Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.5 L+₹2.0 L (9.50%)Rejected-Finance 1080 JESSORE ROAD DUM DUM KOLKATA 700028 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700028 | L2 | Rejected-Finance not L1 hence rejected | |
| 3 | L3₹22.6 L+₹2.0 L (9.76%)Rejected-Finance P 27 1 RASHTRAGURU AVENUE DUM DUM KOLKATA 700028 | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L3 | Rejected-Finance not L1 hence rejected | |
| 4 | L4₹30.0 L+₹9.4 L (45.7%)Rejected-Finance | L4 | Rejected-Finance not L1 hence rejected | |
| 5 | L5₹30.9 L+₹10.3 L (50.2%)Rejected-Finance | L5 | Rejected-Finance not L1 hence rejected |
Tender Value
₹38.3 L
EMD Value
₹76,619
Closing Date
11 Nov 2019, 6:00 pmClosed
AGM(E-E), ER
O/o the GM (Engg), ER Operational office, AAI, NSCBI Airport, Kolkata
Repair / Replacement of damaged LT Power Cable for Nav-Aid installations at NSCBI Airport, Kolkata.
2019_AAI_33815_1
AAI/ER/KOL/EE/SRCable/19-20
Open Tender
Electrical Works
Works
122 days
Work
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,120
GM AAI
₹76,619
12 Mar 2020
31 Oct 2019
18 Nov 2019
1 Nov 2019
11 Nov 2019
1 Nov 2019
1 Nov 2019 - 7 Nov 2019
Amount
Supply and laying of Double Wall Corrugated HDPE pipes of 90 mm outer dia along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Supply and laying of Double Wall Corrugated HDPE pipes of 90 mm outer dia along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc. in hard surface including cutting the cement concrete/ bitumen portion including cutting, jointing of pipe & making good the surface matching with original finish etc. complete as required and as per the instruction of Engineer-in-charge.
Supply and laying of 150 mm dia GI pipe complete with G.I. fittings for drain crossing complete as required.
Supply and laying of XLPE insulated PVC sheathed armoured aluminium conductor cable of grade 1.1 KV, confirming to IS: 7098 Part-I with up-to-date amendments etc. complete as required. of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. 3.5c x 150 Sq mm
Supply and laying of XLPE insulated PVC sheathed armoured aluminium conductor cable of grade 1.1 KV, confirming to IS: 7098 Part-I with up-to-date amendments etc. complete as required. of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required. 3.5c x 120 Sq mm
Supply and laying of XLPE insulated PVC sheathed armoured aluminium conductor cable of grade 1.1 KV, confirming to IS: 7098 Part-I with up-to-date amendments etc. complete as required. of following size in the existing masonry open duct as required. 3.5c x 150 Sq mm
Supply and laying of XLPE insulated PVC sheathed armoured aluminium conductor cable of grade 1.1 KV, confirming to IS: 7098 Part-I with up-to-date amendments etc. complete as required. of following size in the existing masonry open duct as required. 3.5c x 120 Sq mm
Supply and laying of XLPE insulated PVC sheathed armoured aluminium conductor cable of grade 1.1 KV, confirming to IS: 7098 Part-I with up-to-date amendments etc. complete as required. of following size on wall surface as required. (clamped with 25/40x3mm MS flat clamp) 3.5c x 150 Sq mm
Supply and laying of XLPE insulated PVC sheathed armoured aluminium conductor cable of grade 1.1 KV, confirming to IS: 7098 Part-I with up-to-date amendments etc. complete as required. of following size on wall surface as required. (clamped with 25/40x3mm MS flat clamp) 3.5c x 120 Sq mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 150 sq. mm (50mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3½ X 120 sq. mm (45mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 150 sq. mm
ANIRBAN ENTERPRISE
Youngmen Traders
CHENNAI ENGINEERING SERVICES
Shantha ELectricals and Engineers Pvt Ltd
T K MAZUMDER
POWER TECH GLOBAL PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .