Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32,896Admitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹36,714+₹3,818 (11.6%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹39,014+₹6,118 (18.6%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹57,000+₹24,104 (73.3%)Admitted-Finance FATEHPUR FATEHPUR FATEHPUR RAJAURI JAMMU KASHMIR 185131 | RAJOURI | JAMMU AND KASHMIR | 185131 | L4 | Admitted-Finance | |
| 5 | Rejected-Technical | - | Rejected-Technical ALL RELEVANT DOCUMENTS NOT UPLOADED AS PER SBD |
| Sl No | Description | Qty | Unit | Naresh Kumar L1 | C.T ELECTRICAL ENGINEER L4 | M/s Wazir Agencies L3 | M/S SURYA ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|
| 1.00Repair/Reclamation of Damaged Distribution Transformers (11KV/0.44KV) 63 KVA DTR | |||||||
| 2.00 | Unloading of damaged transformer, Opening of transformer, draining of oil, opening of HV/LV connections, taking out core, opening of side channels /core laminations (complete job). | 1 | Job | 285 ₹285 | 190 ₹190 Lowest | 320 ₹320 | 300 ₹300 |
| 3.00 | Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of HT Coils (Three Limbs) | 1 | Set | 47 ₹47 | 100 ₹100 | 40 ₹40 Lowest | 50 ₹50 |
| 4.00 | Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of LT Coils (Three Limbs) | 1 | set | 47 ₹47 | 100 ₹100 | 40 ₹40 Lowest | 50 ₹50 |
| 5.00 | Reconditioning of LV Leg Coil…(Copper) | 1 | kg | - | - | 88 ₹88 Lowest | - |
| 6.00 | Reconditioning of LV Leg Coil…(Aluminium) | 1 | kg | 95 ₹95 Lowest | 100 ₹100 | - | 130 ₹130 |
| 7.00 | Winding of HV Leg coil….(Copper) | 1 | kg | - | - | - | - |
| 8.00 | Winding of LV Leg coil….(Copper) | 1 | kg | - | - | 76 ₹76 Lowest | - |
| 9.00 | Winding of HV Leg coil….(Aluminium) | 1 | kg | 86 ₹86 | 65 ₹65 | 56 ₹56 Lowest | 100 ₹100 |
| 10.00 | Winding of LV Leg coil….(Aluminium) | 1 | kg | 86 ₹86 | 65 ₹65 | 36 ₹36 Lowest | 100 ₹100 |
Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
24 Dec 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer. JPDCL, ED, Rajouri
Executive Engineer. JPDCL, ED, Rajouri.
Annual Fixing of Rates for Repair/Reclamation of Damaged DTs of Various Capacities Under the Jurisdiction of JPDCL Electric Division Rajouri.
2024_PDD_266655_1
EDR/64 of 2024-25 Dated 02.12.2024
Open Tender
Electrical Works
Turn-key
RAJOURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
Executive Engineer, JPDCL, ED, Rajouri
₹2.5 L
15 Feb 2025
2 Dec 2024
26 Dec 2024
2 Dec 2024
24 Dec 2024
2 Dec 2024
Amount
Repair/Reclamation of Damaged Distribution Transformers (11KV/0.44KV) 63 KVA DTR
Unloading of damaged transformer, Opening of transformer, draining of oil, opening of HV/LV connections, taking out core, opening of side channels /core laminations (complete job).
Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of HT Coils (Three Limbs)
Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of LT Coils (Three Limbs)
Reconditioning of LV Leg Coil…(Copper)
Reconditioning of LV Leg Coil…(Aluminium)
Winding of HV Leg coil….(Copper)
Winding of LV Leg coil….(Copper)
Winding of HV Leg coil….(Aluminium)
Winding of LV Leg coil….(Aluminium)
Impregnation and heat treatment of coils
Cleaning and washing of transformer tank, radiators, top covers etc
Repairing, welding of transformer tank,radiators, Aressting of oil leakages etc if any
Painting of transformer tank (inner and outer side), radiators (complete job)
Refitting/Replacement of Bushings only HV/LV
Refitting/Replacement of Bush rods only HV/LV
Filtration &Topping of transformer oil.
Re-assembling, refitting of coils including all sundry items to be replaced and tanking up of assembled job after heat treatment and meggering, refitting & testing of transformer and loading/dispatching of same.
Weighing, stacking and loading of Aluminium/copper Scrap etc
Description of Work / Item(s)
Amount
Repair/Reclamation of Damaged Distribution Transformers (11KV/0.44KV) 400/500/630 KVA DTR at site if required.
Dismantling & re-fixing of 11 KV Jumper set/ Link set/ G.O set of defective transformers
Dismantling and re-fixing of LV cable circuit of transformer
Dismounting of defective transformer from bed
Dragging of defective transformer from sub-station site to repairing site and back for an average distance of 50 mtrs
Opening/ De-tanking of transformer for assessment of damages, re-assembling, re-fitting of coils & core including replacement of all damaged sundry items and re-tanking of assembled core
Topping with transformer oil after Filtration/ Reconditioning
Reconditioning of HV coil (aluminium)
Reconditioning of LV coil (aluminium)
Winding of HV coil (Aluminium)
Winding of LV coil (Aluminium)
Replacing of HT/LT damaged Copper Strip with new copper strip
Replacement of HT/LT Bushing
Replacement of HT/LT Bush Rod
Mounting of repaired transformer on bed
Transportation of material from Divisional workshop Rajouri to the respective site for first 10 kms
Transportation of material for every additional 10 km
Description of Work / Item(s)
Amount
Loading/Unloading of Damaged Distribution Transformers (11KV/0.44KV) 25 KVA DTR
Unloading of damaged transformer and its dragging.
Loading of damaged DTR for its carriage to CWSP.
Loading/Unloading of Damaged Distribution Transformers (11KV/0.44KV) 63 KVA DTR
Unloading of damaged transformer and its dragging.
Loading of damaged DTR for its carriage to CWSP.
Loading/Unloading of Damaged Distribution Transformers (11KV/0.44KV) 100 KVA DTR
Unloading of damaged transformer and its dragging.
Loading of damaged DTR for its carriage to CWSP.
Loading/Unloading of Damaged Distribution Transformers (11KV/0.44KV) 250 KVA DTR
Unloading of damaged transformer and its dragging.
Complete Inspection of DTR for accessing its damage.
Loading of damaged DTR for its carriage to CWSP.
Loading/Unloading of Damaged Distribution Transformers (11KV/0.44KV) 400/500/630 KVA DTR
Unloading of damaged transformer and its dragging.
Complete Inspection of DTR for accessing its damage.
Loading of damaged DTR for its carriage to CWSP.
Description of Work / Item(s)
Amount
Repair/Reclamation of Damaged Distribution Transformers (11KV/0.44KV) 25 KVA DTR
Unloading of damaged transformer, Opening of transformer, draining of oil, opening of HV/LV connections, taking out core, opening of side channels /core laminations (complete job).
Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of HT Coils (Three Limbs)
Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of LT Coils (Three Limbs)
Reconditioning of LV Leg Coil…(Copper)
Reconditioning of LV Leg Coil…(Aluminium)
Winding of HV Leg coil….(Copper)
Winding of LV Leg coil….(Copper)
Winding of HV Leg coil….(Aluminium)
Winding of LV Leg coil….(Aluminium)
Impregnation and heat treatment of coils
Cleaning and washing of transformer tank, radiators, top covers etc
Repairing, welding of transformer tank,radiators, Aressting of oil leakages etc if any
Painting of transformer tank (inner and outer side), radiators (complete job)
Refitting/Replacement of Bushings only HV/LV
Refitting/Replacement of Bush rods only HV/LV
Filtration &Topping of transformer oil.
Re-assembling, refitting of coils including all sundry items to be replaced and tanking up of assembled job after heat treatment and meggering, refitting & testing of transformer and loading/dispatching of same.
Weighing, stacking and loading of Aluminium/copper Scrap etc
Description of Work / Item(s)
Amount
Repair/Reclamation of Damaged Distribution Transformers (11KV/0.44KV) 100 KVA DTR
Unloading of damaged transformer, Opening of transformer, draining of oil, opening of HV/LV connections, taking out core, opening of side channels /core laminations (complete job).
Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of HT Coils (Three Limbs)
Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of LT Coils (Three Limbs)
Reconditioning of LV Leg Coil…(Copper)
Reconditioning of LV Leg Coil…(Aluminium)
Winding of HV Leg coil….(Copper)
Winding of LV Leg coil….(Copper)
Winding of HV Leg coil….(Aluminium)
Winding of LV Leg coil….(Aluminium)
Impregnation and heat treatment of coils
Cleaning and washing of transformer tank, radiators, top covers etc
Repairing, welding of transformer tank,radiators, Aressting of oil leakages etc if any
Painting of transformer tank (inner and outer side), radiators (complete job)
Refitting/Replacement of Bushings only HV/LV
Refitting/Replacement of Bush rods only HV/LV
Filtration &Topping of transformer oil.
Re-assembling, refitting of coils including all sundry items to be replaced and tanking up of assembled job after heat treatment and meggering, refitting & testing of transformer and loading/dispatching of same.
Weighing, stacking and loading of Aluminium/copper Scrap etc
Description of Work / Item(s)
Amount
Repair/Reclamation of Damaged Distribution Transformers (11KV/0.44KV) 250 KVA DTR
Unloading of damaged transformer, Opening of transformer, draining of oil, opening of HV/LV connections, taking out core, opening of side channels /core laminations (complete job).
Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of HT Coils (Three Limbs)
Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of LT Coils (Three Limbs)
Reconditioning of LV Leg Coil…(Copper)
Reconditioning of LV Leg Coil…(Aluminium)
Winding of HV Leg coil….(Copper)
Winding of LV Leg coil….(Copper)
Winding of HV Leg coil….(Aluminium)
Winding of LV Leg coil….(Aluminium)
Impregnation and heat treatment of coils
Cleaning and washing of transformer tank, radiators, top covers etc
Repairing, welding of transformer tank,radiators, Aressting of oil leakages etc if any
Painting of transformer tank (inner and outer side), radiators (complete job)
Refitting/Replacement of Bushings only HV/LV
Refitting/Replacement of Bush rods only HV/LV
Filtration &Topping of transformer oil.
Re-assembling, refitting of coils including all sundry items to be replaced and tanking up of assembled job after heat treatment and meggering, refitting & testing of transformer and loading/dispatching of same.
Weighing, stacking and loading of Aluminium/copper Scrap etc
Description of Work / Item(s)
Amount
Loading/Unloading of Damaged Distribution Transformers (11KV/0.44KV) 400/500/630 KVA DTR
Unloading of damaged transformer, Opening of transformer, draining of oil, opening of HV/LV connections, taking out core, opening of side channels /core laminations (complete job).
Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of HT Coils (Three Limbs)
Taking out of all the coils after opening the connections and inspection of coils to asertain the damage of LT Coils (Three Limbs)
Replacing of HT/LT damaged Copper Strip with new copper strip
Reconditioning of LV Leg Coil…(Copper)
Reconditioning of LV Leg Coil…(Aluminium)
Winding of HV Leg coil….(Copper)
Winding of LV Leg coil….(Copper)
Winding of HV Leg coil….(Aluminium)
Winding of LV Leg coil….(Aluminium)
Impregnation and heat treatment of coils
Cleaning and washing of transformer tank, radiators, top covers etc
Repairing, welding of transformer tank,radiators, Aressting of oil leakages etc if any
Painting of transformer tank (inner and outer side), radiators (complete job)
Refitting/Replacement of Bushings only HV/LV
Refitting/Replacement of Bush rods only HV/LV
Filtration &Topping of transformer oil.
Re-assembling, refitting of coils including all sundry items to be replaced and tanking up of assembled job after heat treatment and meggering, refitting & testing of transformer and loading/dispatching of same.
Weighing, stacking and loading of Aluminium/copper Scrap etc
Description of Work / Item(s)
Amount
Repair/Reclamation of Damaged Distribution Transformers (11KV/0.44KV) 25 KVA DTR at site.
Dismantling & re-fixing of 11 KV Jumper set/ Link set/ G.O set of defective transformers
Dismantling and re-fixing of LV cable circuit of transformer
Dismounting of defective transformer from bed
Dragging of defective transformer from sub-station site to repairing site and back for an average distance of 50 mtrs
Opening/ De-tanking of transformer for assessment of damages, re-assembling, re-fitting of coils & core including replacement of all damaged sundry items and re-tanking of assembled core
Topping with transformer oil after Filtration/ Reconditioning
Reconditioning of HV coil (aluminium)
Reconditioning of LV coil (aluminium)
Winding of HV coil (Aluminium)
Winding of LV coil (Aluminium)
Replacement of HT/LT Bushing
Replacement of HT/LT Bush Rod
Mounting of repaired transformer on bed
Transportation of material from Divisional workshop Rajouri to the respective site for first 10 kms
Transportation of material for every additional 10 km
Description of Work / Item(s)
Amount
Repair/Reclamation of Damaged Distribution Transformers (11KV/0.44KV) 63 KVA DTR at site.
Dismantling & re-fixing of 11 KV Jumper set/ Link set/ G.O set of defective transformers
Dismantling and re-fixing of LV cable circuit of transformer
Dismounting of defective transformer from bed
Dragging of defective transformer from sub-station site to repairing site and back for an average distance of 50 mtrs
Opening/ De-tanking of transformer for assessment of damages, re-assembling, re-fitting of coils & core including replacement of all damaged sundry items and re-tanking of assembled core
Topping with transformer oil after Filtration/ Reconditioning
Reconditioning of HV coil (aluminium)
Reconditioning of LV coil (aluminium)
Winding of HV coil (Aluminium)
Winding of LV coil (Aluminium)
Replacement of HT/LT Bushing
Replacement of HT/LT Bush Rod
Mounting of repaired transformer on bed
Transportation of material from Divisional workshop Rajouri to the respective site for first 10 kms
Transportation of material for every additional 10 km
Description of Work / Item(s)
Amount
Repair/Reclamation of Damaged Distribution Transformers (11KV/0.44KV) 100 KVA DTR at site.
Dismantling & re-fixing of 11 KV Jumper set/ Link set/ G.O set of defective transformers
Dismantling and re-fixing of LV cable circuit of transformer
Dismounting of defective transformer from bed
Dragging of defective transformer from sub-station site to repairing site and back for an average distance of 50 mtrs
Opening/ De-tanking of transformer for assessment of damages, re-assembling, re-fitting of coils & core including replacement of all damaged sundry items and re-tanking of assembled core
Topping with transformer oil after Filtration/ Reconditioning
Reconditioning of HV coil (aluminium)
Reconditioning of LV coil (aluminium)
Winding of HV coil (Aluminium)
Winding of LV coil (Aluminium)
Replacement of HT/LT Bushing
Replacement of HT/LT Bush Rod
Mounting of repaired transformer on bed
Transportation of material from Divisional workshop Rajouri to the respective site for first 10 kms
Transportation of material for every additional 10 km
Description of Work / Item(s)
Amount
Repair/Reclamation of Damaged Distribution Transformers (11KV/0.44KV) 250 KVA DTR at site.
Dismantling & re-fixing of 11 KV Jumper set/ Link set/ G.O set of defective transformers
Dismantling and re-fixing of LV cable circuit of transformer
Dismounting of defective transformer from bed
Dragging of defective transformer from sub-station site to repairing site and back for an average distance of 50 mtrs
Opening/ De-tanking of transformer for assessment of damages, re-assembling, re-fitting of coils & core including replacement of all damaged sundry items and re-tanking of assembled core
Topping with transformer oil after Filtration/ Reconditioning
Reconditioning of HV coil (aluminium)
Reconditioning of LV coil (aluminium)
Winding of HV coil (Aluminium)
Winding of LV coil (Aluminium)
Replacement of HT/LT Bushing
Replacement of HT/LT Bush Rod
Mounting of repaired transformer on bed
Transportation of material from Divisional workshop Rajouri to the respective site for first 10 kms
Transportation of material for every additional 10 km
M/S SURYA ENTERPRISES (BID ID -2294147)
M/s Wazir Agencies (BID ID -2295220)
C.T ELECTRICAL ENGINEER (BID ID -2294891)
Naresh Kumar (BID ID -2293697)
M/S SURYA ENTERPRISES (BID ID -2294147)
M/s Wazir Agencies (BID ID -2295220)
M/s Wazir Agencies (BID ID -2295220)
M/S SURYA ENTERPRISES (BID ID -2294147)
C.T ELECTRICAL ENGINEER (BID ID -2294891)
M/s Wazir Agencies (BID ID -2295220)
M/S SURYA ENTERPRISES (BID ID -2294147)
C.T ELECTRICAL ENGINEER (BID ID -2294891)
M/S SURYA ENTERPRISES (BID ID -2294147)
M/s Wazir Agencies (BID ID -2295220)
C.T ELECTRICAL ENGINEER (BID ID -2294891)
Naresh Kumar (BID ID -2293697)
M/s Wazir Agencies (BID ID -2295220)
C.T ELECTRICAL ENGINEER (BID ID -2294891)
M/S SURYA ENTERPRISES (BID ID -2294147)
Naresh Kumar (BID ID -2293697)
C.T ELECTRICAL ENGINEER (BID ID -2294891)
M/s Wazir Agencies (BID ID -2295220)
M/S SURYA ENTERPRISES (BID ID -2294147)
C.T ELECTRICAL ENGINEER (BID ID -2294891)
M/s Wazir Agencies (BID ID -2295220)
M/S SURYA ENTERPRISES (BID ID -2294147)
C.T ELECTRICAL ENGINEER (BID ID -2294891)
M/S SURYA ENTERPRISES (BID ID -2294147)
M/s Wazir Agencies (BID ID -2295220)
C.T ELECTRICAL ENGINEER (BID ID -2294891)
Naresh Kumar (BID ID -2293697)
M/S SURYA ENTERPRISES (BID ID -2294147)
M/s Wazir Agencies (BID ID -2295220)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .