in Server and UPS Room - 16 Nos. Each 16 3,540 56,640
Periodical Servicing (Two times in a Year), B-check & CAMC of DG Set 2 Nos. 1010 KVA each with all spare parts, consumables, emergency breakdown, periodic lot (six
service etc. without supply of Diesel or as per direction of EIC. monthly)
lot (six
76 NS Periodical Servicing (Two times in a Year) of HVAC plant, chillers, cooling tower, hot water generator & allied equipments. 2 880,130 1,760,260
monthly)
Re-filling of all types of fire extinguishers ( e.g. 4.5 kg CO2 Type, 4 kg ABC type, 9 Litre water CO2 type etc.) including transporation to & fro get to be done as per
77 NS Nos. 232.00 450 104,400.00
DFS/ manufacturers recommondations .
Supply, Installation, Testing & Comissioning of 50Amp 3Pole Power Contactor. (Ref Make: L&T MO-50, 50A, 3 pole Power Contactor or equivalent from other approve
78 NS Nos. 2.00 11206 22,412.00
makes)
Supply, Installation, Testing & Comissioning of 400/5 Amps 15VA Resin Current Transformer, complete as required. Ref Make: Newtek Model NE4B312 400/5A, 15VA
79 NS Nos. 8.00 1179 9,432.00
Class-1, 0.7/3KV or from other equivalent approved makes)
80 NS Supply & installation of 50 feet (15 mtr) battery operated Hydraulic Mobile Scissor lift, complete in all respect or as per direction of EIC. Set 1.00 897723 897,723.00
TOTAL OF HEAD-VI Day to day required Electrical & Mechanical items 17,418,452
Head-VII Day to day required Civil items
1 13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. sqm 1000.00 267.95 267954
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the
surface even and smooth complete.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture,
3 13.81.1 including applying additional coats wherever required, to achieve even shade and colour. sqm 12,000.00 63.95 767448
Old work (One or more coats)
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including
4 13.82.1 applying additional coats wherever required, to achieve even shade and colour. sqm 3,000.00 93.84 281520
one coats.
Digitally signed by RAJ PAL
Date: 2024.12.19 21:58:42 IST
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including
5 13.82.2 applying additional coats wherever required, to achieve even shade and colour. sqm 3,000.00 140.20 420597
Two coats.
White washing with lime to give an even shade :
Old work (One or more coats)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
One or more coats on old work.
Finishing walls with water proofing cement paint of required shade :
Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat.
Finishing Walls with Acrylic Smooth Exterior paint of required shade:
Old work ( Two or more coat applied @1.67ltr/10 sqm ) on existing cement paint surface.
10 13.114 Melamine polishing on wood work (one or more coat). sqm 500.00 140.86 70431
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat,
11 13.52.2 preparation of surface, etc. complete. sqm 1000.00 239.85 239853
On concrete work
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having
12 21.10 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, Sqm 800 5,098 4,078,123
drawings and direction of Engineer-in-charge complete
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium
quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as
13 25.1 approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame kg 100 422.59 42,259
work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose
of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as
curvilinear portions of the building for all heights and all levels, including:
(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof
test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses,
aluminium cleats, sleeves and splice plates etc.
gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)
cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection
against fire hazard including:
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3
Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building
structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the
14 25.2 required capacity and in required numbers. Sqm 400 3,581 1,432,284
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of
required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade,
brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the
gap between the building structure and all its interfaces with curtain glazing to make it watertight.
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization,
providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of
all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including
wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the
structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all
mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with
Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade
Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of
SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather
sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings.
The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the
15 25.8 perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. Sqm 50 9,692.4 484,620
The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including
wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose
of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Digitally signed by RAJ PAL
Date: 2024.12.19 21:58:42 IST
Providing and fixing of façade at all heights with extruded hollow Clay / Terracotta ventilated rainscreen tiles of height 259/ 309/ 409mm and lengthof 1190 mm of
approved texture,design and pattern having Flexural Strength/ Modulus of Rupture of > 14 N/m² and maximum water absorption of 10% tested as per ISO 10545-
4:2004(E) and ISO 10545-3:1995 respectively in true level fixed to a supporting aluminium framework (Alloy 6063 T5/T6) consisting of vertical 'T' (for
intermediates)/ 'L' (for ends/ termination)/ Tubular sections (at corners)of size 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum spacing of
1200mm c/c matching to the tile vertical grid, and horizontal aluminium 'C'-clamps of size 56x34x2 mm thickness of length 150mm at junction of tiles and of length
75mm at wall ends/ corners fixed on top of the vertical sections at spacing of 250/ 300/ 400mm c/c matching to the tile horizontal grid with two numbers of self
drilling / self-tapping SS screws of size 5.5x25 mm with EPDM washers.The vertical 'T'/'L/ Tubular' sections shall be fixed to the wall using HDG (hot-dip-galvanized)
steel L-brackets (galvanizing thickness of minimum 80 microns) of size 110x80x6 mm at intermediate vertical aluminium profiles and of size 220x110x12 mmat outer
corners and stainless steel grade 304,M10 full threaded anchor fasteners with nylon sleeve 100mm long (for brick work) and M8 expansion anchor fasteners 75mm
long for concrete surface, spacing of brackets to be based on a structural/ static calculation. The brackets shall be of length 175mm at junction of two vertical
aluminium profiles and of length 100mm at intermediate points of vertical profiles and shall be fixed to the vertical aluminium T / L / Tubular profiles using two
numbers self-drilling/ self-tapping SS screws of size 5.5x25 mm with EPDM washers.“EPDM gaskets to be fixed in between brackets and vertical profiles. The tiles shall
be mounted on the ‘C’ clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be mounted on the C-clamps with EPDM profiles in
between such that the tiles are supported at top and bottom at both ends. The vertical joint open groove between two adjacent tiles shall be 10mm. The tiles and
system shall be designed to resist wind load as per IS 875 (Part 3) according to different zones. The tiles shall be installed using the ventilated rain screen principle
with provision for natural ventilation of the space between the façade tiles and the structural wall. The work shall be carried out as per specification, drawing and as
per direction of the Engineer-in-Charge. Note : Scaffolding wherever required to be paid separately.
With 24mm thickness (+/- 10%) terracotta tiles of other than grey colors
Providing and fixing in wall lining medium density fibre board IS: 14587:1998 marked, Pre-laminated one side decorative lamination and other side balancing
17 9.158.1 lamination, with necessary fixing arrangement and screws etc. complete. sqm 60 1,237.01 74,220
12 mm thick.
Providing and fixing white vitreous china extended wall mounting water closet of approved shape including providing & fixing white vitreous china cistern with dual
18 Non-DSR flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.(Ref. make: each 20 11952.00 239040
Jaquar wall mounted or equivalent from other approved makes)
19 Non-DSR Providing and fixing of Health Faucet with metal hose and holder in Polished Chrome alongwith all necessary accessories complete including cutting, making good the each 100 1278.00 127800
walls, floors, slab wherever required as per direction of Engineer-Incharge. , (Ref. make:Jaquar or equivalent from other approved makes)
Providing and fixing white vitreous china flat back half stall urinal with fittings, standard size C.P. brass flush pipe, waste fittings bottle trap, with unions and
20 Non-DSR each 20 13706.00 274120
clamps (all in C.P. brass) other couplings in C.P. brass, alongwith all necessary accessories complete including cutting, making good the walls, floors,
slab wherever required as per direction of Engineer-Incharge. (Ref. make: Jaquar or equivalent from other approved makes)
Providing and fixing of White vitreous china under counter Wash Basin with CI bracket, including bottle trap and waste coupling 32 mm half threaded including
21 Non-DSR painting of fitting & bracket, cutting and making good the walls, floors, slab wherever required as per direction of Engineer-Incharge. (Ref. make: Jaquar or equivalent each 20 4298.00 85960
from other approved makes)
Providing and fixing of White vitreous china Table top Wash Basin with CI bracket, including bottle trap and waste coupling 32 mm half threaded including painting of
22 Non-DSR fitting & bracket, cutting and making good the walls, floors, slab wherever required as per direction of Engineer-Incharge. (Ref. make: Jaquar or equivalent from other each 20 6853.00 137060
approved makes)
Providing and fixing of Basin Mixer alongwith all necessary accessories complete including wall flange,cutting & making good the walls, floors, slab wherever required
23 Non-DSR each 20 3775.00 75500
as per direction of Engineer-Incharge. (Ref. make: Jaquar or equivalent from other approved makes)
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm
24 Non-DSR Sqm 20.00 3101.00 62020
thick hard board backing:
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard
25 9.21.1 wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: Sqm 84.00 2440.50 205002.252
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc.
complete.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped
galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of
size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum)
sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size
24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size
24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings,
27 12.52.2 fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia Sqm 72.00 2110.13 151929
and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised
butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted
with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of
100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester
powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Digitally signed by RAJ PAL
Date: 2024.12.19 21:58:42 IST
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped
galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of
size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum)
sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size
24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size
24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings,
28 12.52.4 fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia Sqm 108.00 1558.56 168324.48
and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised
butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted
with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS:
2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non
woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:
29 11.41.2 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm 100 1584.519 158451.9
sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:
30 11.41.4 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm 200 2131.443 426288.6
sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 1000x1000 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to
IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement
31 11.41A.3.1 slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . sqm 100 1494.147 149414.70
Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Glazed Vitrified tiles Matt/Antiskid finish of size
Size of Tile 600 x 600 mm
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the
architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement
32 11.55.1 slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as Sqm 200.00 3250.43 650086.8
directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
33 Non-DSR Supply & Installation of Digital Water flow meter(ISI mark) with required nut bolts and flange etc. complete as required. Size 80mm Set 4.00 52274.00 209096
Providing and applying 2.5 mm thick road marking strips (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic
thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on
road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of
Engineer-in-charge and accordance with applicable specifications.
35 NS Supply & installation of Signages with all required accessories or as per direction of EIC. Sqft 300.00 2467.00 740100
TOTAL HEAD -VII OF Day to day required CIVIL ITEMS 16633304.38
Digitally signed by RAJ PAL
Date: 2024.12.19 21:58:42 IST
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT.pdf
Tender Document
ABSTRACT.pdf
Tender Document
CS_cover_2_QuotingSheet.xlsx
Tender Document
BOQ.pdf
Tender Document
Scope of Work.pdf
Tender Document
SCC.pdf
Tender Document
2_GCC PMC 2022 upto 11 amendments.pdf
Tender Document
corrigendum-3390-corrigendum 03.pdf
pdf • 0.17 MB
corrigendum-3243-corrigendum 02.pdf
pdf • 0.22 MB
corrigendum-3222-CORRIGENDUM 01.pdf
pdf • 0.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .