| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.1 L+₹1.2 L (7.38%)Rejected-Finance | L2 | Rejected-Finance Being L2 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R AND D Chandigarh
Garrison Engineer I R and D, DIHAR Base Lab, Ground Floor, Near 3 (BRD) AF Stn, Industrial Area, Ph-II, Ramdarbar, Chandigarh
REPAIR AND MAINT OF SUMMER APPLIANCES AND OTHER CONNECTED WORK IN CHANDIGARH AND RAMGARH AREA UNDER GE (I) R AND D CHANDGIARH
2023_MES_594626_3
GE (I) R AND D/CHD-11/2023-24
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandigarh
₹40,000
Yes
16 Sept 2023
7 Aug 2023
30 Aug 2023
7 Aug 2023
28 Aug 2023
8 Aug 2023
Amount
RAMGARH AREA Providing services for attending all types of day to day complaints of maintenance, repair, replacement of unserviceable worn out spare parts, overhauling including soldering, spraying, chemical cleaning with detergents, leak repairing, charging fresh refrigerant, dismantling, reassembling and periodical services in respect of all make, work & type of cooling appliances i.e., Air Conditioners (window type, split type, cassette type and ductable type) , water coolers , desert coolers and voltage stabilizers installed at various labs/locations in TBRL range Ramgarh by providing skilled qualified refrigerator mechanic cum electrician with helper per day alongwith required tools/equipments/machine/test kits/gas filling gauge, gas charging adopter, gas charging valve, drill machine with drill bit, allen key set, ladders, ropes ,clamp meter, brazing rod, butane gas cylinder, tape roll, vacuum pump, suction discharge valve, washing pump, spanner set, copper tube cutter, flaring tool, & other instruments which are required for maintenance, repair and to make the equipment functional and for keeping all equipments in perfectly clean, tidy and functional condition in all times . The complaints record to be maintained on the complaint register & complaint slips all as directed. Note: (i) Cost of spares including refrigerent for charging and rewinding /replacement of condensor fan motors,compressor,blower fan etc if required shall be measured and paid seperately under respective item of sch'A' (ii) 01x ref mechanic and 1 x helper to be provided from 0900 hrs to 1700hrs. (iii) Non attending of complaints will be recovered @ Rs 250 per complaint
CHANDIGARH AREA Providing services for attending all types of day to day complaints of maintenance, repair, replacement of unserviceable worn out spare parts, overhauling including soldering, spraying, chemical cleaning with detergents, leak repairing, charging fresh refrigerant, dismantling, reassembling and periodical services in respect of all make, work & type of cooling appliances i.e., Air Conditioners (window type, split type, cassette type and ductable type) , water coolers , desert coolers and voltage stabilizers installed at various labs/locations in Chandigarh area by providing skilled qualified refrigerator mechanic cum electrician with helper per day alongwith required tools/equipments/machine/test kits/gas filling gauge, gas charging adopter, gas charging valve, drill machine with drill bit, allen key set, ladders, ropes ,clamp meter, brazing rod, butane gas cylinder, tape roll, vacuum pump, suction discharge valve, washing pump, spanner set, copper tube cutter, flaring tool, & other instruments which are required for maintenance, repair and to make the equipment functional and for keeping all equipments in perfectly clean, tidy and functional condition in all times . The complaints record to be maintained on the complaint register & complaint slips all as directed. Note: (i) Cost of spares including refrigerent for charging and rewinding /replacement of condensor fan motors,compressor,blower fan etc if required shall be measured and paid seperately under respective item of sch'A' (ii) 01x ref mechanic and 1 x helper to be provided from 0900 hrs to 1700hrs. (iii) Non attending of complaints will be recovered @ Rs 250 per complaint
Supply only the new blower motor for split type A/C unit of capacity 1.5/2.0TR as per existing model complete all as specified and directed.
Supply only in replacement of air filter for split type A/C units of capacity 1.5 TR/2 TR as per sample complete all as specified and directed.
Material only for providing insulation to copper tubing’s from Indoor to outdoor units with foam insulation followed with PVC flexible pipe 50mm with clamps complete all as specified and directed.
Supply only of copper tubing 3/8” outer dia suitable for AC 1.5TR/ 2TR capacity complete all as specified and directed.
Supply only in replacement of indoor unit complete suitable for existing outdoor unit of any make of split AC of cap 1.5/2.0TR complete all as specified and directed.
Supply only of copper tubing 5/8” outer dia suitable for AC 1.5TR/ 2TR capacity complete all as specified and directed.
Supply only of copper tubing 1/2” outer dia suitable for AC 1.5TR/ 2TR capacity complete all as specified and directed.
Supply only of copper tubing 1/4” outer dia suitable for AC 1.5TR/ 2TR capacity complete all as specified and directed.
Supply only in replacement of starting relay for split type AC units of capacity 2 TR as required at site complete complete all as specified and directed.
Supply only in replacement of contactor, as per existing model, coil voltage 230V installed in split type AC units complete all as specified and directed.
Rewinding/replacement of bush/bearings of condenser fan motor of split type AC units of capacity 1.5 TR/2 TR complete all as specified and directed.
Rewinding/replacement of bush/bearings of blower fan motor of split type AC units of capacity 1.5 TR/2 TR complete all as specified and directed.
Supply only in replacement of indoor unit blower suitable for Split AC Capacity 1.5 / 2.0 TR complete all as specified and directed.
Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and replacing the same with new one from the company as per existing model complete all as specified and directed.
Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and replacing the same with new one from the company as per existing model complete all as specified and directed.
Supply only in replacement of outdoor unit complete suitable for existing indoor unit of any make of split AC of cap 1.5TR complete all as specified and directed.
Supply only in replacement of outdoor unit complete suitable for existing indoor unit of any make of split AC of cap 2.0TR complete all as specified and directed.
Supply only the new remote control unit (cordless)as per existing model for 1.5 TR/ 2 TR split type A/C unit complete all as specified and directed.
Supply only condenser fan blade for split AC 1.5/2.0 TR complete all as specified and directed.
Supply only drain hose pipe of length 05 meter for air conditioner/ water cooler complete all as specified and directed.
Supply only PCB of cooling unit of split AC 1.5TR/2.0TR complete all as specified and directed
Supply only in replacement of thermostat for split type Ac 1.5/2.0 TR as required at site complete all as specified and directed.
Supply only in replacement of overload protector for compressor as reqd at site for AC 1.5/2.0TR complete all as specified and directed.
Supply only in replacement of starting relay as required at site for water coolers complete including connecting, testing complete all as specified and directed.
Disconnecting and rewinding of condenser motor single phase of 1/16 HP for water coolers & refixing the same with clamps bolts, nuts and rubber bushes including connecting, testing complete all as specified and directed.
Supply only of gas R-22 complete all as specified and directed.
Supply only of gas R-32 complete all as specified and directed.
Supply only in replacement of waste water tray as required at site made out of 20 gauge GI sheet complete with PVC drain pipe including painting with PVC drain pipe including painting with aluminum paint complete all as specified and directed.
Supply only in replacement of brass float valves accessories 15mm size as required at site complete all as specified and directed.
Supply only in replacement of starting capacitor 80-100/100-120 mfd for split type A/C's of capacity 1.5TR/2 TR complete all as specified and directed.
Disconnecting and taking out compressor ('R type) from water cooler and fixing new including flushing dehydration and gas charging complete all as specified and directed.
Supply only in replacement of running capacitor 30/36 mfd for split type AC unit as required at Site complete all as specified and directed.
Supply only capcitor 10 MFD suitable for Air conditioner/ water cooler complete all as specified and directed.
Supply only self closing taps of cast iron galvanised, chromium plated screwed for 15mm bore dia iron pipe suitable for water coolers complete all as specified and directed.
Supply only in replacement of new condenser motor single phase of 1/16 HP as required at site for water cooler with clamps, bolts, nuts & rubber bushes complete including connecting testing complete all as specified and directed.
Supply only Distribution box with plug and socket & 20 A DP with plastic cover complete all as specified and directed.
Supply only in replacement the new desert cooler pump. including testing for proper functioning complete all as specified and directed.
Supply only in replacement of wood wool pad set of three for desert cooler complete all as specified and directed.
Supply only in replacement desert cooler moter single phase, 50 Hz, 250 Volt, 180 W, 1400 RPM complete all as specified and directed.
Supply only in replacement new body of desert cooler as per sample duly painted of 20 SWG sheet with 22 SWG flops, front grill, PVC pipe, nozzle, distributor and nut bolts washers for fixing fan clamps, complete all as specified and directed.
Supply only front grill of desert cooler as per sample complete all as specified and directed.
Supply only PVC distributor heavy duty as per sample complete all as specified and directed.
Supply only in replacement plug top 5 Amps complete all as specified and directed.
Supply only in replacement plug top 15 Amps complete all as specified and directed.
Supply only PVC flexible pipe 15mm bore heavy duty for desrt cooler complete all as specified and directed
Supply only in replacement of capacitor 40/45 mfd for AC as required at site complete all as specified and directed.
Supply only in replacement of capacitor 4 mfd for desert/water cooler as required at site complete all as specified and directed.
Supply only in replacement of over load protector for 1.5/2.0 TR W/AC complete all as specified and directed.
Supply only in replacement of blower motor as required at site for W/Ac single phase 230 volts double shaft with clamp bolts, nuts and rubber bushes complete all as specified and directed.
Supply only in replacement of air filter of w/AC 1.5 TR capacity Make-Coir foam or equivalent as required at site complete all as specified and directed.
Supply only in replacement starting relay for W/T A/C as required at sitecomplete all as specified and directed.
Supply only in replacement of capacitor 50+6 mfd for AC as required at site complete all as specified and directed.
Supply only in replacement of thermostats as required at site complete for window type AC 1.5 TR complete all as specified and directed.
Disconnecting and taking down compressor 1.5 TR W/AC as per existing make and Refixing the same after replacing with new one including flushing, dehydration and gas changing complete all as specified and directed.
Disconnecting and taking down compressor 2.0 TR W/AC as per existing make and Refixing the same after replacing with new one including flushing, dehydration and gas changing complete all as specified and directed.
Supply only of gas R-134A complete all as specified and directed.
Supply only of gas R-410A complete all as specified and directed.
Disconnecting & taking down of window type AC 1.5 TR of any make and Refixing the same after replacement of cooling coil including soldering/welding dehydration complete all as specified and directed.
Supply in replacement of Blower suitable for Window AC capacity 1.5 / 2.0 TR complete all as specified and directed.
Disconnecting and taking down of window type AC of any make and Refixing the same after replacement of condenser coil including soldering/welding and commissioning complete all as specified and directed.
Servicing and minor repair if any to voltage stabilizer of capacity 5 KVA. complete all as specified and directed.
Servicing and minor repair if any to voltage stabilizer of capacity 4 KVA. complete all as specified and directed.
Supply only PVC insulated copper conductor cable of size 3 core, 1.0 sqmm, 1100 volt grade complete all as specified and directed.
Supply only PVC insulated copper conductor cable of size 3 core, 1.5 sqmm, 1100 volt grade complete all as specified and directed.
Supply only PVC insulated copper conductor cable of size 3 core, 2.50 sqmm, 1100 volt grade complete all as specified and directed.
Taking out of old, unserviceable worn out existing mild steel stand of any size and replacementof MS stand of suitable size fabricated out of angle iron alongwith 02 Nos legs duly grouted on walls of the building near window and 02 Nos diagonal angle iron supports duly welded to frame and legs and painted with two coat of synthetic enamelled paint over a coat of red oxide primercomplete all as specified and directed.
Material and labour for shifting of AC's any type/capacity from any height & location and refix the same on another location after making necessary cutting on wall/roof/window/glass/grills as per requirement of users, complete all as specified and directed.(Note:- Necessary insulation for copper tubing,gas filling,ply work shall be measured and paid seperately under respective item)
Taking down carefully by sub main wiring/service connection of any type complete all as specified and directed.
Material and labour for sub main wiring with two runs of single core, PVC insulated, unsheathed ,multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade and one run of 2.5 Sqmm PVC insulated earth continuity copper conductor cable drawn through and inculding suitable size of PVC concealed conduit with all necesary accessories such as bends, tees, junctions boxes, elbows etc complete with all in coming and out going cable connections complete all as specified and directed. (Note : Two runs of 4 Sqmm cable, one run of 2.5 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one unit length).
Supply and fixing in replacement PVC connections 15 mm size with PTMT nuts of length 450 mm suitable for Water coolers/Geysers complete all as specified and directed.
Supply and fixing in replacement PVC connections 15 mm size with PTMT nuts of length 600 mm suitable for Water coolers/Geysers complete all as specified and directed.
Supply, installation and testing of printed control board of indoor unit and outdoor unit both of cassette type AC (inverter type) Cap 2.5 TR as per sample complete all as specified and directed.
Supply, installation and testing of printed control board of indoor unit and outdoor unit both of cassette type AC (inverter type) Cap 4.0 TR as per sample complete all as specified and directed.
Supply and fixing in replacement stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle, fancy type and chromiun plated screwed both ends for iron pipe or for unions all as specified and as directed of size 15 mm bore , complete all as specified and directed.
Supply and fixing in replacement 15 mm nominal size, screw down bib taps, cast copper alloy with crutch or butterfly handle screwed down, fancy type, chromium plated complete all as specified and directed.
Supply and fixing in replacement of apparatus plate (Geyser Assembling Unit) with rubber gasket including nuts, bolts and washers consisting of 6 Nos of holes suitable for existing geysers complete all as specified and directed.
Supply only thermostat 7'/11' for geyser with adjustable temperature setting range complete all as specified and directed.
Supply only brazing rod for copper tube welding complete all as specified and directed.
Supply only Butane gas cylender 230 Gram for brazing rod welding complete all as specified and directed.
Supply only for suction valve with dead end cap at outdoor unit of split type Air conditioner 1.5/2.0 TR complete all as specified and directed.
Supply only for discharge valve with dead end cap at outdoor unit of split type Air conditioner 1.5/2.0 TR complete all as specified and directed.
AIRCOM
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .