Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.8 LAccepted-Finance F22 117 SECTOR 3 ROHINI 110085 DELHI | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹54.8 L | L1 | Accepted-Finance L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Not Eligible |
| 3 | Rejected-Technical NEAR JAIN DHARAMSALA CHICK SANTER MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | - | - | Rejected-Technical Not Eligible |
| Sl No | Description | Qty | Unit | M/S M L BROTHER L1 |
|---|---|---|---|---|
| 1.00SH-I DG sets and Panels | ||||
| 2.00 | Supply Installation Testing Commissioning of "Silent Type" Radiator Cooled, Diesel Generating Set along with having Prime mover power rating of 25 KVA at 0.8 lagging power factor, 415 volts, 1500 RPM, 3 phase system, as per ISO 8528 and consisting of the following: | 1 | Job | 6,79,000 ₹6,79,000 Lowest |
| 3.00(a) Diesel Engine: 4 stroke, electronic governor, power command control module, radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. | ||||
| 4.00(b) Alternator: Synchronous alternator rated for 25 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR, , terminal arrangement i/c 100 A alumunium bus-duct box with other associated equipment conforming to IS:4722 / BS 2613 suitable for tropical conditions and with class F / H insulation. | ||||
| 5.00(c) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on existing concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. | ||||
| 6.00(d) Fuel Tank: Day service fuel tank of upto 100 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. | ||||
| 7.00(e) Exhaust System: Dry Exhaust manifold with residential exhaust silencer and catalytic convertor. | ||||
| 8.00(f) Starting System: 12V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries with MS battery stand etc. as required as per specifications. | ||||
| 9.00(g) Acoustic Enclosure : Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. | ||||
| 10.00(i) The work should be as per Central Electrical Authority / latest Pollution control board standards. | ||||
Tender Value
₹51.8 L
EMD Value
₹1.6 L
Closing Date
27 May 2026, 10:00 amClosed
Dy. GM (E-E)
AAI, Bagdogra Airport, Dist-Darjeeling
Construction of DVOR Building and allied works at Katihar Airport, Katihar SH- Electrical Works.
2026_AAI_276442_1
AAI/KAT/DGM/26-27/NIT/01/309
Open Tender
Electrical Works
Item Rate
120 days
AAI, Katihar ACs, Station
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹1.6 L
25 Jul 2026
5 May 2026
28 May 2026
5 May 2026
27 May 2026
5 May 2026
5 May 2026 - 10 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SH-I DG sets and Panels | - | - | - | - |
| 2 | Supply Installation Testing Commissioning of "Silent Type" Radiator Cooled, Diesel Generating Set along with having Prime mover power rating of 25 KVA at 0.8 lagging power factor, 415 volts, 1500 RPM, 3 phase system, as per ISO 8528 and consisting of the following: | 1 | Job | 6,74,000 | ₹6,74,000 |
| 3 | (a) Diesel Engine: 4 stroke, electronic governor, power command control module, radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. | - | - | - | - |
| 4 | (b) Alternator: Synchronous alternator rated for 25 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR, , terminal arrangement i/c 100 A alumunium bus-duct box with other associated equipment conforming to IS:4722 / BS 2613 suitable for tropical conditions and with class F / H insulation. | - | - | - | - |
| 5 | (c) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on existing concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. | - | - | - | - |
| 6 | (d) Fuel Tank: Day service fuel tank of upto 100 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. | - | - | - | - |
| 7 | (e) Exhaust System: Dry Exhaust manifold with residential exhaust silencer and catalytic convertor. | - | - | - | - |
| 8 | (f) Starting System: 12V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries with MS battery stand etc. as required as per specifications. | - | - | - | - |
| 9 | (g) Acoustic Enclosure : Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. | - | - | - | - |
| 10 | (i) The work should be as per Central Electrical Authority / latest Pollution control board standards. | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
TENDERDOCUMENT.pdf
Tender Documents • 8.22 MB
BOQ_322925.xls
BOQ • 0.44 MB
Corrigendum1.pdf
PDF • 2.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].