Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-technical | Admitted-technical |
| 2 | Admitted-technical | Admitted-technical |
| 3 | Admitted-technical | Admitted-technical |
| 4 | Admitted-technical | Admitted-technical |
| 5 | Admitted-technical | Admitted-technical |
Tender Value
Refer Docs
Closing Date
14 Aug 2026, 5:30 amClosed
NHIT Southern Projects Private Limited
Unit 325, 3rd Floor, D21 Corporate Park, Sector 21, Dwarka, Dhulsiras, New Delhi-110077
Request for Proposal (“RFP”) issued by NHIT Southern Projects Private Limited (NSPPL) for Engagement of Agency/Firm for electrical improvement works of Highway Street Lights & Toll Plaza on four-lane of Bareilly – Sitapur Road Section NH-30 (Old NH-24) with a total length of 157.590 Km in the State of Uttar Pradesh.
NSPPL/FY26-27/RFP/Bareilly Sitapur/Highways Street-Light
NSPPL/FY26-27/RFP/Bareilly Sitapur/Highways Street-Light
RFP
Uttar Pradesh
14 Aug 2026
31 Jul 2026
14 Aug 2026
Subject:- BOQ for Electrical improvement works for Highway Street Lights & Toll Plaza submitted by Designtech MEP Consultants.
Sr. No Specification UOM PR.Qty. Rate Amount Remark
1 MAIN STREET LIGHT FEEDER PILLAR Complete SITC Set of Main Street Feeder Pillar as below Electrolytic grade Aluminium bus bar by means of SMC / DMC type insulator 110/220 V LED (22.5 mm dia ) R Y B ON Indicating lamp with integral circuit terminal block including connection etc. as required. Electrical insulating rubber matts confirming to IS: 15652 / 2006 with one side anti skid aberration marks and pasting the mat with synthetic rubber adhesive as required. 11 KV 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV Current Transformer with all necessary support in existing panel including connection etc. as required . from 40/5 to 63/5 Ratio 10 VA class 1 accuracy 0.5 A to 4 A rating (Protection MCB) CT operated direct reading type Ampere meter on existing panel making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Below 500 A (Digital type) (0-500) V range Volt meter on existing panel making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type selector switch of 10 A for voltmeter (4 position ) including making connection etc. as required . CT linked selector switch of 10 A for Ampere meter (4 position ) including making connection etc. as required . Totally enclosed Plinth mounted dust vermin proof double door outdoor type IP55 Feeder Pillar made out of min 3mm sheet complete complete including foundation civil and structural works INCOMING P&F 415 V AC FP MCB with positive isolation of breaking capacity not less than 10/16 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs testing etc. as required. 63 Amp 10 kA - 1 nos. OUTGOINGS P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs testing etc. as required. Double pole MCB 32 A rating ( 2 no.) Four pole MCB 6 A to 25 A rating ( 8 no.) 1no. 110 - 240 V AC 1 ph. 2 W Astronomical time switch with surge suppressor memory card Sunrise / Sunset selectable software for programming including making connection etc. as required Provide Space for energy meter in panel compartment ( Energy meter will be supplied & Installed by DISCOM ) P & F of ac operated heavy duty 230 /415 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking auxilary contacts Din rail mounting type including making connections testing etc. as required. 4 pole Power Contactors with following AC 1 Rating 40-63 Amp. Nos 35 In Place of Rusted, Damaged or Missing Panel, Location wise sheet is attached for referece
2 MCB 6A-32A 2 Pole Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 6 to 32 Amp Nos 100 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution.
3 MCB 32A 4 Pole Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity Nos 10 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution.
4 MCB 40A 4 Pole Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity Nos 10 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution.
5 MCB 63A 4 Pole Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having given capacity Nos 60 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution.
6 MCB 6A-25A 1 Pole providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Nos 1000 Major requirement of 1 Pole MCB required for all existing 699 No's LED light fixture (263.000, 290.600, 306.100, 314.640, 348.600, 370.700, 382.750, 403.400, 403.650, 413.850, 416.750) othar all location (Ch:-270-419) where HPSV Light fixture available in Place of Damaged/Missing MCB
7 Contactor 4 pole 440V 63 Amp Make L&T Supplying & erecting power contactor AC3 duty for time switch complete erected as per direction Cat III Nos 60 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution.
8 16 Sq.mm ( 4 core) XLPE Aluminium Armoured Cable Make Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade, for TMS, & Street Light at Site & Toll Plaza. Rmt 25000 The existing overhead cable installed along the roadside for street lighting is required to be replaced with a suitably rated underground cable. The current underground/overhead unarmoured cable laid at the crash barrier is of low quality and has inadequate load-carrying capacity, resulting in repeated major faults, overheating, and short-circuiting of the pole-to-pole cable. Replacing it with a properly rated underground cable will improve system reliability, prevent recurring failures, and ensure safe and efficient operation of the street lighting network.
9 25 Sq.mm (4 core) XLPE Aluminium Armoured Cable Make- Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade for highway Street Light at Site & Toll Plaza cable renovation. Rmt 20000 Cable is required at the toll plaza for renovation works and for the replacement of damaged cables used for street lights and high-mast lighting. The replacement cable shall be selected as per the connected electrical load and prevailing site conditions to ensure safe, reliable, and efficient operation of the lighting system. Backup sheet is attached for reference
10 35 Sq.mm (4 core) XLPE Aluminium Armoured Cable Make- Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade for highway Street Light at Site & Toll Plaza cable renovation. Rmt 2000 Cable is required at the toll plaza for renovation works and for the replacement of damaged service cables from the transformer to the energy meter and from the energy meter to the feeder pillar, serving the street lighting and high-mast lighting systems.
11 50 Sq.mm (3.5 core) XLPE Aluminium Armoured Cable Make- Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade for highway Street Light at Site & Toll Plaza cable renovation. Rmt 1000 Cable is required at the toll plaza for renovation works and for the replacement of damaged service cables from the transformer to the energy meter and from the energy meter to the feeder pillar, serving the street lighting and high-mast lighting systems.
12 70 Sq.mm (3.5 core) XLPE Aluminium Armoured Cable Make- Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade, for highway Street Light at Site & Toll Plaza cable renovation. Rmt 1000 Cable is required at the toll plaza for renovation works and for the replacement of damaged service cables from the transformer to the energy meter and from the energy meter to the feeder pillar, serving the street lighting and high-mast lighting systems.
13 DWC HDPE PIPE 63 mm dia (OD-63 mm & ID-51 mm nominal) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket bend couplers etc. conforming to IS 14930 Part II complete with fitting and cutting jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench including sand cushioning complete as required or Directly install on behind the Crash barrier of VUP / PUP / Flyover / ROB / etc. with complete accossories SS saddles nuts bolts complete as required for Cable laying pipe from pole to pole. Replace as when required, for ATMS & highway Street Light at Site & Toll Plaza cable for cable renovation. Rmt 10000 DWC HDPE pipe is required at the toll plaza for renovation works, for Laying of ATMS supply at site and for the replacement of damaged undergrund cables from Pole to Pole. Location wise sheet is attached for referece
14 DWC HDPE PIPE 100 mm Dia (OD-100 mm & ID-90 mm nominal) Supplying and laying of following size HDPE pipe ISI marked along with all accessories like socket bend couplers etc. conforming to IS 14930 Part II complete with fitting and cutting jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench including sand cushioning complete as required or Directly install on behind the Crash barrier of VUP / PUP / Flyover / ROB / etc. with complete accossories SS saddles nuts bolts complete as required Replace as when required, Rmt 1500 Laying of DWC HDPE pipe is required at the toll plaza for renovation works it will be laying throgh the chamaber to chamber., Location wise sheet is attached for referece
15 HDD Work With 100 mm Dia PN6-8 grade HDPE Pipe Providing and laying / Insert HDPE pipe for HT / LT underground cable including laying jointing insertation of hdpe pipe 2 nos x 100mm dia and 6 mm thickness without damaging surface / Road by using horizontal auger guided boring / Horizontal directional drilling machine by push and loop method. Insert of hdpe pipe in side Road boundary by cut and fill method. Rate are included with Providing and supply of hdpe pipe - 2 nos x 100mm dia. RMT 1500 Laying of DWC HDPE pipe is required at the toll plaza for renovation works it will be laying . Location wise sheet is attached for referece
16 HDD Work With 100 mm or 63 mm Dia PN6-8 grade HDPE Pipe Providing and laying / Insert HDPE pipe for HT / LT underground cable including laying jointing insertation of hdpe pipe 1 Nos x 100 mm dia or 1 nos x 63mm dia and 6 mm thickness without damaging surface / Road by using horizontal auger guided boring / Horizontal diractional drilling machine by push and loop method.Insert of hdpe pipe in side Road boundary by cut and fill method. Rate are included with Providing and supply of hdpe pipe - 1 nos x 63mm dia. RMT 1000 Laying of DWC HDPE pipe is required at the toll plaza for renovation works it will be laying . Location wise sheet is attached for referece
17 Birck Wall Electrical Chamber with Cover Constructing brick masonry manhole / Chamber in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 1200x900 mm and 900 mm deep including C.I. cover with frame (medium duty) 500 mm internal diameter total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : Nos 32 at the toll plaza for cable renovation works , the cable will be laying throgh the chamaber to chamber., Location wise sheet is attached for referece
18 GI Chemical Earthing Providing Fixing & Testing of Maintenance free Gel Earthing with Pipe in Strip Technology filled with anti-corrosive conductive compound (CPRI Tested) below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineral filling compound (MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone) and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes. With Pipe in Strip Technology (Inner pipe dia. / Outer pipe dia. ) 80 - 100-micron GI Coating.GI Pipe 2000 mm Long 50 / 25mm Terminal 12 mm GI Strip. For highway street Light High mast Pole & Panel earthing as per site requirement Nos 400 For Street Light pole & Panel, highmast Pole & Panel body earthing at site
19 Copper Chemical electrode 50X3000 MM Earthing Work for Neutral & Body earthing of essential Electrical Equipment (Transformer VCB Cubical energy Meter DG & etc at Toll Plaza. SITC of Maintenance Free Copper Chemical electrode (99.9 % Pure) as per standard IS 3043:1987 inclusive of Manpower Material Machinery with the following specifications: (a) Copper Chemical electrode 50X3000 MM. (b) GI Mess Pipe 40X2000 mm (c) Copper Strip: 25X3 MM from earthing electrode to nearest Electrical Equipment. (d) Bentonite Powder /Charcole & Salt mixture 25 kg for every earthing pit/ As needed. (e) Heavy Duty Earthing Chamber (HDPE Square Type) Earthing Chamber having dimensions 300mmX300X260mm with concereting of Chamber for every earth Pit. (f) The Value of each earthing should be less than 3 Ohm. It will be the responsibility of contactor/ agency to pour appropriate quantity of water in all the earthing during the work of each earthing. Nos 16 Provision for body earthing and neutral earthing shall be made for essential electrical equipment. The location-wise earthing details sheet is enclosed herewith for reference.
20 GI Chemical electrode 50X3000 MM Earthing work for Body earthing of Electrical Equipment at Toll Plaza SITC of Maintenance Free GI Chemical electrode as per standard IS 3043:1987 inclusive of Manpower Material Machinery with the following specifications: (a) GI Chemical electrode 50X3000 MM. (b) GI Mess Pipe 40X2000 mm. (c) GI Strip: 25X3 mm from earthing electrode to nearest Electrical Equipment. (d) Bentonite Powder /Charcoal & Salt mixture 25 kg for every earthing pit / As needed. (e) Heavy Duty Earthing Chamber (HDPE Square Type) Earthing Chamber having dimensions 300mmX300X260mm with concreting of Chamber for every earth Pit. (f) The Value of each earthing should be less than 3 Ohm. (g) It will be the responsibility of contactor/ agency to pour appropriate quantity of water in all the earthing during the work of each earthing. Nos 56 For electrical equipment body earthing Location wise sheet is attached for referece
21 Vertical Air Termination / Lightning Arrester for electrical Building SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning; Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST 34mm dia Cold Galvanized. complete with all mounting post clamps nuts bolts insulators etc. Nos 2 For Both Toll Electrical Building
22 GI Earthing Strips Supply & Laying Hot Deep required size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting soldering saddles making connection etc. as required. NOS 1800 For electrical equipment body earthing Location wise sheet is attached for referece
23 Copper Earthing Strips Supply & Laying required size Copper strip in horizontal or vertical run in ground/surface/recess including riveting soldering saddles making connection etc. as required. NOS 150 Provision for body earthing and neutral earthing shall be made for essential electrical equipment. The location-wise earthing details sheet is enclosed herewith for reference.
24 Copper Flexi cable 70 sq. mm Supply & fixing of 70 sq.mm PVC insulated Copper flexible cable as down conductor complete install with saddles/clamps. Rmt 150 For Both Toll Plaza LA earthing for Electrical Building
25 Lightning Strike Counter SITC of Lighting counter - To count no of lightning strike & it can record the date and time of the lightning having plastic encloser IP-65. Measuring Range: 0-100 KA Display: LCD-with 0-999 count operating temprature: -20 to 60 degree celcius No odsensor:1 nos (JEF CAPE DEHN OBO Better Man make) Nos 2 For Both Toll Plaza LA earthing for Electrical Building
26 10 Mtr. GI Octagonal Street Light Pole Supply installation testing & commissioning of 10 mtr Supply and installation (Excluding foundation work) of 10 m ( clear pole height is 10 mtr. from road surface On main carriage Way. Long 70 mm Top X 175mm bottom dia 3 mm thickness Octagonal poles. Made from CR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/4759. with required base plate suitable suspend local wind speed ( 140 km/Hr) and pole base is heavy MS plate welded with pole bottom with M 24 x 750 long ’J’ type EN 8 grade foundation bolts along with template for the above poles.with Rate includes (a) Supply & erection of Bakelite sheet with 2 no. 6A SP MCB & External surge protector - 20 kV & stud type terminal block suitable upto 4Cx35 sq. mm Cable. (b) Supply & Installation of 3Cx1.5 sq. Cu Flexible FRLS Wire for connection of light fitting.( From Pole JB to light fixtures ) (C) Spiral Earthing ( If ground Available ) for each streetlight pole complete with 8 SWG galvanized wire having 5 feet deep in ground and 1 feet spiral portion covered by salt coal etc. or Connect earthing through cable steel / wire armoured only. (D) For Earthing if ground is not available In that case Pole earthing on flyover / ROB / VUP / PUP etc will be by laying 8 SWG GALVANISED wire along with pole to pole cables from feeder pillars. Nos 100 For Damaged street Light pole repacement , details sheet is enclosed herewith for reference.
27 Copper Flexi Cable 3X1.5 Sq. mm Supply & Installation of 3Cx1.5 sq. Cu Flexible FRLS Wire for connection of light fitting. ( From Pole Junction Box to light fixtures) Rmt 12000 ( From Pole Junction Box to light fixtures), details sheet is enclosed herewith for reference.
28 Single Arm 1.0 Mtr 10 Degree Supply Installation Testing & Commissioning of 1.0 mtr. long & 10-degree Tilt angle Hot dip galvanised Single Arm bracket made up of 40NB dia GI pipe suitable to mount on TOP of pole having top 70mm A/F or as per existing pole top pipe diameter. Nos 20 For Damaged street Light pole repacement , details sheet is enclosed herewith for reference.
29 Double Arm 2 Mtr. 16 Degree Supply Installation Testing & Commissioning of 2 mtr long & 16-degree Tilt angle hot dip galvanised Single Arm bracket made up of 40NB Dia GI pipe suitable to mount on Side of pole on Service Roadside (Differential Arm pole) Nos 30 For Damaged street Light pole repacement , details sheet is enclosed herewith for reference.
30 Double Arm 2.5 mtr 10 Degree Supply Installation Testing & Commissioning of 2.5 mtr. Long & 10 degree Tilt Angle hot dip galvanised Double Arm bracket made up of 40NB dia GI pipe suitable to mount on TOP of pole having top 70mm A/F or as per existing pole top pipe diameter. Nos 50 For Damaged street Light pole repacement , details sheet is enclosed herewith for reference.
31 RCC Foundation (M20) for 10 Mtr Octagonal Pole RCC Foundation (M20) for 10 Mtr Octagonal Pole Providing of RCC Foundation (M20) Foundation Size: 600mm x 600mm x 1200 mm. with bolts 4 nos of octagonal pole including excavation of pole pit. The scope shall also include grouting of foundation bolts including watering and ramming & provision for passage of cable by using suitable size GI pipe / DWC pipe / HDPE pipe. Vendor submit the civil foundation details from structure consultants for approval from IE / Client Note:- If the any existing foundation is found suitable for installation of the new pole the same will be used after approval and construction of new foundation will not be required. Nos 100 For Damaged street Light pole repacement , details sheet is enclosed herewith for reference.
32 L Bracket with Fastener/ Bolt for 10 mtr Octagonal Street Light Pole SITC of MS wall mounted steel bracket on RE wall to rest streetlight octagonal pole incl. Hilti make fastener. Contractor shall have to submit structural design for the same. Vendor submit the MS Foundation bracket details from structure consultants for approval from IE / Client Nos 20 Some poles at Km 295 and Km 403 are hanging due to improper fixing and require re-fixing to ensure proper alignment and structural stability.
33 200W LED STREET LIGHT FOR MAIN CARRIAGEWAY LIGHTING + SERVICE ROAD LIGHTING SITC of 200W SMD LED Streetlight fixture with System efficacy of 135 lm/W (27000 lumens). Luminaire shall be made up of pure polyester powder coated die cast Aluminium housing with IP rated high purity Polycarbonate lens . The luminaire should have a dimension of 417mm x 285mm x 2mm ± 2mm appoximate weight of 3.8 Kg ± 0.25 Kg. The housing should be made of LM6/ADC12 Alloy non-corrosive Single Piece pressure die-cast aluminum to withstand extreme environments. All external hardware must be of SS304 grade. Luminaire shall be designed with street optic LENS for uniform light distribution. Maximum LENS dome top temperature shall be less than 95°C at 45°C ambient temperature. LM 80-08 compliant LEDs of EMC/ceramic package of wattage of 4W-5W from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 and IK10 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K CRI of Minimum 70 and SDCM of < 5. LEDs must be driven at max 70% of the rated current. MCPCB with Aluminium core and copper thickeness of 35 micron to be used for LED mounting. LED Driver shall be silicone potted Integrated type Isolated Constant Current with range 140-280V AC. Driver Efficiency > 88% & 4 KV internal surge protection with additional 10KV SPD mounted inside the luminaire and firmly fixed to the housing Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED Driver must have short circuit open circuit Auto cut-off protection for low and high input voltage. Driver must have 440V input voltage protection for 8 hours. LED driver should have over temperature protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 3:2013; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Make-Wipro/Philips/Bajaj/Crompton/Havells Safely removing and shifting old fixtures, and depositing them in writing at the toll plaza or store, etc. Nos 2550 Required Total installation of 200 W LED Light fixture in place of 400W HPSV , details sheet is enclosed herewith for reference.
34 Wallmounted 80 W LED Flood Street Light FOR UNDERNEATH VUP LIGHTING SITC of 80 W LED High bay light having min system lumen output of 10500. Min system Efficacy should be > 130 Lm/w. Housing Should be made up of Al die cast having High Transmittance Polycarbonate cover. Luminaire should be IP66 and IK08 Protected. Luminaire should have proper Heat sink for thermal management with eye bolt mounting. Luminaire should have beam angle of 110 Deg Wide beams for proper light distribution CRI > 80 SDCM < 5 with lifeclass of 50000 Hrs @L70B50.. Driver use should be of potted and encapsulated only. Operating voltage range of driver should be of 140 – 270 VAC with 4 KV internal surge protection THD < 10% PF > 0.95 High voltage cut off & Auto restart @ 320 VAC Phase to phase 440 V Protection for 8 Hrs. Driver should be of reputed makes such as Philips Xitanium / Osram / Meanwell only. Driver & luminaire both should be BIS Approved only. Luminaire should be tested under NABL Accredited Lab for LM79/LM80/TTC. Similar to Philips BY225P LED100S CW WB PSU FG GR Nos 210 Location for underpass lighting details sheet is enclosed herewith for reference.
35 Highmast Repairing Supply & Laying of raising lowering system comprising double drum winch 6 / 8 mm diameter SS wire rope trailing cable connector integral power tool motor manual handle junction box lightening finial. Nos 30 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
36 Aviation lamp for High mast SITC of LED type double dome aviation obstruction light for 30 Mtr Highmast. Nos 30 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
37 Re-installation of High mast pole when required Erection of the high mast with the help of suitable tools and plants wiring of luminaries with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm lugs MCB and all labour as a complete job. Rate include cranes for using lowering & re-installation of High mast pole. Nos 10 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
38 HIGH MAST FEEDER PANEL 30 Mtr Highmast SITC of outdoor stand mounted feeder pillar with 40A TPN MCB incomer single dial time switch 40A FP contactor for the automatic switching of luminaries power tool control with 2 no 9A contactors and raise lower push button Incoming 35 sq. mm and out going 20 x1.5 sq. mm terminals. (4) Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour. (Foundation civil design will be approved by structural consultants). Nos 35 Location for installation of Highmast Control Panel details sheet is enclosed herewith for reference.
39 400 WATT LED LIGHTING FIXTURES FOR HIGH MAST @ ALL JUNCTIONS + GRADE SEPARATED JUNCTIONS ETC. SITC of 400W SMD LED Floodlight fixture with System efficacy of 125 lm/W (50000 lumens). Luminaire shall be made up of LM6/ADC12 Alloy non-corrosive pure polyster power coated die cast Aluminium housing with PC lens. Lumianire should be of dimension 319mm x 507mm x 97mm height ± 5mm height and the approximate weight should be within the 12.0Kg ± 0.5Kg. Luminaire should be available with 25° and 60° beam angle option. Luminaire should be made of four individual modules of 100W to 125W each. All external hardware must be of SS304 grade. LM 80-08 compliant LEDs of EMC/ceramic package of wattage of 5W from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Maximum LENS dome top temperature shall be less than 95°C at 45°C ambient temperature. Luminaire shall be with IP66 and IK07 protection. It should be cabable to operating under ambient temperature range of -10°C to +45°C. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K CRI of Minimum 70 and SDCM < 5. LEDs must be driven at max 70% of the rated current. MCPCB with Aluminium core and copper thickeness of 35 micron to be used for LED mounting. LED Driver shall be silicone potted Integrated type Isolated Constant Current with range 140-280V AC. Driver Efficiency > 88% & 4 KV internal surge protection with additional 10KV SPD mounted inside the luminaire and firmly fixed to the housing Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED Driver must have short circuit open circuit Auto cut-off protection for low and high input voltage. LED driver should have 440V AC protection for atleast 8 hours.LED driver should have over temperature protection.Individual drivers should be provided with individual modules along with ventilated enclousure to hide the wirings. Driver must be with Aluminium casing. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Nos 510 Location for installation/replacement of Highmast LED Light fixture in Place of HPSV Fixture, details sheet is enclosed herewith for reference.
40 Internal Electrical Wiring (Lighting Circuit) for Toll Plaza :- Providing and erecting Point wiring with 1.1 KV grade ISI marked 2 X 1.5 sq. mm copper PVC insulted FRLS wire with 1.5 sq. mm (green) copper PVC insulated FRLS wire for earth continuity in FIA approved ISI mark medium class white colour 20/25 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution erected on/in Brick Wall / slab along with continuous G.I. fish wire to draw wires and laid in approved manner zari for PVC pipe and boxes shall be filled with cement mortar and finishing the surface to match the wall / ceiling complete with approved make 5/6 Amp. ISI make modular type switch and accessories mounted in 20 G. G.I. company fabricated metallic box covered with appropriate front plate modules erected flushed with wall / ceiling with necessary modular lamp holder / modular ceiling rose / HD Connector (make & model approved by EIC and matching colur with switches accessories) (Deep Junction box 75mm depth if required) as directed for concealed wiring. Light point. Necessary sheet / tape / polythene / sand must be erected or filled in all box to prevent mortar going into the box. Length of point wiring must not increase than 10 mtr. For that necessary switch boards and their locations must be finalised before execution by agency otherwise payment will not be done for extra long point. (For future extention if required agency has to erect one higher size metal box and modular plate as per instruction of EIC. Cost of blank plate shall be paid as per tender item) [This item include cleaning (inside/outside) of all G.I. switch boards electric point box fan box MCBDB & box cutting plaster finishing for modular plate without any gap] [conductor resistance should be as per IS:8130/1984] NOS 100 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
41 Internal Electrical power Wiring for Toll Plaza :- Providing and fixing Plug Point wiring with 1.1 KV grade ISI marked approved make 2 x 2.5 sq.mm copper PVC insulated FRLS wire with 1.5 sq.mm (green) copper PVC insulated FRLS wire for earth continuity in FIA approved ISI mark white colour medium class 20/25 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution erected in wall/slab along with continuous G. I. fish wire to draw wires and laid in approved manner zari for PVC pipe & boxes shall be filled with cement mortar & finishing the surface to match the wall / ceiling complete with 16 Amp Modular type Swich and accessories mounted in 20 G. GI company fabricated metallic box covered with appropriate front plate modules erected flushed with wall. (a) 16 Amp. Indicator switch & 1 No. 6/16 A universal socket white colour suitable for 3/5 pin top duly both having ISI mark. (Necessary sheet / tape / polythene / sand must be erected or filled in all box To Prevent Mortor Going In To The Box) (Conductor resistance should be as per IS:8130/1984) ( FOR POWER PLUG IN BOOTH & ADMIN BUILDING ) NOS 40 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
42 Power Wiring for (A.C POINT / BLOWER ONLY FOR BOOTH & ADMIN BUILDING) Providing & Erecting Plug Point wiring with approved ISI marked 1.1 kv grade 2 x 4.0 sq.mm copper PVC insulated FRLS wire with 2.5 sq.mm (green) copper PVC insulated FRLS wire for earth continuity in FIA approved ISI mark white colour medium class 25 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution erected in wall / slab along with continuous G.I. fish wire to draw wires and laid in approved manner. zari for PVC pipe & boxes shall be filled with cement mortar & finishing the surface to match the wall / ceiling complete with approved make 20 Amp. Modular type indicator switch and accessories mounted in 20 SWG GI company fabricated metallic box covered with appropriate front plate modules erected flushed with wall / ceiling. (a) 20 Amp Indicator switch & 1 No. 20 A universal socket white colour suitable for 3 pin top duly both having ISI mark(A.C POINT / BLOWER ONLY FOR BOOTH & ADMIN BUILDING ) (Necessary sheet / tape / polythene / sand must be erected or filled in all box to Prevent Mortor Going In to The Box) the quantity will be consider in set/point. NOS 60 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
43 Surge Protection Device (SPD) Supply Installation Testing & Commissioning of Three Phase 440 V Surge Suppressor protection Device (SPD) & 40 Amp TPN MCB (or As per SPD OEM guide line for the protection of SPD which is erected such a way that it can be operated easily) SPD must be capable to protect all electrical and electronics equipments if SPD blast or fuse then the panel builder must have replace it soon during defect liability period. (Hakel ikra OBBO make) (With Three year Gaurantee/warranty) Nos 6 For Electrical equipment safety, It will be installed in 1 No's in Admin building & 2 No's in SWB Building at both toll plaza
44 6-Way SPN DB Board Double Door SITC of Approved make 6-Way SPN Double Door metal clad D.B. company prewired having Incoming and outgoing as mentioned below with NL suitable to operate on 230 Volt A.C. power and having overload and short circuit tripping element breaking capacity 10KA (for all MCB & ELCB) to be erected in flush type and company fabricated 16 G.M.S./ IK 08 Certificate sheet box with powder coated inside and outside after apply seven tank chemical process of M.S. sheet cover complete with suitable integral single piece construction tinned copper busbar- and link with all necessary interconnection and with neccessary size wooden board for mounting MCBDB . Manufacturer must be Provided .(1)IP 43 Protection Certificate.(2) Seven tank Powder Coating Certificate.(3) Copper/Brass make Neutral & Earthing link with Isolation and Protecting Cover. (a) For 6 Way SPN MCBDB with I/c:- 25 Amp DP RCBO(RCCB+MCB) 10KA & O/G :- C-curve 6-16 Amp SP MCB :- 4 Nos. For Toll booth UPS power & For Electrical Room + Medical Aid post Nos 36 Panel/Switc borad/ MCB Board are required at the both toll plaza for cable renovation & Proper Load separation work.
45 8-Way TPN DB Board SITC of Approved make 8-Way TPN DB - Three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) Double Door metal clad D.B. company prewired having Incoming and outgoing as mentioned below with NL suitable to operate on 415 Volt A.C. power and having overload and short circuit tripping element breaking capacity 10KA (for all MCB & ELCB) to be erected in flush type and company fabricated 16 G.M.S./ IK 08 Certificate sheet box with powder coated inside and outside after apply seven tank chemical process of M.S. sheet cover complete with suitable integral single piece construction tinned copper busbar- and link with all necessary interconnection and with neccessary size wooden board for mounting MCBDB . Manufacturer must be Provided .(1)IP 43 Protection Certificate.(2) Seven tank Powder Coating Certificate.(3) Copper/Brass make Neutral & Earthing link with Isolation and Protecting Cover. (a) For 8 Way TPN MCBDB I/c:- 63 Amp FP MCB 10KA C-63 A DP ELCB 30ma 10KA -03 nos O/G :- C-curve 6-32 Amp SP MCB :- 21 Nos. For Toll plaza - Admin building GF + FF - Lighting & Raw power DB & Toll lane TMS equipment Nos 6 Panel/Switc borad/ MCB Board are required at the both toll plaza for cable renovation & Proper Load separation work.
46 PVC PIPES 25 MM Dia Providing and erecting Medium Class FIA approved and ISI mark white colour (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & clamps on / in wall / ceiling along with continuous fish wire to draw mains with necessary fittings and junction boxes for following dia. (a) 25 mm. dia. Rmt 1000 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
47 2 Type x 1.5 sq.mm. Single core FRLS copper PVC Insulated wire Providing and laying Mains with FRLS PVC Insulated wire ISI marked 1.1 KV grade with FIA approved ISI mark medium class 20/25/32 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution to be erected on/in brick wall / slab along with continuous G. I. fish wire to draw mains laid in approved manner with plastering by cement mortar & finishing the surface to match the wall / ceiling complete with FRLS PVC insulated wire for earth continuity. (Approved ISI make only) [a] 2 x 1.5 sq.mm. FRLS copper multi stranded conductor mains with 1.5 sq.mm. FRLS copper multi stranded conductor for earthing as per standard colour code. [conductor resistance should be as per IS:8130/1984] for Toll plaza Main Wiring Rmt 500 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
48 2 type x 2.5 sq.mm. Single core FRLS copper flexi wire multi stranded conductor mains with 1.5 sq.mm. FRLS copper multi stranded conductor Providing and laying Mains with FRLS PVC Insulated wire ISI marked 1.1 KV grade with FIA approved ISI mark medium class 20/25/32 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution to be erected on/in brick wall / slab along with continuous G. I. fish wire to draw mains laid in approved manner with plastering by cement mortar & finishing the surface to match the wall / ceiling complete with FRLS PVC insulated wire for earth continuity. (Approved ISI make only) [b] 2 x 2.5 sq.mm. FRLS copper multi stranded conductor mains with 1.5 sq.mm. FRLS copper multi stranded conductor for earthing as per standard colour code. (Conductor resistance should be as per IS:8130/1984) Rmt 1500 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
49 2 Type x 4.0 sq.mm. FRLS copper multi stranded conductor mains with 2.5 sq.mm. FRLS copper multi stranded conductor for earthing Providing and laying Mains with FRLS PVC Insulated wire ISI marked 1.1 KV grade with FIA approved ISI mark medium class 20/25/32 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution to be erected on/in brick wall / slab along with continuous G. I. fish wire to draw mains laid in approved manner with plastering by cement mortar & finishing the surface to match the wall / ceiling complete with FRLS PVC insulated wire for earth continuity. (Approved ISI make only) [c] 2 Type x 4.0 sq.mm. FRLS copper multi stranded conductor mains with 2.5 sq.mm. FRLS copper multi stranded conductor for earthing as per standard colour code. [conductor resistance should be as per IS:8130/1984] Rmt 1500 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
50 LED Tube Light 20-24 W 4 feet SITC Of Max 24 Watt LED Indoor Commercial make high efficiency performance Tube rod Approx. 4 feet (lamp) with combination of high quality diffused polycarbonate and alluminium base dedicated heat sink for better perfomance of LED and also long life.High quality LED must be placed on metal core printed circuit board for better heat dissipation. seprate driver with all protection like under voltage (160V to 270V) over voltage protection 2 KV surge protection.The life of lamp should have 25 000 hrs at L70 THD<15% efficiency >=110lm/w with high power factor > 0.90 with CRI > 80 for better color rendition total lumens should be min 2400. The lamp should be suitable for T8 box type fitting made form CRCA sheet and white powder coated.The data sheet of LM79 for complete lamp can also be provided (Note:-The manufacturer/ authorised Channel partner of the manufacturer has to submit 4 yr free replcement Guarantee for complete Fixture ) (Approval will be given strictly subject to item specification). Nos 50 For installation Tunel with proper wiring at both toll Plaza
51 Cable Tray 300X40X4 mm Supplying and erecting approved make GRP Perforated type Cable Tray with required GRP Straight Coupler Plates Corner etc. Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System Glass Content : 55 – 60 % - - Standard Length : 3000mm- Support Span – 1500mm Deflection L/200 - Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94 Very Low Flammability - Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65. (E) Width - 300 mm Pultruded “C” Channel with 40mm Sides 4mm Thickness Loading 25 Kg./Mtr. ( Sumip coromandak Eircon Satyam -composite Make or equivalent make app by engineer in charge subject to above specification) Rmt 100 For installation Tunel & near the admin building for proper cabling/dressing at both toll Plaza
52 8 SWG GI Earthing Wire upply & Laying Hot Deep 8 swg GI earth wire in horizontal or vertical run in ground/surface/recess including riveting soldering saddles making connection etc. as required. from Street Light Pole to pole connection & laying with Existing Armoured cable Rmt 32000 For all existing Pole earthing , Panel, & highmat earthing
53 200A 415 Volts TPN Rewireable Cut-Out fuse units with mounting Bracket Supplying, Installing, Testing & Commissioning (SITC) of TPN Rewireable Switch Fuse Unit, rated 200 Ampere, 415 Volt AC, 50 Hz, 3-Phase, 3-Pole, complete with MS mounting bracket and accessories, suitable for outdoor highway street lighting application. The unit shall be installed after the energy meter and before the street light feeder pillar panel, complete in all respects as per specifications and site requirements.Quick make and break operation Enclosure made of CRCA sheet steel, duly pre-treated and powder coated, Hard bright tin-plated copper contacts for Terminals suitable for Aluminium and Copper conductors, Porcelain fuse carriers with fully shrouded live parts, Door interlocking facility provided for safety, Knock-outs provided at top, bottom and rear sides for cable entry Separate fuse and terminal block arrangement, Adequate internal space for wiring and maintenance PVC gasket provided for weather-proof sealing, MS mounting bracket complete with clamps, nuts and bolts Nos 10 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution. It will be installed after energy meter & before load or Fedeer pillar Panel
Sub:- BOQ for Electrical improvement works for Highway Street Lights & Toll Plaza submitted by Designtech MEP Consultants.
Sr. No Specification UOM PR.Qty. Rate Value Remark
1 MAIN STREET LIGHT FEEDER PILLAR Complete SITC Set of Main Street Feeder Pillar as below Electrolytic grade Aluminium bus bar by means of SMC / DMC type insulator 110/220 V LED (22.5 mm dia ) R Y B ON Indicating lamp with integral circuit terminal block including connection etc. as required. Electrical insulating rubber matts confirming to IS: 15652 / 2006 with one side anti skid aberration marks and pasting the mat with synthetic rubber adhesive as required. 11 KV 2.5 mm thick with proof voltage 22 KV / 3 min. and Break Down Voltage 45 KV Current Transformer with all necessary support in existing panel including connection etc. as required . from 40/5 to 63/5 Ratio 10 VA class 1 accuracy 0.5 A to 4 A rating (Protection MCB) CT operated direct reading type Ampere meter on existing panel making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Below 500 A (Digital type) (0-500) V range Volt meter on existing panel making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type selector switch of 10 A for voltmeter (4 position ) including making connection etc. as required . CT linked selector switch of 10 A for Ampere meter (4 position ) including making connection etc. as required . Totally enclosed Plinth mounted dust vermin proof double door outdoor type IP55 Feeder Pillar made out of min 3mm sheet complete complete including foundation civil and structural works INCOMING P&F 415 V AC FP MCB with positive isolation of breaking capacity not less than 10/16 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs testing etc. as required. 63 Amp 10 kA - 1 nos. OUTGOINGS P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs testing etc. as required. Double pole MCB 32 A rating ( 2 no.) Four pole MCB 6 A to 25 A rating ( 8 no.) 1no. 110 - 240 V AC 1 ph. 2 W Astronomical time switch with surge suppressor memory card Sunrise / Sunset selectable software for programming including making connection etc. as required Provide Space for energy meter in panel compartment ( Energy meter will be supplied & Installed by DISCOM ) P & F of ac operated heavy duty 230 /415 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking auxilary contacts Din rail mounting type including making connections testing etc. as required. 4 pole Power Contactors with following AC 1 Rating 40-63 Amp. Nos 35 85,000.00 2,975,000.00 In Place of Rusted, Damaged or Missing Panel, Location wise sheet is attached for referece This needs to be considered
2 Digital time switch Make L&T Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme suitable to operate on 240V + 5% 16A with floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed. Nos 5,500.00 0.00 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution. This can be left out for now; if the need arises in the future, it can be ordered and installed individually. Removed from PR
3 MCCB 100 A 4 Pole 440 V Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections spreader tinned copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only Nos 7,500.00 0.00 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution. This can be left out for now; if the need arises in the future, it can be ordered and installed individually. Removed from PR
4 MCB 6A-32A 2 Pole Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 6 to 32 Amp Nos 100 325.00 32,500.00 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution. Such MCBs can be used in the main feeder pillars of existing streetlights for switching the ATMS supply.
5 MCB 40 A 2 Pole Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity Nos 450.00 0.00 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution. Removed from PR
6 MCB 32A 4 Pole Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity Nos 10 625.00 6,250.00 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution.
7 MCB 40A 4 Pole Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity Nos 10 735.00 7,350.00 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution.
8 MCB 63A 4 Pole Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having given capacity Nos 60 1,150.00 69,000.00 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution. Such MCBs can be installed inside the high-mast poles during repair work; currently, the cables inside the high-mast poles at all locations are directly jointed.
9 MCB 6A-25A 1 Pole providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Nos 1000 150.00 150,000.00 Major requirement of 1 Pole MCB required for all existing 699 No's LED light fixture (263.000, 290.600, 306.100, 314.640, 348.600, 370.700, 382.750, 403.400, 403.650, 413.850, 416.750) othar all location (Ch:-270-419) where HPSV Light fixture available in Place of Damaged/Missing MCB For only the LED street lights quantity to be considered 1000 Qty reduced
10 Contactor 4 pole 440V 16 Amp. Make L&T Supplying & erecting power contactor AC3 duty for time switch complete erected as per direction Cat III No 1,050.00 0.00 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution. To be eliminated from BOQ Removed from PR
11 Contactor 4 pole 440V 63 Amp Make L&T Supplying & erecting power contactor AC3 duty for time switch complete erected as per direction Cat III Nos 60 3,250.00 195,000.00 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution.
12 10.0 Sq.mm ( 4 core) XLPE Aluminium Armoured Cable Make Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade for TMS, ATMs & Street Light at Site & Toll Plaza. Rmt 195.00 0.00 It will be used for ATMS supply at site & both Toll Plaza for cable renovation in Tunnel , Location wise sheet is attached for referece To be directed by the ATMS Team Remove from PR, instructed by QS Team
13 16 Sq.mm ( 4 core) XLPE Aluminium Armoured Cable Make Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade, for TMS, & Street Light at Site & Toll Plaza. Rmt 25000 225.00 5,625,000.00 The existing overhead cable installed along the roadside for street lighting is required to be replaced with a suitably rated underground cable. The current underground/overhead unarmoured cable laid at the crash barrier is of low quality and has inadequate load-carrying capacity, resulting in repeated major faults, overheating, and short-circuiting of the pole-to-pole cable. Replacing it with a properly rated underground cable will improve system reliability, prevent recurring failures, and ensure safe and efficient operation of the street lighting network. Spare quantity considered
14 25 Sq.mm (4 core) XLPE Aluminium Armoured Cable Make- Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade for highway Street Light at Site & Toll Plaza cable renovation. Rmt 20000 275.00 5,500,000.00 Cable is required at the toll plaza for renovation works and for the replacement of damaged cables used for street lights and high-mast lighting. The replacement cable shall be selected as per the connected electrical load and prevailing site conditions to ensure safe, reliable, and efficient operation of the lighting system. Backup sheet is attached for reference Spare quantity considered
15 35 Sq.mm (4 core) XLPE Aluminium Armoured Cable Make- Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade for highway Street Light at Site & Toll Plaza cable renovation. Rmt 2000 325.00 650,000.00 Cable is required at the toll plaza for renovation works and for the replacement of damaged service cables from the transformer to the energy meter and from the energy meter to the feeder pillar, serving the street lighting and high-mast lighting systems. Spare quantity considered
16 50 Sq.mm (3.5 core) XLPE Aluminium Armoured Cable Make- Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade for highway Street Light at Site & Toll Plaza cable renovation. Rmt 1000 375.00 375,000.00 Cable is required at the toll plaza for renovation works and for the replacement of damaged service cables from the transformer to the energy meter and from the energy meter to the feeder pillar, serving the street lighting and high-mast lighting systems. Spare quantity considered
17 10 Sq.mm 3 core XLPE Aluminium Armoured Cable Make- Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade, for TMS, ATMs & Street Light power supply at Site & Toll Plaza. Rmt 165.00 0.00 It will be used for ATMS supply at site & both Toll Plaza for cable renovation in Tunnel , Location wise sheet is attached for referece To be directed by the ATMS Team Remove from PR, instructed by Soumya Sir QS/
18 70 Sq.mm (3.5 core) XLPE Aluminium Armoured Cable Make- Polycab KEI RR Cable Proving & Laying XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I in ground or laying HDPE / DWC pipe. Rate also includes Supplying and making one end termination with heavy duty single compression brass gland SIBG type heavy duty aluminium lugs duly crimped with crimping tool PVC tape etc for following size of Armoured PVC sheathed / XLPE aluminium conductor cable of 1100 volt grade, for highway Street Light at Site & Toll Plaza cable renovation. Rmt 1000 450.00 450,000.00 Cable is required at the toll plaza for renovation works and for the replacement of damaged service cables from the transformer to the energy meter and from the energy meter to the feeder pillar, serving the street lighting and high-mast lighting systems. Spare quantity considered
19 DWC HDPE PIPE 63 mm dia (OD-63 mm & ID-51 mm nominal) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket bend couplers etc. conforming to IS 14930 Part II complete with fitting and cutting jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench including sand cushioning complete as required or Directly install on behind the Crash barrier of VUP / PUP / Flyover / ROB / etc. with complete accossories SS saddles nuts bolts complete as required for Cable laying pipe from pole to pole. Replace as when required, for ATMS & highway Street Light at Site & Toll Plaza cable for cable renovation. Rmt 10000 275.00 2,750,000.00 DWC HDPE pipe is required at the toll plaza for renovation works, for Laying of ATMS supply at site and for the replacement of damaged undergrund cables from Pole to Pole. Location wise sheet is attached for referece To be directed by the ATMS Team for HDPE Pipe 10000 Qty Reduced
20 DWC HDPE PIPE 100 mm Dia (OD-100 mm & ID-90 mm nominal) Supplying and laying of following size HDPE pipe ISI marked along with all accessories like socket bend couplers etc. conforming to IS 14930 Part II complete with fitting and cutting jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench including sand cushioning complete as required or Directly install on behind the Crash barrier of VUP / PUP / Flyover / ROB / etc. with complete accossories SS saddles nuts bolts complete as required Replace as when required, Rmt 1500 775.00 1,162,500.00 Laying of DWC HDPE pipe is required at the toll plaza for renovation works it will be laying throgh the chamaber to chamber. Location wise sheet is attached for referece
21 HDD Work With 100 mm Dia PN6-8 grade HDPE Pipe Providing and laying / Insert HDPE pipe for HT / LT underground cable including laying jointing insertation of hdpe pipe 2 nos x 100mm dia and 6 mm thickness without damaging surface / Road by using horizontal auger guided boring / Horizontal directional drilling machine by push and loop method. Insert of hdpe pipe in side Road boundary by cut and fill method. Rate are included with Providing and supply of hdpe pipe - 2 nos x 100mm dia. Rmt 1500 3,250.00 4,875,000.00 Laying of DWC HDPE pipe is required at the toll plaza for renovation works it will be laying . Location wise sheet is attached for referece Quantity to be considered as per layout plan' 500 mtr length reduced from PR UOM Revised
22 HDD Work With 100 mm or 63 mm Dia PN6-8 grade HDPE Pipe Providing and laying / Insert HDPE pipe for HT / LT underground cable including laying jointing insertation of hdpe pipe 1 Nos x 100 mm dia or 1 nos x 63mm dia and 6 mm thickness without damaging surface / Road by using horizontal auger guided boring / Horizontal diractional drilling machine by push and loop method.Insert of hdpe pipe in side Road boundary by cut and fill method. Rate are included with Providing and supply of hdpe pipe - 1 nos x 63mm dia. Rmt 1000 2,500.00 2,500,000.00 Laying of DWC HDPE pipe is required at the toll plaza for renovation works it will be laying . Location wise sheet is attached for referece To be directed by the ATMS Team 500 mtr length reduced from PR UOM Revised
23 Birck Wall Electrical Chamber with Cover Constructing brick masonry manhole / Chamber in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 1200x900 mm and 900 mm deep including C.I. cover with frame (medium duty) 500 mm internal diameter total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : Nos 32 26,000.00 832,000.00 at the toll plaza for cable renovation works , the cable will be laying throgh the chamaber to chamber. Location wise sheet is attached for referece
24 GI Chemical Earthing Providing Fixing & Testing of Maintenance free Gel Earthing with Pipe in Strip Technology filled with anti-corrosive conductive compound (CPRI Tested) below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineral filling compound (MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone) and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes. With Pipe in Strip Technology (Inner pipe dia. / Outer pipe dia. ) 80 - 100-micron GI Coating.GI Pipe 2000 mm Long 50 / 25mm Terminal 12 mm GI Strip. For highway street Light High mast Pole & Panel earthing as per site requirement Nos 400.00 4,500.00 1,800,000.00 For Street Light pole & Panel, highmast Pole & Panel body earthing at site
25 Copper Chemical electrode 50X3000 MM Earthing Work for Neutral & Body earthing of essential Electrical Equipment (Transformer VCB Cubical energy Meter DG & etc at Toll Plaza. SITC of Maintenance Free Copper Chemical electrode (99.9 % Pure) as per standard IS 3043:1987 inclusive of Manpower Material Machinery with the following specifications: (a) Copper Chemical electrode 50X3000 MM. (b) GI Mess Pipe 40X2000 mm (c) Copper Strip: 25X3 MM from earthing electrode to nearest Electrical Equipment. (d) Bentonite Powder /Charcole & Salt mixture 25 kg for every earthing pit/ As needed. (e) Heavy Duty Earthing Chamber (HDPE Square Type) Earthing Chamber having dimensions 300mmX300X260mm with concereting of Chamber for every earth Pit. (f) The Value of each earthing should be less than 3 Ohm. It will be the responsibility of contactor/ agency to pour appropriate quantity of water in all the earthing during the work of each earthing. Nos 16 10,500.00 168,000.00 Provision for body earthing and neutral earthing shall be made for essential electrical equipment. The location-wise earthing details sheet is enclosed herewith for reference.
26 GI Chemical electrode 50X3000 MM Earthing work for Body earthing of Electrical Equipment at Toll Plaza SITC of Maintenance Free GI Chemical electrode as per standard IS 3043:1987 inclusive of Manpower Material Machinery with the following specifications: (a) GI Chemical electrode 50X3000 MM. (b) GI Mess Pipe 40X2000 mm. (c) GI Strip: 25X3 mm from earthing electrode to nearest Electrical Equipment. (d) Bentonite Powder /Charcoal & Salt mixture 25 kg for every earthing pit / As needed. (e) Heavy Duty Earthing Chamber (HDPE Square Type) Earthing Chamber having dimensions 300mmX300X260mm with concreting of Chamber for every earth Pit. (f) The Value of each earthing should be less than 3 Ohm. (g) It will be the responsibility of contactor/ agency to pour appropriate quantity of water in all the earthing during the work of each earthing. Nos 56 6,500.00 364,000.00 For electrical equipment body earthing Location wise sheet is attached for referece
27 Vertical Air Termination / Lightning Arrester for electrical Building SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning; Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST 34mm dia Cold Galvanized. complete with all mounting post clamps nuts bolts insulators etc. Nos 2 9,500.00 19,000.00 For Both Toll Electrical Building
28 GI Earthing Strips Supply & Laying Hot Deep required size GI earth strip in horizontal or vertical run in ground/surface/recess including riveting soldering saddles making connection etc. as required. NOS 1800 110.00 198,000.00 For electrical equipment body earthing Location wise sheet is attached for referece
29 Copper Earthing Strips Supply & Laying required size Copper strip in horizontal or vertical run in ground/surface/recess including riveting soldering saddles making connection etc. as required. NOS 150 1,500.00 225,000.00 Provision for body earthing and neutral earthing shall be made for essential electrical equipment. The location-wise earthing details sheet is enclosed herewith for reference.
30 Copper Flexi cable 70 sq. mm Supply & fixing of 70 sq.mm PVC insulated Copper flexible cable as down conductor complete install with saddles/clamps. Rmt 150 350.00 52,500.00 For Both Toll Plaza LA earthing for Electrical Building
31 Lightning Strike Counter SITC of Lighting counter - To count no of lightning strike & it can record the date and time of the lightning having plastic encloser IP-65. Measuring Range: 0-100 KA Display: LCD-with 0-999 count operating temprature: -20 to 60 degree celcius No odsensor:1 nos (JEF CAPE DEHN OBO Better Man make) Nos 2 3,000.00 6,000.00 For Both Toll Plaza LA earthing for Electrical Building
32 10 Mtr. GI Octagonal Street Light Pole Supply installation testing & commissioning of 10 mtr Supply and installation (Excluding foundation work) of 10 m ( clear pole height is 10 mtr. from road surface On main carriage Way. Long 70 mm Top X 175mm bottom dia 3 mm thickness Octagonal poles. Made from CR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/4759. with required base plate suitable suspend local wind speed ( 140 km/Hr) and pole base is heavy MS plate welded with pole bottom with M 24 x 750 long ’J’ type EN 8 grade foundation bolts along with template for the above poles.with Rate includes (a) Supply & erection of Bakelite sheet with 2 no. 6A SP MCB & External surge protector - 20 kV & stud type terminal block suitable upto 4Cx35 sq. mm Cable. (b) Supply & Installation of 3Cx1.5 sq. Cu Flexible FRLS Wire for connection of light fitting.( From Pole JB to light fixtures ) (C) Spiral Earthing ( If ground Available ) for each streetlight pole complete with 8 SWG galvanized wire having 5 feet deep in ground and 1 feet spiral portion covered by salt coal etc. or Connect earthing through cable steel / wire armoured only. (D) For Earthing if ground is not available In that case Pole earthing on flyover / ROB / VUP / PUP etc will be by laying 8 SWG GALVANISED wire along with pole to pole cables from feeder pillars. Nos 100 22,500.00 2,250,000.00 For Damaged street Light pole repacement , details sheet is enclosed herewith for reference.
33 Copper Flexi Cable 3X1.5 Sq. mm Supply & Installation of 3Cx1.5 sq. Cu Flexible FRLS Wire for connection of light fitting. ( From Pole Junction Box to light fixtures) Rmt 12000 65.00 780,000.00 ( From Pole Junction Box to light fixtures), details sheet is enclosed herewith for reference. Spare quantity considered
34 Single Arm 1.0 Mtr 10 Degree Supply Installation Testing & Commissioning of 1.0 mtr. long & 10-degree Tilt angle Hot dip galvanised Single Arm bracket made up of 40NB dia GI pipe suitable to mount on TOP of pole having top 70mm A/F or as per existing pole top pipe diameter. Nos 20 1,150.00 23,000.00 For Damaged street Light pole repacement , details sheet is enclosed herewith for reference. 100 arms to be considered as per pole instead 90 arms are taken
35 Double Arm 2 Mtr. 16 Degree Supply Installation Testing & Commissioning of 2 mtr long & 16-degree Tilt angle hot dip galvanised Single Arm bracket made up of 40NB Dia GI pipe suitable to mount on Side of pole on Service Roadside (Differential Arm pole) Nos 30 1,500.00 45,000.00 For Damaged street Light pole repacement , details sheet is enclosed herewith for reference. 10 No's Qty Increased as par 100 No's Pole
36 Double Arm 2.5 mtr 10 Degree Supply Installation Testing & Commissioning of 2.5 mtr. Long & 10 degree Tilt Angle hot dip galvanised Double Arm bracket made up of 40NB dia GI pipe suitable to mount on TOP of pole having top 70mm A/F or as per existing pole top pipe diameter. Nos 50 2,500.00 125,000.00 For Damaged street Light pole repacement , details sheet is enclosed herewith for reference.
37 RCC Foundation (M20) for 10 Mtr Octagonal Pole RCC Foundation (M20) for 10 Mtr Octagonal Pole Providing of RCC Foundation (M20) Foundation Size: 600mm x 600mm x 1200 mm. with bolts 4 nos of octagonal pole including excavation of pole pit. The scope shall also include grouting of foundation bolts including watering and ramming & provision for passage of cable by using suitable size GI pipe / DWC pipe / HDPE pipe. Vendor submit the civil foundation details from structure consultants for approval from IE / Client Note:- If the any existing foundation is found suitable for installation of the new pole the same will be used after approval and construction of new foundation will not be required. Nos 100 2,200.00 220,000.00 For Damaged street Light pole repacement , details sheet is enclosed herewith for reference. Drawing & UOM to be revised Drawing sent
38 L Bracket with Fastener/ Bolt for 10 mtr Octagonal Street Light Pole SITC of MS wall mounted steel bracket on RE wall to rest streetlight octagonal pole incl. Hilti make fastener. Contractor shall have to submit structural design for the same. Vendor submit the MS Foundation bracket details from structure consultants for approval from IE / Client Nos 20 3,500.00 70,000.00 Some poles at Km 295 and Km 403 are hanging due to improper fixing and require re-fixing to ensure proper alignment and structural stability.
39 200W LED STREET LIGHT FOR MAIN CARRIAGEWAY LIGHTING + SERVICE ROAD LIGHTING SITC of 200W SMD LED Streetlight fixture with System efficacy of 135 lm/W (27000 lumens). Luminaire shall be made up of pure polyester powder coated die cast Aluminium housing with IP rated high purity Polycarbonate lens . The luminaire should have a dimension of 417mm x 285mm x 2mm ± 2mm appoximate weight of 3.8 Kg ± 0.25 Kg. The housing should be made of LM6/ADC12 Alloy non-corrosive Single Piece pressure die-cast aluminum to withstand extreme environments. All external hardware must be of SS304 grade. Luminaire shall be designed with street optic LENS for uniform light distribution. Maximum LENS dome top temperature shall be less than 95°C at 45°C ambient temperature. LM 80-08 compliant LEDs of EMC/ceramic package of wattage of 4W-5W from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 and IK10 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K CRI of Minimum 70 and SDCM of < 5. LEDs must be driven at max 70% of the rated current. MCPCB with Aluminium core and copper thickeness of 35 micron to be used for LED mounting. LED Driver shall be silicone potted Integrated type Isolated Constant Current with range 140-280V AC. Driver Efficiency > 88% & 4 KV internal surge protection with additional 10KV SPD mounted inside the luminaire and firmly fixed to the housing Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED Driver must have short circuit open circuit Auto cut-off protection for low and high input voltage. Driver must have 440V input voltage protection for 8 hours. LED driver should have over temperature protection. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 3:2013; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Make-Wipro/Philips/Bajaj/Crompton/Havells Safely removing and shifting old fixtures, and depositing them in writing at the toll plaza or store, etc. Nos 2550 7,250.00 18,487,500.00 Required Total installation of 200 W LED Light fixture in place of 400W HPSV , details sheet is enclosed herewith for reference.
40 Wallmounted 80 W LED Flood Street Light FOR UNDERNEATH VUP LIGHTING SITC of 80 W LED High bay light having min system lumen output of 10500. Min system Efficacy should be > 130 Lm/w. Housing Should be made up of Al die cast having High Transmittance Polycarbonate cover. Luminaire should be IP66 and IK08 Protected. Luminaire should have proper Heat sink for thermal management with eye bolt mounting. Luminaire should have beam angle of 110 Deg Wide beams for proper light distribution CRI > 80 SDCM < 5 with lifeclass of 50000 Hrs @L70B50.. Driver use should be of potted and encapsulated only. Operating voltage range of driver should be of 140 – 270 VAC with 4 KV internal surge protection THD < 10% PF > 0.95 High voltage cut off & Auto restart @ 320 VAC Phase to phase 440 V Protection for 8 Hrs. Driver should be of reputed makes such as Philips Xitanium / Osram / Meanwell only. Driver & luminaire both should be BIS Approved only. Luminaire should be tested under NABL Accredited Lab for LM79/LM80/TTC. Similar to Philips BY225P LED100S CW WB PSU FG GR Nos 210 4,250.00 892,500.00 Location for underpass lighting details sheet is enclosed herewith for reference.
41 Highmast Repairing Supply & Laying of raising lowering system comprising double drum winch 6 / 8 mm diameter SS wire rope trailing cable connector integral power tool motor manual handle junction box lightening finial. Nos 30 25,000.00 750,000.00 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution. Total number of highmast to be repaired is 64. But the quantity to be revised as 10 Nos Highmast 20 Qty reduced UOM Revised
42 Aviation lamp for High mast SITC of LED type double dome aviation obstruction light for 30 Mtr Highmast. Nos 30 1,500.00 45,000.00 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
43 Re-installation of High mast pole when required Erection of the high mast with the help of suitable tools and plants wiring of luminaries with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm lugs MCB and all labour as a complete job. Rate include cranes for using lowering & re-installation of High mast pole. Nos 10 25,000.00 250,000.00 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution. UOM Revised
44 HIGH MAST FEEDER PANEL 30 Mtr Highmast SITC of outdoor stand mounted feeder pillar with 40A TPN MCB incomer single dial time switch 40A FP contactor for the automatic switching of luminaries power tool control with 2 no 9A contactors and raise lower push button Incoming 35 sq. mm and out going 20 x1.5 sq. mm terminals. (4) Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour. (Foundation civil design will be approved by structural consultants). Nos 35 20,000.00 700,000.00 Location for installation of Highmast Control Panel details sheet is enclosed herewith for reference.
45 400 WATT LED LIGHTING FIXTURES FOR HIGH MAST @ ALL JUNCTIONS + GRADE SEPARATED JUNCTIONS ETC. SITC of 400W SMD LED Floodlight fixture with System efficacy of 125 lm/W (50000 lumens). Luminaire shall be made up of LM6/ADC12 Alloy non-corrosive pure polyster power coated die cast Aluminium housing with PC lens. Lumianire should be of dimension 319mm x 507mm x 97mm height ± 5mm height and the approximate weight should be within the 12.0Kg ± 0.5Kg. Luminaire should be available with 25° and 60° beam angle option. Luminaire should be made of four individual modules of 100W to 125W each. All external hardware must be of SS304 grade. LM 80-08 compliant LEDs of EMC/ceramic package of wattage of 5W from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Maximum LENS dome top temperature shall be less than 95°C at 45°C ambient temperature. Luminaire shall be with IP66 and IK07 protection. It should be cabable to operating under ambient temperature range of -10°C to +45°C. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K CRI of Minimum 70 and SDCM < 5. LEDs must be driven at max 70% of the rated current. MCPCB with Aluminium core and copper thickeness of 35 micron to be used for LED mounting. LED Driver shall be silicone potted Integrated type Isolated Constant Current with range 140-280V AC. Driver Efficiency > 88% & 4 KV internal surge protection with additional 10KV SPD mounted inside the luminaire and firmly fixed to the housing Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. LED Driver must have short circuit open circuit Auto cut-off protection for low and high input voltage. LED driver should have 440V AC protection for atleast 8 hours.LED driver should have over temperature protection.Individual drivers should be provided with individual modules along with ventilated enclousure to hide the wirings. Driver must be with Aluminium casing. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Nos 510 13,500.00 6,885,000.00 Location for installation/replacement of Highmast LED Light fixture in Place of HPSV Fixture, details sheet is enclosed herewith for reference. 7 numbers of spare is considerd in the qty
46 Internal Electrical Wiring (Lighting Circuit) for Toll Plaza :- Providing and erecting Point wiring with 1.1 KV grade ISI marked 2 X 1.5 sq. mm copper PVC insulted FRLS wire with 1.5 sq. mm (green) copper PVC insulated FRLS wire for earth continuity in FIA approved ISI mark medium class white colour 20/25 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution erected on/in Brick Wall / slab along with continuous G.I. fish wire to draw wires and laid in approved manner zari for PVC pipe and boxes shall be filled with cement mortar and finishing the surface to match the wall / ceiling complete with approved make 5/6 Amp. ISI make modular type switch and accessories mounted in 20 G. G.I. company fabricated metallic box covered with appropriate front plate modules erected flushed with wall / ceiling with necessary modular lamp holder / modular ceiling rose / HD Connector (make & model approved by EIC and matching colur with switches accessories) (Deep Junction box 75mm depth if required) as directed for concealed wiring. Light point. Necessary sheet / tape / polythene / sand must be erected or filled in all box to prevent mortar going into the box. Length of point wiring must not increase than 10 mtr. For that necessary switch boards and their locations must be finalised before execution by agency otherwise payment will not be done for extra long point. (For future extention if required agency has to erect one higher size metal box and modular plate as per instruction of EIC. Cost of blank plate shall be paid as per tender item) [This item include cleaning (inside/outside) of all G.I. switch boards electric point box fan box MCBDB & box cutting plaster finishing for modular plate without any gap] [conductor resistance should be as per IS:8130/1984] NOS 100 750.00 75,000.00 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
47 Internal Electrical power Wiring for Toll Plaza :- Providing and fixing Plug Point wiring with 1.1 KV grade ISI marked approved make 2 x 2.5 sq.mm copper PVC insulated FRLS wire with 1.5 sq.mm (green) copper PVC insulated FRLS wire for earth continuity in FIA approved ISI mark white colour medium class 20/25 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution erected in wall/slab along with continuous G. I. fish wire to draw wires and laid in approved manner zari for PVC pipe & boxes shall be filled with cement mortar & finishing the surface to match the wall / ceiling complete with 16 Amp Modular type Swich and accessories mounted in 20 G. GI company fabricated metallic box covered with appropriate front plate modules erected flushed with wall. (a) 16 Amp. Indicator switch & 1 No. 6/16 A universal socket white colour suitable for 3/5 pin top duly both having ISI mark. (Necessary sheet / tape / polythene / sand must be erected or filled in all box To Prevent Mortor Going In To The Box) (Conductor resistance should be as per IS:8130/1984) ( FOR POWER PLUG IN BOOTH & ADMIN BUILDING ) NOS 40 1,550.00 62,000.00 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
48 Power Wiring for (A.C POINT / BLOWER ONLY FOR BOOTH & ADMIN BUILDING) Providing & Erecting Plug Point wiring with approved ISI marked 1.1 kv grade 2 x 4.0 sq.mm copper PVC insulated FRLS wire with 2.5 sq.mm (green) copper PVC insulated FRLS wire for earth continuity in FIA approved ISI mark white colour medium class 25 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution erected in wall / slab along with continuous G.I. fish wire to draw wires and laid in approved manner. zari for PVC pipe & boxes shall be filled with cement mortar & finishing the surface to match the wall / ceiling complete with approved make 20 Amp. Modular type indicator switch and accessories mounted in 20 SWG GI company fabricated metallic box covered with appropriate front plate modules erected flushed with wall / ceiling. (a) 20 Amp Indicator switch & 1 No. 20 A universal socket white colour suitable for 3 pin top duly both having ISI mark(A.C POINT / BLOWER ONLY FOR BOOTH & ADMIN BUILDING ) (Necessary sheet / tape / polythene / sand must be erected or filled in all box to Prevent Mortor Going In to The Box) the quantity will be consider in set/point. NOS 60 1,850.00 111,000.00 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
49 Surge Protection Device (SPD) Supply Installation Testing & Commissioning of Three Phase 440 V Surge Suppressor protection Device (SPD) & 40 Amp TPN MCB (or As per SPD OEM guide line for the protection of SPD which is erected such a way that it can be operated easily) SPD must be capable to protect all electrical and electronics equipments if SPD blast or fuse then the panel builder must have replace it soon during defect liability period. (Hakel ikra OBBO make) (With Three year Gaurantee/warranty) Nos 6 3,500.00 21,000.00 For Electrical equipment safety, It will be installed in 1 No's in Admin building & 2 No's in SWB Building at both toll plaza
50 6-Way SPN DB Board Double Door SITC of Approved make 6-Way SPN Double Door metal clad D.B. company prewired having Incoming and outgoing as mentioned below with NL suitable to operate on 230 Volt A.C. power and having overload and short circuit tripping element breaking capacity 10KA (for all MCB & ELCB) to be erected in flush type and company fabricated 16 G.M.S./ IK 08 Certificate sheet box with powder coated inside and outside after apply seven tank chemical process of M.S. sheet cover complete with suitable integral single piece construction tinned copper busbar- and link with all necessary interconnection and with neccessary size wooden board for mounting MCBDB . Manufacturer must be Provided .(1)IP 43 Protection Certificate.(2) Seven tank Powder Coating Certificate.(3) Copper/Brass make Neutral & Earthing link with Isolation and Protecting Cover. (a) For 6 Way SPN MCBDB with I/c:- 25 Amp DP RCBO(RCCB+MCB) 10KA & O/G :- C-curve 6-16 Amp SP MCB :- 4 Nos. For Toll booth UPS power & For Electrical Room + Medical Aid post Nos 36 7,500.00 270,000.00 Panel/Switch borad/ MCB Board are required at the both toll plaza for cable renovation & Proper Load separation work. 16 Toll booth tunnels & 2 extra taken for other equipment for each Toll Plaza
51 8-Way SPN Distribution Board Double Door SITC of Approved make 8-Way SPN Double Door metal clad D.B. company prewired having Incoming and outgoing as mentioned below with NL suitable to operate on 230 Volt A.C. power and having overload and short circuit tripping element breaking capacity 10KA (for all MCB & ELCB) to be erected in flush type and company fabricated 16 G.M.S./ IK 08 Certificate sheet box with powder coated inside and outside after apply seven tank chemical process of M.S. sheet cover complete with suitable integral single piece construction tinned copper busbar- and link with all necessary interconnection and with neccessary size wooden board for mounting MCBDB . Manufacturer must be Provided .(1)IP 43 Protection Certificate.(2) Seven tank Powder Coating Certificate.(3) Copper/Brass make Neutral & Earthing link with Isolation and Protecting Cover. (a) For 6 Way SPN MCBDB with I/c:- 32 Amp DP RCBO(RCCB+MCB) 10KA & O/G :- C-curve 6-20 Amp SP MCB :- 6 Nos. NOS 8,750.00 0.00 Panel/Switc borad/ MCB Board are required at the both toll plaza for cable renovation & Proper Load separation work. To be removed from BOQ Removed from PR
52 8-Way TPN DB Board SITC of Approved make 8-Way TPN DB - Three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) Double Door metal clad D.B. company prewired having Incoming and outgoing as mentioned below with NL suitable to operate on 415 Volt A.C. power and having overload and short circuit tripping element breaking capacity 10KA (for all MCB & ELCB) to be erected in flush type and company fabricated 16 G.M.S./ IK 08 Certificate sheet box with powder coated inside and outside after apply seven tank chemical process of M.S. sheet cover complete with suitable integral single piece construction tinned copper busbar- and link with all necessary interconnection and with neccessary size wooden board for mounting MCBDB . Manufacturer must be Provided .(1)IP 43 Protection Certificate.(2) Seven tank Powder Coating Certificate.(3) Copper/Brass make Neutral & Earthing link with Isolation and Protecting Cover. (a) For 8 Way TPN MCBDB I/c:- 63 Amp FP MCB 10KA C-63 A DP ELCB 30ma 10KA -03 nos O/G :- C-curve 6-32 Amp SP MCB :- 21 Nos. For Toll plaza - Admin building GF + FF - Lighting & Raw power DB & Toll lane TMS equipment Nos 6 22,500.00 135,000.00 Panel/Switc borad/ MCB Board are required at the both toll plaza for cable renovation & Proper Load separation work.
53 PVC PIPES 25 MM Dia Providing and erecting Medium Class FIA approved and ISI mark white colour (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & clamps on / in wall / ceiling along with continuous fish wire to draw mains with necessary fittings and junction boxes for following dia. (a) 25 mm. dia. Rmt 1000 35.00 35,000.00 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
54 2 Type x 1.5 sq.mm. Single core FRLS copper PVC Insulated wire Providing and laying Mains with FRLS PVC Insulated wire ISI marked 1.1 KV grade with FIA approved ISI mark medium class 20/25/32 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution to be erected on/in brick wall / slab along with continuous G. I. fish wire to draw mains laid in approved manner with plastering by cement mortar & finishing the surface to match the wall / ceiling complete with FRLS PVC insulated wire for earth continuity. (Approved ISI make only) [a] 2 x 1.5 sq.mm. FRLS copper multi stranded conductor mains with 1.5 sq.mm. FRLS copper multi stranded conductor for earthing as per standard colour code. [conductor resistance should be as per IS:8130/1984] for Toll plaza Main Wiring Rmt 500 85.00 42,500.00 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
55 2 type x 2.5 sq.mm. Single core FRLS copper flexi wire multi stranded conductor mains with 1.5 sq.mm. FRLS copper multi stranded conductor Providing and laying Mains with FRLS PVC Insulated wire ISI marked 1.1 KV grade with FIA approved ISI mark medium class 20/25/32 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution to be erected on/in brick wall / slab along with continuous G. I. fish wire to draw mains laid in approved manner with plastering by cement mortar & finishing the surface to match the wall / ceiling complete with FRLS PVC insulated wire for earth continuity. (Approved ISI make only) [b] 2 x 2.5 sq.mm. FRLS copper multi stranded conductor mains with 1.5 sq.mm. FRLS copper multi stranded conductor for earthing as per standard colour code. (Conductor resistance should be as per IS:8130/1984) Rmt 1500 160.00 240,000.00 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
56 2 Type x 4.0 sq.mm. FRLS copper multi stranded conductor mains with 2.5 sq.mm. FRLS copper multi stranded conductor for earthing Providing and laying Mains with FRLS PVC Insulated wire ISI marked 1.1 KV grade with FIA approved ISI mark medium class 20/25/32 mm dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution to be erected on/in brick wall / slab along with continuous G. I. fish wire to draw mains laid in approved manner with plastering by cement mortar & finishing the surface to match the wall / ceiling complete with FRLS PVC insulated wire for earth continuity. (Approved ISI make only) [c] 2 Type x 4.0 sq.mm. FRLS copper multi stranded conductor mains with 2.5 sq.mm. FRLS copper multi stranded conductor for earthing as per standard colour code. [conductor resistance should be as per IS:8130/1984] Rmt 1500 195.00 292,500.00 The quantity is considered approximate and will be done only if required, based on the site conditions at the time of work execution.
57 LED Tube Light 20-24 W 4 feet SITC Of Max 24 Watt LED Indoor Commercial make high efficiency performance Tube rod Approx. 4 feet (lamp) with combination of high quality diffused polycarbonate and alluminium base dedicated heat sink for better perfomance of LED and also long life.High quality LED must be placed on metal core printed circuit board for better heat dissipation. seprate driver with all protection like under voltage (160V to 270V) over voltage protection 2 KV surge protection.The life of lamp should have 25 000 hrs at L70 THD<15% efficiency >=110lm/w with high power factor > 0.90 with CRI > 80 for better color rendition total lumens should be min 2400. The lamp should be suitable for T8 box type fitting made form CRCA sheet and white powder coated.The data sheet of LM79 for complete lamp can also be provided (Note:-The manufacturer/ authorised Channel partner of the manufacturer has to submit 4 yr free replcement Guarantee for complete Fixture ) (Approval will be given strictly subject to item specification). Nos 50 650.00 32,500.00 For installation Tunel with proper wiring at both toll Plaza
58 Cable Tray 300X40X4 mm Supplying and erecting approved make GRP Perforated type Cable Tray with required GRP Straight Coupler Plates Corner etc. Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System Glass Content : 55 – 60 % - - Standard Length : 3000mm- Support Span – 1500mm Deflection L/200 - Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94 Very Low Flammability - Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65. (E) Width - 300 mm Pultruded “C” Channel with 40mm Sides 4mm Thickness Loading 25 Kg./Mtr. ( Sumip coromandak Eircon Satyam -composite Make or equivalent make app by engineer in charge subject to above specification) Rmt 100 750.00 75,000.00 For installation Tunel & near the admin building for proper cabling/dressing at both toll Plaza
59 8 SWG GI Earthing Wire upply & Laying Hot Deep 8 swg GI earth wire in horizontal or vertical run in ground/surface/recess including riveting soldering saddles making connection etc. as required. from Street Light Pole to pole connection & laying with Existing Armoured cable Rmt 32000 15.00 480,000.00 For all existing Pole earthing , Panel, & highmast earthing 20000 qty reduced
60 200A 415 Volts TPN Rewireable Cut-Out fuse units with mounting Bracket Supplying, Installing, Testing & Commissioning (SITC) of TPN Rewireable Switch Fuse Unit, rated 200 Ampere, 415 Volt AC, 50 Hz, 3-Phase, 3-Pole, complete with MS mounting bracket and accessories, suitable for outdoor highway street lighting application. The unit shall be installed after the energy meter and before the street light feeder pillar panel, complete in all respects as per specifications and site requirements.Quick make and break operation Enclosure made of CRCA sheet steel, duly pre-treated and powder coated, Hard bright tin-plated copper contacts for Terminals suitable for Aluminium and Copper conductors, Porcelain fuse carriers with fully shrouded live parts, Door interlocking facility provided for safety, Knock-outs provided at top, bottom and rear sides for cable entry Separate fuse and terminal block arrangement, Adequate internal space for wiring and maintenance PVC gasket provided for weather-proof sealing, MS mounting bracket complete with clamps, nuts and bolts Nos 10 15,000.00 150,000.00 The quantity is considered approximate and will be installed only if required, based on the site conditions at the time of work execution. It will be installed after energy meter & before load or Fedeer pillar Panel
Location for installation of Main Feeder Pillar cum timer Control Panel for Street Light & Highmast
SR NO Equipment Name Chainage Qty Remark
1 Street Light & Highmast 270.000 1 Panel Rusted & Damaged
2 Street Light & Highmast 274.170 1 Panel Rusted & Damaged
3 Street Light & Highmast 277.660 1 Panel Rusted & Damaged
4 Street Light & Highmast 282.380 1 Panel Rusted & Damaged
5 Street Light & Highmast 288.200 1 Panel Rusted & Damaged
6 Street Light 289.120 1 Panel Rusted & Damaged
7 Street Light 290.600 1 Not Available
8 Street Light 314.640 1 Not Available
9 Street Light & Highmast 315.000 1 Panel Rusted & Damaged
10 Street Light & Highmast 334.250 1 Panel Rusted & Damaged
11 Street Light & Highmast 336.650 1 Panel Rusted & Damaged
12 Street Light 348.600 1 Not Available
13 Street Light & Highmast 358.050 1 Panel Rusted & Damaged
14 Highmast 361.600 1 Panel Rusted & Damaged
15 Street Light & Highmast 363.650 1 Panel Rusted & Damaged
16 Highmast 365.450 1 Panel Rusted & Damaged
17 Street Light & Highmast 370.100 1 Not Available
18 LED STREET LIGHT 370.700 1 Not Available
19 Highmast 372.350 1 Not Available
20 HPSV STREET LIGHT 377.350 1 Not Available
21 LED STREET LIGHT 382.750 1 Not Available
22 HPSV STREET LIGHT 383.650 1 Not Available
23 HPSV STREET LIGHT 388.130 1 Not Available
24 HPSV STREET LIGHT 392.470 1 Not Available
25 HPSV STREET LIGHT 396.200 1 Panel Rusted & Damaged
26 HPSV STREET LIGHT 396.200 1 Panel Rusted & Damaged
27 HPSV STREET LIGHT 401.450 1 Panel Rusted & Damaged
28 LED STREET LIGHT 403.400 1 Not Available
29 HPSV STREET LIGHT 407.600 2 Panel Rusted & Damaged
30 LED STREET LIGHT 413.900 1 Not Available
31 HPSV STREET LIGHT 417.800 2 Panel Rusted & Damaged
32 HPSV STREET LIGHT 418.750 2 Panel Rusted & Damaged
TIMERS, CONTACTORS, MCB, MCCB
S. No. Chainage Side Location Highmast/ Street Light Timer Remark
1 262.900 263.150 LHS Truck Layby Street Light 1
2 266.520 266.520 LHS Shoulder Highmast 1 Faridpur Toll Plaza
3 266.620 266.620 RHS Shoulder Highmast 1 Faridpur Toll Plaza
4 266.720 266.720 LHS Shoulder Highmast 1 Faridpur Toll Plaza
5 266.980 266.980 LHS Shoulder Highmast 1 Faridpur Toll Plaza
6 266.980 266.980 RHS Shoulder Highmast 1 Faridpur Toll Plaza
7 267.100 267.100 LHS Shoulder Highmast - Faridpur Toll Plaza
8 267.100 267.100 RHS Shoulder Highmast - Faridpur Toll Plaza
9 267.160 267.160 RHS Shoulder Highmast 1 Faridpur Toll Plaza
10 267.290 267.290 LHS Shoulder Highmast 1 Faridpur Toll Plaza
11 268.150 268.150 RHS Shoulder Highmast 1
12 269.700 270.350 Median MCW Street Light 1
13 270.100 270.100 RHS Shoulder Highmast -
14 277.300 278.100 Median MCW Street Light 1
15 277.770 277.770 LHS Shoulder Highmast 1
16 277.770 277.770 RHS Shoulder Highmast 1
17 282.000 282.800 Median MCW Street Light 2
18 282.380 282.380 LHS Shoulder Highmast 1
19 282.380 282.380 RHS Shoulder Highmast 1
20 287.850 288.650 Median MCW Street Light 2
21 288.900 289.500 Median MCW Street Light 2
22 295.000 295.730 LHS MCW Street Light 2
23 295.000 295.730 RHS MCW Street Light 2
24 295.370 295.370 RHS Shoulder Highmast 1
25 303.250 303.950 Median MCW Street Light 2
26 303.650 303.650 RHS Shoulder Highmast 1
27 305.050 305.900 LHS MCW Street Light 2
28 305.050 305.900 RHS MCW Street Light 2
29 305.410 305.410 LHS Shoulder Highmast 1
30 305.410 305.410 RHS Shoulder Highmast 1
31 306.150 306.300 RHS Truck Layby Street Light 1
32 315.350 316.000 LHS MCW Street Light 1
33 315.750 315.750 LHS Shoulder Highmast 1
34 315.750 315.750 RHS Shoulder Highmast -
35 317.420 317.420 LHS Shoulder Highmast 1
36 325.100 326.000 LHS MCW Street Light 2
37 325.100 326.000 RHS MCW Street Light 2
38 325.630 325.630 LHS Shoulder Highmast 1
39 325.630 325.630 RHS Shoulder Highmast 1
40 329.100 330.000 LHS MCW Street Light 2
41 329.100 330.000 RHS MCW Street Light 2
42 329.560 329.560 LHS Shoulder Highmast 1
43 329.560 329.560 RHS Shoulder Highmast 1
44 331.950 331.950 RHS Shoulder Highmast -
45 332.250 332.250 LHS Shoulder Highmast -
46 332.250 332.250 RHS Shoulder Highmast 1
47 336.600 336.600 RHS Shoulder Highmast 1
48 357.600 358.450 Median MCW Street Light 1
49 358.100 358.100 LHS Shoulder Highmast 1
50 358.100 358.100 RHS Shoulder Highmast 1
51 360.570 360.570 RHS Shoulder Highmast 1
52 361.600 361.600 LHS Shoulder Highmast 1
53 361.600 361.600 RHS Shoulder Highmast 1
54 363.400 363.950 Median MCW Street Light 1
55 365.450 365.450 LHS Shoulder Highmast 1
56 369.650 370.700 Median MCW Street Light 2
57 370.100 370.100 RHS Shoulder Highmast 1
58 371.750 371.750 RHS Shoulder Highmast - Maigalganj Toll Plaza
59 371.820 371.820 LHS Shoulder Highmast - Maigalganj Toll Plaza
60 372.020 372.020 LHS Shoulder Highmast - Maigalganj Toll Plaza
61 372.350 372.350 LHS Shoulder Highmast 1 Maigalganj Toll Plaza
62 372.350 372.350 RHS Shoulder Highmast 1 Maigalganj Toll Plaza
63 374.080 374.080 RHS Shoulder Highmast -
64 376.800 378.000 Median MCW Street Light 2
65 383.200 384.200 Median MCW Street Light 2
66 383.650 383.650 LHS Shoulder Highmast 1
67 383.650 383.650 RHS Shoulder Highmast 1
68 387.800 388.600 Median MCW Street Light 2
69 388.130 388.130 LHS Shoulder Highmast -
70 391.900 393.000 Median MCW Street Light 2
71 395.550 395.550 RHS Shoulder Highmast 1
72 395.750 396.600 LHS MCW Street Light 1
73 395.750 396.600 RHS MCW Street Light 1
74 401.500 401.500 RHS Shoulder Highmast 1
75 402.600 404.000 RHS MCW Street Light 2
76 407.290 408.000 LHS MCW Street Light 2
77 407.350 408.000 RHS MCW Street Light 2
78 407.600 407.600 LHS Shoulder Highmast -
79 416.340 417.060 LHS MCW Street Light 1
80 416.340 417.070 RHS MCW Street Light 1
81 416.550 416.550 LHS Shoulder Highmast 1
82 417.350 419.300 Median MCW Street Light 4
83 417.800 417.800 LHS Shoulder Highmast 1
Note:- All necessary contactors, timers, MCBs, etc., have been replaced by the departmental team. The quantities specified in the BOQ are estimates; they will be considered for billing only if installed by the vendor based on actual site requirements during the execution of the work.
TIMERS, CONTACTORS, MCB, MCCB
S. No. Chainage Side Location Highmast/ Street Light MCCB 100A Remark
1 269.700 270.350 Median MCW Street Light 1
2 282.380 282.380 LHS Shoulder Highmast 1
3 282.380 282.380 RHS Shoulder Highmast 1
4 295.000 295.730 LHS MCW Street Light 1
5 295.000 295.730 RHS MCW Street Light 1
Note:- All necessary contactors, timers, MCBs, etc., have been replaced by the departmental team. The quantities specified in the BOQ are estimates; they will be considered for billing only if installed by the vendor based on actual site requirements during the execution of the work.
MCB 6A-25A 1 Pole
SR NO Equipment Name Chainage Village Name Description Chainage Total no of Pole Total No of Fixture MCB 6A-25A 1 Pole Remark
From To Length in Mtr
1 LED STREET LIGHT 263.000 Kesharpur Truck Lay By Truck Lay By 262.900 263.150 250 8 8 8 LED Street Light 493
3 Toll Plaza 266.980 Toll Plaza Toll Plaza 266.820 266.980 160 0 0 20 HPSV STREET LIGHT 310
6 HPSV STREET LIGHT 270.100 Faridpur Bypass Bareilly HPSV STREET LIGHT 269.700 270.350 650 26 52 5 Toll Plaza 40
8 HPSV STREET LIGHT 274.170 NEAR GURUDWARA FARIDPUR HPSV STREET LIGHT 273.700 274.450 750 28 56 5
9 HPSV STREET LIGHT 277.750 Faridpur Bareilly Highmast 277.300 278.100 800 28 56 5
10 HPSV STREET LIGHT 282.380 NEELAM VENEER, Tisuwa HPSV STREET LIGHT 282.000 282.800 800 29 58 5
11 HPSV STREET LIGHT 288.200 Uchesiya Mod Fatehganj Purbi Near Gupta Restourent HPSV STREET LIGHT 287.850 288.650 800 29 58 5
12 HPSV STREET LIGHT 289.120 Fatehganj Purbi HPSV STREET LIGHT 288.900 289.500 600 22 44 5
13 LED STREET LIGHT 290.600 Shalpur Navdia ROB HPSV STREET LIGHT 290.050 291.350 1300 167 167 167
14 HPSV STREET LIGHT 295.370 Katara Chauraha LHS HPSV STREET LIGHT 295.000 295.730 730 30 60 5
15 HPSV STREET LIGHT 295.370 Katara Chauraha RHS HPSV STREET LIGHT 295.000 295.730 730 30 60 30
16 HPSV STREET LIGHT 303.650 Mansoorpur Tilhar Cut HPSV STREET LIGHT 303.250 303.950 700 26 52 5
17 HPSV STREET LIGHT 305.440 Tilahar LHS HPSV STREET LIGHT 305.050 305.900 850 37 74 5
18 HPSV STREET LIGHT 305.410 Tilahar RHS HPSV STREET LIGHT 305.050 305.900 850 37 74 5
19 LED STREET LIGHT 306.100 Tilhar City Rd Truck Lay By Truck Lay By 306.150 306.300 150 8 8 8
21 LED STREET LIGHT 314.640 Street Light HPSV STREET LIGHT 314.300 314.900 600 36 72 72
22 HPSV STREET LIGHT 315.750 Banthara HPSV STREET LIGHT 315.350 316.000 650 58 116 5
24 HPSV STREET LIGHT 325.580 Bareilly Mod LHS HPSV STREET LIGHT 325.100 326.000 900 32 64 10
25 HPSV STREET LIGHT 325.630 Bareilly Mod RHS HPSV STREET LIGHT 325.100 326.000 900 30 60 15
26 HPSV STREET LIGHT 329.560 Near BHARAT DHABA BRIDGE LHS HPSV STREET LIGHT 329.100 330.000 900 34 68 10
27 HPSV STREET LIGHT 329.560 Roza Bypass RHS HPSV STREET LIGHT 329.100 330.000 900 35 70 10
29 HPSV STREET LIGHT 331.950 NEAR DOON SCHOOL LHS, Ahmadpur Niwazpur HPSV STREET LIGHT 331.600 332.050 450 17 34 10
30 HPSV STREET LIGHT 331.950 NEAR DOON SCHOOL RHS Ahmadpur Niwazpur HPSV STREET LIGHT 331.600 332.050 450 16 32 10
31 HPSV STREET LIGHT 332.250 Honda Colony, Roza - 2 LHS Mandi Marg HPSV STREET LIGHT 332.050 332.500 450 16 32 10
32 HPSV STREET LIGHT 332.250 Kuda Plant, Roza -1 RHS Mandi Marg HPSV STREET LIGHT 332.050 332.500 450 17 34 10
33 HPSV STREET LIGHT 334.250 ROB RAILWAY CROSSING, LHS HPSV STREET LIGHT 333.700 334.900 1200 70 140 40
35 HPSV STREET LIGHT 336.650 Jamuhi, Shajahanpur Rd HPSV STREET LIGHT 336.300 337.100 800 66 132 10
36 LED STREET LIGHT 348.600 Truck Lay By Truck Lay By 348.450 348.700 250 16 16 16
38 HPSV STREET LIGHT 358.050 Barkheriya Jat HPSV STREET LIGHT 357.600 358.450 850 33 66 5
41 HPSV STREET LIGHT 363.650 Highmast RHS HPSV STREET LIGHT 363.400 363.950 550 21 42 5
43 HPSV STREET LIGHT 370.100 Chhapartala HPSV STREET LIGHT 369.650 370.700 1050 43 86 5
44 LED STREET LIGHT 370.700 Truck Lay By Truck Lay By 370.700 371.700 1000 8 8 8
46 Toll Plaza 372.100 Toll Plaza Maigalganj Toll Plaza 372.020 372.180 160 0 0 20
49 HPSV STREET LIGHT 377.400 Aurangabad / Maigalganj Bypass HPSV STREET LIGHT 376.800 378.000 1200 45 90 15
51 LED STREET LIGHT 382.750 Truck Lay By Truck Lay By 382.450 382.700 250 8 8 8
52 HPSV STREET LIGHT 383.650 Neri, Maholi HPSV STREET LIGHT 383.200 384.200 1000 42 84 5
53 HPSV STREET LIGHT 388.130 Bhudiya PO Kachuri, Sitapur HPSV STREET LIGHT 387.800 388.600 800 32 64 5
54 HPSV STREET LIGHT 392.470 Badagaon Maholi HPSV STREET LIGHT 391.900 393.000 1100 41 82 5
56 HPSV STREET LIGHT 396.200 Maholi LHS HPSV STREET LIGHT 395.750 396.600 850 32 64 5
57 HPSV STREET LIGHT 396.200 Maholi RHS HPSV STREET LIGHT 395.750 396.600 850 32 64 10
58 HPSV STREET LIGHT 401.450 RICHHAI CHAURAHA HPSV STREET LIGHT 401.100 402.000 900 35 70 5
59 LED STREET LIGHT 403.400 Hempur ROB RHS LED STREET LIGHT 402.600 404.000 1400 59 118 59
60 LED STREET LIGHT 403.650 Hempur ROB LHS LED STREET LIGHT 402.600 404.000 1400 59 118 59
62 HPSV STREET LIGHT 407.570 Katili Bridge LHS HPSV STREET LIGHT 407.290 408.000 710 27 54 5
63 HPSV STREET LIGHT 407.000 PAPER MILL BRIDGE II, KATILI RHS HPSV STREET LIGHT 407.290 408.000 710 28 56 5
65 LED STREET LIGHT 413.850 Naveen Chowk, OVER BRIDGE LED STREET LIGHT 413.830 413.830 0 30 60 30
67 LED STREET LIGHT 416.750 ROTI GODAM KANWAKHEDA LED STREET LIGHT 416.340 417.060 720 58 116 58
68 HPSV STREET LIGHT 417.800 Bahuguda Chauraha Bridge LED STREET LIGHT 417.350 418.050 700 26 52 5
70 HPSV STREET LIGHT 418.700 kamta sariya-1 HPSV STREET LIGHT 418.050 418.750 700 26 52 5
71 HPSV STREET LIGHT 418.700 kamta sariya-2 HPSV STREET LIGHT 418.750 419.350 600 28 56 5
10.0 Sq.mm 3 core & 4 core XLPE Aluminium Armoured Cable
Sr No Equipment Backup Power Source Connection Load Requirement ATMS Location Location of Existing Connection Distance from Existing Connection Distance From Existing Connection under 100 mtr Distance B/W 100 - 450 mtr for cable laying Distance above the 450 mtr for new connection considering Cable will be laid by Agency +Extra ROW to Median 10.0 Sq.mm XLPE Aluminium Armoured Cable Existing Connection taken for the Equipment Remark
3 TMCS 6hrs Solar with Raw Power 1KVA 263.200 263.000 0.200 0.200 0.100 0.100 LED Street Light The cable laying work for ATMS equipment falls under the scope of the ATMS agency. The fixed distance under the agency’s scope has not yet been finalized. As per the email received from the agency and the instructions from our ATMS team, a length of 100 meters has been considered as fixed under the agency’s scope. Based on this, the average cable length has been calculated for the balance length, which will fall under the scope of NHIT, while at the same locations, 100 meters of cable length will remain under the agency’s scope.
9 TMCS 6hrs Solar with Raw Power 2KVA 268.000 268.150 0.150 0.150 0.100 0.050 Highmast
20 TMCS 6hrs Solar with Raw Power 1KVA 274.000 274.170 0.170 0.170 0.100 0.070 HPSV Street Light
24 TMCS 6hrs Solar with Raw Power 1KVA 278.000 277.750 0.250 0.250 0.100 0.150 HPSV Street Light
30 TMCS 6hrs Solar with Raw Power 1KVA 282.000 282.380 0.380 0.380 0.100 0.280 HPSV Street Light
34 TMCS 24hrs Only Solar power NA 286.000 286.300 0.300 0.300 0.000 0.300 VMS
35 L VMS 24hrs Solar with Raw Power 1KVA 286.650 286.300 0.350 0.350 0.100 0.250 VMS
37 TMCS 6hrs Solar with Raw Power 1KVA 288.000 288.200 0.200 0.200 0.100 0.100 HPSV Street Light
38 TMCS 6hrs Solar with Raw Power 1KVA 289.000 289.120 0.120 0.120 0.100 0.020 HPSV Street Light
41 TMCS 6hrs Solar with Raw Power 1KVA 290.000 289.730 0.270 0.270 0.100 0.170 New Proposed VADS
42 TMCS 6hrs Solar with Raw Power 1KVA 291.000 290.600 0.400 0.400 0.100 0.300 LED Street Light
49 L VMS 24hrs Solar with Raw Power 1KVA 294.550 294.400 0.150 0.150 0.100 0.050 VIDS/PTZ Camera
50 TMCS 6hrs Solar with Raw Power 1KVA 295.000 295.370 0.370 0.370 0.100 0.270 HPSV Street Light
60 TMCS 6hrs Solar with Raw Power 1KVA 303.200 303.650 0.450 0.450 0.100 0.350 HPSV Street Light
61 TMCS 6hrs Solar with Raw Power 1KVA 304.000 303.650 0.350 0.350 0.100 0.250 HPSV Street Light
62 TMCS 6hrs Solar with Raw Power 1KVA 305.000 305.440 0.440 0.440 0.100 0.340 HPSV Street Light
67 TMCS 24hrs Only Solar power NA 309.000 309.200 0.200 0.200 0.000 0.200 VMS
68 VASD 6hrs Solar with Raw Power 2kva 309.400 309.200 0.200 0.200 0.100 0.100 VMS
69 VASD 6hrs Solar with Raw Power 2kva 309.410 309.200 0.210 0.210 0.100 0.110 VMS
79 TMCS 24hrs Only Solar power NA 317.000 317.420 0.420 0.420 0.100 0.320 highmast Connection Pending
80 L VMS 24hrs Solar with Raw Power 1KVA 317.180 317.420 0.240 0.240 0.100 0.140 highmast Connection Pending
91 TMCS 24hrs Only Solar power NA 326.000 325.580 0.420 0.420 0.100 0.320 HPSV Street Light
98 VASD 6hrs Solar with Raw Power 2kva 330.250 330.600 0.350 0.350 0.100 0.250 VMS
99 VASD 6hrs Solar with Raw Power 330.260 -330.260
101 TMCS 6hrs Solar with Raw Power 1KVA 331.000 330.600 0.400 0.400 0.100 0.300 VMS
105 TMCS 6hrs Solar with Raw Power 1KVA 334.000 334.250 0.250 0.250 0.100 0.150 HPSV Street Light
106 TMCS 6hrs Solar with Raw Power 1KVA 335.000 334.850 0.150 0.150 0.100 0.050 HPSV Street Light
108 TMCS 24hrs Only Solar power NA 337.000 336.650 0.350 0.350 0.000 0.350 HPSV Street Light
134 TMCS 24hrs Only Solar power NA 356.000 356.350 0.350 0.350 0.100 0.250 Highmast
140 TMCS 6hrs Solar with Raw Power 1KVA 359.000 358.750 0.250 0.250 0.100 0.150 VMS connection Pending
143 VIDES 6hrs Solar with Raw Power 2KVA 360.350 360.570 0.220 0.220 0.100 0.120 Highmast
144 VIDES 6hrs Solar with Raw Power 360.450 360.570 0.120 0.120 0.100 0.020 Highmast
145 TMCS 6hrs Solar with Raw Power 2KVA 361.000 360.570 0.430 0.430 0.100 0.330 Highmast
146 L VMS 24hrs Solar with Raw Power 361.200 361.630 0.430 0.430 0.100 0.330 Highmast
147 TMCS 6hrs Solar with Raw Power 1KVA 362.000 361.630 0.370 0.370 0.100 0.270 Highmast
149 TMCS 6hrs Solar with Raw Power 1KVA 364.000 363.650 0.350 0.350 0.100 0.250 HPSV Street Light
150 TMCS 6hrs Solar with Raw Power 1KVA 365.000 365.450 0.450 0.450 0.100 0.350 Highmast
155 VASD 6hrs Solar with Raw Power 2kva 369.300 369.650 0.350 0.350 0.100 0.250 HPSV Street Light
156 VASD 6hrs Solar with Raw Power 369.350 369.650 0.300 0.300 0.100 0.200 HPSV Street Light
159 TMCS 6hrs Solar with Raw Power 1KVA 371.000 370.700 0.300 0.300 0.100 0.200 LED Street Light connection Pending
162 L VMS 24hrs Solar with Raw Power 1KVA 373.850 374.080 0.230 0.230 0.100 0.130 Highmast
163 VIDES 6hrs Solar with Raw Power 2KVA 373.920 374.080 0.160 0.160 0.100 0.060 Highmast
168 TMCS 24hrs Only Solar power NA 377.000 377.400 0.400 0.400 0.100 0.300 HPSV Street Light
184 VASD 6hrs Solar with Raw Power 2kva 387.690 388.130 0.440 0.440 0.100 0.340 HPSV Street Light
185 VASD 6hrs Solar with Raw Power 387.700 388.130 0.430 0.430 0.100 0.330 HPSV Street Light
186 TMCS 24hrs Only Solar power NA 388.000 388.130 0.130 0.130 0.000 0.130 HPSV Street Light
188 TMCS 24hrs Only Solar power NA 389.000 389.120 0.120 0.120 0.100 0.020 ATMS
198 TMCS 24hrs Only Solar power NA 396.000 396.200 0.200 0.200 0.000 0.200 Highmast
199 L VMS 24hrs Solar with Raw Power 1KVA 396.650 396.200 0.450 0.450 0.100 0.350 HPSV Street Light
204 TMCS 6hrs Solar with Raw Power 1KVA 401.000 401.450 0.450 0.450 0.100 0.350 HPSV Street Light
206 TMCS 24hrs Only Solar power NA 403.000 403.400 0.400 0.400 0.100 0.300 LED Street Light
222 VIDES 6hrs Solar with Raw Power 2KVA 412.270 412.450 0.180 0.180 0.100 0.080 Highmast
223 VIDES 6hrs Solar with Raw Power 412.300 412.450 0.150 0.150 0.100 0.050 Highmast
226 L VMS 24hrs Solar with Raw Power 1KVA 413.550 413.850 0.300 0.300 0.100 0.200 Highmast
230 TMCS 6hrs Solar with Raw Power 1KVA 417.000 416.750 0.250 0.250 0.100 0.150 NA
231 TMCS 6hrs Solar with Raw Power 1KVA 418.000 417.800 0.200 0.200 0.100 0.100 NA
232 TMCS 6hrs Solar with Raw Power 419.000 419.150 0.150 0.150 0.100 0.050 NA
233 L VMS 24hrs Only Solar power 419.000 419.150 0.150 0.150 0.100 0.050 HPSV Street Light
234 M-VMS 6hrs Solar with Raw Power 5KVA 419.150 419.400 0.250 0.250 0.100 0.150 VMS
Total Length in Mtr 0 16700 0 5300 11400
20 % Exta Lenght (if the agency is not able to provide cable above 100 Mtr) 2280
Total Cable for ATMS supply 13680
For Both Toll, Trucklay rest room, toilet room & admin Building from main electrical Panel 1320
Total Length of required cable in Mtr 15000
TIMERS, CONTACTORS, MCB, MCCB
S. No. Chainage Side Location Highmast/ Street Light MCB 1 Pole MCCB 100A MCB 63A, 4 Pole Contactor Timer Motor Chain Remark
1 262.900 263.150 LHS Truck Layby Street Light - - 1
2 266.520 266.520 LHS Shoulder Highmast - 1 1 - - Faridpur Toll Plaza
3 266.620 266.620 RHS Shoulder Highmast - 1 1 - - Faridpur Toll Plaza
4 266.720 266.720 LHS Shoulder Highmast 1 1 1 - - Faridpur Toll Plaza
5 266.980 266.980 LHS Shoulder Highmast - 1 1 - - Faridpur Toll Plaza
6 266.980 266.980 RHS Shoulder Highmast - 1 1 - - Faridpur Toll Plaza
7 267.100 267.100 LHS Shoulder Highmast - 1 - - - Faridpur Toll Plaza
8 267.100 267.100 RHS Shoulder Highmast - 1 - - - Faridpur Toll Plaza
9 267.160 267.160 RHS Shoulder Highmast - 1 1 - - Faridpur Toll Plaza
10 267.290 267.290 LHS Shoulder Highmast - 1 1 1 1 Faridpur Toll Plaza
11 268.150 268.150 RHS Shoulder Highmast - 1 1 - -
12 269.700 270.350 Median MCW Street Light 1 - 1 1
13 270.100 270.100 RHS Shoulder Highmast - - - 1 1
14 277.300 278.100 Median MCW Street Light - - 1 1
15 277.770 277.770 LHS Shoulder Highmast - - 1 - -
16 277.770 277.770 RHS Shoulder Highmast - - 1 - -
17 282.000 282.800 Median MCW Street Light - - 2 2
18 282.380 282.380 LHS Shoulder Highmast 1 - 1 1 - -
19 282.380 282.380 RHS Shoulder Highmast 1 - 1 1 - -
20 287.850 288.650 Median MCW Street Light - - 2 2
21 288.900 289.500 Median MCW Street Light - - 2 2
22 295.000 295.730 LHS MCW Street Light 1 3 2 2
23 295.000 295.730 RHS MCW Street Light 1 3 2 2
24 295.370 295.370 RHS Shoulder Highmast - 1 1 - -
25 303.250 303.950 Median MCW Street Light - - 2 2
26 303.650 303.650 RHS Shoulder Highmast - 1 1 1 1
27 305.050 305.900 LHS MCW Street Light - - 2 2
28 305.050 305.900 RHS MCW Street Light - - 2 2
29 305.410 305.410 LHS Shoulder Highmast - 1 1 - -
30 305.410 305.410 RHS Shoulder Highmast - 1 1 - -
31 306.150 306.300 RHS Truck Layby Street Light - - - 1
32 315.350 316.000 LHS MCW Street Light - - 1 1
33 315.750 315.750 LHS Shoulder Highmast - 1 1 1 1
34 315.750 315.750 RHS Shoulder Highmast - - - 1 1
35 317.420 317.420 LHS Shoulder Highmast - 1 1 - -
36 325.100 326.000 LHS MCW Street Light - - 2 2
37 325.100 326.000 RHS MCW Street Light - - 2 2
38 325.630 325.630 LHS Shoulder Highmast - 1 1 1 1
39 325.630 325.630 RHS Shoulder Highmast - 1 1 - -
40 329.100 330.000 LHS MCW Street Light - - 2 2
41 329.100 330.000 RHS MCW Street Light - - 2 2
42 329.560 329.560 LHS Shoulder Highmast - 1 1 - -
43 329.560 329.560 RHS Shoulder Highmast - 1 1 - -
44 331.950 331.950 RHS Shoulder Highmast - - - 1 1
45 332.250 332.250 LHS Shoulder Highmast - - - 1 1
46 332.250 332.250 RHS Shoulder Highmast - 1 1 1 1
47 336.600 336.600 RHS Shoulder Highmast - 1 1 - -
48 357.600 358.450 Median MCW Street Light 1 1
49 358.100 358.100 LHS Shoulder Highmast - 1 1 - -
50 358.100 358.100 RHS Shoulder Highmast - 1 1 - -
51 360.570 360.570 RHS Shoulder Highmast 1 1 1 - -
52 361.600 361.600 LHS Shoulder Highmast - 1 1 - -
53 361.600 361.600 RHS Shoulder Highmast 1 1 1 - -
54 363.400 363.950 Median MCW Street Light - - 1 1
55 365.450 365.450 LHS Shoulder Highmast - 1 1 - -
56 369.650 370.700 Median MCW Street Light - - 2 2
57 370.100 370.100 RHS Shoulder Highmast - 1 1 - -
58 371.750 371.750 RHS Shoulder Highmast - - - 1 1 Maigalganj Toll Plaza
59 371.820 371.820 LHS Shoulder Highmast - - - 1 1 Maigalganj Toll Plaza
60 372.020 372.020 LHS Shoulder Highmast - - - - 1 Maigalganj Toll Plaza
61 372.350 372.350 LHS Shoulder Highmast - 1 1 - 1 Maigalganj Toll Plaza
62 372.350 372.350 RHS Shoulder Highmast - 1 1 - - Maigalganj Toll Plaza
63 374.080 374.080 RHS Shoulder Highmast - - - - 1
64 376.800 378.000 Median MCW Street Light - - 2 2
65 383.200 384.200 Median MCW Street Light - - 2 2
66 383.650 383.650 LHS Shoulder Highmast - 1 1 - -
67 383.650 383.650 RHS Shoulder Highmast - 1 1
68 387.800 388.600 Median MCW Street Light - - 2 2
69 388.130 388.130 LHS Shoulder Highmast - - - - 1
70 391.900 393.000 Median MCW Street Light - - 2 2
71 395.550 395.550 RHS Shoulder Highmast - 1 1 - -
72 395.750 396.600 LHS MCW Street Light - - 1 1
73 395.750 396.600 RHS MCW Street Light - - 1 1
74 401.500 401.500 RHS Shoulder Highmast 1 1 1
75 402.600 404.000 RHS MCW Street Light - - 2 2
76 407.290 408.000 LHS MCW Street Light - - 2 2
77 407.350 408.000 RHS MCW Street Light - - 2 2
78 407.600 407.600 LHS Shoulder Highmast - - - 1 1
79 416.340 417.060 LHS MCW Street Light - - 1 1
80 416.340 417.070 RHS MCW Street Light - - 1 1
81 416.550 416.550 LHS Shoulder Highmast - - 1 - -
82 417.350 419.300 Median MCW Street Light - - 4 4
83 417.800 417.800 LHS Shoulder Highmast - 1 1 - -
Major requirement of one Pole MCB required for all existing 699 No's LED light fixture (263.000, 290.600, 306.100, 314.640, 348.600, 370.700, 382.750, 403.400, 403.650, 413.850, 416.750) & othar all location where HPSV Light available & at toll plaza if required 2000
Note:- All necessary contactors, timers, MCBs, etc., have been replaced by the departmental team. The quantities specified in the BOQ are estimates; they will be considered for billing only if installed by the vendor based on actual site requirements during the execution of the work.
10.0 Sq.mm 3 core & 4 core XLPE Aluminium Armoured Cable
Sr No Equipment Backup Power Source Connection Load Requirement ATMS Location Location of Existing Connection Distance from Existing Connection 10.0 Sq.mm XLPE Aluminium Armoured Cable Existing Connection taken for the Equipment Remark
3 TMCS 6hrs Solar with Raw Power 1KVA 263.200 263.000 0.200 0.100 LED Street Light The cable laying work for ATMS equipment falls under the scope of the ATMS agency. The fixed distance under the agency’s scope has not yet been finalized. As per the email received from the agency and the instructions from our ATMS team, a length of 100 meters has been considered as fixed under the agency’s scope. Based on this, the average cable length has been calculated for the balance length, which will fall under the scope of NHIT, while at the same locations, 100 meters of cable length will remain under the agency’s scope.
9 TMCS 6hrs Solar with Raw Power 2KVA 268.000 268.150 0.150 0.050 Highmast
20 TMCS 6hrs Solar with Raw Power 1KVA 274.000 274.170 0.170 0.070 HPSV Street Light
24 TMCS 6hrs Solar with Raw Power 1KVA 278.000 277.750 0.250 0.150 HPSV Street Light
30 TMCS 6hrs Solar with Raw Power 1KVA 282.000 282.380 0.380 0.280 HPSV Street Light
34 TMCS 24hrs Only Solar power NA 286.000 286.300 0.300 0.300 VMS
35 L VMS 24hrs Solar with Raw Power 1KVA 286.650 286.300 0.350 0.250 VMS
37 TMCS 6hrs Solar with Raw Power 1KVA 288.000 288.200 0.200 0.100 HPSV Street Light
38 TMCS 6hrs Solar with Raw Power 1KVA 289.000 289.120 0.120 0.020 HPSV Street Light
41 TMCS 6hrs Solar with Raw Power 1KVA 290.000 289.730 0.270 0.170 New Proposed VADS
42 TMCS 6hrs Solar with Raw Power 1KVA 291.000 290.600 0.400 0.300 LED Street Light
49 L VMS 24hrs Solar with Raw Power 1KVA 294.550 294.400 0.150 0.050 VIDS/PTZ Camera
50 TMCS 6hrs Solar with Raw Power 1KVA 295.000 295.370 0.370 0.270 HPSV Street Light
60 TMCS 6hrs Solar with Raw Power 1KVA 303.200 303.650 0.450 0.350 HPSV Street Light
61 TMCS 6hrs Solar with Raw Power 1KVA 304.000 303.650 0.350 0.250 HPSV Street Light
62 TMCS 6hrs Solar with Raw Power 1KVA 305.000 305.440 0.440 0.340 HPSV Street Light
67 TMCS 24hrs Only Solar power NA 309.000 309.200 0.200 0.200 VMS
68 VASD 6hrs Solar with Raw Power 2kva 309.400 309.200 0.200 0.100 VMS
69 VASD 6hrs Solar with Raw Power 2kva 309.410 309.200 0.210 0.110 VMS
79 TMCS 24hrs Only Solar power NA 317.000 317.420 0.420 0.320 highmast Connection Pending
80 L VMS 24hrs Solar with Raw Power 1KVA 317.180 317.420 0.240 0.140 highmast Connection Pending
91 TMCS 24hrs Only Solar power NA 326.000 325.580 0.420 0.320 HPSV Street Light
98 VASD 6hrs Solar with Raw Power 2kva 330.250 330.600 0.350 0.250 VMS
99 VASD 6hrs Solar with Raw Power 330.260 -330.260
101 TMCS 6hrs Solar with Raw Power 1KVA 331.000 330.600 0.400 0.300 VMS
105 TMCS 6hrs Solar with Raw Power 1KVA 334.000 334.250 0.250 0.150 HPSV Street Light
106 TMCS 6hrs Solar with Raw Power 1KVA 335.000 334.850 0.150 0.050 HPSV Street Light
108 TMCS 24hrs Only Solar power NA 337.000 336.650 0.350 0.350 HPSV Street Light
134 TMCS 24hrs Only Solar power NA 356.000 356.350 0.350 0.250 Highmast
140 TMCS 6hrs Solar with Raw Power 1KVA 359.000 358.750 0.250 0.150 VMS connection Pending
143 VIDES 6hrs Solar with Raw Power 2KVA 360.350 360.570 0.220 0.120 Highmast
144 VIDES 6hrs Solar with Raw Power 360.450 360.570 0.120 0.020 Highmast
145 TMCS 6hrs Solar with Raw Power 2KVA 361.000 360.570 0.430 0.330 Highmast
146 L VMS 24hrs Solar with Raw Power 361.200 361.630 0.430 0.330 Highmast
147 TMCS 6hrs Solar with Raw Power 1KVA 362.000 361.630 0.370 0.270 Highmast
149 TMCS 6hrs Solar with Raw Power 1KVA 364.000 363.650 0.350 0.250 HPSV Street Light
150 TMCS 6hrs Solar with Raw Power 1KVA 365.000 365.450 0.450 0.350 Highmast
155 VASD 6hrs Solar with Raw Power 2kva 369.300 369.650 0.350 0.250 HPSV Street Light
156 VASD 6hrs Solar with Raw Power 369.350 369.650 0.300 0.200 HPSV Street Light
159 TMCS 6hrs Solar with Raw Power 1KVA 371.000 370.700 0.300 0.200 LED Street Light connection Pending
162 L VMS 24hrs Solar with Raw Power 1KVA 373.850 374.080 0.230 0.130 Highmast
163 VIDES 6hrs Solar with Raw Power 2KVA 373.920 374.080 0.160 0.060 Highmast
168 TMCS 24hrs Only Solar power NA 377.000 377.400 0.400 0.300 HPSV Street Light
184 VASD 6hrs Solar with Raw Power 2kva 387.690 388.130 0.440 0.340 HPSV Street Light
185 VASD 6hrs Solar with Raw Power 387.700 388.130 0.430 0.330 HPSV Street Light
186 TMCS 24hrs Only Solar power NA 388.000 388.130 0.130 0.130 HPSV Street Light
188 TMCS 24hrs Only Solar power NA 389.000 389.120 0.120 0.020 ATMS
198 TMCS 24hrs Only Solar power NA 396.000 396.200 0.200 0.200 Highmast
199 L VMS 24hrs Solar with Raw Power 1KVA 396.650 396.200 0.450 0.350 HPSV Street Light
204 TMCS 6hrs Solar with Raw Power 1KVA 401.000 401.450 0.450 0.350 HPSV Street Light
206 TMCS 24hrs Only Solar power NA 403.000 403.400 0.400 0.300 LED Street Light
222 VIDES 6hrs Solar with Raw Power 2KVA 412.270 412.450 0.180 0.080 Highmast
223 VIDES 6hrs Solar with Raw Power 412.300 412.450 0.150 0.050 Highmast
226 L VMS 24hrs Solar with Raw Power 1KVA 413.550 413.850 0.300 0.200 Highmast
230 TMCS 6hrs Solar with Raw Power 1KVA 417.000 416.750 0.250 0.150 NA
231 TMCS 6hrs Solar with Raw Power 1KVA 418.000 417.800 0.200 0.100 NA
232 TMCS 6hrs Solar with Raw Power 419.000 419.150 0.150 0.050 NA
233 L VMS 24hrs Only Solar power 419.000 419.150 0.150 0.050 HPSV Street Light
234 M-VMS 6hrs Solar with Raw Power 5KVA 419.150 419.400 0.250 0.150 VMS
Total Length in Mtr 11400
20 % Exta Length (if the agency is not able to provide cable above 100 Mtr) 2280
Total Cable for ATMS supply 13680
For Both Toll, Trucklay rest room, toilet room & admin Building from main electrical Panel 6320
Total Length of required cable in Mtr 20000
Details for Laying of DWC HDPE Pipe for highway street Light & Toll Plaza
SR NO Equipment Name Chainage Village Name Description Chainage DWC HDPE Pipe 63 mm Remark
1 LED STREET LIGHT 263.000 Kesharpur Truck Lay By Truck Lay By 262.900 263.150 150
2 Highmast 266.620 Faridpur Toll Highmast A1 Side Highmast 266.620 266.820 100
3 Toll Plaza 266.980 Toll Plaza Toll Plaza 266.820 266.980 300
4 Highmast 267.200 Faridpur Toll Toll Highmast A2 Side Highmast 267.100 267.290 20
5 HPSV STREET LIGHT 270.100 Faridpur Bypass Bareilly HPSV STREET LIGHT 269.700 270.350 120
6 Highmast 272.500 Faridpur Tiraha Highmast 272.520 272.520 120
7 HPSV STREET LIGHT 274.170 NEAR GURUDWARA FARIDPUR HPSV STREET LIGHT 273.700 274.450 120
8 HPSV STREET LIGHT 277.750 Faridpur Bareilly Highmast 277.300 278.100 120
9 HPSV STREET LIGHT 282.380 NEELAM VENEER, Tisuwa HPSV STREET LIGHT 282.000 282.800 120
10 HPSV STREET LIGHT 288.200 Uchesiya Mod Fatehganj Purbi Near Gupta Restourent HPSV STREET LIGHT 287.850 288.650 100
11 HPSV STREET LIGHT 289.120 Fatehganj Purbi HPSV STREET LIGHT 288.900 289.500 200
12 HPSV STREET LIGHT 295.370 Katara Chauraha LHS HPSV STREET LIGHT 295.000 295.730 40
13 HPSV STREET LIGHT 295.370 Katara Chauraha RHS HPSV STREET LIGHT 295.000 295.730 40
14 HPSV STREET LIGHT 303.650 Mansoorpur Tilhar Cut HPSV STREET LIGHT 303.250 303.950 150
15 HPSV STREET LIGHT 305.440 Tilahar LHS HPSV STREET LIGHT 305.050 305.900 80
16 HPSV STREET LIGHT 305.410 Tilahar RHS HPSV STREET LIGHT 305.050 305.900 80
17 LED STREET LIGHT 306.100 Tilhar City Rd Truck Lay By Truck Lay By 306.150 306.300 120
18 LED STREET LIGHT 314.640 Street Light HPSV STREET LIGHT 314.300 314.900 160
19 HPSV STREET LIGHT 315.750 Banthara HPSV STREET LIGHT 315.350 316.000 100
20 HPSV STREET LIGHT 325.580 Bareilly Mod LHS HPSV STREET LIGHT 325.100 326.000 100
21 HPSV STREET LIGHT 325.630 Bareilly Mod RHS HPSV STREET LIGHT 100
22 HPSV STREET LIGHT 329.560 Near BHARAT DHABA BRIDGE LHS HPSV STREET LIGHT 329.100 330.000 100
23 HPSV STREET LIGHT 329.560 Roza Bypass RHS HPSV STREET LIGHT 329.100 330.000 80
24 HPSV STREET LIGHT 334.250 ROB RAILWAY CROSSING, LHS Highmast 334.250 334.650 300 From Transfor to VUP
25 LED STREET LIGHT 348.600 Truck Lay By Truck Lay By 348.450 348.700 510
26 HPSV STREET LIGHT 358.050 Barkheriya Jat HPSV STREET LIGHT 357.600 358.450 150
27 HPSV STREET LIGHT 363.650 Highmast RHS HPSV STREET LIGHT 363.400 363.950 150
28 HPSV STREET LIGHT 370.100 Chhapartala HPSV STREET LIGHT 369.650 370.700 180
29 LED STREET LIGHT 370.700 Truck Lay By Truck Lay By 370.700 371.700 270
30 Toll Plaza 372.100 Toll Plaza Maigalganj Toll Plaza 372.020 372.180 300
31 HPSV STREET LIGHT 377.400 Aurangabad / Maigalganj Bypass HPSV STREET LIGHT 376.800 378.000 150
32 LED STREET LIGHT 382.750 Truck Lay By Truck Lay By 382.450 382.700 150
33 HPSV STREET LIGHT 383.650 Neri, Maholi HPSV STREET LIGHT 383.200 384.200 150
34 HPSV STREET LIGHT 388.130 Bhudiya PO Kachuri, Sitapur HPSV STREET LIGHT 387.800 388.600 150
35 HPSV STREET LIGHT 392.470 Badagaon Maholi HPSV STREET LIGHT 391.900 393.000 150
36 HPSV STREET LIGHT 401.450 RICHHAI CHAURAHA HPSV STREET LIGHT 401.100 402.000 150
37 LED STREET LIGHT 403.400 Hempur ROB RHS LED STREET LIGHT 402.600 404.000 150
38 LED STREET LIGHT 403.650 Hempur ROB LHS LED STREET LIGHT 402.600 404.000 150
39 LED STREET LIGHT 413.850 Naveen Chowk, OVER BRIDGE LED STREET LIGHT 413.830 413.830 150
40 LED STREET LIGHT 416.750 ROTI GODAM KANWAKHEDA LED STREET LIGHT 416.340 417.060 130
41 HPSV STREET LIGHT 417.800 Bahuguda Chauraha Bridge LED STREET LIGHT 417.350 418.050 120
42 HPSV STREET LIGHT 418.700 kamta sariya-1 HPSV STREET LIGHT 418.050 418.750 120
43 HPSV STREET LIGHT 418.700 kamta sariya-2 HPSV STREET LIGHT 418.750 419.350 120
DWC HDPE PIPE 100 mm Dia (OD-100 mm & ID-90 mm nominal)
SR NO Equipment Name Chainage Qty Remark
1 Street Light & Highmast 270.000 45 It has been considered to lay a 100 mm dia. HDPE pipe from the ROW Main Feeder Pillar to the median of the VUP for the street lighting cable.
2 Street Light & Highmast 274.170 45
3 Street Light & Highmast 277.660 45
4 Street Light & Highmast 282.380 45
5 Street Light & Highmast 288.200 45
6 Street Light 289.120 45
7 Street Light 290.600 45
8 Street Light 314.640 45
9 Street Light & Highmast 315.000 45
10 Street Light & Highmast 334.250 100
11 Street Light & Highmast 336.650 50
12 Street Light 348.600 45
13 Street Light & Highmast 358.050 45
14 Highmast 361.600 45
15 Street Light & Highmast 363.650 45
16 Highmast 365.450 45
17 Street Light & Highmast 370.100 45
18 LED STREET LIGHT 370.700 45
19 Highmast 372.350 45
20 HPSV STREET LIGHT 377.350 45
21 LED STREET LIGHT 382.750 45
22 HPSV STREET LIGHT 383.650 45
23 HPSV STREET LIGHT 388.130 45
24 HPSV STREET LIGHT 392.470 45
25 HPSV STREET LIGHT 396.200 45
26 HPSV STREET LIGHT 396.200 45
27 HPSV STREET LIGHT 401.450 45
28 LED STREET LIGHT 403.400 45
29 HPSV STREET LIGHT 407.600 45
30 LED STREET LIGHT 413.900 45
31 HPSV STREET LIGHT 417.800 45
32 HPSV STREET LIGHT 418.750 45
Location for Providing & Laying of Aluminium Armoured Cable for Highway street Light, ATMS & Toll plaza Cable Renovation
SR NO Equipment Name Chainage Village Name Description Chainage Total no of Pole Total No of Fixture Al. Armoured cable 4X16 Sq , mm for pole to Cable replacement Al. Armoured cable 4X25 Sq , mm from Feeder Pillar to First Pole & Cable renovation at Toll Plaza Al. Armoured cable 4X35 Sq , mm from Transformer to Fedder Pillar or as per site requirement(For Heavy Load) Al. Armoured cable 3.5X50 Sq , mm from Transformer to Fedder Pillar Al. Armoured cable 3.5X70 Sq , mm from Transformer to Fedder Pillar Remark
From To Length in Mtr
1 LED STREET LIGHT 263.000 Kesharpur Truck Lay By Truck Lay By 262.900 263.150 250 8 8 270 70 Over head cable installed at side for street light & Required to Replace the existing overhead unarmoured cable with a suitably rated underground cable due to inadequate load-carrying capacity.
2 Highmast 266.620 Faridpur Toll Highmast A1 Side Highmast 266.620 266.820 200 0 0 150 30 In Place of damaged cable replacement
3 Toll Plaza 266.980 Toll Plaza Toll Plaza 266.820 266.980 160 0 0 5000 Cable required at the toll plaza for renovation work, as per the connected load and site conditions.
4 Highmast 267.200 Faridpur Toll Toll Highmast A2 Side Highmast 267.100 267.290 190 0 0 20 30 In Place of damaged cable replacement
5 Highmast 268.150 Gausganj Sarai near Khandelwal Oils Highmast 268.150 268.150 0 0 0 30
6 HPSV STREET LIGHT 270.100 Faridpur Bypass Bareilly HPSV STREET LIGHT 269.700 270.350 650 26 52 120 30 In Place of damaged cable replacement
7 Highmast 272.500 Faridpur Tiraha Highmast 272.520 272.520 0 0 0 120 30 In Place of damaged cable replacement
8 HPSV STREET LIGHT 274.170 NEAR GURUDWARA FARIDPUR HPSV STREET LIGHT 273.700 274.450 750 28 56 120 30 In Place of damaged cable replacement
9 HPSV STREET LIGHT 277.750 Faridpur Bareilly Highmast 277.300 278.100 800 28 56 120 30 30 In Place of damaged cable replacement
10 HPSV STREET LIGHT 282.380 NEELAM VENEER, Tisuwa HPSV STREET LIGHT 282.000 282.800 800 29 58 120 180 30 In Place of damaged cable replacement
11 HPSV STREET LIGHT 288.200 Uchesiya Mod Fatehganj Purbi Near Gupta Restourent HPSV STREET LIGHT 287.850 288.650 800 29 58 120 60 30 In Place of damaged cable replacement
12 HPSV STREET LIGHT 289.120 Fatehganj Purbi HPSV STREET LIGHT 288.900 289.500 600 22 44 240 60 30 In Place of damaged cable replacement
13 LED STREET LIGHT 290.600 Shalpur Navdia ROB HPSV STREET LIGHT 290.050 291.350 1300 167 167 5040 260 30 The existing unarmoured cables installed between the poles are incapable of carrying the electrical load of the street lights.
14 HPSV STREET LIGHT 295.370 Katara Chauraha LHS HPSV STREET LIGHT 295.000 295.730 730 30 60 30 60 130 In Place of damaged cable replacement
15 HPSV STREET LIGHT 295.370 Katara Chauraha RHS HPSV STREET LIGHT 295.000 295.730 730 30 60 30 60 150 In Place of damaged cable replacement
16 HPSV STREET LIGHT 303.650 Mansoorpur Tilhar Cut HPSV STREET LIGHT 303.250 303.950 700 26 52 210 30
17 HPSV STREET LIGHT 305.440 Tilahar LHS HPSV STREET LIGHT 305.050 305.900 850 37 74 60 60 100 30
18 HPSV STREET LIGHT 305.410 Tilahar RHS HPSV STREET LIGHT 305.050 305.900 850 37 74 60 60 120 30
19 LED STREET LIGHT 306.100 Tilhar City Rd Truck Lay By Truck Lay By 306.150 306.300 150 8 8 270 70 Over head cable installed at side for street light & Required to Replace the existing overhead unarmoured cable with a suitably rated underground cable due to inadequate load-carrying capacity.
20 Highmast 307.000 Highmast 307.000 307.000 0 0 0
21 LED STREET LIGHT 314.640 Street Light HPSV STREET LIGHT 314.300 314.900 600 36 72 2190 180 The existing unarmoured cables installed between the poles are incapable of carrying the electrical load of the street lights.
22 HPSV STREET LIGHT 315.750 Banthara HPSV STREET LIGHT 315.350 316.000 650 58 116 60 140 50
23 Highmast 317.420 HIGHMAST LHS Highmast 317.420 317.420 0 0 0 30 For replacement of service cable from the transformer to to the feeder pillar to prevent overheating.
24 HPSV STREET LIGHT 325.580 Bareilly Mod LHS HPSV STREET LIGHT 325.100 326.000 900 32 64 60 100 30
25 HPSV STREET LIGHT 325.630 Bareilly Mod RHS HPSV STREET LIGHT 30 60 60 100 30
26 HPSV STREET LIGHT 329.560 Near BHARAT DHABA BRIDGE LHS HPSV STREET LIGHT 329.100 330.000 900 34 68 60 100 30
27 HPSV STREET LIGHT 329.560 Roza Bypass RHS HPSV STREET LIGHT 329.100 330.000 900 35 70 60 100 30
28 Highmast 331.700 Roza Bypass RHS Highmast 331.700 331.700 0 0 0 60 For replacement of service cable from the transformer to to the feeder pillar to prevent overheating.
29 HPSV STREET LIGHT 331.950 NEAR DOON SCHOOL LHS, Ahmadpur Niwazpur HPSV STREET LIGHT 331.600 332.050 450 17 34 20 30
30 HPSV STREET LIGHT 331.950 NEAR DOON SCHOOL RHS Ahmadpur Niwazpur HPSV STREET LIGHT 331.600 332.050 450 16 32 20 30
31 HPSV STREET LIGHT 332.250 Honda Colony, Roza - 2 LHS Mandi Marg HPSV STREET LIGHT 332.050 332.500 450 16 32 20 30
32 HPSV STREET LIGHT 332.250 Kuda Plant, Roza -1 RHS Mandi Marg HPSV STREET LIGHT 332.050 332.500 450 17 34
33 HPSV STREET LIGHT 334.250 ROB RAILWAY CROSSING, LHS HPSV STREET LIGHT 333.700 334.900 1200 70 140
34 Highmast 334.900 ROB RAILWAY CROSSING, LHS Highmast 334.900 334.900 0 0 0 30 For replacement of service cable from the transformer to to the feeder pillar to prevent overheating.
35 HPSV STREET LIGHT 336.650 Jamuhi, Shajahanpur Rd HPSV STREET LIGHT 336.300 337.100 800 66 132 220 30
36 LED STREET LIGHT 348.600 Truck Lay By Truck Lay By 348.450 348.700 250 16 16 510 200 170 Over head cable installed at side for street light & Required to Replace the existing overhead unarmoured cable with a suitably rated underground cable due to inadequate load-carrying capacity.
37 Highmast 356.350 PANAI CHAURAHA Highmast 356.350 356.350 0 0 0 50 30 For replacement of service cable from the transformer to to the feeder pillar to prevent overheating.
38 HPSV STREET LIGHT 358.050 Barkheriya Jat HPSV STREET LIGHT 357.600 358.450 850 33 66 90 30
39 Highmast 360.570 Udaypur, JB Ganj Highmast 360.570 360.570 0 0 0 30 For replacement of service cable from the transformer to to the feeder pillar to prevent overheating.
40 Highmast 361.630 Highmast BHS Highmast 361.600 361.600 0 0 0 30
41 HPSV STREET LIGHT 363.650 Highmast RHS HPSV STREET LIGHT 363.400 363.950 550 21 42 90 30
42 Highmast 365.450 Pihani Mod Highmast 365.450 365.450 0 0 0 30
43 HPSV STREET LIGHT 370.100 Chhapartala HPSV STREET LIGHT 369.650 370.700 1050 43 86 180 190 30
44 LED STREET LIGHT 370.700 Truck Lay By Truck Lay By 370.700 371.700 1000 8 8 270 70 Over head cable installed at side for street light & Required to Replace the existing overhead unarmoured cable with a suitably rated underground cable due to inadequate load-carrying capacity.
45 Highmast 372.100 Aurangabad Khiri Highmast 371.750 371.920 170 0 0 30
46 Toll Plaza 372.100 Toll Plaza Maigalganj Toll Plaza 372.020 372.180 160 0 0 5000 Cable required at the toll plaza for renovation work, as per the connected load and site conditions.
47 Highmast 372.350 Maigalganj Toll, Highmast Sitapur Side Highmast 372.260 372.480 220 0 0 120 30 For replacement of service cable from the transformer to to the feeder pillar to prevent overheating.
48 Highmast 374.080 Rahjaniya, Maigalganj Highmast 374.080 374.080 0 0 0
49 HPSV STREET LIGHT 377.400 Aurangabad / Maigalganj Bypass HPSV STREET LIGHT 376.800 378.000 1200 45 90 120 170 30
50 Highmast 380.050 Highmast RHS Highmast 380.050 380.050 0 0 0 60 For replacement of service cable from the transformer to to the feeder pillar to prevent overheating.
51 LED STREET LIGHT 382.750 Truck Lay By Truck Lay By 382.450 382.700 250 8 8 270 70 Over head cable installed at side for street light & Required to Replace the existing overhead unarmoured cable with a suitably rated underground cable due to inadequate load-carrying capacity.
52 HPSV STREET LIGHT 383.650 Neri, Maholi HPSV STREET LIGHT 383.200 384.200 1000 42 84 120 30 In Place of damaged cable replacement
53 HPSV STREET LIGHT 388.130 Bhudiya PO Kachuri, Sitapur HPSV STREET LIGHT 387.800 388.600 800 32 64 120 30 In Place of damaged cable replacement
54 HPSV STREET LIGHT 392.470 Badagaon Maholi HPSV STREET LIGHT 391.900 393.000 1100 41 82 120 30 In Place of damaged cable replacement
55 Highmast 395.550 Maholi, Sitapur Highmast 395.000 395.000 0 0 0
56 HPSV STREET LIGHT 396.200 Maholi LHS HPSV STREET LIGHT 395.750 396.600 850 32 64 30
57 HPSV STREET LIGHT 396.200 Maholi RHS HPSV STREET LIGHT 395.750 396.600 850 32 64 30
58 HPSV STREET LIGHT 401.450 RICHHAI CHAURAHA HPSV STREET LIGHT 401.100 402.000 900 35 70 120 200 30 In Place of damaged cable replacement
59 LED STREET LIGHT 403.400 Hempur ROB RHS LED STREET LIGHT 402.600 404.000 1400 59 118 3570 170 30 The existing unarmoured cables installed between the poles are incapable of carrying the electrical load of the street lights.
60 LED STREET LIGHT 403.650 Hempur ROB LHS LED STREET LIGHT 402.600 404.000 1400 59 118 3570 140 30 The existing unarmoured cables installed between the poles are incapable of carrying the electrical load of the street lights.
61 Highmast 403.570 Hempur Highmast Highmast 403.570 403.570 0 0 0
62 HPSV STREET LIGHT 407.570 Katili Bridge LHS HPSV STREET LIGHT 407.290 408.000 710 27 54 100 30 In Place of damaged cable replacement
63 HPSV STREET LIGHT 407.000 PAPER MILL BRIDGE II, KATILI RHS HPSV STREET LIGHT 407.290 408.000 710 28 56 120 30 In Place of damaged cable replacement
64 Highmast 412.450 Kashiram Colony, Sitapur Highmast 412.450 412.450 0 0 0 30 For replacement of service cable from the transformer to to the feeder pillar to prevent overheating.
65 LED STREET LIGHT 413.850 Naveen Chowk, OVER BRIDGE LED STREET LIGHT 413.830 413.830 0 30 60 1830 140 30 The existing unarmoured cables installed between the poles are incapable of carrying the electrical load of the street lights.
66 Highmast 413.900 Naveen Chowk Highmast Highmast 413.830 413.830 0 0 0 30 For replacement of service cable from the transformer to to the feeder pillar to prevent overheating.
67 LED STREET LIGHT 416.750 ROTI GODAM KANWAKHEDA LED STREET LIGHT 416.340 417.060 720 58 116 3510 200 30 The existing unarmoured cables installed between the poles are incapable of carrying the electrical load of the street lights.
68 HPSV STREET LIGHT 417.800 Bahuguda Chauraha Bridge LED STREET LIGHT 417.350 418.050 700 26 52 120 30 In Place of damaged cable replacement
69 Highmast 417.800 Lal Kurti Road, Sitapur LED STREET LIGHT 417.800 417.800 0 0 0 120 30 30 For replacement of service cable from the transformer to to the feeder pillar to prevent overheating.
70 HPSV STREET LIGHT 418.700 kamta sariya-1 HPSV STREET LIGHT 418.050 418.750 700 26 52 120 30 In Place of damaged cable replacement
71 HPSV STREET LIGHT 418.700 kamta sariya-2 HPSV STREET LIGHT 418.750 419.350 600 28 56 120 30 In Place of damaged cable replacement
Details for Laying of DWC HDPE Pipe for ATMS supply, Toll Electrical
Sr No Equipment Backup Power Source ATMS Location Location of Existing Connection DWC HDPE Pipe 63 mm in Mtr Existing Connection taken for the Equipment Status Remark
M/O HDD Location
1 TMCS 6hrs Solar with Raw Power 263.200 263.000 100 LED Street Light Cable Provide The cable laying work for ATMS equipment falls under the scope of the ATMS agency. The fixed distance under the agency’s scope has not yet been finalized. As per the email received from the agency and the instructions from our ATMS team, a length of 100 meters has been considered as fixed under the agency’s scope. Based on this, the average cable length has been calculated for the balance length, which will fall under the scope of NHIT, while at the same locations, 100 meters of cable length will remain under the agency’s scope.
2 TMCS 6hrs Solar with Raw Power 268.000 268.150 50 Highmast Cable Provide 268.130
3 TMCS 6hrs Solar with Raw Power 274.000 274.170 70 HPSV Street Light Cable Provide
4 TMCS 6hrs Solar with Raw Power 278.000 277.750 150 HPSV Street Light Cable Provide
5 TMCS 6hrs Solar with Raw Power 282.000 282.380 280 HPSV Street Light Cable Provide
6 TMCS 24hrs Only Solar power 286.000 286.300 300 VMS Cable Provide
7 L VMS 24hrs Solar with Raw Power 286.650 286.300 250 VMS Cable Provide
8 TMCS 6hrs Solar with Raw Power 288.000 288.200 100 HPSV Street Light Cable Provide
9 TMCS 6hrs Solar with Raw Power 289.000 289.120 20 HPSV Street Light Cable Provide
10 TMCS 6hrs Solar with Raw Power 290.000 289.730 170 New Proposed VADS Cable Provide
11 TMCS 6hrs Solar with Raw Power 291.000 290.600 300 LED Street Light Cable Provide
12 L VMS 24hrs Solar with Raw Power 294.550 294.400 50 VIDS/PTZ Camera Cable Provide
13 TMCS 6hrs Solar with Raw Power 295.000 295.370 270 HPSV Street Light Cable Provide
14 TMCS 6hrs Solar with Raw Power 303.200 303.650 350 HPSV Street Light Cable Provide
15 TMCS 6hrs Solar with Raw Power 304.000 303.650 250 HPSV Street Light Cable Provide
16 TMCS 6hrs Solar with Raw Power 305.000 305.440 340 HPSV Street Light Cable Provide
17 TMCS 24hrs Only Solar power 309.000 309.200 200 VMS OK
18 VASD 6hrs Solar with Raw Power 309.400 309.200 100 VMS Cable Provide
19 VASD 6hrs Solar with Raw Power 309.410 309.200 110 VMS Cable Provide
20 TMCS 24hrs Only Solar power 317.000 317.420 320 Camera Pending Cable Provide
21 L VMS 24hrs Solar with Raw Power 317.180 317.420 140 highmast Connection Pending Cable Provide 317.430
23 VASD 6hrs Solar with Raw Power 330.250 330.600 250 VMS Cable Provide 330.400
24 VASD 6hrs Solar with Raw Power 330.260 0
25 TMCS 6hrs Solar with Raw Power 331.000 330.600 300 VMS Cable Provide
26 TMCS 6hrs Solar with Raw Power 334.000 334.250 150 HPSV Street Light Cable Provide
27 TMCS 6hrs Solar with Raw Power 335.000 334.850 50 HPSV Street Light Cable Provide
30 TMCS 6hrs Solar with Raw Power 359.000 358.750 150 VMS connection Pending
31 VIDES 6hrs Solar with Raw Power 360.350 360.570 120 Highmast Cable Provide
32 VIDES 6hrs Solar with Raw Power 360.450 360.570 20 Highmast Cable Provide 360.410
33 TMCS 6hrs Solar with Raw Power 361.000 360.570 330 Highmast Cable Provide 360.450
34 L VMS 24hrs Solar with Raw Power 361.200 361.630 330 Highmast Cable Provide
35 TMCS 6hrs Solar with Raw Power 362.000 361.630 270 Highmast Cable Provide
36 TMCS 6hrs Solar with Raw Power 364.000 363.650 250 HPSV Street Light Cable Provide
37 TMCS 6hrs Solar with Raw Power 365.000 365.450 350 Highmast Cable Provide
38 VASD 6hrs Solar with Raw Power 369.300 369.650 250 HPSV Street Light Cable Provide
39 VASD 6hrs Solar with Raw Power 369.350 369.650 200 HPSV Street Light Cable Provide
40 TMCS 6hrs Solar with Raw Power 371.000 370.700 200 LED Street Light connection Pending Cable Provide 370.800
41 L VMS 24hrs Solar with Raw Power 373.850 374.080 130 Highmast Cable Provide
42 VIDES 6hrs Solar with Raw Power 373.920 374.080 60 Highmast Cable Provide 373.950
44 VASD 6hrs Solar with Raw Power 387.690 388.130 340 HPSV Street Light Cable Provide 387.100
45 VASD 6hrs Solar with Raw Power 387.700 388.130 330 HPSV Street Light
49 L VMS 24hrs Solar with Raw Power 396.650 396.200 350 HPSV Street Light Cable Provide
50 TMCS 6hrs Solar with Raw Power 401.000 401.450 350 HPSV Street Light Cable Provide
52 VIDES 6hrs Solar with Raw Power 412.270 412.450 80 Highmast Cable Provide 412.270
53 VIDES 6hrs Solar with Raw Power 412.300 412.450 50 Highmast Cable Provide
54 L VMS 24hrs Solar with Raw Power 413.550 413.850 200 Highmast Cable Provide
55 TMCS 6hrs Solar with Raw Power 417.000 416.750 150 NA Cable Provide
56 TMCS 6hrs Solar with Raw Power 418.000 417.800 100 NA Cable Provide
57 TMCS 6hrs Solar with Raw Power 419.000 419.150 50 NA Cable Provide
58 L VMS 24hrs Only Solar power 419.000 419.150 50 HPSV Street Light Cable Provide
59 M-VMS 6hrs Solar with Raw Power 419.150 419.400 150 VMS
Total Length in Mtr 9530
20 % Exta Lenght (if the agency is not able to provide cable above 100 Mtr) 1906
Total length for Laying of DWC HDPE Pipe for highway street Light & Toll Plaza 6320
spare if any require at any Location 1094
Total Sum 18850
HDD Work With 100 mm Dia PN6-8 grade HDPE Pipe for Toll plaza cable renovation work
SR NO Chainage HDD work Required for Chainage HDD Work with 100 mm HDPE Pipe in Mtr Remark
1 Faridpur For weigh bridge 266.580 LHS 266.580 RHS 40 With BHS electrical Chamber 268.130
2 For Highmast & Weigh 266.580 LHS 266.790 LHS 240 without Chamber
3 Highmast Supply 266.760 LHS 266.760 RHS 100 For damaged Cable replacement
4 Toll building & Tunel Supply Electrical Building admin building near Tunel 320 The laying is to be carried out from chamber to chamber at intervals of 30–35 meters. With 2 set Pipe
5 For RHS TMS equipment 266.920 LHS 266.920 RHS 220 For Spare supply cable laying for RHS with both side chamber in Set Resuced in PR
6 Highmast Supply 267.020 LHS 267.020 LHS 80 With BHS electrical Chamber
7 Maigalganj For weigh bridge 371.740 LHS 371.740 RHS 40 With BHS electrical Chamber
8 For Highmast & Weigh 371.740 LHS 371.960 LHS 240 without Chamber
9 Highmast Supply 371.935 LHS 371.935 RHS 100 For damaged Cable replacement
10 Toll building & Tunel Supply Electrical Building admin building near Tunel 320 The laying is to be carried out from chamber to chamber at intervals of 30–35 meters. With 2 set Pipe
11 For RHS TMS equipment 372.120 LHS 372.120 RHS 220 For Spare supply cable laying for RHS with both side chamber in Set Resuced in PR
12 Highmast Supply 372.360 LHS 372.360 RHS 80 With BHS electrical Chamber
HDD Work With 100 mm Dia PN6-8 grade HDPE Pipe for ATMs & Electrical Damaged cable replacement at site
SR NO Chainage HDD work Required for Chainage HDPE Pipe Size HDD Work with 63 mm HDPE Pipe in Mtr Remark
4 334.250 For street Light Panel LHS RHS 100 mm 250
5 348.600 For LED street Light 348.450 348.700 63mm 150
11 377.400 For Highmast Supply Median RHS 63mm 40
392.700 For Highmast Supply RHS LHS 100mm 100
12 407+650 For street Light LHS Median 63mm 40
13 407+650 For Highmast Supply LHS RHS 63mm 90
Total SUM 1000 500 Mtr reduced from Pr of ATMS
Construction of Electrical Chamber for Both Toll Plaza from Electrical Building to near Tunel of Admin Building
SR NO Chainage Toll Plaza name Location Chainage Qty in No's Remark
1 266.620 Faridpur For Highmast & Weigh Bridge LHS ROW RHS ROW 2 The chamber will be constructed after the HDD work is completed.
2 266.980 Toll Spare Supply LHS ROW RHS ROW 2 The chamber will be constructed after the HDD work is completed.
266.980 for 11 KVA supllly VCB/HT Meter room electrical building 2 The chamber will be constructed during the laying of HDPE pipe.
3 266.980 Faridpur Toll Plaza building & Tunnel Supply Electrical Building Near Tunel 8 The chamber will be constructed during the laying of HDPE pipe.
4 267.200 For Highmast LHS ROW RHS ROW 2 The chamber will be constructed after the HDD work is completed.
5 372.100 Maigalganj For Highmast & Weigh Bridge LHS ROW RHS ROW 2 The chamber will be constructed after the HDD work is completed.
6 372.100 Toll Spare Supply LHS ROW RHS ROW 2 The chamber will be constructed after the HDD work is completed.
for 11 KVA supllly VCB/HT Meter room electrical building 2 The chamber will be constructed during the laying of HDPE pipe.
7 372.100 Maigalganj Toll Plaza building & Tunnel Supply Electrical Building Near Tunel 8 The chamber will be constructed during the laying of HDPE pipe.
8 372.350 For Highmast LHS ROW RHS ROW 2 The chamber will be constructed after the HDD work is completed.
Details of Earthing for Street Light Pole, Highmast Pole, Fedder pillar, & Highmast Panel
SR NO Equipment Name Chainage Village Name Description Chainage Total No of Pole Total no of Highmast Earthing Qty. for street Light Earthing Qty. Street Light feeder & Panel Panel Earthing Qty. for Highmast Pole Earthing Qty. for Highmast Panel 8 Swg GI Wire Pole to Pole Length in Mtr 8 Swg GI Wire from Feeder Pillar to First Pole Length in Mtr Remark
From To Length in Mtr
1 LED STREET LIGHT 262.900 Kesharpur Truck Lay By Truck Lay by 262.900 263.150 250 8 0 1 1 0 0 Avg considered
2 Highmast 266.620 Faridpur Toll Highmast A1 Side Toll Plaza Permises 266.620 266.820 200 0 4 0 1 4 1
3 Toll Plaza 266.980 Toll Plaza Faridpur Toll Plaza 266.820 266.980 160 0 4 0 1 4 1
4 Highmast 267.160 Faridpur Toll Toll Highmast A2 Side Toll Plaza Permises 267.100 267.290 190 0 4 0 1 4 1
5 Highmast 268.150 Gausganj Sarai near Khandelwal Oils Junction RHS 268.150 268.150 0 0 1 0 1 1 1
6 HPSV STREET LIGHT 270.000 Faridpur Bypass Bareilly Flyover/VUP 269.700 270.350 650 26 2 3 2 2 2 675 40
7 Highmast 272.500 Kshatripati Shiva Ji inter collage Junction RHS 272.520 272.520 0 0 1 0 1 1 1
8 HPSV STREET LIGHT 274.170 NEAR GURUDWARA FARIDPUR Flyover/VUP 273.700 274.450 750 28 1 3 2 1 1 725 50
9 HPSV STREET LIGHT 277.660 Faridpur Bareilly Flyover/VUP 277.300 278.100 800 28 2 3 2 2 2 725 40
10 HPSV STREET LIGHT 282.380 NEELAM VENEER, Stiswa Flyover/VUP 282.000 282.800 800 29 2 3 2 2 2 750 50
11 HPSV STREET LIGHT 288.200 Uchesiya Mod Fatehganj Purbi Near Gupta Restourent Flyover/VUP 287.850 288.650 800 29 2 3 2 2 2 750 40
12 HPSV STREET LIGHT 289.120 Fatehganj Purbi Flyover/VUP 288.900 289.500 600 22 0 2 2 0 0 575 50
13 LED STREET LIGHT 290.600 Shalpur Navdia ROB Flyover/ROB 290.050 291.350 1300 166 0 11 1 0 0
14 HPSV STREET LIGHT 295.370 Katara Flyover/VUP 295.000 295.730 730 60 2 5 2 2 2 1525 50
15 HPSV STREET LIGHT 303.650 Mansoorpur Tilhar Cut Flyover/VUP 303.250 303.950 700 26 1 3 2 1 1 675 50
16 HPSV STREET LIGHT 305.410 Tilahar BHS Flyover/VUP 305.050 305.900 850 74 2 7 2 2 2 1875 50
17 LED STREET LIGHT 306.100 Tilhar City Rd Truck Lay By Truck Lay by 306.150 306.300 150 8 0 1 1 0 0
18 Highmast 307.000 Junction RHS 307.000 307.000 0 0 1 0 1 1 1
19 LED STREET LIGHT 314.640 Street Light Flyover/VUP 314.300 314.900 600 36 0 4 1 0 0
20 HPSV STREET LIGHT 315.750 Banthara Flyover/VUP 315.350 316.000 650 58 2 6 2 2 2 1475 50
21 Highmast 317.420 HIGHMAST LHS Junction LHS 317.420 317.420 0 0 1 0 1 1 1
22 HPSV STREET LIGHT 325.580 Bareilly Mod BHS Flyover/VUP 325.100 326.000 900 62 2 6 2 2 2 1575 50
23 HPSV STREET LIGHT 329.560 Near BHARAT DHABA BRIDGE BHS Flyover/VUP 329.100 330.000 900 69 2 6 2 2 2 1750 40
24 Highmast 331.700 ATSALIYA LHS Junction RHS 334.900 334.900 0 0 1 0 1 1 1
25 HPSV STREET LIGHT 331.950 NEAR DOON SCHOOL BHS, Ahmadpur Niwazpur Flyover/VUP 331.600 332.500 900 66 4 6 4 4 4 1675 50
26 HPSV STREET LIGHT 334.250 ROB RAILWAY CROSSING, LHS Flyover/ROB 333.700 334.900 1200 70 1 6 2 1 1 1775 50
27 Highmast 334.900 Junction LHS 334.900 334.900 1 0 1 1 1
28 HPSV STREET LIGHT 336.650 Jamuhi, Shajahanpur Rd Flyover/VUP 336.300 337.100 800 66 1 6 1 1 1 1675 25
29 LED STREET LIGHT 348.600 Uncholia,, Gurudwara Truck Lay by 348.450 348.700 250 16 0 2 1 0 0
30 Highmast 356.350 PANAI CHAURAHA Junction RHS 356.350 356.350 0 0 1 0 1 1 1
31 HPSV STREET LIGHT 358.050 Barkheriya Jat Flyover/VUP 357.600 358.450 850 33 2 4 2 2 2 850 50
32 Highmast 360.570 Udaypur, JB Ganj Khad Godam Junction RHS 360.570 360.570 0 0 1 0 1 1 1
33 Highmast 361.600 Highmast BHS Flyover/VUP 361.600 361.600 0 0 2 0 1 2 2
34 HPSV STREET LIGHT 363.650 Hariyali mod Flyover/VUP 363.400 363.950 550 21 2 2 2 2 1 550 50
35 Highmast 365.450 Pihani Mod Flyover/VUP 365.450 365.450 0 0 2 0 1 2 1
36 HPSV STREET LIGHT 370.100 Chapartala, Near Toll Flyover/VUP 369.650 370.700 1050 43 2 5 2 2 1 1100 40
37 LED STREET LIGHT 370.700 Chapartala, Near Toll Truck Lay by 370.700 371.700 1000 8 0 1 1 0 0
38 Highmast 372.100 Aurangabad Khiri Toll Plaza Permises 371.750 371.920 170 0 4 0 1 4 1
39 Toll Plaza 372.100 Toll Plaza Maigalganj Maigalganj Toll Plaza 372.020 372.180 160 0 4 0 1 4 1
40 Highmast 372.350 Maigalganj Toll, Highmast Sitapur Side Toll Plaza Permises 372.260 372.480 220 0 4 0 1 4 1
41 Highmast 374.080 Rahjaniya, Maigalganj Junction RHS 374.080 374.080 0 0 1 0 1 1 1
42 HPSV STREET LIGHT 377.350 Aurangabad / Maigalganj Bypass Flyover/VUP 376.800 378.000 1200 45 2 5 2 2 1 1150 40
43 Highmast 380.050 Highmast RHS Junction RHS 380.050 380.050 0 0 1 0 1 1 1
44 LED STREET LIGHT 382.750 Truck Lay By Truck Lay By 382.450 382.700 250 8 0 1 1 0 0
45 HPSV STREET LIGHT 383.650 Neri, Maholi Flyover/VUP 383.200 384.200 1000 42 2 5 2 2 1 1075 50
46 HPSV STREET LIGHT 388.130 Bhudiya PO Kachuri, Sitapur Flyover/VUP 387.800 388.600 800 32 2 4 2 2 1 825 40
47 HPSV STREET LIGHT 392.470 Badagaon Maholi Flyover/VUP 391.900 393.000 1100 41 2 5 2 2 1 1050 50
48 Highmast 395.550 Maholi, Sitapur Junction RHS 395.550 395.550 0 0 1 0 1 1 1
49 HPSV STREET LIGHT 396.200 Maholi BHS Flyover/VUP 395.750 396.600 850 64 1 6 2 1 1 1625 40
50 HPSV STREET LIGHT 401.450 Street Light MEDIAN Flyover/VUP 401.100 402.000 900 35 2 4 2 2 1 900 50
51 LED STREET LIGHT 403.400 Hempur ROB RHS ROB 402.600 404.000 1400 118 8 1 0 0
52 Highmast 403.570 Hempur Highmast Junction RHS 403.570 403.570 0 0 1 0 1 1 1
53 HPSV STREET LIGHT 407.600 Katili Bridge BHS Flyover/VUP 407.290 408.000 710 55 2 6 2 2 1 1400 40
54 Highmast 412.450 Kashiram Colony, Sitapur Junction LHS 412.450 412.450 0 0 1 0 1 1 1
55 LED STREET LIGHT 413.830 Naveen Chowk, VUP VOP 413.830 413.830 0 30 3 1 0 0
56 Highmast 413.900 Naveen Chowk Highmast Junction LHS 413.830 413.830 0 0 1 0 1 1 1
57 LED STREET LIGHT 416.650 Bahuguda Chauraha Bridge Flyover/VUP 416.340 417.060 720 58 0 6 1 0 0
58 HPSV STREET LIGHT 417.800 kamta sariya-1 Flyover/VUP 417.350 418.350 1000 40 2 4 2 2 1 1025 50
59 HPSV STREET LIGHT 418.750 kamta sariya-2 Flyover/VUP 418.350 419.350 1000 40 1 4 2 1 1 1025 40
Total no of Earthing for Street Light Pole, Highmast Pole, Fedder pillar, & Highmast Panel 400 32000
Earthing Work at Both Toll Plaza
SR NO Location Earthing Eaquipment Name Type of earthing Qty of GI Earthing in No's Qty of Cu Earthing in No's Qty of GI Strip in Mtr Qty of Cu Strip in Mtr Qty of Cu insulated Cable 70 Sq mm in Mtr Qty of Cu insulated Wire 4 Sq mm in Mtr GI wire Remark
1 Faridpur Toll Plaza Transformer Neautral earthing Earthing Copper Chemical Electrode 1 15
2 Faridpur Toll Plaza Transformer Body earthing Earthing GI Chemical Electrode 2 30
3 Faridpur Toll Plaza Cubical Energy Meter Body Earthing GI Chemical Electrode 2 30
4 Faridpur Toll Plaza 11 KVA VCB Panel Panel Body Earthing GI Chemical Electrode 2 30
5 Faridpur Toll Plaza 250 KVA Stabilizer Body Earthing GI Chemical Electrode 1 15
6 Faridpur Toll Plaza AMF/LTDB/APFC Panel Body Earthing GI Chemical Electrode 1 15
7 Faridpur Toll Plaza DG-1 Neutral Earthing Copper Chemical Electrode 1 15
8 Faridpur Toll Plaza DG-2 Neutral Earthing Copper Chemical Electrode 1 15
9 Faridpur Toll Plaza DG-1 Body Earthing GI Chemical Electrode 2 30
10 Faridpur Toll Plaza DG-2 Body Earthing GI Chemical Electrode 2 30
11 Faridpur Toll Plaza Admin Buiding earthing Copper Chemical Electrode 2 15 20
12 Faridpur Toll Plaza LA Earthing of Electrical Building Copper Chemical Electrode 3 15 50
13 Faridpur Toll Plaza Highmast Pole & Panel Body Earthing GI Chemical Electrode 12 48
14 Faridpur Toll Plaza Weight Bridge building & SPD LHS GI Chemical Electrode 2 10 20
15 Faridpur Toll Plaza Weight Bridge building & SPD RHS GI Chemical Electrode 2 10 20
16 Maigalganj Toll Plaza Transformer Neautral earthing Earthing Copper Chemical Electrode 1 15
17 Maigalganj Toll Plaza Transformer Body earthing Earthing GI Chemical Electrode 2 30
18 Maigalganj Toll Plaza Cubical Energy Meter Body Earthing GI Chemical Electrode 2 30
19 Maigalganj Toll Plaza 11 KVA VCB Panel Panel Body Earthing GI Chemical Electrode 2 30
20 Maigalganj Toll Plaza 250 KVA Stabilizer Body Earthing GI Chemical Electrode 1 15
21 Maigalganj Toll Plaza AMF/LTDB/APFC Panel Body Earthing GI Chemical Electrode 1 15
22 Maigalganj Toll Plaza DG-1 Neutral Earthing Copper Chemical Electrode 1 15
23 Maigalganj Toll Plaza DG-2 Neutral Earthing Copper Chemical Electrode 1 15
24 Maigalganj Toll Plaza DG-1 Body Earthing GI Chemical Electrode 2 30
25 Maigalganj Toll Plaza DG-2 Body Earthing GI Chemical Electrode 2 30
26 Maigalganj Toll Plaza Admin Buiding earthing Copper Chemical Electrode 2 15 20
27 Maigalganj Toll Plaza LA Earthing of Electrical Building Copper Chemical Electrode 3 15 50
28 Maigalganj Toll Plaza Highmast Pole & Panel Body Earthing GI Chemical Electrode 12 48
29 Maigalganj Toll Plaza Weight Bridge building & SPD LHS GI Chemical Electrode 2 10 20
30 Maigalganj Toll Plaza Weight Bridge building & SPD RHS GI Chemical Electrode 2 10 20
Spare 1304 50 5200 For site panel & highmast Pole
Location of Damaged Pole
Sr. No. Chainage Side Arm Type Foundation/ Bracket QTY of Damaged Pole Damaged Pole Availavle at Site Photo Location Remark
1 273+850 Median Double Arm Foundation 1 1 005 Reshambaag Near Katra Raod, Bareilly Reshambaag, near Katra Raod, Bakainiya, Uttar Pradesh 243503 Pole & Foundation Damaged
2 273+880 Median Double Arm Foundation 1 1 005 Reshambaag Near Katra Raod, Bareilly Reshambaag, near Katra Raod, Bakainiya, Uttar Pradesh 243503 Pole & Foundation Damaged
3 274+000 Median Double Arm Foundation 1 1
4 274+220 Median Double Arm Foundation 1 1 NH 30, Bakainiya, Uttar Pradesh 243503 Pole & Foundation Damaged
5 277+600 Median Double Arm Foundation 1 1 NH 730C, Bhagwanpur Phulwa, Uttar Pradesh 243503 Pole & Foundation Damaged
6 278+120 Median Double Arm Foundation 1 1 Bhagwanpur Phulwa, Uttar Pradesh 243503 Pole & Foundation Damaged
7 282+100 Median Double Arm Foundation 1 1
8 288+150 Median Double Arm Foundation 1 1 Fatehganj Purvi, Uttar Pradesh 243506 Pole Damaged
9 288+125 Median Double Arm Foundation 1 Fatehganj Purvi, Uttar Pradesh 243506 Pole Damaged
10 288+100 Median Double Arm Foundation 1 1 Fatehganj Purvi, Uttar Pradesh 243506 Pole & Foundation Damaged
11 288+075 Median Double Arm Foundation 1 1 Fatehganj Purvi, Uttar Pradesh 243506 Pole & Foundation Damaged
12 290+660 RHS Single Arm Bracket 1 1 NH 730C, Heerpur, Uttar Pradesh 242301 Pole Lay down due to bracket damaged
13 290+000 LHS Single Arm Foundation 1 1 01, Main Market Fatehganj Eest 01, Main Market, Eest, Fatehganj, Heerpur, Uttar Pradesh 242301 Pole & Foundation Damaged
14 290+100 LHS Single Arm Foundation 1 1
15 290+100 RHS Single Arm Foundation 1 1 01, Main Market Fatehganj Eest 01, Main Market, Eest, Fatehganj, Heerpur, Uttar Pradesh 242301 Pole & Foundation Damaged
16 290+100 RHS Single Arm Foundation 1 1 01, Main Market Fatehganj Eest 01, Main Market, Eest, Fatehganj, Heerpur, Uttar Pradesh 242301 Pole & Foundation Damaged
17 290+440 LHS Single Arm Bracket 1 1 Pole & Foundation Damaged
18 290+600 LHS Single Arm Bracket 1 1 Pole collaps due to storm
19 290+800 RHS Single Arm Bracket 1 1
20 303+370 Median Double Arm Foundation 1 1 G T Road, Tilhar 242301 Pole Collaps
21 303+395 Median Double Arm Foundation 1 1 G T Road, Tilhar 242301 Pole & Foundation Damaged
22 303+540 Median Double Arm Foundation 1 1 Mustafabad Urf Bhureli, Uttar Pradesh 242307 Pole Collaps
23 303+565 Median Double Arm Foundation 1 1 Mustafabad Urf Bhureli, Uttar Pradesh 242307 Pole Collaps
24 303+640 Median Double Arm Foundation 1 Tilhar City Rd, Mansoorpur, Tilhar, Uttar Pradesh 242307 Pole & Foundation Damaged
25 303+640 Median Double Arm Foundation 1 1 Tilhar City Rd, Mansoorpur, Tilhar, Uttar Pradesh 242307 Pole Collaps
26 303+320 Median Double Arm Foundation 1 1 G T Road, Tilhar 242301 Pole Collaps
27 303+350 Median Double Arm Foundation 1 1 G T Road, Tilhar 242301 Pole Collaps
28 303+350 Median Double Arm Foundation 1 1 G T Road, Tilhar 242301 Pole Collaps
29 303+370 Median Double Arm Foundation 1 1 G T Road, Tilhar 242301 Pole & Foundation Damaged
30 305+850 LHS Double Arm Foundation 1 1 NH30 bypass chauraha, Tilhar, Uttar Pradesh 242307 Pole Damaged
31 314+600 RHS Single Arm Bracket 1 WRF8+65 Railway Crossing Flyover, Banthara, Uttar Pradesh 242307 Bracket Pole Damaged
32 337+020 RHS Double Arm Foundation 1 NH24, Doraha, Jamuka, Uttar Pradesh 242306 Pole Damaged
33 348+600 LHS Single Arm Foundation 3
34 357+900 Median Double Arm Foundation 1 Barkheriya Jat
35 358+100 Median Double Arm Foundation 1 1
36 358+420 Median Double Arm Foundation 2 Barkheriya Jat
37 363+400 Median Double Arm Foundation 2 Mahmoodpur Saraiyan
38 369+820 Median Double Arm Foundation 1 1 Chhapartala, Maigalganj
39 370+200 Median Double Arm Foundation 1 Chhapartala, Maigalganj
40 370+700 Median Double Arm Foundation 1 Chhapartala, Maigalganj
41 376+800 Median Double Arm Foundation 1 Maigalganj -Aurangabaad Bypass
42 377+000 Median Double Arm Foundation 1 1 Maigalganj -Aurangabaad Bypass
43 377+350 Median Double Arm Foundation 1 1 Maigalganj -Aurangabaad Bypass
44 382.75 Median Double Arm Foundation 2 2 Neri
45 383.65 Median Double Arm Foundation 1 Neri
46 387+800 Median Double Arm Foundation 1 Bhudiya PO Kachuri,
47 387+800 Median Double Arm Foundation 1 1 Bhudiya PO Kachuri,
48 387+800 Median Double Arm Foundation 1 1 Bhudiya PO Kachuri,
49 388.13 Median Double Arm Foundation 1 Bhudiya PO Kachuri,
50 392+380 Median Double Arm Foundation 1 Maholi Bridge
51 392+400 Median Double Arm Foundation 1 1 Maholi Bridge
52 392+470 Median Double Arm Foundation 1 1 Maholi Bridge
53 392+600 Median Double Arm Foundation 1 1 Maholi Bridge
54 401+600 Median Double Arm Foundation 1 1 Bagaha
55 403+100 RHS Differencial Bracket 2 2
56 403+125 RHS Differencial Bracket 1 1
57 403+200 - 403+600 RHS Differencial Bracket 2 2
58 402+95 RHS Single Arm Foundation 3 3
59 417+400 Median Double Arm Foundation 1 1 kamta sariya-1
60 418+650 Median Double Arm Foundation 1 1 kamta sariya-2
Spare Double Arm Foundation 31 10
Copper Flexi Cable 3X1.5 Sq. mm Supply & Installation of 3Cx1.5 sq. Cu Flexible FRLS Wire for connection of light fitting. ( From Pole Junction Box to light fixtures)
SR NO Equipment Name Chainage Village Name Description Chainage Total No of Pole Total No of Light Fixture Copper Flexi Cable 3X1.5 Sq. mm Remark
From To Length in Mtr
1 LED STREET LIGHT 262.900 Kesharpur Truck Lay By Truck Lay by 262.900 263.150 250 8 8 104 Pole height 10 m & arm height 2-.2.5 m
13 LED STREET LIGHT 290.600 Shalpur Navdia ROB Flyover/ROB 290.050 291.350 1300 166 166 2158
17 LED STREET LIGHT 306.100 Tilhar City Rd Truck Lay By Truck Lay by 306.150 306.300 150 8 8 104
19 LED STREET LIGHT 314.640 Street Light Flyover/VUP 314.300 314.900 600 36 72 936
29 LED STREET LIGHT 348.600 Uncholia,, Gurudwara Truck Lay by 348.450 348.700 250 16 16 208
37 LED STREET LIGHT 370.700 Chapartala, Near Toll Truck Lay by 370.700 371.700 1000 8 8 104
44 LED STREET LIGHT 382.750 Truck Lay By Truck Lay By 382.450 382.700 250 8 8 104
51 LED STREET LIGHT 403.400 Hempur ROB RHS ROB 402.600 404.000 1400 118 236 3068
55 LED STREET LIGHT 413.830 Naveen Chowk, VUP VOP 413.830 413.830 0 30 75 975
57 LED STREET LIGHT 416.650 Bahuguda Chauraha Bridge Flyover/VUP 416.340 417.060 720 58 116 1508
Spare for toll & Site For installation 2731
Damaged Arm & Missing Light Details
Sr.No Chainage Side Arm Type Damaged Arm Missing Light Photo Location Remark
1 274+280 Median Double Arm 1 2 NH 30, Bakainiya, Uttar Pradesh 243503 Pole arm damage
2 303+580 Median Double Arm 1 1 0, Tilhar, Uttar Pradesh 242307 Pole arm damage
3 329+660 to 330 +00 RHS Flexi Arm 1 3 Hardoi Bypass, Saraikaiyan, Shahjahanpur, Uttar Pradesh 242406 1 Arm missing 3 light missing R H S
4 329+840 RHS Flexi Arm 2 2 Bypass churaha hardoi, Shahjahanpur Bypass Rd, Shahjahanpur, Uttar Pradesh 242406 2 Arm missing
5 331+900 RHS Differencial Arm 1 1 05, Roza, Ahmadpur Niwazpur, Shahjahanpur, Uttar Pradesh 242406 1 light missing
6 383+350 Median Double Arm 8 16 Neri
Required Total installation of 200 W LED Light fixture in place of 400W HPSV
SR NO Equipment Name Chainage Village Name Division Connection No. Meter Sr No Sanction Load Chainage No Of Existiong Pole Light Fixture Watt Total no of Pole Total No Required 200 W LED Light Fixture Remark
Single Arm Double/Differential Arm
From To Length in Mtr LHS RHS LHS Median RHS
1 HPSV STREET LIGHT 270.100 Faridpur Bypass Bareilly EDD-BAREILLY-II 4955777655 8572984 20 KW 269.700 270.350 650 26 400 26 52
2 HPSV STREET LIGHT 274.170 NEAR GURUDWARA FARIDPUR EDD-BAREILLY-II 1571806643 1250104 23 KW 273.700 274.450 750 28 400 28 56
3 HPSV STREET LIGHT 277.750 Faridpur Bareilly EDD-BAREILLY-II 0225766798 1251414 10 KW 277.300 278.100 800 28 400 28 56
4 HPSV STREET LIGHT 282.380 NEELAM VENEER, Tisuwa EDD-BAREILLY-II 3163720980 1250177 28 KW 282.000 282.800 800 29 400 29 58
5 HPSV STREET LIGHT 288.200 Uchesiya Mod Fatehganj Purbi Near Gupta Restourent EDD-BAREILLY-II Connection ID NA SS21684963 287.850 288.650 800 29 400 29 58
6 HPSV STREET LIGHT 289.120 Fatehganj Purbi EDD-BAREILLY-II 6208633634 8574560 15 KW 288.900 289.500 600 22 400 22 44
7 HPSV STREET LIGHT 295.370 Katara Chauraha LHS TILHAR 5372229478 2333972 AL2716531 30 KW 295.000 295.730 730 30 400 30 60
8 HPSV STREET LIGHT 295.370 Katara Chauraha RHS TILHAR 1459923079 9305779 30 KW 295.000 295.730 730 30 400 30 60
9 HPSV STREET LIGHT 303.650 Mansoorpur Tilhar Cut TILHAR Connection ID NA 01504441 '01504442 35 KW 303.250 303.950 700 26 400 26 52
10 HPSV STREET LIGHT 305.440 Tilahar LHS TILHAR Connection ID NA 9084719 9084801 30 KW 305.050 305.900 850 37 400 37 74
11 HPSV STREET LIGHT 305.410 Tilahar RHS TILHAR 2419462491 01504290 30 KW 37 400 37 74
12 LED STREET LIGHT 314.640 Street Light EDD I SHAHJAHANPUR Connection ID NA 21012086 21012085 314.300 314.900 600 19 17 250 36 72
13 HPSV STREET LIGHT 315.750 Banthara EDD I SHAHJAHANPUR 9469457893 3612728 315.350 316.000 650 29 29 400 58 116
14 HPSV STREET LIGHT 325.580 Bareilly Mod LHS EDD I SHAHJAHANPUR 5009545020 3612730 20 kW 325.100 326.000 900 32 400 32 64
15 HPSV STREET LIGHT 325.630 Bareilly Mod RHS EDD I SHAHJAHANPUR 5391347848 3612731 20 kW 30 400 30 60
16 HPSV STREET LIGHT 329.560 Near BHARAT DHABA BRIDGE LHS EDD-II, Bahadurganj, Shajhanpur 1258496779 X2333856 30 kW 329.100 330.000 900 34 400 34 68
17 HPSV STREET LIGHT 329.560 Roza Bypass RHS EDD-II, Bahadurganj, Shajhanpur 9848036325 X2333991 30 kW 329.100 330.000 900 35 400 35 70
18 HPSV STREET LIGHT 331.950 NEAR DOON SCHOOL LHS, Ahmadpur Niwazpur EDD-II, Bahadurganj, Shajhanpur 4548561751 X2333951 30 kW 331.600 332.050 450 17 400 17 34
19 HPSV STREET LIGHT 331.950 NEAR DOON SCHOOL RHS Ahmadpur Niwazpur EDD-II, Bahadurganj, Shajhanpur 3254860895 bill X2333925/ in meter X2333825 30 kW 331.600 332.050 450 16 400 16 32
20 HPSV STREET LIGHT 332.250 Honda Colony, Roza - 2 LHS Mandi Marg EDD-II, Bahadurganj, Shajhanpur 9945292476 X2734098 30 kW 332.050 332.500 450 16 400 16 32
21 HPSV STREET LIGHT 332.250 Kuda Plant, Roza -1 RHS Mandi Marg EDD-II, Bahadurganj, Shajhanpur 0539919387 X2333876 30 kW 332.050 332.500 450 17 400 17 34
22 HPSV STREET LIGHT 334.250 ROB RAILWAY CROSSING, LHS EDD-II, Bahadurganj, Shajhanpur 0851833728 X2333752 30 kW 333.700 334.900 1200 36 34 400 70 140
23 HPSV STREET LIGHT 336.650 Jamuhi, Shajahanpur Rd EDD-II, Bahadurganj, Shajhanpur 1159634807 CA0067214 336.300 337.100 800 33 33 400 66 132
24 HPSV STREET LIGHT 358.050 Barkheriya Jat EDD-II Mohammadi 7940728214 01498184 10 KW 357.600 358.450 850 33 400 33 66
25 HPSV STREET LIGHT 363.650 Highmast RHS Shahabad, Hardoi 0277502983 8421364 new found 363.400 363.950 550 21 400 21 42
26 HPSV STREET LIGHT 370.100 Chhapartala EDD-II Mohammadi 1496937181 AL2790038 new found 369.650 370.700 1050 43 400 43 86
27 HPSV STREET LIGHT 377.400 Aurangabad / Maigalganj Bypass EDD-II Mohammadi 6454321656 01498208 AL2789021 10 KW 376.800 378.000 1200 45 400 45 90
28 HPSV STREET LIGHT 383.650 Neri, Maholi EDD-I SITAPUR 0007078076 X2332906 40 kW 383.200 384.200 1000 42 400 42 84
29 HPSV STREET LIGHT 388.130 Bhudiya PO Kachuri, Sitapur EDD-I SITAPUR 3118405607 X2332904 30 kW 387.800 388.600 800 32 400 32 64
30 HPSV STREET LIGHT 392.470 Badagaon Maholi EDD-I SITAPUR 4763126954 X2332611 40 kW 391.900 393.000 1100 41 400 41 82
31 HPSV STREET LIGHT 396.200 Maholi LHS EDD-I SITAPUR 0193427051 X2332573 30 kVA 395.750 396.600 850 32 400 32 64
32 HPSV STREET LIGHT 396.200 Maholi RHS EDD-I SITAPUR 2930129477 X2332958 30 kW 395.750 396.600 850 32 400 32 64
33 HPSV STREET LIGHT 401.450 RICHHAI CHAURAHA EDD-I SITAPUR 6124797709 X2332947 40 kW 401.100 402.000 900 35 400 35 70
34 HPSV STREET LIGHT 407.570 Katili Bridge LHS EDD-I SITAPUR 2538736429 Bill '01494360 site '01494361 20 kW 407.290 408.000 710 27 400 27 54
35 HPSV STREET LIGHT 407.000 PAPER MILL BRIDGE II, KATILI RHS EDD-I SITAPUR 5883292673 01494362 20 kW 407.290 408.000 710 28 400 28 56
36 HPSV STREET LIGHT 417.800 Bahuguda Chauraha Bridge EDD-I SITAPUR 9652721835 SS21686440 30 kW 417.350 418.050 700 26 400 26 52
37 HPSV STREET LIGHT 418.700 kamta sariya-1 EDD-I SITAPUR 5958274382 SS21686436 30 kW 418.050 418.750 700 26 400 26 52
38 HPSV STREET LIGHT 418.700 kamta sariya-2 EDD-I SITAPUR 5391722308 SS21686437 30 kW 418.750 419.350 600 28 400 28 56
Total No Light Fixture for Replacement 0 0 342 560 338 1240 2480
Non-working/Damaged Light Fixture 70
Damaged/Non working LED light Fixture
SR NO Equipment Name Chainage Village Name Description Chainage Total No of Light Fixture Nonworking/Damaged Light fixture Light Remark
From To LHS RHS
1 LED STREET LIGHT 290.600 Shalpur Navdia ROB Flyover/ROB 290.050 291.350 166 7 10 17
2 LED STREET LIGHT 403.400 Hempur ROB RHS ROB 402.600 404.000 236 10 17 27 Due damaged crass barrier in , 5 No.s Pole are collaps & 3 Pole are are collaps in service road .
3 LED STREET LIGHT 413.830 Naveen Chowk, VUP VOP 413.830 413.830 75 3 8 11
4 LED STREET LIGHT 416.650 Bahuguda Chauraha Bridge Flyover/VUP 416.340 417.060 116 9 6 15
Location for underpass lighting
SR NO Chainage Village Name Description No of Wallmounted light Fixture for installation Remark
1 270.105 Faridpur Bypass VUP 6 Wallmounted Light not installed
2 274.180 NEAR GURUDWARA FARIDPUR PUP 4 Wallmounted Light not installed
3 277.780 Faridpur Bareilly VUP 6 Wallmounted Light not installed
4 282.380 NEELAM VENEER, Stiswa VUP 6 Wallmounted Light not installed
5 288.235 Uchesiya Mod Fatehganj Purbi Near Gupta Restourent VUP 6 Wallmounted Light not installed
6 290.410 Shalpur Navdia ROB PUP 4 Wallmounted Light not installed
7 291.020 Shalpur Navdia PUP 4 Wallmounted Light not installed
8 295.400 Katara VUP 6 Wallmounted Light not installed
9 303.685 Mansoorpur Tilhar Cut VUP 6 Wallmounted Light not installed
10 305.445 Tilahar BHS VUP 6 Wallmounted Light not installed
11 314.660 Street Light VUP/ROB 6 Wallmounted Light not installed
12 315.770 Banthara VUP 6 Wallmounted Light not installed
13 325.580 Bareilly Mod VUP 6 Wallmounted Light not installed
14 329.560 Hardoi Mod VUP 6 Wallmounted Light not installed
15 331.970 NEAR DOON SCHOOL BHS, Ahmadpur Niwazpur VUP 6 Wallmounted Light not installed
16 332.260 New Sattelite Bustand shahjahapur VUP 6 Wallmounted Light not installed
17 334.250 Hathoda, ROB VUP 6 Wallmounted Light not installed
18 334.620 Hathoda, ROB VUP 6 Wallmounted Light not installed
19 336.635 Jamuka, Atsalia VUP 6 Wallmounted Light not installed
20 358.095 Jangbahadurganj VUP 6 Wallmounted Light not installed
21 361.615 Barkheriya Jat VUP 6 Wallmounted Light not installed
22 363.690 Hariyali mod VUP 6 Wallmounted Light not installed
23 365.435 Pihani Mod VUP 6 Wallmounted Light not installed
24 370.100 Chapartala PUP 4 Wallmounted Light not installed
25 377.360 Aurangabad / Maigalganj Bypass VUP 6 Wallmounted Light not installed
26 383.650 Neri, Maholi VUP 6 Wallmounted Light not installed
27 388.130 Bhudiya PO Kachuri, Sitapur PUP 4 Wallmounted Light not installed
28 392.455 Badagaon Maholi VUP 6 Wallmounted Light not installed
29 396.150 Maholi BHS VUP 6 Wallmounted Light not installed
30 401.500 PUP 5 Wallmounted Light not installed
31 402.485 Hempur ROB RHS VUP 6 Wallmounted Light not installed
32 402.950 Hempur PUP 4 Wallmounted Light not installed
33 403.620 Hempur PUP 4 Wallmounted Light not installed
34 407.600 Katili Bridge BHS PUP 5 Wallmounted Light not installed
35 413.840 Naveen Chowk VOP 6 Wallmounted Light not installed
36 416.700 Bahuguda Chauraha Bridge VUP 6 Wallmounted Light not installed
37 417.800 kamta sariya-1 VUP 6 Wallmounted Light not installed
38 418.700 kamta sariya-2 PUP 4 Wallmounted Light not installed
Location for installation of Highmast Control Panel
SR NO Equipment Name Chainage Highmast Panel Remark
1 Highmast 266.620 1 Panel Rusted & Damaged
2 Highmast 266.980 1 Panel Rusted & Damaged
3 Highmast 267.160 1 Panel Rusted & Damaged
4 Highmast 268.150 1 Panel Rusted & Damaged
5 Highmast 270.000 2 Panel Rusted & Damaged
6 Highmast 307.000 1 Panel Rusted & Damaged
7 Highmast 315.750 2 Panel Rusted & Damaged
8 Highmast 325.580 2 Panel Rusted & Damaged
9 Highmast 329.560 2 Panel Rusted & Damaged
10 Highmast 331.700 1 Panel Rusted & Damaged
11 Highmast 331.950 3 Panel Rusted & Damaged
12 Highmast 334.250 1 Panel Rusted & Damaged
13 Highmast 356.350 1 Panel Rusted & Damaged
14 Highmast 358.050 1 Panel Rusted & Damaged
15 Highmast 360.570 1 Panel Rusted & Damaged
16 Highmast 363.650 1 Panel Rusted & Damaged
17 Highmast 365.450 1 Panel Rusted & Damaged
18 Highmast 372.100 2 Panel Rusted & Damaged
19 Highmast 372.350 3 Panel Rusted & Damaged
20 Highmast 374.080 1 Panel Rusted & Damaged
21 Highmast 383.650 1 Panel Rusted & Damaged
22 Highmast 388.130 1 Panel Rusted & Damaged
23 Highmast 395.550 1 Panel Rusted & Damaged
24 Highmast 401.450 1 Panel Rusted & Damaged
25 Highmast 407.600 1 Panel Rusted & Damaged
26 Highmast 413.900 1 Panel Rusted & Damaged
Project Name:- Bareilly Sitapur Highway project
HIGHMAST LOCATION AS PER SITE CONDITION & LUX CALUCLATION_MIN. 40 LUX
Type of Luminaries
S. No. Chainage Side Location Highmast Type of Bulb Distance From Median In Mtr LF48-502-025-57-XX 400W LED Floodlight - Total 46000 Lumens LF48-502-060-57-XX 400W LED Floodlight - Total 50000 Lumens Remarks - Type of Lux Design
1 270+100 LHS Shoulder 1 HPSV 35 5 2 TYPE -3
2 270+100 RHS Shoulder 1 HPSV 24 5 2 TYPE -3
3 274+170 LHS Shoulder 1 HPSV 44.3 14 2 TYPE -1
4 277+770 LHS Shoulder 1 HPSV 26 5 2 TYPE -3
5 277+770 RHS Shoulder 1 HPSV 34 5 2 TYPE -3
6 282+380 LHS Shoulder 1 HPSV 28 5 2 TYPE -3
7 282+380 RHS Shoulder 1 HPSV 34.5 5 2 TYPE -3
8 288+200 LHS Shoulder 1 HPSV 28.5 5 2 TYPE -3
9 288+200 RHS Shoulder 1 HPSV 36.5 5 2 TYPE -3
10 295+400 LHS Shoulder 1 HPSV 24 5 2 TYPE -3
11 295+400 RHS Shoulder 1 HPSV 32.6 5 2 TYPE -3
12 303+620 RHS Shoulder 1 HPSV 29.4 6 2 TYPE -4
13 305+410 LHS Shoulder 1 HPSV 24.7 5 2 TYPE -3
14 305+410 RHS Shoulder 1 HPSV 29.6 5 2 TYPE -3
15 307+000 RHS Shoulder 1 HPSV 14 6 2 TYPE -4
16 315+750 LHS Shoulder 1 HPSV 31.6 5 2 TYPE -3
17 315+750 RHS Shoulder 1 HPSV 25.3 5 2 TYPE -3
18 317+450 LHS Shoulder 1 HPSV 23.1 6 2 TYPE -4
19 325+630 LHS Shoulder 1 HPSV 21.5 5 2 TYPE -3
20 325+630 RHS Shoulder 1 HPSV 21.5 5 2 TYPE -3
21 329+560 LHS Shoulder 1 HPSV 29 5 2 TYPE -3
22 329+560 RHS Shoulder 1 HPSV 25 5 2 TYPE -3
23 331+710 RHS Shoulder 1 HPSV 24.4 6 2 TYPE -4
24 331+900 LHS Shoulder 1 HPSV 28.4 5 2 TYPE -3
25 331+950 RHS Shoulder 1 HPSV 34.9 5 2 TYPE -3
26 332+250 LHS Shoulder 1 HPSV 27 5 2 TYPE -3
27 332+250 RHS Shoulder 1 HPSV 27 5 2 TYPE -3
28 334+210 LHS Shoulder 1 HPSV 42.3 14 2 TYPE -1
29 334+910 LHS Shoulder 1 HPSV 30 6 2 TYPE -4
30 336+590 RHS Shoulder 1 HPSV 25.8 6 2 TYPE -4
31 356+380 RHS Shoulder 1 HPSV 16.6 6 2 TYPE -4
32 358+100 LHS Shoulder 1 HPSV 29.7 5 2 TYPE -3
33 358+100 RHS Shoulder 1 HPSV 28.8 5 2 TYPE -3
34 360+580 RHS Shoulder 1 HPSV 30.6 6 2 TYPE -4
35 361+600 LHS Shoulder 1 HPSV 35.3 5 2 TYPE -3
36 361+600 RHS Shoulder 1 HPSV 30 5 2 TYPE -3
37 363+650 LHS Shoulder 1 HPSV 25.4 5 2 TYPE -3
38 363+670 RHS Shoulder 1 HPSV 31.8 5 2 TYPE -3
39 365+440 LHS Shoulder 1 HPSV 29 5 2 TYPE -3
40 365+440 RHS Shoulder 1 HPSV 25.6 5 2 TYPE -3
41 370+100 RHS Shoulder 1 HPSV 29.4 5 2 TYPE -3
42 370+100 LHS Shoulder 1 HPSV 25.6 5 2 TYPE -3
43 374+080 RHS Shoulder 1 HPSV 14.2 6 2 TYPE -4
44 377+350 LHS Shoulder 1 HPSV 37.6 5 2 TYPE -3
45 377+350 RHS Shoulder 1 HPSV 60.6 17 2 TYPE -2
46 380+050 RHS Shoulder 1 HPSV 16.6 6 2 TYPE -4
47 383+650 LHS Shoulder 1 HPSV 46.7 14 2 TYPE -1
48 383+650 RHS Shoulder 1 HPSV 32.2 5 2 TYPE -3
49 388+130 LHS Shoulder 1 HPSV 30 5 2 TYPE -3
50 388+130 RHS Shoulder 1 HPSV 28.7 5 2 TYPE -3
51 392+470 LHS Shoulder 1 HPSV 23.5 5 2 TYPE -3
52 392+470 RHS Shoulder 1 HPSV 33 5 2 TYPE -3
53 395+550 RHS Shoulder 1 HPSV 18.5 6 2 TYPE -4
54 396+170 RHS Shoulder 1 HPSV 27.6 6 2 TYPE -4
55 401+500 LHS Shoulder 1 HPSV 13.6 5 2 TYPE -3
56 401+500 RHS Shoulder 1 HPSV 28.7 5 2 TYPE -3
57 403+570 RHS Shoulder 1 HPSV 24 6 2 TYPE -4
58 407+600 LHS Shoulder 1 HPSV 29.8 5 2 TYPE -3
59 407+600 RHS Shoulder 1 HPSV 27.4 5 2 TYPE -3
60 412+450 LHS Shoulder 1 HPSV 17.4 6 2 TYPE -4
61 413+900 LHS Shoulder 1 HPSV 11.6 6 2 TYPE -4
62 417+800 LHS Shoulder 1 HPSV 31.3 5 2 TYPE -3
63 417+800 RHS Shoulder 1 HPSV 32.2 5 2 TYPE -3
64 418+690 LHS Shoulder 1 HPSV 13.6 6 2 TYPE -4
Total Nos. of High Mast to replace Luminaries 64 375 128
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_JSON
RFP - Street Light BSRP NSPPL 31.07.2026.pdf
TENDER_DOCUMENT • 4.92 MB
Annexure C3 BOQ with backup for Electrical Improvement work in BS Project.xlsx
BOQ_DOCUMENT • 4.55 MB
Corrigendum-I---NSPPL-RFP-BSRP-Hwy-Street-Light-14082026_88AS.pdf
CORRIGENDUM_DOCUMENT • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .