Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
4 Mar 2021, 6:00 pmClosed
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
MAITENANCE AND REPAIR / REPLACEMENT OF STREET LIGHTS WITH CONNECTED ITEMS IN TECHNICAL AREA AT AFS BIDAR.
2021_MES_419122_1
8273/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Bidar
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Bidar
₹24,000
Yes
31 Mar 2021
4 Feb 2021
5 Mar 2021
4 Feb 2021
4 Mar 2021
18 Feb 2021
Amount
Taking down street light/ flood light fittings for repair/ replacement of any capacity from 45 - 250 W and refixing the same after all repair work complete all as specified and as directed. Note: Spares shall be measured and paid separately.
Supply only LED driver of 40/45 W LED Street light/ Post top / flood light fitting.
Supply only LED driver of 72 W LED Street light/ flood light fitting.
Supply only LED driver of 90 W LED Street light/ flood light fitting.
Supply only LED driver of 120 W LED Flood light fitting.
Supply only LED driver of 150 W LED flood light fitting.
Supply only LED driver of 240 W LED flood light fitting.
M&L wiring with 3 core, 2.5 sqmm PVC insulated PVC sheathed multistranded flexible copper conductor cable drawn through existing conduit / pipe from junction box to fitting complete including taking down old unsv cable complete all as specified and as directed.
S&F Junction box made from FRP sheet ready made of size 300x200x 100 mm having 100 A capacity including RYB and neutral with aluminum busbar with 4 way connector, MCB SP 6 Amp 10 kA 240 V - 01 No. fixed to pole / wall with MS clamp 25x5 mm duly painted with one coat of red oxide and two coats of enamel / silver paint to MS clamp including taking down existing junction box complete all as specified and as directed.
S&F in replaement of MCB TPN 32 Amp 10 kA, 415 V, 50 Hz, AC complete all as specified and as directed. Make : Legrand Model No. 4086 80 or techno commercially equivalent model of make ABB / Siemens
S&F in replacement of MCB TPN 63 Amp 10 kA, 415 V, 50 Hz, AC complete all as specified and as directed. Make : Legrand Model No. 4086 83 or techno commercially equivalent model of make ABB / Siemens
Taking down U/S light fittings and S & F LED light fitting, 16 watts energy saving enviroment friendly, long life aesthetically designed die cast aluminium landscape luminaire for downward lighting with high power LED as light source complete with all accessories complete all as specified and as directed.
Supply, fix, test and commissioning 45 Watt LED street light fittings, High efficiency IP 66 protection, powder coated pressure die cast aluminium housing and clear injection moulded polycarbonate / toughened glass have multi chip on board LED and metal clad PCB. The minimum lumen output of the system shall be greater than 7200 lumens with minimum lumens per watt 101±3% and must maintain 70% of lumens output at 50000 bhrs, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system including taking down existing fittings and fixtures complete all as specified and as directed.
Supply, fix, test and commissioning 70 Watt LED street light fittings, High Efficiency IP 66 protection, powder coated pressure die cast aluminium housing and clear injection moulded polycarbonate / toughened glass have multi chip on board LED and metal clad PCB. The minimum lumen output of the system shall be greater than 7200 lumens with minimum lumens per watt 101±3% and must maintain 70% of lumens output at 50000 bhrs, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system including taking down existing fittings and fixtures complete all as specified and as directed.
Taking down U/S light fittings and Supply, fix, test and commissioning 100 Watt LED flood light fittings, with High pressure die cast housing with lens IP 65 protection, powder coated CCT(k) 6000, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system including taking down existing fittings and fixtures complete all as specified and as directed.
Supply and Fix post top lantern fitting CFL 2x18 watts including CFL and connecting with suitable size cable including taking down old unserviceable one complete all as specified and as directed.
M&L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter long, single swan neck type, including preparation of surfaces, applying two coats of aluminium paint over one primer coat of red oxide zinc chrome primer and taking down existing pole complete all as specified and directed. The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161 complete all as specified and as directed. NOTE : Earth work and PCC foundation shall be measured and paid separately.
PCC 1:4:8, type D2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete for steel pole complete all as specified and as directed.
PCC 1:2:4, type B1 (using 20 mm graded granite stone aggregate) as in coping for steel pole including necessary formwork complete all as specified and as directed.
Mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint complete all as specified and as directed.
S&F in replacement of 3 pole power contactor ML3 including necessary connections for incoming and outgoing complete all as specified and as directed . Make : L&T Cat Part No. SS90721 or techno commercially equivalent model of make Legrand / Philips / C&S
S&F in replacement of digital time switch Astro suitable for switching on/ off light and other electric devices according to the rising / setting of the sun with combination function for creating switching program in which devices are switched according to astronomical time and / or fixed preset times and also suitable for daily astronomical calculation of the sunrise / sunset time based on the entetred location or location coordinates complete all as specified and as directed. Make : Legrand Cat Part No. 4126 54 (Alpharex3D21 astro,1 channel) or techno commercially equivalent model of make L&T / C&S
Painting to PCC pole with two coats of cement base paint of approved colour shade and writing Pole numbers with white paint having black background enamel paint suitable for outdoor, including cleaning of poles, removing creeper etc from pole complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pole, fixed to wall / pole of 16 Sqmm 4.0 core XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing including taking down old cable complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pole, fixed to wall / pole of 10 Sqmm 4.0 core XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing including taking down old cable complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pole, fixed to wall / pole of 10 Sqmm 2.0 core XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing including taking down old cable complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50 m and deposited where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L 40mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 for protection of cable laid in trenches complete all as specified and as directed.
M&L 50mm bore GI tubing light grade including necessary fittings such as bend, tee, elbow etc complete in trenches/ on wall complete all as specified and as directed.
Taking down old unserviceable PCC LT cable covers complete all as specified and as directed.
M&L unreinforced pre cast concrete cable cover class LV type I flat size 250 x 150 x 40 mm for cable protection complete all as specified and as directed.
Supply and spreading fine river sand in trenches for cushioning of under ground cable complete all as specified and as directed. Note : Only punned thickness will be measured and paid.
Relaying old serviceable unreinforced pre cast concrete cable cover taken out from the trenches complete all as specified and as directed.
Supply and fixing in repairs MH Lamp 70 W complete all as specified and as directed.
Supply and fixing in repairs MH Lamp 150 W complete all as specified and as directed.
Supply and fixing in repair MH Lamp 250 W complete all as specified and as directed.
Supply and fixing in repairs MH Lamp 400 W complete all as specified and as directed.
Supply and fixing in repairs fluorescent tube rods T-5 24 Watts, 230 volts complete all as specified and as directed.
Supply and fixing in repairs electronic ballast (choke) suitable for FTL T-5 24 Watt fitting complete all as specified and as directed.
Supply and fixing in repairs heavy duty copper ballast 400 watts, 230 V single phase, suitable for SV /MH fittings as in post top lantern/ street lights/ flood light fittings complete all as specified and as directed.
Supply and fixing in repairs heavy duty copper ballast 250 watts, 230 V single phase suitable for SV/MH fittings as in post top lantern/ street lights/ flood light fittings complete all as specified and as directed.
Supply and fixing in repairs heavy duty copper ballast 150 watts 230 V single phase suitable for MH/ SV fittings as in post top lantern/street lights/flood light fittings complete all as specified and as directed.
Supply and fixing in repairs construction heavy duty copper ballast 70 watts,230 V single phase, suitable for SV/MH fittings as in post top lantern/street lights/flood light fittings complete all as specified and as directed.
Supply and fixing in repairs Vaccum pressure impregnated capacitor 10 MFD AC 250 volts complete all as specified and as directed..
Supply and fixing in repairs Vaccum pressure impregnated capacitor 15 MFD AC 250 volts complete all as specified and as directed.
Supply and fixing in repairs pressure impregnated capacitor 20 MFD AC 250 volts complete all as specified and as directed.
Supply and fixing in repairs lamp holder suitable for 70/150/ 250/ 400 W AC 230 V, Single phase complete complete all as specified and as directed.
Supply and fixing in repairs Non retrofit CFL lamp 18 watts 2/4 pin type 230 volts complete all as specified and as directed.
Supply and fixing in repairs Non retrofit CFL lamp 11 watts 2/4 pin type 230 volts complete all as specified and as directed.
Supply and fixing in repairs copper ballast / choke 1x18 watts, 230 volts suitable for CFL fitting complete all as specified and as directed. Make : CG Cat Pt No SFB7018 or techno commercially equivalent model of make Havells/ Bajaj / Phillips
Supply and fixing in repairs copper ballast/choke 1x11 watts 230 volts suitable for CFL fitting complete all as specified and as directed. Make: CG Cat Pt No SFB7019/11 or techno commercially equivalent model of make Havells/ Bajaj / Phillips
Supply and fixing aviation obstruction LED light fitting and connecting with suitable size cable including taking down old unserviceable one complete all as specified and as directed. Make : Bajaj Cat Part No.BGAV 302 LED or techno commercially equivalent model of make Philips / CG / Havells
Supply and fix post top lantern fittings MH type with lamp 70 Watt including taking down old unserviceable one complete all as specified and as directed. Make : CG Cat part No MHSLJ07IH or techno commercially equivalent model of make Philips / CG / Havells
Supply and Fix bollard type fitting CFL 2x11 watts with 2 Nos 11 watts CFL and connecting with suitable size cable including taking down old unserviceable one complete all as specified and as directed.
GOWRIPRIYA ENTERPRISES
M/s.Santosh Kotarki
Siddique constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .