Loading…
Loading…
Tender Value
₹3.1 L
EMD Value
₹4,000
Closing Date
8 Oct 2026, 6:00 pmClosed
Executive Engineer,Tapi (R & B) Division,Vyara
Construction of Chemistry Lab Platform of EMRS School at Indu,Tal.: Vyara, Dist.: Tapi.
350542
16 OF 2026-27
Open
Civil Works
Works
Tapi
15 documents required · 14 mandatory · 1 optional
₹600
Executive Engineer,Tapi (R & B) Division,Vyara
₹4,000
30 Sept 2026
30 Sept 2026
30 Sept 2026
8 Oct 2026
30 Sept 2026
Construction of Chemistry Lab Platform of EMRS School at Indu Tal.: Vyara, Dist.: Tapi.
BILL OF QUANTITIES
Percentage Rate Tender
Item Description of Item Quantity Unit Rate In Amount
1 Dismentaling Platform of Granite laid in mortar including 15.60 Sq.m. 49.41
stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift.
2 Providing and fixing 1.2 meter wide sand which type 26.00 Sq.m. 6273.11
counter platform including supplying and fixing granite
stone of Z black or equivalant quality 18 mm thick mirror
polished on top and side posiition and vertical strip at
front with cement slurry & adhesive including moulding
of both exposed edges over 25 mm granite platform
fixing in top and sides and itermediates supports fixing
with cement mortar and adhesive and finishing all
material and labour and assessories etc. complete etc.
3 Providing and fixing Lab sink with C.I. or M.S. brackets, 11.00 No. 2326.66
painted white including cutting holes in walls and making
good the same but excluding fittings. (C) Vitreous China
sink.(i) 600mm x 450mm x 150mm size.
4 Providing and fixing C.P. brass waste for washbasin or 11.00 No. 120.98
sink. (A) 32mmdia. +Waste Pipe for Wash basin C.P.
5 Providing and fixing PVC SWR Nahni trap IS 14735 for 11 No. 585.37
drain 100 mm diameter with jali of the following nominal
diameter of self cleansing design with C.I scread down or
hinged grating including the cost of cutting and making
good the walls..
6 Providing and fixing screw down bib taps of following 21 No. 186.83
size.(A) Brass screw down bib tap polished bright. (i)
7 Providing and fixing Gun metal check or non-return 5 No. 420.63
fullway wheel valve. 25mm. dia.
8 Providing and fixing Gun metal check or non-return 5 No. 663.43
fullway wheel valve. 40mm. dia.
9 Providing laying and jointing in true line and level 15mm 40.00 Rmt. 72.65
dia. U.P.V.C. Pipe (SCH-40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two
metre C/C or shall be concealed as directed including
necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost
of all materials.
Item Description of Item Quantity Unit Rate In Amount
10 Providing laying and jointing in true line and level 25mm 90.00 Rmt. 91.84
dia. U.P.V.C. Pipe (SCH-40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two
metre C/C or shall be concealed as directed including
necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost
of all materials.
11 Providing laying and jointing in true line and level 40mm 100.00 Rmt. 148.12
dia. U.P.V.C. Pipe (SCH-40) for cold water Including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two
metre C/C or shall be concealed as directed including
necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost
of all materials.
12 Providing, laying and jointing in true line and level 30.00 Rmt. 857.65
110mm diametre U.P.V.C (Type B) conforming to IS 13592-
1992 with one end plain and other end socketed with
rubber ring, & fittings conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe shall
be jointed with each other with rubber lubricant, pipe
shall be fixed on wall using of PVC clamp of the size
mm diametre x 149 mm length x 145 mm heigh at every
2000 mm center to center or shall be concealed in walls
as directed including necessary fittings such as bends,
shoes etc. including testing of pipes and joints and jointed
with adhesive solvent cement including cost of all
13 Providing, laying and jointing in true line and level 75 mm 120.00 Rmt. 293.91
dia. UPVC SWRType B pipe conforming to IS 13592-1992
with one end plain and other end socketed with
rubbering and fitting conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe shall
be jointed with each other with rubber lubricant, pipe
shall be fixed on wall using of PVC clamp at every
mm c/c or shall be conceled in walss as directed including
necessary fittings such as bends, shoes etc. including
testing of pipes and joints and jointed with adhesive
solvent cement including cost of all materials.
Item Description of Item Quantity Unit Rate In Amount
14 Constructing brick masonry chamber for underground C.I. 2 No. 2932.93
Inspection chamber and bends with briocks having
croshing strength not less than 35Kg. Cm2 in C.M. 1:5 C.I.
cover with frame (Light duty) 455mm x 610mm intenal
dimensions total weight of cover with frame to be not
less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame
15Kg.) (R.C.C. top slabe with 1:2:4 mix (1-cement 2-
coarse sand 4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick
with cement mortar 1:3 finished smooth with a floating
coat of neat cement on walls and bed concrete etc.
complete.(i) Inside dimensions 455mmx 610mm and
450mm deep for single pipe line.
15 Providing and fixing in position cowel went to pipes. (C) 2 No. 505.17
16 Providing erecting and fixing double coated PVC (ISI) 2000 Ltr. 3.95
water tank of required capacity each with all necessary
fittings and connection etc. complete on terrace.
Rupees Three Lacs Eight Thousand Three Hundred Thirty Seven Only
I/We am/are willing to carry out the work at………………….% above/below percent(Should be written in figures and words) of
the estimated rate mentioned above. Amount of my /our
Tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
In words In words
The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-
Charge for which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 Income tax TDS will be deducted at a source while making payments of bills
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017
Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change
4 as per actual mix design the cost of difference of cement consumption have been deducted from the rate of original
item at the rate of input rate mentioned in all the tender.
Executive Engineer
Tapi ( R & B ) Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD-lab platform.pdf
BOQ-lab platform.pdf
SPECIFICATIONS-lab platform.pdf
Building booklet.pdf
GR Clouse 24 iv 34 52.pdf
GRs compress.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .