Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC MEGHA SADAN GAGANNAGAR CURTI PONDA GOA 403401 | PONDA | SOUTH GOA | GOA | 403401 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹26.3 L+₹1.3 L (5.28%)Rejected-Finance | L2 | Rejected-Finance BEING L2 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR AND MAINT OF LT DISTRIBUTION SYSTEM AND REPLACEMENT OF LT UG CABLES AT DARJIPURA AREA AT AF STN BARODA
2022_MES_536329_1
8717/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹60,000
Yes
3 Sept 2022
7 Jul 2022
6 Aug 2022
7 Jul 2022
4 Aug 2022
22 Jul 2022
8 Jul 2022 - 14 Jul 2022
Amount
M&L for repair and rectification of external LT electric supply complaints on 1100 Volts grade, over head/underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
Replacement of worn out jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
Taking out existing cable of following sizes from Junction boxes/overhead lines/LT Pannels/Poles/PCC Copying and cut out the worn out/burnt portion of cable, extend the cable from loop including excavation and re-fixed the same after providing new lugs :-
3.5 Core 16 Sqmm to 50 Sqmm
3,5 Core 70 Sqmm to 240 Sqmm Note :- (i) LT Jointing Kits, Cable protection Pipe, Excavation, Returning Filling, Removing, Sand and PCC copying of poles if required at site will be measured and paid separately under relevant items. (ii) Taking out old Bricks covers will be re-used as cable protection. (ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes.
Supply, install testing and commissioning in repair weather and vermin proof LT feedar pillar bus bar junction box (Panel board) factory fabricated (CPRI approved) Outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 60cm X 50 cm X 60 cm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of suffiecient Nos of circular cable entry holes at bottom only with suitable of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required Nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with L.T armoured incoming and outgoing cables and including required sizes of cable lugs of aluminium complete all as specified and directed ( as per sample )and consisiting of following :- (a) Bus bars of Aluminium strips of 400 Amp current rating capacity, minimum 600 mm long or of length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulator complete with CTs of suitable size with nut bolt fixing arrangement complete - 01 set
M&L for ACSR conductor, steel reinforced for LT over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator/streching of ACSR conductor including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed.
M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
M&L for Shackle type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 Volt grade, section of straps 31x5 mm, including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
S&F Stay assembly comprising of 7/10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, upto 50m including disconnecting/taking out old existing unsv stay assembly complete all as specified and directed.
S&F of Galvanised steel wire (GI) 4mm dia including disconnecting/taking out old existing unsv GI wire complete all as specified and directed.
M/L for cross arms, bracing, supports clamps and back plates fabricated from structural steel section, 3mm Stainless steel Sheet incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/taking out old existing unsv cross arms complete all as specified and directed.
S&F Loadline MCCB (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK), Adjustable thermal and fixed magnetic setting of capacity 400 Amps, 4 Pole, 36 KA, 415 Volt including disconnecting/taking out existing old unsv/burned MCCB complete all as specified and directed.
All as per item No 10 here in before but of capacity 250 Amps, 4 pole, 25 KA complete all as specified and directed
All as per item No 10 here in before but of capacity 200 Amps, 4 pole, 25 KA complete all as specified and directed
All as per item No 10 ere in before but of capacity 160 Amps, 4 pole, 16 KA complete all as specified and directed
All as per item No 10 here in before but of capacity 125 Amps, 4 pole, 16 KA complete all as specified and directed
All as per item No 10 here in before but of capacity 100 Amps, 4 pole, 16 KA complete all as specified and directed
All as per item No 10 here in before but of capacity 63 Amps, 4 pole, 16 KA complete all as specified and directed
S&F MCB/Isolator, 100 Amps, 4 pole, 415 Volts with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.
All as per item No17 here in befor but of capacity 63 Amps, 4 pole, 415 Volts with breaking capacity 10KA complete all as specified and directed
All as per item No 17 here in befor but of capacity 40 Amps, 4 pole, 415 Volts with breaking capacity 10KA complete all as specified and directed
S&F MCB, SP 6-32 Amps, 415 Volts with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.
Supply and fixing surface mounting digital timer switch 240 Volts, 50 Hz, 16-32 Amps rating (For Street light/High Mast light) fitted inside steel enclosure complete all as specified and directed
S&F Timeite distribution boards, Timelite-32A, 3 Pole/230V - Astronomical time switch along with suitable size of box made of sheet 2mm thick size 30x25x15 cm powder coated suitable for fixing at pole including two set of clamps comprising with the following :- (i) MCB TPN 32 Amps 10 KA - 01 No. (ii) Digital Timer suitable for 24 hours operation of street light (iii) Contctor two pole 40 Amps 415 Volt coil operating voltage 230 volt (iv) Auto manual switch 10 Amps, complete all including internl connection done by using suitabale sie of copper wire complete ll as specified and directed.
S&F contactor 3 phase 415 volts 50 Hz of ML-2, 32 Amp rating, coil voltage 420 volts, fitted inside steel enclosure complete all as specified and directed. Make : L&T /HAVELLS/Legrand/Indoasian/C&S.
S&F contactor 3 phase 415 volts 50 Hz of MNX 32 coil voltage 420 volts, fitted inside steel enclosure complete all as specified and directed. Make : L&T/Legrand/Indoasian.
S&F contactor 3 phase 415 volts 50 Hz of MNX 40 coil voltage 420 volts, fitted inside steel enclosure complete all as specified and directed. Make : L&T /Legrand/Indoasian.
Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for straight through joint with jointing material and accessories suitable for aluminium conductor cable of size 16 to 50 Sqmm, 3.5 Core complete all as specified and directed.
All as per item No 26 above but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core complete all as specified and directed
All as per item No 26 above but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 185 Sqmm, 3.5 Core complete all as specified and directed
All as per item No 26 above but suitable for aluminium conductor cable of size from 240 sqmm, 3.5 Core to 400 Sqmm, 3.5 Core complete all as specified and directed
Supply and fix in repair MH/HPSV Lamp upto 1000W for search/flood light complete all as specified and directed
Supply, lay, commissioning and testing of cable jointing Kit for 11000 V grade cable for straight through joint with jointing material and accessories suitable for aluminium conductor cable of size 95 Sqmm 3 Core complete all as specified and directed.
All as per item No 31 above but suitable for aluminium conductor cable of size from 120 sqmm, 3 Core to 150 Sqmm, 3 Core complete all as specified and directed
All as per item No 31 above but suitable for aluminium conductor cable of size from 185 sqmm, 3 Core to 400 Sqmm, 3 Core complete all as specified and directed
Supply and lay cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, laid in trenches/duct or fied to wall/passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminium conductor of the following sizes including disconnnecting/taking out existing unsv/damaged old LT UG cable complete all as specified and directed :- Notes : Earthwork, Sand and covers shall be measured and paid separately.
2 core X 10 Sqmm complete all as specified and directed
2 Core X 16 Sqmm complete all as specified and directed
4 Core X 16 Sqmm complete all as specified and directed
3.5 Core X 25 Sqmm complete all as specified and directed
3.5 Core X 35 Sqmm complete all as specified and directed
3.5 Core X 50 Sqmm complete all as specified and directed
3.5 Core X 70 Sqmm complete all as specified and directed
3.5 Core X 95 Sqmm complete all as specified and directed
3.5 Core X 120 Sqmm complete all as specified and directed
3.5 Core X 150 Sqmm complete all as specified and directed
3.5 Core X 185 Sqmm complete all as specified and directed
3.5 Core X 240 Sqmm complete all as specified and directed
Taking down and relaying of existing exposed cable to underground of surface / re-using after jointing of straight through joint kit of following sizes complete all as specified and directed:- Notes:- (a) Earthwork, sand and cable cover shall be measured and paid separately. (b) Existing cable / joint shall be used for relaying.
3.5 Core 16 Sqmm to 50 Sqmm
3.5 Core 70 Sqmm to 120 Sqmm
Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Restreching/Restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and prunning of tree complete all as specified and directed. Notes: (i) The distance between pole to pole in one span (contains 2/4/6 runs) i.e one span will only be considered for payment purpose. (ii) No Extra conductor will be measured for binding to insulators / jumpering etc.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in Hard / Dense soil complete all as specified and directed.
All as per item No 38 above but depth exc 1.5 mtr but not exc 3 mtr complete all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down (i.e 18 cm) shall be measured for payment.
Supply and laying re-inforced precast concrete cable cover class LV, Type 1 flat size 250mmx150mmx40mm complete all as specified and directed.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as specified and directed
M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as specified and directed
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as specified and directed
Cutting the existing road/PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, MS casing pipe heavy duty of size 100 mm dia with 6 mm thick in any length including jointing materials to carry LT UG cables of size upto 400 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
M&L repair/maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed.
M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paint including throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos blue and 2 Nos white) from ground level, complete all as specified and directed.
M&L for Painting the existing LT PCC poles with 1 coats of synthetic enamole base paint including painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 blue and 2 white) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanized iron GI Wire 4mm dia, by means of nuts, bolts, check nuts and washer etc of galvanized iron and earth lead protected by provision of GI pipe medium grade 20mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- Item of earthing includes cost of 7.5m long galvanized iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. (iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering, stringing the ACSR conductor, Fuse wire etc, if damaged during triming of branches.
Cutting unaxious green growth and grass by manual labour or by machine at all 11 KV Electric Installation premisses/around 2/4 Pole structure/along the boundary fencing and removing rubbish from the site of work complete all as specified and directed.
S&F new generation energy saving and environmental friendly long life LED street light made up to pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10 KV Built-in-Surge Protection Device, road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. Make : Havells/ORIENT/BAJAJ Note : (i) LED's used should be the make of Cree/Osram/Lumilieds/Nitchia. (ii) Contractor has to produce LM-79/LM-80 certificate alongwith purchase vouchers. (iii) Surge protection of the drive should be 10 KV or equivalent model in Bajaj/Philips or Wipro
All as per item No 56 above but 80 watts. Make : Havells/ORIENT/BAJAJ complete all as specified and directed
All as per item No 56 above but 70 watts. Make : Havells/ORIENT/BAJAJ complete all as specified and directed
All as per item No 56 above but 60 watts. Make : Havells/ORIENT/BAJAJ complete all as specified and directed
S&F Energy saving, environmental friendly long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 150 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole including taking down old unserviceable light fitting of any type and capacity complete all as specified and directed. Make : Havells/ORIENT/Halonix or equivalent model in Philips/Wipro. Note : (i) LED's used should be the make of Cree/asram/Lumilieds/widchia (ii) Contractor has to produce LM-79/LM-80 certificate alonwith purchase vouchers and Guarantee certificate from Manufacturer. (iii) Surge protection of the driver should be 10 KV
S&F New generation, post-top, energy saving, environmental friendly long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, with high power LED as light source of capacity 36 watts and all standard accessories etc fixed to main gate in any location and position complete all as specified and as directed. Make Cat Part No PCGLP 01400 of Make Polycab, Cat Part No HLPT-01-40-CW of Make Halonix, Cat Part No LLOP-30-C of make orient
S&F in repair HPSV copper ballast 400W for flood light/Search Light Make Philips/Wipro/Havells complete all as specified and directed
S&F in repair HPSVIgnitor 400W for flood light/Search Light Make Philips/Wipro/Havells. complete all as specified and directed
S&F in repair LED Driver suitable for upto 72 watts LED light fittings complete all as specified and directed. Make : Philips/Wipro/Havells/ORIENT/Halonix.
S&F in repair MH Lamp 400W for flood light Make Philips/Wipro/Havells. complete all as specified and directed
Supply and fixing in repair steel light bracket made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified.
S&F PVC insulated unsheathed/sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/1990 with latest amendments ISI including disconnecting/taking out existing unsv/damaged old service cable complete all as specified and directed. Make : Richa/havells or equivalent.
All as per item No 67 above but of size 6 Sqmm complete all as specified and directed.
S&F street light LT junction box out door type, testing and commissioning with locking arrangements fixed on poles PVC Moulded of size 230x180x110 mm alongwith Bus Bar, 20 to 32 A MCB SPN - 01 Nos for connecting suitable size of XLPE UG cable complete all as specified and directed
Supply and laying GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm complete all as specified and directed
Supply and laying GI tubing light grade of size 50 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm complete all as specified and directed
Supply and laying GI tubing light grade of size 80 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm complete all as specified and directed
S&F LT line rigid PVC Spacers spiral type, two lines, Phase to phase distance 300 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm complete all as specified and directed
S&F LT line rigid PVC Spacers spiral type, three lines, Phase to phase distance 600 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm complete all as specified and directed
S&F LT line rigid PVC Spacers spiral type, four lines, Phase to phase distance 900 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm complete all as specified and directed
S&F in repair On-Load changeover switch (In sheet steel enclosure), AC 21 (Side Handle), 4 pole of capacity 250 Amps, 415 Volts, 50 Hz complete all as specifed and directed
S&F in repair On-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 160 Amps, 415 Volts, 50 Hz complete all as specifed and directed
S&F in repair On-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 63 Amps, 415 Volts, 50 Hz complete all as specifed and directed
Supply only of aluminium cable lugs of following sizes :-
16 Sqmm Size complete all as specified and directed
25 Sqmm size complete all as specified and directed
35 Sqmm size complete all as specified and directed
50 Sqmm size complete all as specified and directed
70 Sqmm size complete all as specified and directed
95 Sqmm size complete all as specified and directed
120 Sqmm size complete all as specified and directed
150 Sqmm size complete all as specified and directed
185 Sqmm size complete all as specified and directed
240 to 400 Sqmm Make for ser No 79.01 to 79.10 : Dowells/Jaison. complete all as specified and directed
Supply only of insulation tap roll for cable protection of following sizes :-
25 mm Size of 100 RM length complete all as specified and directed
15 mm Size of 100 RM length complete all as specified and directed
M&L for welding existing broken panel doors and fixing good quality hinges(any size any number of hinges per panel) of suitable size for making open and close the panel doors and fixing/welding angle/notch and Nut Bolts washers of suitable size to keep the door locked and including welding and making good any other broken portion of panel(double door also) complete all as specified and directed
Suppl only copper wire 35 Sqmm multistranded for Pannel board complete all as specified and directed
M&L for sprinkling of ODYSSEY Herbicide near Two/Four Pole structure/LT Pannels/DG Sets/solar Pannel E/M Installation all as per Reqmt complete all as specified and directed. Note :- Herbicides will be sprinkled by Concerned sprinkling Machine only and not to manually. Sprinkling Machine will be provided by contractor.
M&L and spreading of Graded stone aggregate of size 40mm grade complete for two pole and four pole structure complete all as specified and directed
Supply and fix Cable Route Indicator for LT UG Cable 0f 1100 Volts bolted with 40X6 mm flat Iron member of height 0.60 Mtr, and 80mm dia CI Plate embeded in PCC 1:3:6 type C2 of size 20X20X30 Cm block complete all as specified and directed
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation of LT Pannel/DG Sets/ mass complete all as directed
M& Labour for hiring of fault Locator Machine comlete from the authorised sulier alongwith their team, finding out the exact LT fault location from both end termination of underground cable incl necessary excavation and earth work comlete all as secified and directed
Shiv Kripa Tradimg
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .