Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹84.2 LAccepted-Finance POST OFFICE ROAD DHARMANAGAR DHARMANAGAR NORTH TRIPURA | NORTH TRIPURA | TRIPURA | 799250 | ₹84.2 L | L-1 | Accepted-Finance Accepted |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹93.0 L
EMD Value
₹1.9 L
Closing Date
18 Jul 2024, 5:00 pmClosed
DGM, ED-Teliamura
O/o the DGM, ED-Teliamura, Gamai Bari, Khowai District
Extension of HT/LT line including construction of 19X25KVA sub-station for low voltage problem to SBDTW Scheme of DWS (PWD) Dept., Kalyanpur Division within the jurisdiction of ESD-II, Teliamura, ESD-Kalyanpur and ESD-Mungiakami under Electrical Divi
2024_POWER_50511_1
DGM/ED-TLM/2024-25/02, Dt. 02.07.2024
Open Tender
Electrical Works
Turn-key
120 days
Under ED-Teliamura
As per NIT
3 documents required · 3 mandatory
₹5,000
₹1.9 L
Yes
O/o the DGM, ED-Teliamura
23 Apr 2025
4 Jul 2024
19 Jul 2024
4 Jul 2024
18 Jul 2024
9 Jul 2024
5 Jul 2024 - 7 Jul 2024
8 Jul 2024
Amount
Supply of the following :-
PCC pole 9m long
PCC pole 8m long
Stay set complete
GI Stay wire stranded stay wire
11 KV Stay insulator
LT Stay insulator
Stay clamp (50x6mm)
ACSR Weasal (6/1/2.59mm)
8SWG GI Wire
M.S. CHANNEL(100x50x50x6mm)
M.S. CHANNEL (75x40x40x6mm)
M.S. ANGLE (65x65x6mm)
M.S. ANGLE (50x50x6mm)
Bracket clamp 50 x6 mm
Nuts and Bolts
11KV Polymer Pin Insulator
11KV Polymer composite 45KN Disc Insulator
11KV Disc fittings Up to 7/3.8mm, 2-U Bolt type
11KV Gang Operated Switch (Polymeric type) (3 Post)
11 KV Drop out Switch (Polymeric)
Lightining Arrestor 9KV, 5KA Polymeric LA
PVC CABLES (SINGLE CORE) 70 mm2
PVC CABLES (SINGLE CORE) 35 mm2
PVC CABLES (SINGLE CORE) 16 mm2
PVC CABLES (SINGLE CORE) 120 mm2
Aluminium Lugs 120 mmsq
Bimetallic Lugs 50 mmsq
Bimetallic Lugs 95 mmsq
Rewireable Porcelain Cut out 100 Amp
Rewireable Porcelain Cut out 63 Amp
Rewireable Porcelain Cut out 200 Amp
Wooden Plank
DANGER PLATE H.T.
Supply of 60Kg Salt, 55Kg Charcoal (For 1 Pit)
Supply of 2.5mtr long 40mm dia GI Pipe, Make: TATA/JINDAL
1/2 dia PVC pipe for earthing
LT Shackle Insulator (3x 3.5)"
Straps with Nuts Bolts
LT AB Cable (3x50+1x16+1x35 sqmm)
Accessories of LT AB Cable Dead End Clamp (35-50mm)
Accessories of LT AB Cable P.I. Jointing Sleeve (35 mm2)
Accessories of LT AB Cable Suspension Clamp (35 - 50 mm)
Accessories of LT AB Cable Service Anchor Clamp (18-50mm)
Accessories of LT AB Cable IPC Main 16-95 sqmm & Tap 4 to 35(50) sqmm
Accessories of LT AB Cable- Cable End Cap (50sqmm)
Accessories of LT AB Cable- Cable Ties
Accessories of LT AB Cable- Eye Hook
Accessories of LT AB Cable- Pole Clamp
Distribution Box 3-Phase
Distribution Box 1-Phase
Chain Pully Block 5 ton capacity x 3m lift.
Reeal Insulator 4-10 Sq. mm.
Adjustable Wrench 26mm
Plier 210mm
Crimping Tool 400 mm2
Bamboo Ladder (HT)
Bamboo Ladder (LT)
Megger 5000VA
Erection of the following
Erection of 9.0 mtrs length of PCC pole at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with soil upto the ground level, remming and making complete in all respect i/c Hand-Cart carriage & Mannual carriage with necessary loading & unloading.
Erection of 8.0 mtrs length of PCC pole at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with soil upto the ground level, remming and making complete in all respect i/c Hand-Cart carriage & Mannual carriage with necessary loading & unloading.
Erection of 9 Mtr Steel Pole at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with soil upto the ground level, remming and making complete in all respect i/c Hand-Cart carriage & Mannual carriage with necessary loading & unloading.
Erection of 8 Mtr Steel Pole at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with soil upto the ground level, remming and making complete in all respect i/c Hand-Cart carriage & Mannual carriage with necessary loading & unloading.
Erection of Stay set direct in earth complete with 19mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm, thimble, turn buckle, 7/3.15 mm dia G.I Standed stay wire and stain insulator etc. with supply if M.s clamp, nuts & Bolts etc. as required. and making complete in all respect.
Fabrication of cross arms by MS Channel/MS Angle as per specification
Erection of MS Channel Cross Arm 0.6 to 2.8 mtr long 100x50x50x6mm (Excluding the cost of Bkt clamp, N&B)
Erection of MS Channel Cross Arm 1.3 to 2.8 mtr long 75x40x40x6mm (Excluding the cost of Bkt clamp, N&B)
Erection of MS Channel Cross Arm 0.3 to 1.2 mtr long 75x40x40x6mm (Excluding the cost of Bkt clamp, N&B)
Erection of MS Channel Cross Arm 1.0 to 2.5 mtr long 65x65x6mm (Excluding the cost of Bkt clamp, N&B)
Erection of M.S.Angle Cross-Arm bracket of 2 wire upto 1100Mtr. Long of 50 x 50 x6mm/ 65x65 x 6 mm
Erection of C type bracket for LT 5-wire of 50 x 50x6mm/ 65 x65 x 6 mm( Excluding the cost of BackClamp, Nuts & Bolts)
Erection of 11KV polymer pin insulator
Erection of 11KV disc insulator set with necessary fittings.
Erection of shackle insulator of size 75mmx90mm/ 100mmx15mm with straps & bolts/u clamp on poles (Excluding the cost of U clamp, N&B)
Laying & stringing of 1KM (Single Conductor) ACSR 6/1/2.59 mm dia 'WEASEL' including hoisting & binding etc. Complete as required.
Laying & stringing of 1KM (Single Conductor) 8SWG GI wire including hoisting & binding etc. Complete as required.
Erection of 11 KV protective Guarding by GI Wire 8 SWG as per technical specification, across road/River/Telecom line etc. in horizonta formation complete.
Erection of 11KV 200Amps GOS unit set of three nos including necessary connection complete as per technical specification.
Erection of 11KV 200Amps DOF unit set of three nos including necessary connection complete as per technical specification.
Erection of 9KV, 5KA single pole metal oxide gapless type LA including necessary connection complete as per technical specification.
Installing/Positioning of 11/.0430KV, 3-Phase 25KVA Distribution Transformer on pole with nessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing.
Earthing with G.I pipe 2.5mtr long and 40mm dia including excavation, refilling with alternate layer of Salt & Charcoal as per drawing
Laying of 8 SWG GI wire at 300mm below the ground level for earthing of Sub-Station equipments from the earth electrode
Erection of Danger Plate on OH lines (11KV/415V)
Fitting, fixing of LT cut-out (03 nos) on wooden plank (Preferably Karai wood) of size of 24x10x1.5 inch & cable connections with termination by lugs/thimbles complete i/nc supply of wooden plank, screws & clamps.
Positioning of cable drum, removing of cable fromdrum and Laying, hoisting & drawing of AB Cable3X35-50+1x16- 5+1x35-50 sqmm of 101 KV gradeas per direction of Engineering In-Charge.
Fitting-Fixing of Service main 1/3Phase distributionBox of 1.1 KV grade on PCC/Steel Pole with the help Pole brackets or Steel Straps &buckIes asperdirection of Engineering In-Charge.
Providing 1/3Phase Service Connection with laying PVC cable from nearby Electrical pole to Premises upto 35mtr. in length supported by G.I.Wire,Reel Insulator i/c fitting fixing of Energy Meter as required
Erection & Fitting-Fixing of Insulated Suspension Clamp including Pole clamp, Eye hook for cable massenger of 1.1 KV grade on PCC/Steel Pole with the help Pole brackets or Steel Straps &buckIes asper direction of Engineering In-Charge.
Erection & Fitting-Fixing of Insulated Dead end enchoring Clamp including Pole clamp, Eye hook for cable massenger of 1.1 KV grade on PCC/Steel Pole with the help Pole brackets or Steel Straps &buckIes asper direction of Engineering In-Charge.
Erection & Fitting-Fixing of Insulated Insulation Piercing Connector (IPC) all sizes of 1.1 KV grade including connection from main cable to distribution box, Tee-Off line as per direction of Engineering In-Charge.
Providing of sub-station protective fencing of size 2x3Mtr and height 1.5Mtr as per Engineering requirement by 10 nos M.S.Angle post (50x50x6mm) of height of 2 (Two) meter horizontalbar 2x3mtr & 2x2Mtr M.S.Angle (35x35x5mm) at top of angle posts and two part M.S. Grill door of size 1.2/1.4 with locking arrangement i/nc necessary grouting and painted by Al paintover red oxide priming of approval quality as required as per TS including supply of all materials.
Carriage of 11/0.430, 3-Phase, 25KVA Transformer by mechanical transport from site/store/workshop to working site vis-a-vis including loading, unloading and placing on base, as required. c) Beyond 50Km [Additional amount of Rs. 298.00 for every 25Km or part thereof]
Carriage of . of 7.5mtrs /8.0mtrs / 9.0mtrs length of Steel Tubular Poles by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required a) Upto the lead range 25 KM i) For maximum 8 (eight) poles From MMD Store to Sub Division Store
Maintaining adequate clearance from overhead live conductors by Trimming of tree branches for Way Leaves
Numbering of Pole/DT with black Japper paint after applying priming coats by red oxide primer followed by a painting 2 or more coats with synthetic enamel paint (Yellow Colour/Black Colour) of approved quality within a area of 8X14 on pole /DT as required as per direction of the Engineer-in-Charge. (8 mtr ,9 mtr etc pcc pole).
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .